In this article, principle and mathematical method of determining the phase fractions of multiphase flows by using a dual-energy γ -ray system have been described. The dual-energy γ -ray device is composed of radioa...In this article, principle and mathematical method of determining the phase fractions of multiphase flows by using a dual-energy γ -ray system have been described. The dual-energy γ -ray device is composed of radioactive isotopes of 241Am and 137Cs with γ -ray energies of 59.5 and 662 keV, respectively. A rational method to calibrate the absorption coefficient was introduced in detail. The modified arithmetic is beneficial to removing the extra Compton scattering from the measured value. The result shows that the dual-energy γ -ray technique can be used in three-phase flow with average accuracy greater than 95%, which enables us to determine phase fractions almost independent of the flow regime. Improvement has been achieved on measurement accuracy of phase fractions.展开更多
By means of a logarithm law for the velocity profile, a corrected formula of bed resistance coefficient, which involves many factors such as gradient of still water depth, variation of surface elevation, flow directio...By means of a logarithm law for the velocity profile, a corrected formula of bed resistance coefficient, which involves many factors such as gradient of still water depth, variation of surface elevation, flow direction, and so on, is derived from the 3D governing equations of tidal current by averaging over the whole water depth. Theoretical analysis and application have shown that the 2D plane tidal current numerical model would be more reasonable and could be applied to steep bottom topography when the corrected bed resistance coefficient is used, therefore the results of reproduction simulation and engineering calculation would be more scientific and reasonable.展开更多
Monitoring various internal parameters plays a core role in ensuring the safety of lithium-ion batteries in power supply applications.It also influences the sustainability effect and online state of charge prediction....Monitoring various internal parameters plays a core role in ensuring the safety of lithium-ion batteries in power supply applications.It also influences the sustainability effect and online state of charge prediction.An improved multiple feature-electrochemical thermal coupling modeling method is proposed considering low-temperature performance degradation for the complete characteristic expression of multi-dimensional information.This is to obtain the parameter influence mechanism with a multi-variable coupling relationship.An optimized decoupled deviation strategy is constructed for accurate state of charge prediction with real-time correction of time-varying current and temperature effects.The innovative decoupling method is combined with the functional relationships of state of charge and open-circuit voltage to capture energy management ef-fectively.Then,an adaptive equivalent-prediction model is constructed using the state-space equation and iterative feedback correction,making the proposed model adaptive to fractional calculation.The maximum state of charge estimation errors of the proposed method are 4.57% and 0.223% under the Beijing bus dynamic stress test and dynamic stress test conditions,respectively.The improved multiple feature-electrochemical thermal coupling modeling realizes the effective correction of the current and temperature variations with noise influencing coefficient,and provides an efficient state of charge prediction method adaptive to complex conditions.展开更多
Five phospholipids in human placenta were determined by phosphorus 31 nuclear magnetic resonance(^(31)P NMR)spectroscopy and thin-layer chromatography(TLC) scanning combined with the corrective method of absorbance pr...Five phospholipids in human placenta were determined by phosphorus 31 nuclear magnetic resonance(^(31)P NMR)spectroscopy and thin-layer chromatography(TLC) scanning combined with the corrective method of absorbance proportional coefficient. The NMR spectrometer used this investigation was a Bruker AM-500 spectrometer operating at 202.4 MHz for ^(31)P chemical shifts are relative to 85% phosphoric acid. TIC was carried out by silica gel H plate developed in chloroform-methanol-glacial acetic acid-ethanol-water(25:4:6:2:0.5),with Vaskovsky reagent as colour -developing agent of phospholipids.展开更多
The accuracy of attenuation correction in positron emission tomography scanners depends mainly on deriving the reliable 511-keV linear attenuation coefficient distribution in the scanned objects. In the PET/CT system,...The accuracy of attenuation correction in positron emission tomography scanners depends mainly on deriving the reliable 511-keV linear attenuation coefficient distribution in the scanned objects. In the PET/CT system, the linear attenu- ation distribution is usually obtained from the intensities of the CT image. However, the intensities of the CT image relate to the attenuation of photons in an energy range of 40 keV-140 keV. Before implementing PET attenuation correction, the intensities of CT images must be transformed into the PET 511-keV linear attenuation coefficients. However, the CT scan parameters can affect the effective energy of CT X-ray photons and thus affect the intensities of the CT image. Therefore, for PET/CT attenuation correction, it is crucial to determine the conversion curve with a given set of CT scan parameters and convert the CT image into a PET linear attenuation coefficient distribution. A generalized method is proposed for con- verting a CT image into a PET linear attenuation coefficient distribution. Instead of some parameter-dependent phantom calibration experiments, the conversion curve is calculated directly by employing the consistency conditions to yield the most consistent attenuation map with the measured PET data. The method is evaluated with phantom experiments and small animal experiments. In phantom studies, the estimated conversion curve fits the true attenuation coefficients accurately, and accurate PET attenuation maps are obtained by the estimated conversion curves and provide nearly the same correction results as the true attenuation map. In small animal studies, a more complicated attenuation distribution of the mouse is obtained successfully to remove the attenuation artifact and improve the PET image contrast efficiently.展开更多
The heat transfer coefficient in a multidimensional heat conduction problem is obtained from the solution of the inverse heat conduction problem based on the thermographic temperature measurement. The modified one-dim...The heat transfer coefficient in a multidimensional heat conduction problem is obtained from the solution of the inverse heat conduction problem based on the thermographic temperature measurement. The modified one-dimensional correction method (MODCM), along with the finite volume method, is employed for both two- and three-dimensional inverse problems. A series of numerical experiments are conducted in order to verify the effectiveness of the method. In addition, the effect of the temperature measurement error, the ending criterion of the iteration, etc. on the result of the inverse problem is investigated. It is proved that the method is a simple, stable and accurate one that can solve successfully the inverse heat conduction problem.展开更多
The absorption coefficient of water is an important bio-optical parameter for water optics and water color remote sensing. However, scattering correction is essential to obtain accurate absorption coefficient values i...The absorption coefficient of water is an important bio-optical parameter for water optics and water color remote sensing. However, scattering correction is essential to obtain accurate absorption coefficient values in situ using the nine-wavelength absorption and attenuation meter AC9. Establishing the correction always fails in Case 2 water when the correction assumes zero absorption in the near-infrared(NIR) region and underestimates the absorption coefficient in the red region, which affect processes such as semi-analytical remote sensing inversion. In this study, the scattering contribution was evaluated by an exponential fitting approach using AC9 measurements at seven wavelengths(412, 440, 488, 510, 532, 555, and 715 nm) and by applying scattering correction. The correction was applied to representative in situ data of moderately turbid coastal water, highly turbid coastal water, eutrophic inland water, and turbid inland water. The results suggest that the absorption levels in the red and NIR regions are significantly higher than those obtained using standard scattering error correction procedures. Knowledge of the deviation between this method and the commonly used scattering correction methods will facilitate the evaluation of the effect on satellite remote sensing of water constituents and general optical research using different scatteringcorrection methods.展开更多
基金Supported by National Natural Science Foundation of China (No.10572143) and Joint Project between the Royal Society and the Chinese Academy of Sciences (No.15933).
文摘In this article, principle and mathematical method of determining the phase fractions of multiphase flows by using a dual-energy γ -ray system have been described. The dual-energy γ -ray device is composed of radioactive isotopes of 241Am and 137Cs with γ -ray energies of 59.5 and 662 keV, respectively. A rational method to calibrate the absorption coefficient was introduced in detail. The modified arithmetic is beneficial to removing the extra Compton scattering from the measured value. The result shows that the dual-energy γ -ray technique can be used in three-phase flow with average accuracy greater than 95%, which enables us to determine phase fractions almost independent of the flow regime. Improvement has been achieved on measurement accuracy of phase fractions.
基金National Natural Science Foundation of China(Grant No.49971064)
文摘By means of a logarithm law for the velocity profile, a corrected formula of bed resistance coefficient, which involves many factors such as gradient of still water depth, variation of surface elevation, flow direction, and so on, is derived from the 3D governing equations of tidal current by averaging over the whole water depth. Theoretical analysis and application have shown that the 2D plane tidal current numerical model would be more reasonable and could be applied to steep bottom topography when the corrected bed resistance coefficient is used, therefore the results of reproduction simulation and engineering calculation would be more scientific and reasonable.
基金supported by the National Natural Science Foundation of China(No.62173281)the Natural Science Foundation of Sichuan Province(No.23ZDYF0734 and No.2023NSFSC1436)the Fund of Robot Technology Used for Special Environment Key Laboratory of Sichuan Province(No.18kftk03).
文摘Monitoring various internal parameters plays a core role in ensuring the safety of lithium-ion batteries in power supply applications.It also influences the sustainability effect and online state of charge prediction.An improved multiple feature-electrochemical thermal coupling modeling method is proposed considering low-temperature performance degradation for the complete characteristic expression of multi-dimensional information.This is to obtain the parameter influence mechanism with a multi-variable coupling relationship.An optimized decoupled deviation strategy is constructed for accurate state of charge prediction with real-time correction of time-varying current and temperature effects.The innovative decoupling method is combined with the functional relationships of state of charge and open-circuit voltage to capture energy management ef-fectively.Then,an adaptive equivalent-prediction model is constructed using the state-space equation and iterative feedback correction,making the proposed model adaptive to fractional calculation.The maximum state of charge estimation errors of the proposed method are 4.57% and 0.223% under the Beijing bus dynamic stress test and dynamic stress test conditions,respectively.The improved multiple feature-electrochemical thermal coupling modeling realizes the effective correction of the current and temperature variations with noise influencing coefficient,and provides an efficient state of charge prediction method adaptive to complex conditions.
文摘Five phospholipids in human placenta were determined by phosphorus 31 nuclear magnetic resonance(^(31)P NMR)spectroscopy and thin-layer chromatography(TLC) scanning combined with the corrective method of absorbance proportional coefficient. The NMR spectrometer used this investigation was a Bruker AM-500 spectrometer operating at 202.4 MHz for ^(31)P chemical shifts are relative to 85% phosphoric acid. TIC was carried out by silica gel H plate developed in chloroform-methanol-glacial acetic acid-ethanol-water(25:4:6:2:0.5),with Vaskovsky reagent as colour -developing agent of phospholipids.
基金Project supported by the National Natural Science Foundation of China (Grant Nos.81101070 and 81101175)
文摘The accuracy of attenuation correction in positron emission tomography scanners depends mainly on deriving the reliable 511-keV linear attenuation coefficient distribution in the scanned objects. In the PET/CT system, the linear attenu- ation distribution is usually obtained from the intensities of the CT image. However, the intensities of the CT image relate to the attenuation of photons in an energy range of 40 keV-140 keV. Before implementing PET attenuation correction, the intensities of CT images must be transformed into the PET 511-keV linear attenuation coefficients. However, the CT scan parameters can affect the effective energy of CT X-ray photons and thus affect the intensities of the CT image. Therefore, for PET/CT attenuation correction, it is crucial to determine the conversion curve with a given set of CT scan parameters and convert the CT image into a PET linear attenuation coefficient distribution. A generalized method is proposed for con- verting a CT image into a PET linear attenuation coefficient distribution. Instead of some parameter-dependent phantom calibration experiments, the conversion curve is calculated directly by employing the consistency conditions to yield the most consistent attenuation map with the measured PET data. The method is evaluated with phantom experiments and small animal experiments. In phantom studies, the estimated conversion curve fits the true attenuation coefficients accurately, and accurate PET attenuation maps are obtained by the estimated conversion curves and provide nearly the same correction results as the true attenuation map. In small animal studies, a more complicated attenuation distribution of the mouse is obtained successfully to remove the attenuation artifact and improve the PET image contrast efficiently.
文摘The heat transfer coefficient in a multidimensional heat conduction problem is obtained from the solution of the inverse heat conduction problem based on the thermographic temperature measurement. The modified one-dimensional correction method (MODCM), along with the finite volume method, is employed for both two- and three-dimensional inverse problems. A series of numerical experiments are conducted in order to verify the effectiveness of the method. In addition, the effect of the temperature measurement error, the ending criterion of the iteration, etc. on the result of the inverse problem is investigated. It is proved that the method is a simple, stable and accurate one that can solve successfully the inverse heat conduction problem.
基金Supported by the National Key Research and Development Program of China(Nos.2016YFB0501502,2016YFC1400903,2016YFB0500304)the National Natural Science Foundation of China(Nos.91638201,41276184,41325004,41471308,41571361)+1 种基金the High Resolution Earth Observation Systems of National Science and Technology Major Projects(No.41-Y20A31-9003-15/17)the Director Foundation of Institute of Remote Sensing and Digital Earth,Chinese Academy of Sciences(No.Y6SJ2100CX)
文摘The absorption coefficient of water is an important bio-optical parameter for water optics and water color remote sensing. However, scattering correction is essential to obtain accurate absorption coefficient values in situ using the nine-wavelength absorption and attenuation meter AC9. Establishing the correction always fails in Case 2 water when the correction assumes zero absorption in the near-infrared(NIR) region and underestimates the absorption coefficient in the red region, which affect processes such as semi-analytical remote sensing inversion. In this study, the scattering contribution was evaluated by an exponential fitting approach using AC9 measurements at seven wavelengths(412, 440, 488, 510, 532, 555, and 715 nm) and by applying scattering correction. The correction was applied to representative in situ data of moderately turbid coastal water, highly turbid coastal water, eutrophic inland water, and turbid inland water. The results suggest that the absorption levels in the red and NIR regions are significantly higher than those obtained using standard scattering error correction procedures. Knowledge of the deviation between this method and the commonly used scattering correction methods will facilitate the evaluation of the effect on satellite remote sensing of water constituents and general optical research using different scatteringcorrection methods.