期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Detection of long bones based on Barker code excited ultrasonic guided waves 被引量:5
1
作者 ZHANG Huilin SONG Xiaojun TA De'an 《Chinese Journal of Acoustics》 2014年第2期136-146,共11页
Single pulse excited ultrasonic guided wave surfers high attenuation during the propagation in long bones.This results in small amplitude and low signal-to-noise ratio(SNR)of measured signals.Thus,the Barker code ex... Single pulse excited ultrasonic guided wave surfers high attenuation during the propagation in long bones.This results in small amplitude and low signal-to-noise ratio(SNR)of measured signals.Thus,the Barker code excitation is introduced into long bone detection to improve the quality of received signals,due to its efficiency in increasing amplitude and SNR.Both simulation and in vitro experiment were performed,and the results were decoded by the weighted match filter(WMF) and the finite impulse response- least squares inverse filter(FIRLSIF),respectively.The comparison between the results of Barker code excitation and sine pulse excitation was presented.For 13-bit Barker code excitation,WMF produced 13 times larger amplitude than sine pulse excitation,while FIR-LSIF achieved higher peak-sidelobe-level(PSL) of -63.59 dB and better performance in noise suppression.The results show that the Barker code excited guided waves have the potential to be applied to the long bone detection. 展开更多
关键词 code Detection of long bones based on Barker code excited ultrasonic guided waves FIR
原文传递
Performance improvement of magneto-acousto-electrical tomography for biological tissues with sinusoid-Barker coded excitation 被引量:6
2
作者 余正风 +4 位作者 李禹志 马青玉 郭各朴 屠娟 章东 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第9期346-353,共8页
By combining magnetics, acoustics and electrics, the magneto-acoustic-electrical tomography(MAET) proves to possess the capability of differentiating electrical impedance variation and thus improving the spatial res... By combining magnetics, acoustics and electrics, the magneto-acoustic-electrical tomography(MAET) proves to possess the capability of differentiating electrical impedance variation and thus improving the spatial resolution. However,the signal-to-noise ratio(SNR) of the collected MAET signal is still unsatisfactory for biological tissues with low-level electrical conductivity. In this study, the formula of MAET measurement with sinusoid-Barker coded excitation is derived and simplified for a planar piston transducer. Numerical simulations are conducted for a four-layered gel phantom with the 13-bit sinusoid-Barker coded excitation, and the performances of wave packet recovery with side-lobe suppression are improved by using the mismatched compression filter, which is also demonstrated by experimentally measuring a three-layered gel phantom. It is demonstrated that comparing with the single-cycle sinusoidal excitation, the amplitude of the driving signal can be reduced greatly with an SNR enhancement of 10 dB using the 13-bit sinusoid-Barker coded excitation. The amplitude and polarity of the wave packet filtered from the collected MAET signal can be used to achieve the conductivity derivative at the tissue boundary. In this study, we apply the sinusoid-Barker coded modulation method and the mismatched suppression scheme to MAET measurement to ensure the safety for biological tissues with improved SNR and spatial resolution, and suggest the potential applications in biomedical imaging. 展开更多
关键词 magneto-acousto-electrical tomography sinusoid-Barker coded excitation mismatched compression filter side lobe suppression
下载PDF
Characterization and analysis of coded excitation ultrasound parameters for rock properties 被引量:2
3
作者 ZHU Wei WU Hezhen 《Chinese Journal of Acoustics》 CSCD 2017年第1期29-42,共14页
Coded excitation technology (CET) can effectively enhance the penetration and resolution of ultrasonic testing. To analyze the influence of rock properties on pulse compression performance (PCP) of coded excitatio... Coded excitation technology (CET) can effectively enhance the penetration and resolution of ultrasonic testing. To analyze the influence of rock properties on pulse compression performance (PCP) of coded excitation signals (CES), a numerical simulation, and an ultrasonic experiment on different rock samples are performed; and the detection ability of several CESs are also investigated and compared. The results of experiments showed that the loss of the signal-to-noise ratio (SNR) of Barker coded signal with tapered linear frequency modulated carrier (BTLFM) is always less than Barker coded signal with sine carrier (BS), while the resolution loss of BTLFM is lower than tapered linear frequency modulated signal (TLFM). In sum, the results not only verifiy the effectiveness of CET, but also provide a basis for the parameter settings of coded signals used in rock ultrasonic testing. 展开更多
关键词 ROCK Characterization and analysis of coded excitation ultrasound parameters for rock properties
原文传递
A Novel Frame Error Concealment Scheme Based on Gain Control for TCX Audio Codec
4
作者 XIANG Kai HU Ruimin 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2016年第2期133-138,共6页
A novel frame error concealment scheme is proposed to improve the decoded audio quality of the receiver for transform coded excitation(TCX)audio codec.This scheme,which is a gain control approach based on the stabil... A novel frame error concealment scheme is proposed to improve the decoded audio quality of the receiver for transform coded excitation(TCX)audio codec.This scheme,which is a gain control approach based on the stability of linear predictive coding(LPC)filter,predicts the lost frames by utilizing the linear spectrum frequency and different continuous attenuation factor of different kinds of lost frames.Signal noise ratio(SNR)test and multiple stimuli with hidden reference and anchor(MUSHRA)test are conducted to evaluate the performance of this approach in adaptive multi-rate wideband plus(AMR-WB+)audio codec.Compared with the original frame error concealment scheme,our scheme achieves better audio recovery quality in AMR-WB+audio codec. 展开更多
关键词 frame error concealment audio codec transform coded excitation (TCX)
原文传递
A speech coding algorithm based on harmonic-stochastic excitation
5
作者 DING Qinghai, CAO Tieyong, ZAHNG Xiongwei, CHEN Xianzhi (Institute of Communication Engineering Nanjing Nanjing 210016) 《Chinese Journal of Acoustics》 2001年第3期250-256,共7页
A very low bit rate algorithm for encoding speech signals at 825 bps based on a mixed harmonic and stochastic modeling of the excitation signal is presented. The algorithm is more robust in the V/UV decision, reliable... A very low bit rate algorithm for encoding speech signals at 825 bps based on a mixed harmonic and stochastic modeling of the excitation signal is presented. The algorithm is more robust in the V/UV decision, reliable pitch estimation, and excitation signals synthesis. The bit allocation schedules in every case and the analysis-by-synthesis processes of the parameters are also described. The Diagnostic Rhyme Test (DRT) results show that the performance of the proposed algorithm is comparable to that of the MELP algorithm at 2.4 kbps, and the speech distinctness is 90.25%. 展开更多
关键词 LSP code A speech coding algorithm based on harmonic-stochastic excitation UV
原文传递
上一页 1 下一页 到第