The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems.This paper investigated the coupling performance of a cogeneration heating and p...The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems.This paper investigated the coupling performance of a cogeneration heating and power system multidimensionally based on the operating characteristics of the cogeneration units,the hydraulic and thermodynamic characteristics of the heating network,and the energy loads.Taking a steam network supported by a gas-steam combined cycle cogeneration system as the research case,the interaction effect among the source-side prime movers,the heating networks,and the terminal demand thermal parameters were investigated based on the designed values,the plant testing data,and the validated simulation.The operating maps of the gas-steam combined cycle cogeneration units were obtained using THERMOFLEX,and the minimum source-side steam parameters of the steam network were solved using an inverse solution procedure based on the hydro-thermodynamic coupling model.The cogeneration operating maps indicate that the available operating domain considerably narrows with the rise of the extraction steam pressure and flow rate.The heating network inverse solution demonstrates that the source-side steam pressure and temperature can be optimized from the originally designed 1.11 MPa and 238.8°C to 1.074 MPa and 191.15°C,respectively.Under the operating strategy with the minimum source-side heating parameters,the power peak regulation depth remarkably increases to 18.30%whereas the comprehensive thermal efficiency decreases.The operation under the minimum source-side heating steam parameters can be superior to the originally designed one in the economy at a higher price of the heating steam.At a fuel price of$0.38/kg and the power to fuel price of 0.18 kg/(kW·h),the critical price ratio of heating steam to fuel is 119.1 kg/t.The influence of the power-fuel price ratio on the economic deviation appears relatively weak.展开更多
The formation of ice on the leading edge of aircraft engines is a serious issue,as it can have catastrophic consequences.The Swirl Anti-Icing(SAI)system,driven by ejection,circulates hot fluid within a 360°annula...The formation of ice on the leading edge of aircraft engines is a serious issue,as it can have catastrophic consequences.The Swirl Anti-Icing(SAI)system,driven by ejection,circulates hot fluid within a 360°annular chamber to heat the engine inlet lip surface and prevent icing.This study employs a validated Computational Fluid Dynamics(CFD)approach to study the impact of key geometric parameters of this system on flow and heat transfer characteristics within the anti-icing chamber.Additionally,the entropy generation rate and exergy efficiency are analyzed to assess the energy utilization in the system.The research findings indicate that,within the considered flow range,reducing the nozzle specific areaφfrom 0.03061 to 0.01083 can enhance the ejection coefficient by over 60.7%.This enhancement increases the air circulating rate,thereby intensifying convective heat transfer within the SAI chamber.However,the reduction inφalso leads to a significant increase in the required bleed air pressure and a higher entropy generation rate,indicating lower exergy efficiency.The nozzle angleθnotably affects the distribution of hot and cold spots on the lip surface of the SAI chamber.Increasingθfrom 0°to 20°reduces the maximum temperature difference on the anti-icing chamber surface by 60 K.展开更多
In order for economically viable distributed generation systems for apartment buildings to spread, it is essential to develop an efficient and low-cost heat supply system. We have developed a new eogeneration system c...In order for economically viable distributed generation systems for apartment buildings to spread, it is essential to develop an efficient and low-cost heat supply system. We have developed a new eogeneration system called the Neighboring Cogeneration system (NCG). The key concept of this system is to install a heat accumulator with a hot water supply and a room heating function at each household and to connect different households by a single loop of hot water pipe. As a result, time leveling of the heat supply and heat transferring among households becomes possible. Thus, the costs of the pipe and the heat source equipment decrease. Furthermore, because all of the heat accumulators store heat, the total heat storage capacity is large enough for cogeneration to generate exhaust heat according to the electricity demand and with a high operating rate. In this paper, we report the results of the NCG system for 7 lived-in households. The controlling system worked efficiently. All of the households were able to use hot water without any difficulties. Further, we report the results of the energy saving effect of the NCG system for 50 lived-in households by means of a simulation based on the experimental results for NEXT21.展开更多
This paper describes two case studies: 1) a cogeneration system of a hospital and 2) a heat pump system installed in an aquarium that uses seawater for latent heat storage. The cogeneration system is an autonomous sys...This paper describes two case studies: 1) a cogeneration system of a hospital and 2) a heat pump system installed in an aquarium that uses seawater for latent heat storage. The cogeneration system is an autonomous system that combines the generation of electrical, heating, and cooling energies in a hospital. Cogeneration systems can provide simultaneous heating and cooling. No technical obstacles were identified for implementing the cogeneration system. The average ratio between electric and thermal loads in the hospital was suitable for the cogeneration system operation. An analysis performed for a non-optimized cogeneration system predicted large potential for energy savings and CO2 reduction. The heat pump system using a low-temperature unutilized heat source is introduced on a heat source load responsive heat pump system, which combines a load variation responsive heat pump utilizing seawater with a latent heat-storage system (ice and water slurry), using nighttime electric power to level the electric power load. The experimental coefficient of performance (COP) of the proposed heat exchanger from the heat pump system, assisted by using seawater as latent heat storage for cooling, is discussed in detail.展开更多
A set of 240 introgression lines derived from the advanced backcross population of a cross between a japonica cultivar,Xiushui 09,and an indica breeding line,IR2061,was developed to dissect QTLs affecting cold toleran...A set of 240 introgression lines derived from the advanced backcross population of a cross between a japonica cultivar,Xiushui 09,and an indica breeding line,IR2061,was developed to dissect QTLs affecting cold tolerance (CT) at seedling stage and heat tolerance (HT) at anthesis.Survival rate of seedlings (SRS) and spikelet fertility (SF),the index traits of CT and HT,showed significant differences between the two parents under stresses.A total of four QTLs (qSRS1,qSRS7,qSRS11a and qSRS11b) for CT were identified on chromosomes 1,7,11,and the Xiushui 09 alleles increased SRS at all loci except qSRS7.Four QTLs for SF were identified on chromosomes 4,5,6,and 11.These QTLs could be classified into two major types based on their behaviors under normal and stress conditions.The first was QTL expressed only under normal condition;and the second QTL was apparently stress induced and only expressed under stress.Among them,two QTLs (qSF4 and qSF6) which reduced the trait difference between heat stress and normal conditions must have contributed to HT because of their obvious contribution to trait stability,and the IR2061 allele at the qSF6 and the Xiushui 09 allele at the qSF4 improved HT,respectively.No similar QTL was found between CT at seedling stage and HT at anthesis.Therefore,it is possible to breed a new variety with CT and HT by pyramiding the favorable CT-and HT-improved alleles at above loci from Xiushui 09 and IR2061,respectively,through marker-assisted selection (MAS).展开更多
Two novel thermal cycles based on Brayton cycle and Rankine cycle are proposed, respectively, which integrate the recovery of low-level waste heat and Liquefied Nature Gas (LNG) cold energy utilization for power gen...Two novel thermal cycles based on Brayton cycle and Rankine cycle are proposed, respectively, which integrate the recovery of low-level waste heat and Liquefied Nature Gas (LNG) cold energy utilization for power generation. Cascade utilization of energy is realized in the two thermal cycles, where low-level waste heat,low-temperature exergy and pressure exergy of LNG are utilized efficiently through the system synthesis. The simulations are carried out using the commercial Aspen Plus 10.2, and the results are analyzed. Compared with the conventional Brayton cycle and Rankine cycle, the two novel cycles bring 60.94% and 60% in exergy efficiency, respectively and 53.08% and 52.31% in thermal efficiency, respectively.展开更多
The magnesium-lithium (Mg-Li) alloy exhibits two phase structures between 5.7wt% and 10.3wt% Li contents, consisting of the a (hcp) Mg-rich and the β (bcc) Li-rich phases, at room temperature. In the experimen...The magnesium-lithium (Mg-Li) alloy exhibits two phase structures between 5.7wt% and 10.3wt% Li contents, consisting of the a (hcp) Mg-rich and the β (bcc) Li-rich phases, at room temperature. In the experiment, Mg-5Li-2Zn, Mg-9Li-2Zn, Mg-16Li-2Zn, Mg-22Li-2Zn, Mg-5Li-2Zn-2Ca, Mg-9Li-2Zn-2Ca, Mg-16Li-2Zn-2Ca, and Mg-22Li-2Zn-2Ca (wt%) were melted. During the melting process, the flux, which was composed of lithium chloride (LiCl) and lithium fluoride (LiF) in the proportion of 3:1 (mass ratio) and argon gas were used to protect the alloys from oxidation. The microstructure, mechanical properties, and cold-rolling workability of the wrought alloys were studied. The crystal grain of the alloys (adding Ga) is fine . The hardness of the studied alloys decreases with an increase in element Li. The density of the studied alloys is in the range of 1.187 to 1.617 g/cm^3. The reduction of the Mg-16Li-2Zn and Mg-22Li-2Zn alloys can exceed 85% at room temperature. The Mg-9Li-2Zn-2Ca alloy was heat treated at 300℃ for 8, 12, 16, and 24 h, respectively. The optimum heat treatment of the Mg-9Li-2Zn-2Ca alloy is 300℃×12h by metallographic observation and by studying the mechanical properties of the alloys.展开更多
Deep mining is an inevitable tendency in the development of coal industry. There are many heat damage problems with the increase of mining depth. The technology of using doublet wells, together with Heat Exchange Ma...Deep mining is an inevitable tendency in the development of coal industry. There are many heat damage problems with the increase of mining depth. The technology of using doublet wells, together with Heat Exchange Machine Systems (HEMSs), to store cold energy is a key to solve the heat damage problems in deep mines. Based on the geological conditions, thermodynamic and hydraulic parameters of Jiahe Mine, the isotherms in the period of cold energy storage and refrigeration and the volumes of cold water within different temperature ranges of the cold energy storage well were numerically analyzed. The results show that 1) with the same pumped and injected water volumes, the lower the temperature of injected water is, the larger the volume.of cold water in the cold energy storage well is. With the larger volume, the effect of cold energy storage is better. 2) the larger the volumes of pumped and reinjected water frigeration is better. And 3) without disturbance, the volume and temperature of cold water in the cold energy storage well can keep unchanged or have only a little change for a long time. Therefore the technology of doublet wells for cold energy storage is feasible and the cold energy storage aquifers can meet the requirement of the technology.展开更多
The electrical and thermal performances of a simulated 60 kW Proton Exchange Membrane Fuel Cell (PEMFC) cogeneration system are first analyzed and then strategies to make the system operation stable and efficient are ...The electrical and thermal performances of a simulated 60 kW Proton Exchange Membrane Fuel Cell (PEMFC) cogeneration system are first analyzed and then strategies to make the system operation stable and efficient are developed. The system configuration is described first, and then the power response and coordination strategy are presented on the basis of the electricity model. Two different thermal models are used to estimate the thermal performance of this cogeneration system, and heat management is discussed. Based on these system designs, the 60 kW PEMFC cogeneration system is analyzed in detail. The analysis results will be useful for further study and development of the system.展开更多
To study the correlation of broiler chickens with energy intake, growth and mitochondrial function which exposed to sustained cold and heat stress and to find out the comfortable temperature, 288 broiler chickens(21-...To study the correlation of broiler chickens with energy intake, growth and mitochondrial function which exposed to sustained cold and heat stress and to find out the comfortable temperature, 288 broiler chickens(21-day with(748±26) g, 144 males and 144 females) were divided randomly into six temperature-controlled chambers. Each chamber contained six cages including eight AA broilers per cage, each cage as a repeat. After acclimation for one week(temperature, 21℃; relative humidity, 60%), the temperature of each chamber was adjusted(finished within 1 h) respectively to 10, 14, 18, 22, 26, or 30℃(RH, 60%) for a 14-day experimental period. After treatment, gross energy intake(GEI), metabolizable energy intake(MEI), the ratio of MEI/BW, metabolizability, average daily gain(ADG), the concentration of liver mitochondria protein and cytochrome c oxidase(CCO) were measured respectively. Our results confirmed that when the temperature over 26℃ for 14 days, GEI, MEI and CCO activities were decreased significantly(P〈0.05), but the concentration of liver mitochondria protein was increased and metabolizability of broilers was not influenced(P〉0.05). Compared with treatment for 14 days, the ratio of MEI/body weight(BW) were also decreased when the temperature over 26℃ after temperature stress for 7 days(P〈0.05), meanwhile mitochondrial protein concentration was increased at 10℃ and CCO activity was not affected(P〉0.05). Additionally at 22℃, the ADG reached the maximal value. When kept in uncomfortable temperatures for a long time, the ADG and CCO activities of broiler were reduced, which was accompanied by mitochondrial hyperplasia. In summary, our study focused on the performance of broilers during sustained cold and heat environmental temperatures ranging from 10 to 30℃. From the point of view of energy utilization, moreover, 22 to 26℃ is comfortable for 28–42 day s broilers. And these could provide the theoretical basis on the high efficient production.展开更多
Influence of severe cold deformation of titanium alloy Ti-1.5%A1-6.8%Mo-4.5%Fe in metastable β condition on the evolution of phase composition, microstructure, and tensile properties during continuous rapid heating w...Influence of severe cold deformation of titanium alloy Ti-1.5%A1-6.8%Mo-4.5%Fe in metastable β condition on the evolution of phase composition, microstructure, and tensile properties during continuous rapid heating was studied. As-deformed alloy was characterized by quasi-amorphous single-phase β condition with an abnormal temperature dependence of electric resistance that was normalized after 48 h exposure at room temperature as a result of isothermal ω phase precipitation. Subsequent rapid heating with a rate of 5 ℃/s caused recovery and recrystallization. Tensile properties of the alloy after different treatments were determined and discussed.展开更多
With the means of electron backscattered diffraction(EBSD),mechanical properties test and digital eddy current metal conductivity,the single crystal copper cold-welded joint was tested and analyzed,the structure chang...With the means of electron backscattered diffraction(EBSD),mechanical properties test and digital eddy current metal conductivity,the single crystal copper cold-welded joint was tested and analyzed,the structure change of cold-welded joint and the effect of heat treating on the structure and property of cold-welded joint were discussed.The results show that:The deformation area of the single crystal copper cold welded joint is broken,the crystalline grain at the interface of the joint is refined,and the single crystal structure is still maintained in the base metal area.The hardness of the deformation area increases greatly,the conductivity of the joint does not change much,and the tensile strength of the joint reaches about 70%of that of the base metal.At the interface of the heat treating joint,the single crystal structure of the deformation area and the base metal area are destroyed,and the grains grow up at the interface and the orientation is different.The hardness of the joint interface is much lower than that of the non-heat treating joint,the electrical conductivity of the joint is good,and the tensile strength of the joint is higher than that of the base metal.展开更多
Sealing quality strongly affects heat pipe performance, but few studies focus on the process of heat pipe sealing. Cold welding sealing technology based on a stamping process is applied for heat pipe sealing. The bond...Sealing quality strongly affects heat pipe performance, but few studies focus on the process of heat pipe sealing. Cold welding sealing technology based on a stamping process is applied for heat pipe sealing. The bonding mechanism of the cold welding sealing process (CWSP) is investigated and compared with the experimental results obtained from the bonding interface analysis. An orthogonal experiment is conducted to observe the effects of various parameters, including the sealing gap, sealing length, sealing diameter, and sealing velocity on bonding strength. A method with the utilization of saturated vapor pressure inside a copper tube is proposed to evaluate bonding strength. A corresponding finite element model is developed to investigate the effects of sealing gap and sealing velocity on plastic deformation during the cold welding process. Effects of various parameters on the bonding strength are determined and it is found that the sealing gap is the most critical factor and that the sealing velocity contributes the least effect. The best parameter combination (AIB3CID3, with a 0.5 mm sealing gap, 6 mm sealing length, 3.8 mm sealing diameter, and 50 mm/s sealing velocity) is derived within the experimental parameters. Plastic deformation results derived from the finite element model are consistent with those from the experiment. The instruction for the CWSP of heat pipes and the design of sealing dies of heat pipes are provided.展开更多
A promising solid-state coating mechanism based on the cold spray technique provides highly advantageous conditions on thermal-sensitive magnesium alloys.To study the effect of heat balance in cold spray coating on mi...A promising solid-state coating mechanism based on the cold spray technique provides highly advantageous conditions on thermal-sensitive magnesium alloys.To study the effect of heat balance in cold spray coating on microstructure,experiments were designed to successfully coat AA7075 on AZ31B with two different heat balance conditions to yield a coated sample with tensile residual stress and a sample with compressive residual stress in both coating and substrate.The effects of coating temperature on the microstructure of magnesium alloy and the interfaces of coated samples were then analyzed by SEM,EBSD,TEM in high-and low-heat input coating conditions.The interface of the AA7075 coating and magnesium alloy substrate under both conditions consists of a narrow-band layer with very fine grains,followed by columnar grains of magnesium that have grown perpendicular to the interface.At higher temperatures,this layer became wider.No intermetallic phase was detected at the interface under either condition.It is shown that the microstructure of the substrate was affected by coating temperature,leading to stress relief,dynamic recrystallization and even dynamic grain growth of magnesium under high temperature.Reducing the heat input and increasing the heat transfer decreased microstructural changes in the substrate.展开更多
The therapeutic actions of Qing Luo Yin (QLY清络饮) with heat property and Wen Luo Yin (WLY温络饮) with cold property on pain, swelling of the ankle, arthritis index and ultrastructures of synoviocytes were compared i...The therapeutic actions of Qing Luo Yin (QLY清络饮) with heat property and Wen Luo Yin (WLY温络饮) with cold property on pain, swelling of the ankle, arthritis index and ultrastructures of synoviocytes were compared in rats of type II collagen-induced arthritis (CIA), with tripterygium glycosidorum (TG) used as control. The results indicated that both QLY and WLY could reduce pain, swelling of the ankle and the arthritis index of CIA, and QLY had better effects in reducing the swelling of the ankle and controlling the secondary pathological lesions as compared with WLY. Investigation on the ultrastructures of synoviocytes indicated that both QLY and WLY could reduce the number of Golgi apparatus, rough surface endoplasmic reticulum, dense bodies, matrix filaments and vacuoles so as to suppress the excessive secretion of synoviocytes in rats of CIA.展开更多
The quality of micro heat pipe(MHP) is strongly affected by sealing technology. Based on the analysis of requirements of sealing technology, a cold welding technology was presented to seal MHP. In the cold welding pro...The quality of micro heat pipe(MHP) is strongly affected by sealing technology. Based on the analysis of requirements of sealing technology, a cold welding technology was presented to seal MHP. In the cold welding process, compression force was used to flatten micro groove copper(MGC) tube. Then the bonding of MGC tube was reached because of intensively plastic deformation of MGC tube under pressure. It is found that the plastic deformation area of the cold welding of MGC tube can be divided into three sections. The deformation of micro grooves in each section was investigated; the influence of the dimensions of cylindrical heads on the weld joint shape and strength was studied; and a comparison between smooth copper tube and MGC tube was done. The results show that a groove compression stage exists in the cold welding of MGC tube besides a flattened stage and a melting stage.展开更多
The electromotive force (EMF) changes in type K heavy gauge sheathed thermocouple cables was investigated. To cope with this discrepancy owing to EMF steep reduction and understand the difference between type K heavy ...The electromotive force (EMF) changes in type K heavy gauge sheathed thermocouple cables was investigated. To cope with this discrepancy owing to EMF steep reduction and understand the difference between type K heavy gauge sheathed thermocouple cables and small ones, the affects of EMF from sheath pipe, drawing times, annealing temperature, annealing time and annealing way were mainly studied and appropriately analyzed. The results show the change in the thermal EMF is related with the residual stress and crystal defects, which are imparted by cold work during manufacture. The affects of cold work can be removed by annealing. Finally, a feasible way of fabricating heavy gauge sheathed thermocouples was suggested according to practical situation.展开更多
The effect of vacuum heat treatment on the microstructure and microhardness of cold-sprayed Cu-4%Cr-2%Nb alloy coating was investigated. The heat treatment was conducted under the temperatures from 250 ℃ to 950 ℃ wi...The effect of vacuum heat treatment on the microstructure and microhardness of cold-sprayed Cu-4%Cr-2%Nb alloy coating was investigated. The heat treatment was conducted under the temperatures from 250 ℃ to 950 ℃ with a step of 100 ℃ for 2 h. It was found that a dense thick Cu-4Cr-2Nb coating could be formed by cold spraying. After heat treatment, a Cr2Nb phase was uniformly distributed in the matrix, which was transferred from the gas-atomized feedstock. A little grain growth of Cr2Nb phase was observed accompanying with the healing-up of the incomplete interfaces between the deposited particles at the elevated temperatures. The coating microhardness increases a little with increasing the temperature to 350 ℃, and then decreases with further increasing temperature up to 950 ℃. This fact can be attributed to the microstructure evolution during the heat treatment.展开更多
Recovery of waste heat from boiler flue gas is an effective way to improve energy utilization efficiency.Taking a heating station heating project as an example,the existing heating system of this heating station was a...Recovery of waste heat from boiler flue gas is an effective way to improve energy utilization efficiency.Taking a heating station heating project as an example,the existing heating system of this heating station was analyzed for its underutilized flue gas waste heat and low energy utilization rate.Rankine cycle is an effective waste heat recovery method,and a steam boiler organic Rankine cycle(ORC)cogeneration waste heat utilization method is proposed.The system model simulation is constructed and verified.First,a thermodynamic model was constructed in MATLAB and five suitable work gases were selected to analyze the effects of evaporation temperature and condensation temperature on the network and thermal efficiency of the waste heat cycle power system.Secondly,the ORC model is invoked in TRNSYS to construct the improved cogeneration system,and the rationality of the remaining heat utilization methods is determined by calculating and analyzing the thermal performance,economy,and environmental protection of the improved system.The simulation results show that the system can generate about 552,000 kWh of electricity per year,and improving the energy utilization rate from 0.72 to 0.78.展开更多
基金Guangdong Province Key Laboratory of Efficient and Clean Energy Utilization(South China University of Technology)(2013A061401005)Research Fund(JMSWFW-2110-044)from Zhongshan Jiaming Electric Power Co.,Ltd.
文摘The determination of source-side extracted heating parameters is of great significance to the economic operation of cogeneration systems.This paper investigated the coupling performance of a cogeneration heating and power system multidimensionally based on the operating characteristics of the cogeneration units,the hydraulic and thermodynamic characteristics of the heating network,and the energy loads.Taking a steam network supported by a gas-steam combined cycle cogeneration system as the research case,the interaction effect among the source-side prime movers,the heating networks,and the terminal demand thermal parameters were investigated based on the designed values,the plant testing data,and the validated simulation.The operating maps of the gas-steam combined cycle cogeneration units were obtained using THERMOFLEX,and the minimum source-side steam parameters of the steam network were solved using an inverse solution procedure based on the hydro-thermodynamic coupling model.The cogeneration operating maps indicate that the available operating domain considerably narrows with the rise of the extraction steam pressure and flow rate.The heating network inverse solution demonstrates that the source-side steam pressure and temperature can be optimized from the originally designed 1.11 MPa and 238.8°C to 1.074 MPa and 191.15°C,respectively.Under the operating strategy with the minimum source-side heating parameters,the power peak regulation depth remarkably increases to 18.30%whereas the comprehensive thermal efficiency decreases.The operation under the minimum source-side heating steam parameters can be superior to the originally designed one in the economy at a higher price of the heating steam.At a fuel price of$0.38/kg and the power to fuel price of 0.18 kg/(kW·h),the critical price ratio of heating steam to fuel is 119.1 kg/t.The influence of the power-fuel price ratio on the economic deviation appears relatively weak.
基金Shenyang Key Laboratory of Aircraft Icing and Ice Protection,Grant Number XFX20220303Education Department of Hunan Province,China,Grant Number 23A0504National Natural Science Foundation of China,Grant Number 52275108.
文摘The formation of ice on the leading edge of aircraft engines is a serious issue,as it can have catastrophic consequences.The Swirl Anti-Icing(SAI)system,driven by ejection,circulates hot fluid within a 360°annular chamber to heat the engine inlet lip surface and prevent icing.This study employs a validated Computational Fluid Dynamics(CFD)approach to study the impact of key geometric parameters of this system on flow and heat transfer characteristics within the anti-icing chamber.Additionally,the entropy generation rate and exergy efficiency are analyzed to assess the energy utilization in the system.The research findings indicate that,within the considered flow range,reducing the nozzle specific areaφfrom 0.03061 to 0.01083 can enhance the ejection coefficient by over 60.7%.This enhancement increases the air circulating rate,thereby intensifying convective heat transfer within the SAI chamber.However,the reduction inφalso leads to a significant increase in the required bleed air pressure and a higher entropy generation rate,indicating lower exergy efficiency.The nozzle angleθnotably affects the distribution of hot and cold spots on the lip surface of the SAI chamber.Increasingθfrom 0°to 20°reduces the maximum temperature difference on the anti-icing chamber surface by 60 K.
文摘In order for economically viable distributed generation systems for apartment buildings to spread, it is essential to develop an efficient and low-cost heat supply system. We have developed a new eogeneration system called the Neighboring Cogeneration system (NCG). The key concept of this system is to install a heat accumulator with a hot water supply and a room heating function at each household and to connect different households by a single loop of hot water pipe. As a result, time leveling of the heat supply and heat transferring among households becomes possible. Thus, the costs of the pipe and the heat source equipment decrease. Furthermore, because all of the heat accumulators store heat, the total heat storage capacity is large enough for cogeneration to generate exhaust heat according to the electricity demand and with a high operating rate. In this paper, we report the results of the NCG system for 7 lived-in households. The controlling system worked efficiently. All of the households were able to use hot water without any difficulties. Further, we report the results of the energy saving effect of the NCG system for 50 lived-in households by means of a simulation based on the experimental results for NEXT21.
文摘This paper describes two case studies: 1) a cogeneration system of a hospital and 2) a heat pump system installed in an aquarium that uses seawater for latent heat storage. The cogeneration system is an autonomous system that combines the generation of electrical, heating, and cooling energies in a hospital. Cogeneration systems can provide simultaneous heating and cooling. No technical obstacles were identified for implementing the cogeneration system. The average ratio between electric and thermal loads in the hospital was suitable for the cogeneration system operation. An analysis performed for a non-optimized cogeneration system predicted large potential for energy savings and CO2 reduction. The heat pump system using a low-temperature unutilized heat source is introduced on a heat source load responsive heat pump system, which combines a load variation responsive heat pump utilizing seawater with a latent heat-storage system (ice and water slurry), using nighttime electric power to level the electric power load. The experimental coefficient of performance (COP) of the proposed heat exchanger from the heat pump system, assisted by using seawater as latent heat storage for cooling, is discussed in detail.
基金funded by the Project of the 863 Program(2010AA101803)the 948 Program of China(2006-G51 and 2010-G2B)
文摘A set of 240 introgression lines derived from the advanced backcross population of a cross between a japonica cultivar,Xiushui 09,and an indica breeding line,IR2061,was developed to dissect QTLs affecting cold tolerance (CT) at seedling stage and heat tolerance (HT) at anthesis.Survival rate of seedlings (SRS) and spikelet fertility (SF),the index traits of CT and HT,showed significant differences between the two parents under stresses.A total of four QTLs (qSRS1,qSRS7,qSRS11a and qSRS11b) for CT were identified on chromosomes 1,7,11,and the Xiushui 09 alleles increased SRS at all loci except qSRS7.Four QTLs for SF were identified on chromosomes 4,5,6,and 11.These QTLs could be classified into two major types based on their behaviors under normal and stress conditions.The first was QTL expressed only under normal condition;and the second QTL was apparently stress induced and only expressed under stress.Among them,two QTLs (qSF4 and qSF6) which reduced the trait difference between heat stress and normal conditions must have contributed to HT because of their obvious contribution to trait stability,and the IR2061 allele at the qSF6 and the Xiushui 09 allele at the qSF4 improved HT,respectively.No similar QTL was found between CT at seedling stage and HT at anthesis.Therefore,it is possible to breed a new variety with CT and HT by pyramiding the favorable CT-and HT-improved alleles at above loci from Xiushui 09 and IR2061,respectively,through marker-assisted selection (MAS).
基金the Science and Technology Foundation of Shaanxi Province (No.2002K08-G9).
文摘Two novel thermal cycles based on Brayton cycle and Rankine cycle are proposed, respectively, which integrate the recovery of low-level waste heat and Liquefied Nature Gas (LNG) cold energy utilization for power generation. Cascade utilization of energy is realized in the two thermal cycles, where low-level waste heat,low-temperature exergy and pressure exergy of LNG are utilized efficiently through the system synthesis. The simulations are carried out using the commercial Aspen Plus 10.2, and the results are analyzed. Compared with the conventional Brayton cycle and Rankine cycle, the two novel cycles bring 60.94% and 60% in exergy efficiency, respectively and 53.08% and 52.31% in thermal efficiency, respectively.
文摘The magnesium-lithium (Mg-Li) alloy exhibits two phase structures between 5.7wt% and 10.3wt% Li contents, consisting of the a (hcp) Mg-rich and the β (bcc) Li-rich phases, at room temperature. In the experiment, Mg-5Li-2Zn, Mg-9Li-2Zn, Mg-16Li-2Zn, Mg-22Li-2Zn, Mg-5Li-2Zn-2Ca, Mg-9Li-2Zn-2Ca, Mg-16Li-2Zn-2Ca, and Mg-22Li-2Zn-2Ca (wt%) were melted. During the melting process, the flux, which was composed of lithium chloride (LiCl) and lithium fluoride (LiF) in the proportion of 3:1 (mass ratio) and argon gas were used to protect the alloys from oxidation. The microstructure, mechanical properties, and cold-rolling workability of the wrought alloys were studied. The crystal grain of the alloys (adding Ga) is fine . The hardness of the studied alloys decreases with an increase in element Li. The density of the studied alloys is in the range of 1.187 to 1.617 g/cm^3. The reduction of the Mg-16Li-2Zn and Mg-22Li-2Zn alloys can exceed 85% at room temperature. The Mg-9Li-2Zn-2Ca alloy was heat treated at 300℃ for 8, 12, 16, and 24 h, respectively. The optimum heat treatment of the Mg-9Li-2Zn-2Ca alloy is 300℃×12h by metallographic observation and by studying the mechanical properties of the alloys.
基金Project 50490270 supported by Key Project of National Natural Science Foundation of China
文摘Deep mining is an inevitable tendency in the development of coal industry. There are many heat damage problems with the increase of mining depth. The technology of using doublet wells, together with Heat Exchange Machine Systems (HEMSs), to store cold energy is a key to solve the heat damage problems in deep mines. Based on the geological conditions, thermodynamic and hydraulic parameters of Jiahe Mine, the isotherms in the period of cold energy storage and refrigeration and the volumes of cold water within different temperature ranges of the cold energy storage well were numerically analyzed. The results show that 1) with the same pumped and injected water volumes, the lower the temperature of injected water is, the larger the volume.of cold water in the cold energy storage well is. With the larger volume, the effect of cold energy storage is better. 2) the larger the volumes of pumped and reinjected water frigeration is better. And 3) without disturbance, the volume and temperature of cold water in the cold energy storage well can keep unchanged or have only a little change for a long time. Therefore the technology of doublet wells for cold energy storage is feasible and the cold energy storage aquifers can meet the requirement of the technology.
基金Project (No. 2002AA517020) supported by the Hi-Tech Researchand Development Program (863) of China
文摘The electrical and thermal performances of a simulated 60 kW Proton Exchange Membrane Fuel Cell (PEMFC) cogeneration system are first analyzed and then strategies to make the system operation stable and efficient are developed. The system configuration is described first, and then the power response and coordination strategy are presented on the basis of the electricity model. Two different thermal models are used to estimate the thermal performance of this cogeneration system, and heat management is discussed. Based on these system designs, the 60 kW PEMFC cogeneration system is analyzed in detail. The analysis results will be useful for further study and development of the system.
基金supported by the Key Technologies R&D Program of China during the 12th Five-Year Plan period (2012BAD39B02)the Science and Technology Innovation Team Project of Chinese Academy of Agricultural Sciences (cxgc-ias-07-2013)financial support by the State Key Laboratory of Animal Nutrition, Ministry of Science and Technology, China (2004DA125184G1105)
文摘To study the correlation of broiler chickens with energy intake, growth and mitochondrial function which exposed to sustained cold and heat stress and to find out the comfortable temperature, 288 broiler chickens(21-day with(748±26) g, 144 males and 144 females) were divided randomly into six temperature-controlled chambers. Each chamber contained six cages including eight AA broilers per cage, each cage as a repeat. After acclimation for one week(temperature, 21℃; relative humidity, 60%), the temperature of each chamber was adjusted(finished within 1 h) respectively to 10, 14, 18, 22, 26, or 30℃(RH, 60%) for a 14-day experimental period. After treatment, gross energy intake(GEI), metabolizable energy intake(MEI), the ratio of MEI/BW, metabolizability, average daily gain(ADG), the concentration of liver mitochondria protein and cytochrome c oxidase(CCO) were measured respectively. Our results confirmed that when the temperature over 26℃ for 14 days, GEI, MEI and CCO activities were decreased significantly(P〈0.05), but the concentration of liver mitochondria protein was increased and metabolizability of broilers was not influenced(P〉0.05). Compared with treatment for 14 days, the ratio of MEI/body weight(BW) were also decreased when the temperature over 26℃ after temperature stress for 7 days(P〈0.05), meanwhile mitochondrial protein concentration was increased at 10℃ and CCO activity was not affected(P〉0.05). Additionally at 22℃, the ADG reached the maximal value. When kept in uncomfortable temperatures for a long time, the ADG and CCO activities of broiler were reduced, which was accompanied by mitochondrial hyperplasia. In summary, our study focused on the performance of broilers during sustained cold and heat environmental temperatures ranging from 10 to 30℃. From the point of view of energy utilization, moreover, 22 to 26℃ is comfortable for 28–42 day s broilers. And these could provide the theoretical basis on the high efficient production.
文摘Influence of severe cold deformation of titanium alloy Ti-1.5%A1-6.8%Mo-4.5%Fe in metastable β condition on the evolution of phase composition, microstructure, and tensile properties during continuous rapid heating was studied. As-deformed alloy was characterized by quasi-amorphous single-phase β condition with an abnormal temperature dependence of electric resistance that was normalized after 48 h exposure at room temperature as a result of isothermal ω phase precipitation. Subsequent rapid heating with a rate of 5 ℃/s caused recovery and recrystallization. Tensile properties of the alloy after different treatments were determined and discussed.
文摘With the means of electron backscattered diffraction(EBSD),mechanical properties test and digital eddy current metal conductivity,the single crystal copper cold-welded joint was tested and analyzed,the structure change of cold-welded joint and the effect of heat treating on the structure and property of cold-welded joint were discussed.The results show that:The deformation area of the single crystal copper cold welded joint is broken,the crystalline grain at the interface of the joint is refined,and the single crystal structure is still maintained in the base metal area.The hardness of the deformation area increases greatly,the conductivity of the joint does not change much,and the tensile strength of the joint reaches about 70%of that of the base metal.At the interface of the heat treating joint,the single crystal structure of the deformation area and the base metal area are destroyed,and the grains grow up at the interface and the orientation is different.The hardness of the joint interface is much lower than that of the non-heat treating joint,the electrical conductivity of the joint is good,and the tensile strength of the joint is higher than that of the base metal.
基金Supported by National Natural Science Foundation of China(Grant Nos.51175186,51675185)Guangdong Provincial Natural Science Foundation of China(Grant No.S2013020012757)EU project PIIF-GA-2012-332304(Grant No.ESR332304)
文摘Sealing quality strongly affects heat pipe performance, but few studies focus on the process of heat pipe sealing. Cold welding sealing technology based on a stamping process is applied for heat pipe sealing. The bonding mechanism of the cold welding sealing process (CWSP) is investigated and compared with the experimental results obtained from the bonding interface analysis. An orthogonal experiment is conducted to observe the effects of various parameters, including the sealing gap, sealing length, sealing diameter, and sealing velocity on bonding strength. A method with the utilization of saturated vapor pressure inside a copper tube is proposed to evaluate bonding strength. A corresponding finite element model is developed to investigate the effects of sealing gap and sealing velocity on plastic deformation during the cold welding process. Effects of various parameters on the bonding strength are determined and it is found that the sealing gap is the most critical factor and that the sealing velocity contributes the least effect. The best parameter combination (AIB3CID3, with a 0.5 mm sealing gap, 6 mm sealing length, 3.8 mm sealing diameter, and 50 mm/s sealing velocity) is derived within the experimental parameters. Plastic deformation results derived from the finite element model are consistent with those from the experiment. The instruction for the CWSP of heat pipes and the design of sealing dies of heat pipes are provided.
基金The financial support of the Natural Sciences and Engineering Research Council of Canada(NSERC)through the Automotive Partnership Canada(APC)under APCPJ 459269-13 grant with contributions from Multimatic Technical centre,Ford Motor CompanyCenterline Windsor are acknowledged.Funds from NSERC-RTI program under EQPEQ458441-2014 grant also supported this research.
文摘A promising solid-state coating mechanism based on the cold spray technique provides highly advantageous conditions on thermal-sensitive magnesium alloys.To study the effect of heat balance in cold spray coating on microstructure,experiments were designed to successfully coat AA7075 on AZ31B with two different heat balance conditions to yield a coated sample with tensile residual stress and a sample with compressive residual stress in both coating and substrate.The effects of coating temperature on the microstructure of magnesium alloy and the interfaces of coated samples were then analyzed by SEM,EBSD,TEM in high-and low-heat input coating conditions.The interface of the AA7075 coating and magnesium alloy substrate under both conditions consists of a narrow-band layer with very fine grains,followed by columnar grains of magnesium that have grown perpendicular to the interface.At higher temperatures,this layer became wider.No intermetallic phase was detected at the interface under either condition.It is shown that the microstructure of the substrate was affected by coating temperature,leading to stress relief,dynamic recrystallization and even dynamic grain growth of magnesium under high temperature.Reducing the heat input and increasing the heat transfer decreased microstructural changes in the substrate.
文摘The therapeutic actions of Qing Luo Yin (QLY清络饮) with heat property and Wen Luo Yin (WLY温络饮) with cold property on pain, swelling of the ankle, arthritis index and ultrastructures of synoviocytes were compared in rats of type II collagen-induced arthritis (CIA), with tripterygium glycosidorum (TG) used as control. The results indicated that both QLY and WLY could reduce pain, swelling of the ankle and the arthritis index of CIA, and QLY had better effects in reducing the swelling of the ankle and controlling the secondary pathological lesions as compared with WLY. Investigation on the ultrastructures of synoviocytes indicated that both QLY and WLY could reduce the number of Golgi apparatus, rough surface endoplasmic reticulum, dense bodies, matrix filaments and vacuoles so as to suppress the excessive secretion of synoviocytes in rats of CIA.
基金Projects(50436010, 50705031) supported by the National Natural Science Foundation of ChinaProjects(07118064, 8151064101000058) supported by the Natural Science Foundation of Guangdong Province, China
文摘The quality of micro heat pipe(MHP) is strongly affected by sealing technology. Based on the analysis of requirements of sealing technology, a cold welding technology was presented to seal MHP. In the cold welding process, compression force was used to flatten micro groove copper(MGC) tube. Then the bonding of MGC tube was reached because of intensively plastic deformation of MGC tube under pressure. It is found that the plastic deformation area of the cold welding of MGC tube can be divided into three sections. The deformation of micro grooves in each section was investigated; the influence of the dimensions of cylindrical heads on the weld joint shape and strength was studied; and a comparison between smooth copper tube and MGC tube was done. The results show that a groove compression stage exists in the cold welding of MGC tube besides a flattened stage and a melting stage.
文摘The electromotive force (EMF) changes in type K heavy gauge sheathed thermocouple cables was investigated. To cope with this discrepancy owing to EMF steep reduction and understand the difference between type K heavy gauge sheathed thermocouple cables and small ones, the affects of EMF from sheath pipe, drawing times, annealing temperature, annealing time and annealing way were mainly studied and appropriately analyzed. The results show the change in the thermal EMF is related with the residual stress and crystal defects, which are imparted by cold work during manufacture. The affects of cold work can be removed by annealing. Finally, a feasible way of fabricating heavy gauge sheathed thermocouples was suggested according to practical situation.
文摘The effect of vacuum heat treatment on the microstructure and microhardness of cold-sprayed Cu-4%Cr-2%Nb alloy coating was investigated. The heat treatment was conducted under the temperatures from 250 ℃ to 950 ℃ with a step of 100 ℃ for 2 h. It was found that a dense thick Cu-4Cr-2Nb coating could be formed by cold spraying. After heat treatment, a Cr2Nb phase was uniformly distributed in the matrix, which was transferred from the gas-atomized feedstock. A little grain growth of Cr2Nb phase was observed accompanying with the healing-up of the incomplete interfaces between the deposited particles at the elevated temperatures. The coating microhardness increases a little with increasing the temperature to 350 ℃, and then decreases with further increasing temperature up to 950 ℃. This fact can be attributed to the microstructure evolution during the heat treatment.
基金supported by research funds from Shanghai’s 2020 Annual Science and Technology Innovation Action Plan:Social development and Science&Technology Project(No.20dz1205302).
文摘Recovery of waste heat from boiler flue gas is an effective way to improve energy utilization efficiency.Taking a heating station heating project as an example,the existing heating system of this heating station was analyzed for its underutilized flue gas waste heat and low energy utilization rate.Rankine cycle is an effective waste heat recovery method,and a steam boiler organic Rankine cycle(ORC)cogeneration waste heat utilization method is proposed.The system model simulation is constructed and verified.First,a thermodynamic model was constructed in MATLAB and five suitable work gases were selected to analyze the effects of evaporation temperature and condensation temperature on the network and thermal efficiency of the waste heat cycle power system.Secondly,the ORC model is invoked in TRNSYS to construct the improved cogeneration system,and the rationality of the remaining heat utilization methods is determined by calculating and analyzing the thermal performance,economy,and environmental protection of the improved system.The simulation results show that the system can generate about 552,000 kWh of electricity per year,and improving the energy utilization rate from 0.72 to 0.78.