By analyzing the subtropics aquaculture present situation,the necessity of the construction of cold disaster early warning system for subtropics aquaculture,the research goal and the duty were expounded. The system st...By analyzing the subtropics aquaculture present situation,the necessity of the construction of cold disaster early warning system for subtropics aquaculture,the research goal and the duty were expounded. The system structure and the frame were introduced in detail. Several key questions and their solutions of the cold disaster early warning system for subtropics aquaculture were put forward.展开更多
[Objective] The aim was to explore climatic characteristics of cold and frost disaster and the effects on flowers and trees in mountain city in 2010. [Method] Extremism of cold and frost disaster in temperature and la...[Objective] The aim was to explore climatic characteristics of cold and frost disaster and the effects on flowers and trees in mountain city in 2010. [Method] Extremism of cold and frost disaster in temperature and lasting period, and the effects on flowers and trees in 2010 were researched based on information of average ten-day temperatures and extreme lowest temperature in 1951-2010 and Michelia alba DC. growth in a Hou in 2008-2010, as per statistical analysis technique. [Result] Cold and frost disaster in winter of 2010 proved the longest in lasting period, lowest in average temperature, and most serious for flowers and trees, resulting in serious loss of flowers and trees in Beibei area. [Conclusion] Countermeasures in the research would reduce owners’ loss in flowers and trees.展开更多
Regarding the lack of cold source for underground cooling systems from either mine inflow or return air, field experiments were taken in a high temperature deep coal mine with abundant cold source from surface water. ...Regarding the lack of cold source for underground cooling systems from either mine inflow or return air, field experiments were taken in a high temperature deep coal mine with abundant cold source from surface water. Taking Sanhejian coal mine as an example, this paper introduced the technology scheme of heat disaster governance using surface water cold source. The paper presents the basics of this field experiment at the beginning, following by the design and site layout of the cooling system including the analysis and calculation of cold source. Numerical calculation method is also applied based on the operation parameters to simulate the influence to the surface river ecosystem. The results suggest that the temperature of surface water shall be lower than 34 ℃ after heat exchange, and when more cooling capacities are needed in the future, increasing the water flow is more favorable than increasing the cooling range of water, which is better for the ecological environment protection,展开更多
With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the ...With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy.展开更多
基金Supported by National Scientific Department National Science and Technology Supporting Plan Scheme (2008BADB9B05-02)Guangdong Science Technology Plan Program (2010B010600037)Guangdong Ocean University Personnel Project (0512049)~~
文摘By analyzing the subtropics aquaculture present situation,the necessity of the construction of cold disaster early warning system for subtropics aquaculture,the research goal and the duty were expounded. The system structure and the frame were introduced in detail. Several key questions and their solutions of the cold disaster early warning system for subtropics aquaculture were put forward.
文摘[Objective] The aim was to explore climatic characteristics of cold and frost disaster and the effects on flowers and trees in mountain city in 2010. [Method] Extremism of cold and frost disaster in temperature and lasting period, and the effects on flowers and trees in 2010 were researched based on information of average ten-day temperatures and extreme lowest temperature in 1951-2010 and Michelia alba DC. growth in a Hou in 2008-2010, as per statistical analysis technique. [Result] Cold and frost disaster in winter of 2010 proved the longest in lasting period, lowest in average temperature, and most serious for flowers and trees, resulting in serious loss of flowers and trees in Beibei area. [Conclusion] Countermeasures in the research would reduce owners’ loss in flowers and trees.
基金supported by the Key Project of National Natural Science Foundation‘‘Deep Heat Governance and Utilization’’(No.51134005)the Doctoral Fund of Ministry of Education(No.20120023120004)
文摘Regarding the lack of cold source for underground cooling systems from either mine inflow or return air, field experiments were taken in a high temperature deep coal mine with abundant cold source from surface water. Taking Sanhejian coal mine as an example, this paper introduced the technology scheme of heat disaster governance using surface water cold source. The paper presents the basics of this field experiment at the beginning, following by the design and site layout of the cooling system including the analysis and calculation of cold source. Numerical calculation method is also applied based on the operation parameters to simulate the influence to the surface river ecosystem. The results suggest that the temperature of surface water shall be lower than 34 ℃ after heat exchange, and when more cooling capacities are needed in the future, increasing the water flow is more favorable than increasing the cooling range of water, which is better for the ecological environment protection,
基金Financial supports for this project, provided by the key program supported by the National Natural Science Foundation of China(No. 51134005)the Doctoral Scientific Fund Project of the Ministry of Education of China (No. 20120023120004), are gratefully acknowledged
文摘With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy.