Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in...Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in wellbores, increase the temperature of fluid in wellheads and even more effectively reduce the failure rate of conventional TPCT wellbores. Heat transfer performance of two-section TPCT wellbores is affected by working medium, combination mode and oil flow rate. Different working media are introduced into the upper and lower TPCTs, which may achieve a better match between the working medium and the temperature field in the wellbores. Interdependence exists between the combination mode and the flow rate of the oil, which affects the heat transfer performance of a two-section TPCT wellbore. The experimental results show that a two-section TPCT wellbore, with equal upper and lower TPCTs respectively filled with Freon and methanol, has the best heat transfer performance when the oil flow rate is 200 L/h.展开更多
This paper deals with a numerical analysis of the evaporation of a thin binary liquid film by forced convection inside a channel constituted by two plates.The first plate is externally insulated and wetted by a thin w...This paper deals with a numerical analysis of the evaporation of a thin binary liquid film by forced convection inside a channel constituted by two plates.The first plate is externally insulated and wetted by a thin water ethylene glycol film while the second is dry and isothermal.The first part is concerned with the effects of inlet ambiance conditions and the liquid concentration of ethylene glycol on the distribution of the velocity,temperature,concentrations profiles and the axial variation of the evaporation rate.The second part is focused on the inversion temperature point of the evaporation of binary liquid film.Results show that the inversion temperature phenomenon for the evaporation of binary liquid mixture is observed for high liquid concentration of ethylene glycol.The present results show that in the inlet temperature range considered here,the inversion temperature does not exit for the evaporation of pure ethylene glycol.展开更多
基金the financial support from the National Natural Science Foundation of China (No. 50674096)PetroChina Scientific & Technological Risk Innovation Project (No. 060511-2-1)
文摘Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in wellbores, increase the temperature of fluid in wellheads and even more effectively reduce the failure rate of conventional TPCT wellbores. Heat transfer performance of two-section TPCT wellbores is affected by working medium, combination mode and oil flow rate. Different working media are introduced into the upper and lower TPCTs, which may achieve a better match between the working medium and the temperature field in the wellbores. Interdependence exists between the combination mode and the flow rate of the oil, which affects the heat transfer performance of a two-section TPCT wellbore. The experimental results show that a two-section TPCT wellbore, with equal upper and lower TPCTs respectively filled with Freon and methanol, has the best heat transfer performance when the oil flow rate is 200 L/h.
文摘This paper deals with a numerical analysis of the evaporation of a thin binary liquid film by forced convection inside a channel constituted by two plates.The first plate is externally insulated and wetted by a thin water ethylene glycol film while the second is dry and isothermal.The first part is concerned with the effects of inlet ambiance conditions and the liquid concentration of ethylene glycol on the distribution of the velocity,temperature,concentrations profiles and the axial variation of the evaporation rate.The second part is focused on the inversion temperature point of the evaporation of binary liquid film.Results show that the inversion temperature phenomenon for the evaporation of binary liquid mixture is observed for high liquid concentration of ethylene glycol.The present results show that in the inlet temperature range considered here,the inversion temperature does not exit for the evaporation of pure ethylene glycol.