期刊文献+
共找到62篇文章
< 1 2 4 >
每页显示 20 50 100
Optimization Study of Active-Passive Heating System Parameters in Village Houses in the Southern Xinjiang Province
1
作者 Xiaodan Wu Jie Li +1 位作者 Yongbin Cai Sihui Huang 《Energy Engineering》 EI 2024年第7期1963-1990,共28页
Aiming at the problems of large energy consumption and serious pollution of winter heating existing in the rural buildings in Southern Xinjiang,a combined active-passive heating system was proposed,and the simulation ... Aiming at the problems of large energy consumption and serious pollution of winter heating existing in the rural buildings in Southern Xinjiang,a combined active-passive heating system was proposed,and the simulation software was used to optimize the parameters of the system,according to the parameters obtained from the optimization,a test platform was built and winter heating test was carried out.The simulation results showed that the thickness of the air layer of 75 mm,the total area of the vent holes of 0.24 m^(2),and the thickness of the insulation layer of 120 mm were the optimal construction for the passive part;solar collector area of 28 m^(2),hot water storage tank volume of 1.4 m^(3),mass flow rate of 800 kg/h on the collector side,mass flow rate of 400 kg/h on the heat exchanger side,and output power of auxiliary heat source of 5∼9 kWwere the optimal constructions for active heating system.Test results showed that during the heating period,the system could provide sufficient heat to the room under different heating modes,and the indoor temperature reached over 18°C,which met the heating demand.The economic and environmental benefits of the system were analyzed,and the economic benefits of the systemwere better than coal-fired heating,and the CO_(2) emissionswere reduced by 3,292.25 kg compared with coalfiredheating.The results of the study showed that the combinedactive-passiveheating systemcouldeffectively solve the heating problems existing in rural buildings in Southern Xinjiang,and it also laid the theoretical foundation for the popularization of the combined heating systems. 展开更多
关键词 Trombe wall biomass boilers active-passive combined heating systems parameter optimization villages and towns
下载PDF
Robust optimal dispatch strategy of integrated energy system considering CHP-P2G-CCS
2
作者 Bin Zhang Yihui Xia Xiaotao Peng 《Global Energy Interconnection》 EI CSCD 2024年第1期14-24,共11页
Integrated energy systems(IESs)can improve energy efficiency and reduce carbon emissions,essential for achieving peak carbon emissions and carbon neutrality.This study investigated the characteristics of the CHP model... Integrated energy systems(IESs)can improve energy efficiency and reduce carbon emissions,essential for achieving peak carbon emissions and carbon neutrality.This study investigated the characteristics of the CHP model considering P2G and carbon capture systems,and a two-stage robust optimization model of the electricity-heat-gascold integrated energy system was developed.First,a CHP model considering the P2G and carbon capture system was established,and the electric-thermal coupling characteristics and P2G capacity constraints of the model were derived,which proved that the model could weaken the electric-thermal coupling characteristics,increase the electric power regulation range,and reduce carbon emissions.Subsequently,a two-stage robust optimal scheduling model of an IES was constructed,in which the objective function in the day-ahead scheduling stage was to minimize the start-up and shutdown costs.The objective function in the real-time scheduling stage was to minimize the equipment operating costs,carbon emission costs,wind curtailment,and solar curtailment costs,considering multiple uncertainties.Finally,after the objective function is linearized with a ψ-piecewise method,the model is solved based on the C&CG algorithm.Simulation results show that the proposed model can effectively absorb renewable energy and reduce the total cost of the system. 展开更多
关键词 Combined heat and power Power-to-gas Carbon capture system Integrated energy system Robust optimization
下载PDF
Diesel generator exhaust heat recovery fully-coupled with intake air heating for off-grid mining operations:An experimental,numerical,and analytical evaluation
3
作者 Durjoy Baidya Marco Antonio Rodrigues de Brito +1 位作者 Agus PSasmito Seyed Ali Ghoreishi-Madiseh 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2022年第1期155-169,共15页
The customarily discarded exhaust from the fossil fuel-based power plants of the off-grid mines holds the thermal potential to fulfill the heating requirement of the underground operation.This present research fills i... The customarily discarded exhaust from the fossil fuel-based power plants of the off-grid mines holds the thermal potential to fulfill the heating requirement of the underground operation.This present research fills in an important research gap by investigating the coupling effect between a diesel exhaust heat recovery and an intake air heating system employed in a remote mine.An integrative approach comprising analytical,numerical,and experimental assessment has been adapted.The novel analytical model developed here establishes the reliability of the proposed mine heating system by providing comparative analysis between a coupled and a decoupled system.The effect of working fluid variation has been examined by the numerical analysis and the possible improvement has been identified.Experimental investigations present a demonstration of the successful lab-scale implementation of the concept and validate the numerical and analytical models developed.Successful deployment of the fully coupled mine heating system proposed here will assist the mining industry on its journey towards energy-efficient,and sustainable mining practices through nearly 70%reduction in fossil fuel consumption for heating intentions. 展开更多
关键词 Remote mines Waste heat utilization Diesel exhaust Combined heat and power generation Clean energy in mining Coupled heating system
下载PDF
Thermo-economic Investigation of an Enhanced Geothermal System Organic Rankine Cycle and Combined Heating and Power System
4
作者 WANG Lingbao BU Xianbiao LI Huashan 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2021年第6期1958-1966,共9页
As a potentially viable renewable energy, Enhanced Geothermal Systems(EGSs) extract heat from hot dry rock(HDR) reservoirs to produce electricity and heat, which promotes the progress towards carbon peaking and carbon... As a potentially viable renewable energy, Enhanced Geothermal Systems(EGSs) extract heat from hot dry rock(HDR) reservoirs to produce electricity and heat, which promotes the progress towards carbon peaking and carbon neutralization. The main challenge for EGSs is to reduce the investment cost. In the present study, thermo-economic investigations of EGS projects are conducted. The effects of geofluid mass flow rate, wellhead temperature and loss rate on the thermo-economic performance of the EGS organic Rankine cycle(ORC) are studied. A performance comparison between EGS-ORC and the EGS combined heating and power system(CHP) is presented. Considering the CO_(2)emission reduction benefits, the influence of carbon emission trading price on the levelized cost of energy(LCOE) is also presented. It is indicated that the geofluid mass flow rate is a critical parameter in dictating the success of a project. Under the assumed typical working conditions, the LCOE of EGS-ORC and EGS-CHP systems are 24.72 and 16.1 cents/k Wh, respectively. Compared with the EGS-ORC system, the LCOE of the EGS-CHP system is reduced by 35%. EGS-CHP systems have the potential to be economically viable in the future. With carbon emission trading prices of 12.76 USD/ton, the LCOE can be reduced by approximately 8.5%. 展开更多
关键词 enhanced geothermal system organic Rankine cycle combined heating and power system thermo-economic investigation carbon emission reduction
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
5
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the po... The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2) and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling) demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamilv residential buildings. 展开更多
关键词 Combined cooling heating and power (CCHP) Air-cooled microturbines Distributed energy generation Water for energy production Net metering
下载PDF
Optimal Scheduling Method of Cogeneration System with Heat Storage Device Based on Memetic Algorithm 被引量:1
6
作者 Haibo Li YibaoWang +2 位作者 Xinfu Pang Wei Liu Xu Zhang 《Energy Engineering》 EI 2023年第2期317-343,共27页
Electric-heat coupling characteristics of a cogeneration system and the operating mode of fixing electricity with heat are the main reasons for wind abandonment during the heating season in the Three North area.To imp... Electric-heat coupling characteristics of a cogeneration system and the operating mode of fixing electricity with heat are the main reasons for wind abandonment during the heating season in the Three North area.To improve the wind-power absorption capacity and operating economy of the system,the structure of the system is improved by adding a heat storage device and an electric boiler.First,aiming at the minimum operating cost of the system,the optimal scheduling model of the cogeneration system,including a heat storage device and electric boiler,is constructed.Second,according to the characteristics of the problem,a cultural gene algorithm program is compiled to simulate the calculation example.Finally,through the system improvement,the comparison between the conditions before and after and the simulation solutions of similar algorithms prove the effectiveness of the proposed scheme.The simulation results show that adding the heat storage device and electric boiler to the scheduling optimization process not only improves the wind power consumption capacity of the cogeneration system but also reduces the operating cost of the system by significantly reducing the coal consumption of the unit and improving the economy of the system operation.The cultural gene algorithm framework has both the global evolution process of the population and the local search for the characteristics of the problem,which has a better optimization effect on the solution. 展开更多
关键词 Combined heat and power generation heat storage device memetic algorithm simulated annealing wind abandonment
下载PDF
Assessment of the thermal effect of large industrial buildings on permafrost foundation soils in Yakutsk
7
作者 Rudolf V.Zhang Stanislav I.Zabolotnik Pavel S.Zabolotnik 《Research in Cold and Arid Regions》 CSCD 2023年第6期262-267,共6页
The results of monitoring studies of the ground thermal state beneath the Yakutsk Combined Heat and Power Plant buildings are presented in order to determine their structural stability and the possibility of further t... The results of monitoring studies of the ground thermal state beneath the Yakutsk Combined Heat and Power Plant buildings are presented in order to determine their structural stability and the possibility of further troublefree operation of the entire complex of the structures.The main causes for the formation of water-bearing taliks under and adjacent to the buildings are presented,and the factors influencing the existing geocryological situation are discussed.The continuing stable state of the buildings demonstrates the possibility of using two construction principles on permafrost at one site,including preserving permafrost and accommodating permafrost thawing. 展开更多
关键词 Yakutsk Combined Heat and Power Plant PERMAFROST Talik Ground temperature
下载PDF
Simulation and performance analysis of organic Rankine cycle combined heat and power system
8
作者 刘玉兰 曹政 +1 位作者 陈九法 熊健 《Journal of Southeast University(English Edition)》 EI CAS 2015年第4期489-495,共7页
To improve the overall thermal efficiency of the organic Rankine cycle( ORC), a simulation study was carried out for a combined heat and power( CHP) system, using the Redlich-Kuang-Soave( RKS) equation of state.... To improve the overall thermal efficiency of the organic Rankine cycle( ORC), a simulation study was carried out for a combined heat and power( CHP) system, using the Redlich-Kuang-Soave( RKS) equation of state. In the system,R245 fa was selected as the working fluid. A scroll expander was modeled with empirical isentropic expansion efficiency.Plate heat exchangers were selected as the evaporator and the condenser, and detailed heat transfer models were programmed for both one-phase and two-phase regions. Simulations were carried out at seven different heat source temperatures( 80,90, 100, 110, 120, 130, 140 ℃) in combination with eight different heat sink temperatures( 20, 25, 30, 35, 40, 45, 50,55 ℃). Results showthat in the ORC without an internal heat exchanger( IHE), the optimum cycle efficiencies are in the range of 7. 0% to 7. 3% when the temperature differences between the heat source and heat sink are in the range of 70 to90 ℃. Simulations on CHP reveal that domestic hot water can be produced when the heat sink inlet temperature is higher than40 ℃, and the corresponding exergy efficiency and overall thermal efficiency are 29% to 56% and 87% to 90% higher than those in the non-CHP ORC, respectively. It is found that the IHE has little effect on the improvement of work output and efficiencies for the CHP ORC. 展开更多
关键词 organic Rankine cycle combined heat and power cycle efficiency exergy efficiency thermal efficiency
下载PDF
Heat and hazardous contaminant transports in ventilated high-rise industrial halls 被引量:4
9
作者 王沨枫 刘志强 +3 位作者 Christoph van Treeck 王汉青 唐文武 寇广孝 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第6期2106-2118,共13页
Performances and efficiencies of displacement ventilation(DV) and partial ventilation(PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numer... Performances and efficiencies of displacement ventilation(DV) and partial ventilation(PV) for industrial halls of different configurations as well as the heat and mass transports within the industrial halls were numerically investigated. Three levels of Rayleigh number(5.8×1010, 1.0×1012 and 2.1×1012) and two values of source contaminant flux(5 mg/s and 50 mg/s) were considered. The inlet Reynolds numbers were 2×104, 5×104, 1.5×105 and 4.5×105 for DV and 5×105, 1×106, 2×106 and 4×106 for PV, respectively. From the results, it is concluded that the above parameters have very complex impacts on the conjugated heat and mass transports. From points of view of acceptable indoor air quality and ventilation efficiency, PV at Re=1×106 with side-located sources and 65% of the supply air extracted through floor level outlets is the best choice when Ra=5.8×1010. However, DVs at Re=5×104 and Re=1.5×105with center-located sources and floor-mounted air suppliers are the best choices for Ra=1.0×1012 and Ra=2.1×1012, respectively. When source contaminant flux reaches 50 mg/s, local extraction as a supplement of general ventilation is recommended. The results can be a first approximation to 3D numerical investigation and preliminary ventilation system design guidelines for high-rise industrial halls. 展开更多
关键词 large space general ventilation highly turbulent flows combined heat and mass transports
下载PDF
Optimization of combined endoreversible Carnot heat engines with different objectives 被引量:4
10
作者 程雪涛 梁新刚 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期239-244,共6页
Taking the output power, thermal efficiency, and thermo-economic performance as the optimization objectives, we optimize the operation parameters of a thermodynamic system with combined endoreversible Carnot heat engi... Taking the output power, thermal efficiency, and thermo-economic performance as the optimization objectives, we optimize the operation parameters of a thermodynamic system with combined endoreversible Carnot heat engines in this paper. The applicabilities of the entropy generation minimization and entransy theory to the optimizations are discussed. For the discussed cases, only the entransy loss coefficient is always agreeable to the optimization of thermal efficiency. The applicabilities of the other discussed concepts to the optimizations are conditional. Different concepts and principles are needed for different optimization objectives, and the optimization principles have their application preconditions. When the preconditions are not satisfied, the principles may be not applicable. 展开更多
关键词 combined endoreversible Carnot heat engines entransy theory entropy generation minimization finite time thermodynamics
下载PDF
WHR (Waste Heat Technology) Method in Tri-generation Model 被引量:2
11
作者 Imrich Discantiny 《Journal of Geological Resource and Engineering》 2015年第1期37-41,共5页
This paper is focused on description of cool production in using WHR (Waste Heat Technology) Technology-a new method of centralized production of heat by using the waste heat from generated exhaust gas, which has be... This paper is focused on description of cool production in using WHR (Waste Heat Technology) Technology-a new method of centralized production of heat by using the waste heat from generated exhaust gas, which has been in 2009 developed and operated by companies HELORO s.r.o, and COMTHERM s.r.o. 展开更多
关键词 NG (natural gas) GB (gas boiler) CHP (combined heat power) CHPC (combined heat power cool) CGU(co-generation unit) ABSU (absorption unit) TC (thermal condenser) HE1 HE2 (heat exchanger).
下载PDF
Combining the complex variable reproducing kernel particle method and the finite element method for solving transient heat conduction problems 被引量:2
12
作者 陈丽 马和平 程玉民 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第5期67-74,共8页
In this paper, the complex variable reproducing kernel particle (CVRKP) method and the finite element (FE) method are combined as the CVRKP-FE method to solve transient heat conduction problems. The CVRKP-FE metho... In this paper, the complex variable reproducing kernel particle (CVRKP) method and the finite element (FE) method are combined as the CVRKP-FE method to solve transient heat conduction problems. The CVRKP-FE method not only conveniently imposes the essential boundary conditions, but also exploits the advantages of the individual methods while avoiding their disadvantages, then the computational efficiency is higher. A hybrid approximation function is applied to combine the CVRKP method with the FE method, and the traditional difference method for two-point boundary value problems is selected as the time discretization scheme. The corresponding formulations of the CVRKP-FE method are presented in detail. Several selected numerical examples of the transient heat conduction problems are presented to illustrate the performance of the CVRKP-FE method. 展开更多
关键词 complex variable reproducing kernel particle method finite element method combined method transient heat conduction
下载PDF
Solution of Combined Heat and Power Economic Dispatch Problem Using Direct Optimization Algorithm 被引量:1
13
作者 Dedacus N. Ohaegbuchi Olaniyi S. Maliki +1 位作者 Chinedu P. A. Okwaraoka Hillary Erondu Okwudiri 《Energy and Power Engineering》 CAS 2022年第12期737-746,共10页
This paper presents the solution to the combined heat and power economic dispatch problem using a direct solution algorithm for constrained optimization problems. With the potential of Combined Heat and Power (CHP) pr... This paper presents the solution to the combined heat and power economic dispatch problem using a direct solution algorithm for constrained optimization problems. With the potential of Combined Heat and Power (CHP) production to increase the efficiency of power and heat generation simultaneously having been researched and established, the increasing penetration of CHP systems, and determination of economic dispatch of power and heat assumes higher relevance. The Combined Heat and Power Economic Dispatch (CHPED) problem is a demanding optimization problem as both constraints and objective functions can be non-linear and non-convex. This paper presents an explicit formula developed for computing the system-wide incremental costs corresponding with optimal dispatch. The circumvention of the use of iterative search schemes for this crucial step is the innovation inherent in the proposed dispatch procedure. The feasible operating region of the CHP unit three is taken into account in the proposed CHPED problem model, whereas the optimal dispatch of power/heat outputs of CHP unit is determined using the direct Lagrange multiplier solution algorithm. The proposed algorithm is applied to a test system with four units and results are provided. 展开更多
关键词 Economic Dispatch Lagrange Multiplier Algorithm Combined Heat and Power Constraints and Objective Functions Optimal Dispatch
下载PDF
The ecosystem of Lake Kenon:past and present(Transbaikal Territory,Russia)
14
作者 Alexey P.KUKLIN Gazhit Ts.TSYBEKMITOVA +2 位作者 Evgenia P.GORLACHEVA Balzhit B.BAZAROVA Alexey V.AFONIN 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2016年第3期507-516,共10页
Present-day conditions of the Lake Kenon ecosystem are determined by a combination of natural and anthropogenic factors. We have estimated the effects of a complex of factors on the condition of the abiotic environmen... Present-day conditions of the Lake Kenon ecosystem are determined by a combination of natural and anthropogenic factors. We have estimated the effects of a complex of factors on the condition of the abiotic environment and on specific biological components in the lake ecosystem. Change in biogenic load has caused an increase in the role of phytoplankton in the general balance of organic matter during the high-water period. Charophytes are the main dominants of bottom vegetation. Anthropogenic load has caused a decrease in both fish species and fish capacity. The lake application as a water reservoir-cooler has influenced the average annual water mineralization (from 420 mg/L to 530.0 mg/L with a maximum 654 mg/L in 1993) and fluctuations in its hydrochemical composition. The present composition of the lake is sulfate-hydrocarbonate-chloride calcium-sodic-magnesium in character. S(Y44 content is twice as much as the maximum permissible concentration in fishery waters. Water drainage from an ash disposal area to the lake has caused an increase in chemical-element concentrations including the heavy metals. Hg concentration in Perca fluviatilis muscles is 0.5 9g/g dry wt. Thus, understanding directions in the ecosystem of the water reservoir-cooler under changing hydrological conditions will let us forecast the consequences of new combined heat and power plant operation. 展开更多
关键词 water reservoir-cooler of combined heat and power plant (CHP) HYDROCHEMISTRY ICHTHYOFAUNA BIODIVERSITY the chemical elements
下载PDF
Prediction of the Behavior of a Power System Using Root Cause Failure Analysis
15
作者 Seyed Mohammad Seyed Hosseini Kamran Shahanaghi Safar Shasfand 《Fluid Dynamics & Materials Processing》 EI 2022年第3期815-833,共19页
The thermo-economic performance of a gas turbine is simulated using a fish bone technique to characterize the major equipment failure causes.Moreover a fault tree analysis and a Pareto technique are implemented to ide... The thermo-economic performance of a gas turbine is simulated using a fish bone technique to characterize the major equipment failure causes.Moreover a fault tree analysis and a Pareto technique are implemented to identify the related failure modes,and the percentage and frequency of failures,respectively.A pump 101 and drier 301 belonging to the Tabriz Petrochemical Company are considered for such analysis,which is complemented with a regression method to determine a behavioral model of this equipment over a twenty-year period.Research findings indicate that 81%of major failure factors in production equipment are related to the executive procedures(24%),human error(22%),poor quality of materials and parts(20%),and lack of personnel training(15%). 展开更多
关键词 Combined heat and power root analysis thermoeconomic performance fault tree PARETO behavioral model
下载PDF
Operation Strategy Analysis and Configuration Optimization of Solar CCHP System
16
作者 Duojin Fan Chengji Shi +1 位作者 Kai Sun Xiaojuan Lu 《Energy Engineering》 EI 2021年第4期1197-1221,共25页
This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem... This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem in the PTST unit provides both thermal energy and electrical energy.Based on the life cycle method,the configuration optimization under eight operation strategies is studied with the economy,energy,and environment indicators.The eight operation strategies include FEL,FEL-EC,FEL-TES,FEL-TES&EC,FTL,FTL-EC,FTL-TES,and FTL-TES&EC.The feasibility of each strategy is verified by taking a residential building cluster as an example.The indicators under the optimal configuration of each strategy are compared with that of the separate production(SP)system.The results showed that the PTST-CCHP system improves the environment and energy performance by changing the ratio of thermal energy and electric energy.The environment and energy indicators of FEL-TES&EC are superior to those of FTL-TES&EC in summer,and the results are just the opposite in winter.The initial annual investment of the PTST-CCHP system is higher than that of the SP system,but its economic performance is better than that of the SP system with the increase of life-cycle. 展开更多
关键词 Combined cooling heating and power(CCHP)system trough solar thermal power generation operation strategy optimization configuration hill-climbing algorithm(HCA)
下载PDF
Temperature distribution of fluids in a two-section two-phase closed thermosyphon wellbore
17
作者 Zhang Yufeng Zhao Lun +5 位作者 Fan Zifei Wu Xiaodong Fu Libing Xu Bifeng Kong Fanshun Jiang Shengdong 《Petroleum Science》 SCIE CAS CSCD 2014年第2期287-292,共6页
Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in... Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in wellbores, increase the temperature of fluid in wellheads and even more effectively reduce the failure rate of conventional TPCT wellbores. Heat transfer performance of two-section TPCT wellbores is affected by working medium, combination mode and oil flow rate. Different working media are introduced into the upper and lower TPCTs, which may achieve a better match between the working medium and the temperature field in the wellbores. Interdependence exists between the combination mode and the flow rate of the oil, which affects the heat transfer performance of a two-section TPCT wellbore. The experimental results show that a two-section TPCT wellbore, with equal upper and lower TPCTs respectively filled with Freon and methanol, has the best heat transfer performance when the oil flow rate is 200 L/h. 展开更多
关键词 Two-section two-phase closed thermosyphon temperature distribution combination mode heat transfer performance
下载PDF
Dynamic Simulation and Performance Analysis on Multi-Energy Coupled CCHP System
18
作者 Xueqin Tian Jinfei Sun +5 位作者 Tong Xu Mengran Cui Xinlei Wang Jianxiang Guo De-gejirifu Na Wang 《Energy Engineering》 EI 2022年第2期723-737,共15页
Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matchi... Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matching between supply and demand loads due to the unbalance features of the user’s cooling and heating loads.On the basis of user convenience and wide applicability of clean air energy,this paper tries to put forward a coupled CCHP system with combustion gas turbine and ASHP ordered power by heat,analyze trends of such parameters as gas consumption and power consumption of heat pump in line with adjustment of heating load proportion of combustion gas turbine,and optimize the system ratio in the method of annual costs and energy environmental benefit assessment.Based on the analysis of the hourly simulation and matching characteristics of the cold and hot load of the 100 thousand square meter building,it is found that the annual cost of the air source heat pump is low,but the energy and environmental benefits are poor.It will lead to 6.35%shortage of cooling load in summer.Combined with the evaluation method of primary energy consumption and zero carbon dioxide emission,the coupling system of CHHP and air source heat pump with 41%gas turbine load ratio is the best configuration.This system structure and optimization method can provide some reference for the development of CCHP coupling system. 展开更多
关键词 CCHP(Combined Cooling heating and Power System) ASHP(Air Source Heat Pump) annual costs absorption cooling transient simulation
下载PDF
Schedule for Reducing the Use of Peat and the Possibilities of Replacing It with Forest Chips in Energy Production in Finland
19
作者 Tapio Ranta Antti Karhunen Mika Laihanen 《Journal of Sustainable Bioenergy Systems》 CAS 2022年第4期99-115,共17页
Between 2018 and 2020, an average of 15 TWh of energy peat was consumed in Finland. Energy peat is used in 260 boilers in Finland, which produce district heat and heat and steam for industry, as well as electricity as... Between 2018 and 2020, an average of 15 TWh of energy peat was consumed in Finland. Energy peat is used in 260 boilers in Finland, which produce district heat and heat and steam for industry, as well as electricity as cogeneration (CHP) in connection with district heating and industrial heat production. Peat accounts for 3% - 5% of the energy sources used in Finland, but its importance has been greater in terms of security of supply. With current use in accordance with the 2018-2020 average, the emissions from peat are almost 6 Mt CO<sub>2</sub> per year in Finland, which is 15% of emissions from the energy sector. In this study, the technical limitations related to peat burning, economic limitations related to the availability of biomass, and socio-economic limitations related to the regional economy are reviewed. By 2040, the technical minimum use of peat will fall to 2 TWh. The techno-economical potential may be even lower, but due to socio-economic objectives, peat production will not be completely ceased. The reduction in the minimum share assumes that old peat boilers are replaced with new biomass boilers or are alternatively replaced by other forms of heat production. Based on the biomass reserves, the current use of peat can be completely replaced by forest chips, but regional challenges may occur along the coast and in southern Finland. It is unlikely that the current demand for all peat will be fully replaced by biomass when part of CHP production is replaced by heat production alone and combustion with waste heat sources. 展开更多
关键词 Biomass Supply Market ECONOMICS Heat Combined Heat and Power Generation (CHP)
下载PDF
Electricity Pricing for Natural Gas CHP Projects The Higher, the Better?
20
作者 Chen Guowei Guo Xicheng He Chun 《Electricity》 2011年第3期23-26,共4页
Regarding the state's policy that gives a higher on-grid electricity price to natural gas CHP (combined heat and power) projects, this paper studies the effect of it on the operation of those projects by theoretic... Regarding the state's policy that gives a higher on-grid electricity price to natural gas CHP (combined heat and power) projects, this paper studies the effect of it on the operation of those projects by theoretical analysis and a case study. It concludes that on-grid electricity price on the high side, compared to heat price, will lead power plants to produce more electricity but less heat, thus causing decrease of the plants' thermal eff iciency and harm to energy saving of the whole society. 展开更多
关键词 combined heat and power (CHP) natural gas power generation on-grid electricity price energy saving
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部