期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Model test study of frost heaving pressures in tunnels excavated in fractured rock mass in cold regions 被引量:2
1
作者 Bing Sun 《Research in Cold and Arid Regions》 2010年第5期405-410,共6页
Based on the similarity theory, taking the horseshoe, city-gate and round linings as examples, the value and distribution regularities of normal frost heaving pressures (hereinafter as frost heaving pressures) in tu... Based on the similarity theory, taking the horseshoe, city-gate and round linings as examples, the value and distribution regularities of normal frost heaving pressures (hereinafter as frost heaving pressures) in tunnels excavated in fractured rock mass in cold regions under different constraints and freezing depths were studied by a test model. It was found that the larger the frozen depth, the larger the frost heaving pressure, and the stronger the top constraint, the larger the frost heaving pressure. For the horseshoe lining and city-gate lining, the top constraint has a greater effect on the frost heaving pressures on the arch and the inverted arch. For the round lining, the influences of the top constraint on the frost heaving pressure in all linings are almost the same. The frost heaving pressure is maximum on the city-gate lining and minimal on the round lining. The largest frost heaving pressure all occur near the foot of the inverted arch for the three kinds of lining. Thus, the test data basically coincide with the observed in situ data. 展开更多
关键词 tunnel in cold region fractured rock mass frost heaving pressure model test
下载PDF
Numerical Calculations and Cold Tests for Flow Fields of a 220t/h Retrofitted Oil-Boiler
2
作者 朱世钧 程永元 +1 位作者 蔡崧 肖军 《Journal of Southeast University(English Edition)》 EI CAS 2000年第1期70-74,共5页
In this paper, cold simulation experiments and numerical calculations are conducted to predict 3 D flow field aerodynamics for an oil furnace after being retrofitted due to its fuel variation. K ε model and SIMPLE ... In this paper, cold simulation experiments and numerical calculations are conducted to predict 3 D flow field aerodynamics for an oil furnace after being retrofitted due to its fuel variation. K ε model and SIMPLE program under body fit coordination (BFC) system, in which TTM non orthogonal method is used to control the irregular geometric boundary, are adopted to solve the control equations. Model tests are conducted to check the calculation results, showing that they are in agreement with each other. Three different alternatives with different side window locations are also calculated to optimize the designs. The field retrofitting results show that the combination of cold tests with numerical calculations has prosperous application in retrofitting or renewing medium and small boilers. 展开更多
关键词 cold model test numerical calculation BFC boiler retrofitting
下载PDF
上一页 1 下一页 到第