期刊文献+
共找到16篇文章
< 1 >
每页显示 20 50 100
Direction and polarization estimation for coherent sources using vector sensors 被引量:3
1
作者 Jun Liu Zheng Liu Qin Liu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2013年第4期600-605,共6页
A two-dimensional direction-of-arrival (DOA) and polarization estimation algorithm for coherent sources using a linear vector-sensor array is presented. Two matrices are first constructed by the receiving data. The ... A two-dimensional direction-of-arrival (DOA) and polarization estimation algorithm for coherent sources using a linear vector-sensor array is presented. Two matrices are first constructed by the receiving data. The ranks of the two matrices are only related to the DOAs of the sources and independent of their coherency. Then the source’s elevation is resolved via the matrix pencil (MP) method, and the singular value decomposition (SVD) is used to reduce the noise effect. Finally, the source’s steering vector is estimated, and the analytics solutions of the source’s azimuth and polarization parameter can be directly computed by using a vector cross-product estimator. Moreover, the proposed algorithm can achieve the unambiguous direction estimates, even if the space between adjacent sensors is larger than a half-wavelength. Theoretical and numerical simulations show the effectiveness of the proposed algorithm. 展开更多
关键词 vector sensor coherent source direction-of-arrival (DOA) POLARIZATION matrix pencil (MP).
下载PDF
Fast parallel factor decomposition technique for coherently distributed source localization 被引量:2
2
作者 CHENG Qianlin ZHANG Xiaofei CAO Renzheng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2018年第4期667-675,共9页
This paper links parallel factor(PARAFAC) analysis to the problem of nominal direction-of-arrival(DOA) estimation for coherently distributed(CD) sources and proposes a fast PARAFACbased algorithm by establishing... This paper links parallel factor(PARAFAC) analysis to the problem of nominal direction-of-arrival(DOA) estimation for coherently distributed(CD) sources and proposes a fast PARAFACbased algorithm by establishing the trilinear PARAFAC model.Relying on the uniqueness of the low-rank three-way array decomposition and the trilinear alternating least squares regression, the proposed algorithm achieves nominal DOA estimation and outperforms the conventional estimation of signal parameter via rotational technique CD(ESPRIT-CD) and propagator method CD(PM-CD)methods in terms of estimation accuracy. Furthermore, by means of the initialization via the propagator method, this paper accelerates the convergence procedure of the proposed algorithm with no estimation performance degradation. In addition, the proposed algorithm can be directly applied to the multiple-source scenario,where sources have different angular distribution shapes. Numerical simulation results corroborate the effectiveness and superiority of the proposed fast PARAFAC-based algorithm. 展开更多
关键词 source localization coherently distributed (CD)source parallel factor analysis propagator method (PM) trilin-ear decomposition
下载PDF
Application of a Discrete Phase-Randomized Coherent State Source in Round-Robin Differential Phase-Shift Quantum Key Distribution
3
作者 张莹莹 鲍皖苏 +3 位作者 李宏伟 周淳 汪洋 江木生 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第8期16-20,共5页
Recently, a novel kind of quantum key distribution called the round-robin differential phase-shift (RRDPS) protocol was proposed, which bounds the amount of leakage without monitoring signal disturbance. The protoco... Recently, a novel kind of quantum key distribution called the round-robin differential phase-shift (RRDPS) protocol was proposed, which bounds the amount of leakage without monitoring signal disturbance. The protocol can be implemented by a weak coherent source. The security of this protocol with a simply characterized source has been proved. The application of a common phase shift can improve the secret key rate of the protocol. In practice, the randomized phase is discrete and the secret key rate is deviated from the continuous case. In this study, we analyze security of the RRDPS protocol with discrete-phase-randomized coherent state source and bound the secret key rate. We fix the length of each packet at 32 and 64, then simulate the secret key rates of the RRDPS protocol with discrete-phase randomization and continuous-phase randomization. Our simulation results show that the performance of the discrete-phase randomization case is close to the continuous counterpart with only a small number of discrete phases. The research is practically valuable for experimental implementation. 展开更多
关键词 Application of a Discrete Phase-Randomized coherent State source in Round-Robin Differential Phase-Shift Quantum Key Distribution
下载PDF
Novel algorithm on DOA estimation for correlated sources under complex symmetric Toeplitz noise 被引量:2
4
作者 Wang Kai Zhang Yongshun Shi Dan 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第5期902-906,共5页
To cope with the scenario where both uncorrelated sources and coherent sources coexist, a novel algorithm to direction of arrival (DOA) estimation for symmetric uniform linear array is presented. Under the condition... To cope with the scenario where both uncorrelated sources and coherent sources coexist, a novel algorithm to direction of arrival (DOA) estimation for symmetric uniform linear array is presented. Under the condition of stationary colored noise field, the algorithm employs a spatial differencing method to eliminate the noise covariance matrix and uncorrelated sources, then a Toeplitz matrix is constructed for the remained coherent sources. After preprocessing, a propagator method (PM) is employed to find the DOAs without any eigendecomposition. The number of sources resolved by this approach can exceed the number of array elements at a lower computational complexity. Simulation results demonstrate the effectiveness and efficiency of the proposed method. 展开更多
关键词 DOA estimation coherent source differencing toeplitz matrix propagator method.
下载PDF
Coherent free-electron light sources
5
作者 Dongdong Zhang Yushan Zeng +1 位作者 Ye Tian Ruxin Li 《Photonics Insights》 2023年第3期46-74,共29页
Free-electron light sources feature extraordinary luminosity,directionality,and coherence,which has enabled significant scientific progress in fields including physics,chemistry,and biology.The next generation of ligh... Free-electron light sources feature extraordinary luminosity,directionality,and coherence,which has enabled significant scientific progress in fields including physics,chemistry,and biology.The next generation of light sources has aimed at compact radiation sources driven by free electrons,with the advantages of reduction in both space and cost.With the rapid development of ultra-intense and ultrashort lasers,great effort has been devoted to the quest for compact free-electron lasers(FELs).This review focuses on the current efforts and advancements in the development of compact FELs,with a particular emphasis on two notable paths:the development of compact accelerators and the construction of micro undulators based on innovative materials/structures or optical modulation of electrons.In addition,the physical essence of inverse Compton scattering is discussed,which offers remarkable capability to develop an optical undulator with a spatial period that matches the optical wavelength.Recent scientific developments and future directions for miniaturized and integrated free-electron coherent light sources are also reviewed.In the future,the prospect of generating ultrashort electron pulses will provide fascinating means of producing superradiant radiation,promising high brilliance and coherence even on a micro scale using optical micro undulators. 展开更多
关键词 free-electron laser stimulated emission micro undulator coherent free-electron light source
原文传递
DOA estimation of wideband signals based on iterative spectral reconstruction 被引量:4
6
作者 Shun He Zhiwei Yang Guisheng Liao 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2017年第6期1039-1045,共7页
In order to solve the problem of coherent signal subspace method(CSSM) depending on the estimated accuracy of signal subspace, a new direction of arrival(DOA) estimation method of wideband source, which is based on it... In order to solve the problem of coherent signal subspace method(CSSM) depending on the estimated accuracy of signal subspace, a new direction of arrival(DOA) estimation method of wideband source, which is based on iterative adaptive spectral reconstruction, is proposed. Firstly, the wideband signals are divided into several narrowband signals of different frequency bins by discrete Fourier transformation(DFT). Then, the signal matched power spectrum in referenced frequency bins is computed, which can form the initial covariance matrix. Finally, the linear restrained minimum variance spectral(Capon spectral) of signals in other frequency bins are reconstructed using sequential iterative means, so the DOA can be estimated by the locations of spectral peaks. Theoretical analysis and simulation results show the proposed method based on the iterative spectral reconstruction for the covariance matrices of all sub-bands can avoid the problem of determining the signal subspace accurately with the coherent signal subspace method under the conditions of small samples and low signal to noise ratio(SNR), and it can also realize full dimensional focusing of different sub-band data, which can be applied to coherent sources and can significantly improve the accuracy of DOA estimation. 展开更多
关键词 direction of arrival(DOA) wideband source coherent source minimum variance spectral
下载PDF
Low-complexity 2D coherently distributed sources decoupled DOAs estimation method 被引量:12
7
作者 GUO XianSheng WAN Qun YANG WanLin LEI XueMei 《Science in China(Series F)》 2009年第5期835-842,共8页
The existing directions-of-arrival (DOAs) estimation methods for two-dimensional (2D) coherently distributed sources need one- or two-dimensional search, and the computational complexities of them are high. In add... The existing directions-of-arrival (DOAs) estimation methods for two-dimensional (2D) coherently distributed sources need one- or two-dimensional search, and the computational complexities of them are high. In addition, most of them are designed for special angular signal distribution functions. As a result, their performances will degenerate when deal with different sources with different angular signal distribution functions or unknown angular signal distribution functions. In this paper, a low-complexity decoupled DOAs estimation method without searching using two parallel uniform linear arrays (ULAs) is proposed for coherently distributed sources, as well as a novel parameter matching method. It can resolve the problems mentioned above efficiently. Simulation results validate the effectiveness of our approach. 展开更多
关键词 2D coherently distributed source uniform linear array direction-of-arrival (DOA) decoupled estimation quadric rotational invariance property (QRIP)
原文传递
Exploring new avenues in high repetition rate table-top coherent extreme ultraviolet sources 被引量:4
8
作者 Steffen Hadrich Manuel Krebs +4 位作者 Armin Hoffmann Arno Klenke Jan Rothhardt Jens Limpert Andreas Tunnermann 《Light(Science & Applications)》 SCIE EI CAS CSCD 2015年第1期231-236,共6页
The process of high harmonic generation(HHG)enables the development of table-top sources of coherent extreme ultraviolet(XUV)light.Although these are now matured sources,they still mostly rely on bulk laser technology... The process of high harmonic generation(HHG)enables the development of table-top sources of coherent extreme ultraviolet(XUV)light.Although these are now matured sources,they still mostly rely on bulk laser technology that limits the attainable repetition rate to the low kilohertz regime.Moreover,many of the emerging applications of such light sources(e.g.,photoelectron spectroscopy and microscopy,coherent diffractive imaging,or frequency metrology in the XUV spectral region)require an increase in the repetition rate.Ideally,these sources are operated with a multi-MHz repetition rate and deliver a high photon flux simultaneously.So far,this regime has been solely addressed using passive enhancement cavities together with low energy and high repetition rate lasers.Here,a novel route with significantly reduced complexity(omitting the requirement of an external actively stabilized resonator)is demonstrated that achieves the previously mentioned demanding parameters.A krypton-filled Kagome photonic crystal fiber is used for efficient nonlinear compression of 9 μJ,250 fs pulses leading to,7 μJ,31 fs pulses at 10.7 MHz repetition rate.The compressed pulses are used for HHG in a gas jet.Particular attention is devoted to achieving phase-matched(transiently)generation yielding.10^(13) photons s^(-1)(.50 μW)at 27.7 eV.This new spatially coherent XUV source improved the photon flux by four orders of magnitude for direct multi-MHZ experiments,thus demonstrating the considerable potential of this source. 展开更多
关键词 coherent extreme ultraviolet sources high average power high harmonic generation nonlinear compression ultrafast laser
原文传递
Macular Bruch's membrane defects and other myopic lesions in high myopia 被引量:5
9
作者 Li-Hui Meng Ming-Zhen Yuan +1 位作者 Xin-Yu Zhao You-Xin Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第3期466-473,共8页
AIM: To compare the ocular fundus features of highly myopic eyes with and without macular Bruch’s membrane(BM) defects and investigate the associations between macular BM defects and other myopic lesions.METHODS: Thi... AIM: To compare the ocular fundus features of highly myopic eyes with and without macular Bruch’s membrane(BM) defects and investigate the associations between macular BM defects and other myopic lesions.METHODS: This retrospective, observational case series included 262 eyes(139 patients) with high myopia(HM) refractive error ≥-6.0 diopters(D) or axial length ≥26.5 mm from March 2019 to December 2019.The patients underwent a comprehensive ophthalmic examination, including sweptsource optical coherence tomography(SS-OCT).The features of macular BM defects and other ocular fundus lesions were examined in OCT images.RESULTS: Totally 51 eyes(19.5%) were detected with macular BM defects, which were characterized by a lack of BM, retinal pigment epithelium(RPE), and an almost complete loss of photoreceptors or choriocapillaris.Eyes with macular BM defects had worse best-corrected visual acuity(BCVA) than those without(P<0.001).Dome-shaped macula(DSM, P=0.042), retinal cysts(P=0.006), choroidal neovascularization(CNV, P<0.001), choroidal defects and abnormality(P=0.003), scleral defects(P=0.015), scleral deformation(P=0.005), posterior staphyloma(P=0.011), and perforating vessels(P<0.001) occurred more frequently in eyes with macular BM defects.In multivariate analysis, the presence of macular BM defects remained the significant association with presence of DSM(P=0.013), scleral defects(P=0.015), posterior staphyloma(P=0.001), perforating vessels(P<0.001) and CNV(P=0.004).CONCLUSION: Macular BM defects has a prevalence of approximately 20% in HM and it has tight association with other myopic fundus lesions.BM might be crucial in the pathogenesis of myopic fundus lesions due to its biomechanical function.A comprehensive understanding of BM’s role is useful for further researches about myopic lesions. 展开更多
关键词 Bruch’s membrane high myopia swept source optical coherence tomography
下载PDF
Prediction of Outdoor Noise Propagation Induced By Single-Phase Power Transformers 被引量:2
10
作者 Xueyun Ruan Wei Huang +1 位作者 Linke Zhang Yan Gao 《Sound & Vibration》 2019年第1期2-13,共12页
Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and contr... Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers. 展开更多
关键词 Single-phase transformer surface vibration scale model noise prediction coherent image source method
下载PDF
Two-pion interferometry for a partially coherent evolution source
11
作者 李建伟 于莉莉 张卫宁 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第2期120-125,共6页
We give the formulas of two-pion Hanbury-Brown-Twiss (HBT) correlation function for a partially coherent evolution pion-emitting source, using quantum probability amplitudes in a path-integral formalism. The multipl... We give the formulas of two-pion Hanbury-Brown-Twiss (HBT) correlation function for a partially coherent evolution pion-emitting source, using quantum probability amplitudes in a path-integral formalism. The multiple scattering of the particles in the source is taken into consideration based on Glauber scattering theory. Two-pion interferometry with effects of the multiple scattering and source collective expansion is examined for a partially coherent source of hadronic gas with a finite baryon density and evolving hydrodynamically. We do not find observable effect of either the multiple scattering or the source collective expansion on HBT chaotic parameter. 展开更多
关键词 HBT correlation function partially coherent evolution source multiple scattering source collective expansion
原文传递
Anterior and posterior segment structural features of acute primary angle-closure eyes:date based on AS-OCT and SS-OCT
12
作者 Wenbin Huang Xingyi Li +1 位作者 Xinbo Gao Xiulan Zhang 《Annals of Eye Science》 2020年第4期41-49,共9页
Background:To measure the anterior and posterior segment structural features of acute primary angle-closure(APAC)eyes.Methods:A total of 36 subjects with unilateral APAC were recruited in this study.The ocular biometr... Background:To measure the anterior and posterior segment structural features of acute primary angle-closure(APAC)eyes.Methods:A total of 36 subjects with unilateral APAC were recruited in this study.The ocular biometric characteristics were measured by anterior segment optical coherence tomography(AS-OCT)and swept source optical coherence tomography(SS-OCT),respectively at baseline,2 weeks,and 1 month after surgical intervention.Results:At baseline,when compared with the fellow eyes,APAC-affected eyes showed significantly greater corneal thickness(P=0.004),shallower anterior chamber depth(ACD)(P<0.001),smaller anterior chamber area(ACA)(P=0.013),angle opening distance at 750μm from the scleral spur(AOD750)(P=0.002),trabecular-iris space area at 750μm from the scleral spur(TISA750)(P=0.033),angle recess area(ARA)(P=0.014),and iris area(IARE)(P=0.003),less iris curvature(ICURVE)(P=0.003),and larger lens vault(LV)(P=0.030).After intervention,the corneal thickness was significantly decreased at 1 month(P<0.001),while ACD,ACA,and AOD750 were significantly increased at 2 weeks and 1 month(all P<0.017).Changes in ACD were correlated with decreasing LV(P<0.05).The posterior segment parameters did not change over the 4-week period.Conclusions:When compared with the fellow eyes,APAC-affected eyes had greater corneal thickness,shallower anterior chamber,narrower angle,less ICURVE,and larger LV.After intervention,the corneal thickness was decreased,while the shallower anterior chamber was relieved to some extent. 展开更多
关键词 Acute primary angle-closure anterior segment optical coherence tomography(AS-OCT) swept source optical coherence tomography(SS-OCT) ocular biometry
下载PDF
Generation of Interstellar Class Ⅱ 7_2-8_1A^+ and 7_2-8_1A^-Methanol Masers
13
作者 Han-Ping Liu Jin Sun 《Chinese Journal of Astronomy and Astrophysics》 CSCD 2007年第6期803-808,共6页
New methanol maser lines at 72 → 63A^-(86.6 GHz) and 72 → 63A^+(86.9 GHz) together with two candidate methanol maser lines at 72 → 81A-(80.99GHz) and 72→81A^+(111.29GHz) have been detected in W3(OH). W... New methanol maser lines at 72 → 63A^-(86.6 GHz) and 72 → 63A^+(86.9 GHz) together with two candidate methanol maser lines at 72 → 81A-(80.99GHz) and 72→81A^+(111.29GHz) have been detected in W3(OH). We use a pumping mechanism, i.e., methanol masers without population inversion, to explain the formation of weak methanol masers of 72 → 81A^+ and 72→ 81A^-. We explain well why the line-shape of the transition 72 → 81A^+ is not typical. A similar argument can be applied to the A-type level system 72A^-, 63A^- and 81A^-, as well as to the 72 → 81A^- 80.99 GHz masers. 展开更多
关键词 pumping mechanism -- Class II methanol sources -- maser without inversion-- coherent microwave field
下载PDF
Effect of orthokeratology on precision and agreement assessment of a new sweptsource optical coherence tomography biometer 被引量:1
14
作者 Bao Shu Fangjun Bao +6 位作者 Giacomo Savini Weicong Lu Ruixue Tu Haisi Chen Benhao Song Qinmei Wang Jinhai Huang 《Eye and Vision》 SCIE CSCD 2020年第1期119-127,共9页
Background:To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography(SS-OCT)optical biometer(OA-2000),and agreement between its measuremen... Background:To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography(SS-OCT)optical biometer(OA-2000),and agreement between its measurements and those provided by the commonly used IOLMaster based on partial coherence interferometry(PCI).Methods:This study recruited fifty-one eyes of 51 normal children(8–16 years).An operator took measurements with the two biometers.Then,a second operator took measurements with the SS-OCT biometer.After orthokeratology was performed for one month,the same operators repeated the same procedures.Axial length(AL),mean keratometry(Km)at 2.5 mm and 3.0 mm diameters(Km2.5 and Km3.0),central corneal thickness(CCT),anterior chamber depth(ACD),lens thickness(LT)and corneal diameter(CD)were analyzed.Results:With the SS-OCT optical biometer,the test-retest repeatability of AL measurements was<0.06 mm.For all parameters,the coefficients of variation were<1.23%and the intraclass correlation coefficients were>0.95.The 95%limits of agreement of difference between the two devices for CD parameter were up to 1.53 mm.After orthokeratology,the fluctuation ranges of difference for Km3.0 measurement was 1.11 times higher than before orthokeratology,while the absolute values of difference for AL,Km2.5,ACD and CD measurements were comparable.Conclusions:Before and after orthokeratology,the SS-OCT biometer showed high repeatability and reproducibility for all measurements.Wearing orthokeratology contact lenses affected the agreement between SS-OCT and PCI biometers for Km3.0 measurements.The CD measurement showed poor agreement between the two devices. 展开更多
关键词 Swept source optical coherence tomography ORTHOKERATOLOGY PRECISION AGREEMENT CHILDREN
原文传递
THE COMPUTATION OF PARTIAL COHERENCE FUNCTION APPLIED FOR SOUND SOURCE IDENTIFICATION
15
《Chinese Journal of Acoustics》 1989年第3期254-260,共7页
In this paper, a new method is applied to get the computation formula of partial coherence function. The main attention is paid to the computation formula of the partial coherence function with three and four signals.... In this paper, a new method is applied to get the computation formula of partial coherence function. The main attention is paid to the computation formula of the partial coherence function with three and four signals. The advantages of the method discussed in the paper are clear in physical meaning and easy to compute at the end of the paper,the application of the method to the identification of an air compressor noise source is presented and the results are satisfactory. 展开更多
关键词 THE COMPUTATION OF PARTIAL COHERENCE FUNCTION APPLIED FOR SOUND source IDENTIFICATION
原文传递
Isolator-free unidirectional thulium-doped fiber laser 被引量:1
16
作者 Svyatoslav Kharitonov Camille-Sophie Bres 《Light(Science & Applications)》 SCIE EI CAS CSCD 2015年第1期163-170,共8页
We report the first demonstration of a unidirectional,isolator-free 2-μm thulium-doped fiber(TDF)laser,relying on the properties of the theta cavity(ring resonator with S-shaped feedback).The core pumped theta cavity... We report the first demonstration of a unidirectional,isolator-free 2-μm thulium-doped fiber(TDF)laser,relying on the properties of the theta cavity(ring resonator with S-shaped feedback).The core pumped theta cavity TDF laser provides sub-Watt output power with a slope efficiency of 25%,a 2 dB flat tuning range of 1900–2050 nm,and a linewidth of 0.2 nm,and achieves the extinction ratio of 18–25 dB(depending on the feedback value)between the favored and suppressed lasing directions.It is shown that these characteristics are competitive with,if not superior to,those of conventional ring cavities.The simulation results of the linear and Kerr-nonlinear theta cavities are also presented,explaining certain unexpected features of the laser behavior and establishing the importance of the doped fiber nonlinearity on the spectral shaping of the emitted signal. 展开更多
关键词 :fiber laser nonlinear amplifying loop mirror short-wave infrared coherent sources thulium-doped fiber
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部