期刊文献+
共找到166篇文章
< 1 2 9 >
每页显示 20 50 100
Multi-Level Approach of the Ecotoxicological Impact of a Combined Sewer Overflow on a Peri-Urban Stream
1
作者 Céline Becouze-Lareure Christine Bazin +2 位作者 Philippe Namour Pascal Breil Yves Perrodin 《Journal of Water Resource and Protection》 2012年第11期984-992,共9页
In periurban zones, urban wet weather discharges have been recognized as the most significant vector of pollution in aquatic environments. The discharge of this water without treatment into the aquatic environment cou... In periurban zones, urban wet weather discharges have been recognized as the most significant vector of pollution in aquatic environments. The discharge of this water without treatment into the aquatic environment could present an ecotoxicological risk for biocenosis. The aim of the INVASION project is to assess the potential ecotoxicological impact of a combined sewer overflow (CSO) on a peri-urban stream. A comparative study between upstream and downstream areas of the CSO allowed observing significant effects of this overflow on the river. We studied three layers of stream: surface water, benthic layer and hyporheic layer. To characterize the potential ecotoxicological risk of water and sediments, we used a battery of 4 bioassays: Daphnia magna, Vibrio fischeri, Brachionus calyciflorus and Heterocypris incongruens. In parallel, we measured the physico-chemical parameters: ammonium (NH4+), chromium (Cr), copper (Cu) and lead (Pb). An ecological risk is greatest for the hyporheic zone in downstream river, particularly for the solid phase. These results corroborated with the physico-chemical data obtained. 展开更多
关键词 combined sewer overflow ECOTOXICITY Pollutants STORMWATER STREAM Urban Wet-Weather Flow
下载PDF
海绵城市背景下合流制改造及溢流污染控制路径研究 被引量:1
2
作者 唐磊 刘广奇 +2 位作者 程小文 芮文武 赵亚君 《给水排水》 CSCD 北大核心 2024年第4期54-61,共8页
我国合流制排水管渠数量多、建设情况复杂、运行问题突出,已成为当前制约城市水环境质量提升的关键,在系统化全域推进海绵城市建设的背景下,合流制系统改造及溢流污染控制成为许多城市的重点任务。根据多年城市建设统计年鉴数据对我国... 我国合流制排水管渠数量多、建设情况复杂、运行问题突出,已成为当前制约城市水环境质量提升的关键,在系统化全域推进海绵城市建设的背景下,合流制系统改造及溢流污染控制成为许多城市的重点任务。根据多年城市建设统计年鉴数据对我国城市合流制排水管渠数量、分布及逐年变化情况进行分析;梳理我国城市合流制管渠系统状况、存在问题及当前海绵城市建设、黑臭水体治理、内涝综合整治、污水提质增效工作对合流制系统的相关要求,在此基础上提出适用于我国城市合流制系统的界定与评价方法;结合当前各城市在推进相关工作过程中存在的问题,提出海绵城市建设背景下合流制系统改造及溢流污染控制路径,即因地制宜制定合流制改造及溢流污染控制系统化方案,并明确系统化方案编制流程及技术要点。 展开更多
关键词 海绵城市 黑臭水体 合流制排水系统 溢流污染控制 系统化方案
下载PDF
基于监测与模型的典型合流制排水系统溢流污染来源解析 被引量:1
3
作者 韩杰 于磊 +4 位作者 蔡辉艺 严玉林 鞠琴 崔朝阳 加吾拉江·左尔丁 《给水排水》 CSCD 北大核心 2024年第4期76-82,共7页
以北京中心城区某典型合流制分区为研究区,开展自“地表-管网-排口”的全过程监测,基于MIKE URBAN软件构建数值模型,构建一套结合监测与模型的溢流污染解析方法,量化分析不同降雨量级下溢流污染来源。结果表明:管道沉积物、地表径流和... 以北京中心城区某典型合流制分区为研究区,开展自“地表-管网-排口”的全过程监测,基于MIKE URBAN软件构建数值模型,构建一套结合监测与模型的溢流污染解析方法,量化分析不同降雨量级下溢流污染来源。结果表明:管道沉积物、地表径流和生活污水对COD的贡献率分别为43.4%~53.9%、27.4%~27.5%和18.6%~29.2%。中雨流量峰值晚于浓度峰值,大雨反之;两场降雨溢流水质浓度峰值差异小于流量峰值。随着降雨量级及强度增加,地表径流和管道沉积物的污染负荷增加,后者增加量更大。管道沉积物是合流制溢流污染的主要来源,应优先对其进行控制。 展开更多
关键词 合流制 溢流污染 MIKE URBAN 来源解析 管道沉积物
下载PDF
CSO调蓄强化处理设施出水水质标准研究
4
作者 王伟 张超 +6 位作者 吴雪薇 刘军 郭彪 王梓玮 张诗雄 邓德宇 阮哲予 《广东化工》 CAS 2023年第12期16-19,共4页
目前,合流制溢流污染制约着我国黑臭水体的整治与环境质量的改善。在高密度建成区中建立CSO调蓄及强化处理设施,可有效控制合流制溢流污染并减轻污水处理厂的压力。本文通过分析国内外污染物控制标准及实际工程案例,对CSO调蓄及强化处... 目前,合流制溢流污染制约着我国黑臭水体的整治与环境质量的改善。在高密度建成区中建立CSO调蓄及强化处理设施,可有效控制合流制溢流污染并减轻污水处理厂的压力。本文通过分析国内外污染物控制标准及实际工程案例,对CSO调蓄及强化处理设施出水水质标准进行了研究,认为COD、BOD_(5)、SS、TP可作为出水的主要水质指标,而出水限值的确定需综合考虑工艺处理手段及受纳水体环境容量。CSO调蓄及强化处理设施出水水质标准的研究可为各地相关标准的制定提供参考。 展开更多
关键词 合流制溢流 cso强化处理设施 出水水质
下载PDF
合流制溢流污染的影响及其控制技术发展
5
作者 李俊奇 李小静 +2 位作者 王文亮 王二松 蔡然 《给水排水》 CSCD 北大核心 2024年第4期46-53,共8页
合流制溢流即未经处理的雨污废水直接流入受纳水体,是造成受纳水体污染和城市内涝的主要来源。首先,对合流制溢流的污染特征及其影响因素进行了总结,简要梳理了源头控制、处理设施、调蓄设施、雨天合流雨污水处理最新技术及其控制效果,... 合流制溢流即未经处理的雨污废水直接流入受纳水体,是造成受纳水体污染和城市内涝的主要来源。首先,对合流制溢流的污染特征及其影响因素进行了总结,简要梳理了源头控制、处理设施、调蓄设施、雨天合流雨污水处理最新技术及其控制效果,以及合流制溢流控制实时控制、监测和预测的智能控制方法。合流制溢流灰色和绿色基础设施都是必要的,随着监测、降水预报、城市水文和水力模型及实时控制技术的成熟,合流制溢流系统向实时控制和模型优化预测策略发展。 展开更多
关键词 合流制溢流 实时控制 监测与预报
下载PDF
长江流域平原河网地区合流制排水系统溢流污染特征研究
6
作者 刘宇轩 安欣琪 +4 位作者 林炳权 赵晨 高雅弘 齐飞 孙德智 《给水排水》 CSCD 北大核心 2024年第4期62-69,共8页
在平原河网地区丹金溧漕河金坛段选取3个典型合流制溢流排口及管道检查井进行溢流污染监测,分析溢流水质水量变化。以合流制管道沉积物为试验材料进行冲刷模拟试验,探究沉积物冲刷规律。结果表明,累积降雨量≥2 mm就会产生溢流现象;溢... 在平原河网地区丹金溧漕河金坛段选取3个典型合流制溢流排口及管道检查井进行溢流污染监测,分析溢流水质水量变化。以合流制管道沉积物为试验材料进行冲刷模拟试验,探究沉积物冲刷规律。结果表明,累积降雨量≥2 mm就会产生溢流现象;溢流水量变化主要受降雨等级、降雨强度及居民用水量影响,且溢流量峰值较降雨强度峰值滞后;溢流污染物浓度与前期干旱天数、排口性质、降雨等级和降雨强度有直接联系,其变化基本均呈先上升后下降趋势,且无论哪种降雨等级溢流口在产生径流后约20~30 min后污染物浓度会较高。沉积物对溢流污染贡献占比较大,管道冲刷过程中沉积颗粒物呈阶段交替式运动,各污染指标在降雨形成径流一段时间后出现峰值。 展开更多
关键词 合流制排水系统 溢流污染特征 降雨等级 管道沉积物 管道冲刷
下载PDF
合流制溢流(CSO)污染削减率评估方法探讨 被引量:3
7
作者 仲崇军 李文涛 《城市道桥与防洪》 2015年第8期94-97,138,共5页
随着污水治理技术的进步,点源水污染在得到较好控制的同时,面源水污染的问题越来越突出,特别是合流制地区的雨季溢流污染问题,已成为进一步提升城市水环境质量的主要障碍。鉴于溢流污染治理工程的特殊性,科学合理地确定工程效果评价方... 随着污水治理技术的进步,点源水污染在得到较好控制的同时,面源水污染的问题越来越突出,特别是合流制地区的雨季溢流污染问题,已成为进一步提升城市水环境质量的主要障碍。鉴于溢流污染治理工程的特殊性,科学合理地确定工程效果评价方法至关重要。结合广州市的相关研究成果,介绍溢流污染治理工程最主要的评价指标——溢流污染削减率的评估方法和思路,为其他城市开展相关工作提供参考。 展开更多
关键词 合流制溢流 溢流污染削减率 典型年降雨 典型溢流污水水质
下载PDF
山地城市合流制溢流污染控制措施研究
8
作者 刘硕 王通 +3 位作者 范科文 程玉林 张占文 姚玉健 《给水排水》 CSCD 北大核心 2024年第4期70-75,共6页
聚焦山地城市合流制溢流污染问题,以实际工程为例,梳理山地城市排水特点,明确工作目标,详细分析问题与成因,全面对比完全雨污分流与截流调蓄方案,因地制宜采取简单高效的治理措施,形成合理的CSO控制技术路线。给出近远期结合的治理方案... 聚焦山地城市合流制溢流污染问题,以实际工程为例,梳理山地城市排水特点,明确工作目标,详细分析问题与成因,全面对比完全雨污分流与截流调蓄方案,因地制宜采取简单高效的治理措施,形成合理的CSO控制技术路线。给出近远期结合的治理方案,结合模型模拟验证方案的可行性,实现减少溢流频次和削减入河污染物的目的,最终达到控制目标。 展开更多
关键词 山地城市 合流制溢流 调蓄池 考核断面
下载PDF
膜曝气生物膜反应器处理合流制溢流污水的实验研究
9
作者 马竞 刘炎炎 +3 位作者 简向阳 刘龙志 米鑫豪 王凤娟 《水处理技术》 CAS CSCD 北大核心 2024年第4期39-42,48,共5页
以聚丙烯复合材料经熔融拉伸制成的帘式超薄微孔中空纤维膜为载体,构建膜曝气生物膜反应器装置处理合流制溢流污水,研究在不同水力停留时间、曝气压力、水流流速条件下,膜曝气生物膜反应器对水体中污染物COD、NH_(4)^(+)-N、TN的去除率... 以聚丙烯复合材料经熔融拉伸制成的帘式超薄微孔中空纤维膜为载体,构建膜曝气生物膜反应器装置处理合流制溢流污水,研究在不同水力停留时间、曝气压力、水流流速条件下,膜曝气生物膜反应器对水体中污染物COD、NH_(4)^(+)-N、TN的去除率。结果表明:膜曝气生物膜反应器对水体中各项污染物均有较好去除效果。水力停留时间为12 h时,COD、NH_(4)^(+)-N、TN去除效果较好,去除率分别为80.8%、82.4%、65.4%;水力停留时间为8 h时,TP去除效果达到34.2%,后期逐渐趋于平缓。溶解氧浓度随曝气压力增加而增加,曝气压力达到25 kPa之后COD、NH_(4)^(+)-N达到较佳的去除率,平均去除率分别为82.2%、84.1%;而TN去除的最佳曝气压力为15 kPa,去除率为70.0%。水流流速为0.03 m/s和0.05 m/s时,反应器整体运行效果较好,对COD、NH_(4)^(+)-N、TN的平均去除率分别为81.8%、83.5%、67.8%。 展开更多
关键词 膜曝气生物膜反应器 合流制溢流污水 曝气压力 氨氮 水力停留时间
下载PDF
老城区合流制溢流污染控制及优化调度研究
10
作者 彭丽红 《市政技术》 2024年第4期245-253,共9页
针对老城区截流式合流制溢流(CSOs)污染问题,以长沙市桂花祠泵站服务区域为例,基于实测降雨数据、水质水量监测和数值模拟手段,以年均溢流频次控制率为考核指标,进行排水系统改造和CSOs调蓄池优化设计。工程采用“高低区单独截污+截污干... 针对老城区截流式合流制溢流(CSOs)污染问题,以长沙市桂花祠泵站服务区域为例,基于实测降雨数据、水质水量监测和数值模拟手段,以年均溢流频次控制率为考核指标,进行排水系统改造和CSOs调蓄池优化设计。工程采用“高低区单独截污+截污干管2倍截流+末端CSOs调蓄池建设”组合工艺来达到年均溢流频次控制率不低于50%,结合降雨特性和Infoworks ICM模型模拟分析,确定截污系统截流倍数、CSOs调蓄池容积,并精准确定相关设计参数,为老城区合流制排水系统改造和优化运行以及溢流污染控制工程设计提供参考和借鉴。 展开更多
关键词 csoS 排水系统 溢流频次 调蓄 优化调度
下载PDF
小城镇排水系统现状与问题研究
11
作者 周城 《市政技术》 2024年第6期202-207,236,共7页
由于我国小城镇排水系统建设比较滞后,导致城镇水体污染问题日益突出,其排水系统亟待完善。如何有效控制城镇水污染,提高城镇人居环境质量,已成为小城镇建设和可持续发展的重要内容。通过对小城镇排水系统的现状进行剖析,找出其存在的... 由于我国小城镇排水系统建设比较滞后,导致城镇水体污染问题日益突出,其排水系统亟待完善。如何有效控制城镇水污染,提高城镇人居环境质量,已成为小城镇建设和可持续发展的重要内容。通过对小城镇排水系统的现状进行剖析,找出其存在的主要问题,并以此为基础,以切实提高污水收集率、保证污水管网建设效果为目标,分别从排水系统规划的制定、建筑排水立管的改造、市政雨污混接的改造、合流系统的改造、合流制溢流污染的控制、污水收集的新技术等多层面多角度提出了相应的解决办法和对策,以期为小城镇排水系统的建设和改造提供参考。 展开更多
关键词 小城镇 排水系统 雨污分流改造 合流制溢流控制
下载PDF
城市画像下大城市初雨污染治理策略分析
12
作者 孙晓峰 《市政技术》 2024年第10期194-199,241,共7页
初雨污染作为河道水质恶化的主要原因之一,是我国许多城市尤其是一些大城市水环境治理中亟待解决的重大难题。详细阐述了国外典型大城市东京、纽约、伦敦、巴黎、柏林和国内典型大城市北京、广州、深圳、上海初雨污染的现状和管控措施... 初雨污染作为河道水质恶化的主要原因之一,是我国许多城市尤其是一些大城市水环境治理中亟待解决的重大难题。详细阐述了国外典型大城市东京、纽约、伦敦、巴黎、柏林和国内典型大城市北京、广州、深圳、上海初雨污染的现状和管控措施。将调研城市的数据分为基本属性数据、措施偏好数据、服务偏好数据,并聚焦源头、过程、末端等重要环节,针对不同类型下大城市选择的初雨污染治理模式,开展了自然禀赋、降雨特征、面源污染特征、河道水环境等情况评估,形成城市的基础画像,在此基础上重点对比分析了典型大城市与初雨污染治理模式之间的相关性,以期为大城市初雨污染治理策略研究提供支撑。 展开更多
关键词 初雨污染 大城市 城市画像 合流制溢流污染
下载PDF
Quantitative analysis of impact of green stormwater infrastructures on combined sewer overflow control and urban flooding control 被引量:1
13
作者 Jinsong Tao Zijian Li +1 位作者 Xinlai Peng Gaoxiang Ying 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2017年第4期93-104,共12页
Stimulated by the recent USEPA's green stormwater infrastructure (GSI) guidance and policies, GS1 systems have been widely implemented in the municipal area to control the combined sewer overflows (CSOs), also kn... Stimulated by the recent USEPA's green stormwater infrastructure (GSI) guidance and policies, GS1 systems have been widely implemented in the municipal area to control the combined sewer overflows (CSOs), also known as low impact development (LID) approaches. To quantitatively evaluate the performance of GSI systems on CSO and urban flooding control, USEPA-Stormwater Management Model (SWMM) model was adopted in this study to simulate the behaviors of GSI systems in a well- developed urban drainage area, PSW45, under different circumstances. The impact of different percentages of stormwater runoff transported from impervious surfaces to the GSI systems on CSO and urban flooding control has also been investigated. Results show that with current buildup, GSI systems in PSW45 have the best performance for low intensity and short duration events on both volume and peak flow reductions, and have the worst pertbrmance tor high intensity and long durataon events. Since the low intensity and short duration events are dominant from a long-term perspective, utilizing GSI systems is considered as an effective measure of CSO control to meet the long-term controlstrategy for PSW45 watershed. However, GSI systems are not suitable for the flooding control purpose in PSW45 due to the high occurrence possibility of urban flooding during or after high intensity events where GSI systems have relatively poor performance no matter for a short or long duration event, 展开更多
关键词 Green stormwater infrastructure (GSI) combined sewer overflows (csos) Urban flooding Low impact development (LID) Stormwater Management Model (SWMM)
原文传递
武汉市东湖水环境提升工程CSO调蓄池规模模拟研究 被引量:2
14
作者 徐成剑 胡胜利 《水利水电快报》 2021年第12期124-129,共6页
合流制溢流(CSO)污染是大多数老城区面源污染的主要来源之一,也是城市黑臭水体形成的主要因素。CSO调蓄池是一项控制CSO污染的重要工程措施,设计时确定其规模至关重要。以武汉市东湖水环境提升工程CSO调蓄池为例,针对区域溢流污染,提出... 合流制溢流(CSO)污染是大多数老城区面源污染的主要来源之一,也是城市黑臭水体形成的主要因素。CSO调蓄池是一项控制CSO污染的重要工程措施,设计时确定其规模至关重要。以武汉市东湖水环境提升工程CSO调蓄池为例,针对区域溢流污染,提出了两种CSO调蓄池建设方案。以控制年溢流频次或溢流污染物削减效果为目标,结合研究区域的降雨特性、管网建设等实际情况,采用InfoWorks ICM模型模拟了两种CSO调蓄池建设方案的规模,并综合考虑施工难度、投资及污染物削减效果等对两种方案进行比选。结果表明:方案二(只建设8万m3调蓄池)较方案一(6万m3调蓄池+2万m3/d处理站)更优,方案二可控制区域年溢流8次以内,溢流污染物削减率达70.4%。 展开更多
关键词 合流制溢流污染 cso调蓄池 调蓄池规模 InfoWorks ICM 溢流频次
下载PDF
Global optimal control for regional sewer systems
15
作者 周永潮 张仪萍 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期143-148,共6页
In order to control combined system overflow (CSO) pollution of regional sewer systems in Shanghai,a global optimal control (GOC) is presented in this study.The GOC is based on the analysis of current situation and ca... In order to control combined system overflow (CSO) pollution of regional sewer systems in Shanghai,a global optimal control (GOC) is presented in this study.The GOC is based on the analysis of current situation and can maximize the utilization of the free storage of each sub systems and decrease the frequencies and durations of CSOs and flooding.A representative regional sewer system,which is located in the northwest of Shanghai and composed of sub systems of Zhenguang,Zhenru and Tongchuan,was taken as an example to demonstrate the efficiency of GOC with hydraulic model simulation test in the two representative scenarios (Scenario Ⅰ and Ⅱ).The results indicated that a great improvement in CSO emission is obtained by using the GOC in the two scenarios,and the CSO volume of three sub systems,Zhenru,Tongchuan and Zhenguang decreases to about 37.0%,38.3% and 35.7% in Scenario Ⅰ and 47.5%,51.8% and 63.5% in Scenario Ⅱ respectively. 展开更多
关键词 storm runoff combined sewer overflow OPTIMIZATION simulation models
下载PDF
老城区合流制排水系统CSO调蓄池容积计算方法——以西南地区某市中心城区CSO调蓄池容积计算为例
16
作者 向熙 陈家平 《科学技术创新》 2022年第20期5-8,共4页
许多城市在进行城市改造时受历史条件及客观因素的制约,老城区的排水系统无法彻底改造成分流制系统,合流制排水系统将长期存在。对不便于进行雨污分流改造区域的合流溢流口建设调蓄池,将初期污染物浓度高、超过水体自净能力的这部分合... 许多城市在进行城市改造时受历史条件及客观因素的制约,老城区的排水系统无法彻底改造成分流制系统,合流制排水系统将长期存在。对不便于进行雨污分流改造区域的合流溢流口建设调蓄池,将初期污染物浓度高、超过水体自净能力的这部分合流水量调蓄,在降雨过后,在一定时间段内输送至合流污水截流干管或附近污水厂,避免直排河道,可以有效削减水体污染,是解决老城区合流制溢流污染的有效途径。以西南地区某市中心城区一个主要溢流口服务区域为例,采用截留倍数计算法和溢流体积控制率法对调蓄池容积进行核算,同时以实测溢流数据进行复核,进而得到CSO调蓄池的推荐有效容积。 展开更多
关键词 合流制排水系统 cso调蓄池 容积 截留倍数计算法 溢流体积控制率法
下载PDF
国内外城镇排水系统出流污染的研究进展 被引量:2
17
作者 邓海亮 孟祥挺 祝成 《净水技术》 CAS 2023年第S02期1-6,64,共7页
城镇排水系统出流污染是城市水体污染负荷的重要来源,也是制约我国河湖水体水质长期未得到改善的主要原因之一。文章通过分析美国、德国、英国、日本国家在径流污染控制和合流制溢流污染(CSOs)控制的理念、实践,对比国内研究进展,总结... 城镇排水系统出流污染是城市水体污染负荷的重要来源,也是制约我国河湖水体水质长期未得到改善的主要原因之一。文章通过分析美国、德国、英国、日本国家在径流污染控制和合流制溢流污染(CSOs)控制的理念、实践,对比国内研究进展,总结出当前我国排水系统出流污染控制领域存在成因研究不足、控制技术体系构建系统性不足、技术规范指导有待完善等问题,以期为后续出流污染控制工作提供参考。 展开更多
关键词 城镇排水系统 径流污染 初期雨水污染 合流制溢流 绿色基础设施
下载PDF
从污水处理厂运行管理浅析滇池保护治理 被引量:2
18
作者 尚雄 李正远 +2 位作者 周宪林 周榆程 李丽娟 《广东化工》 CAS 2023年第12期167-169,共3页
以污水处理厂运行管理视角,从厂、网联合调度,污水处理厂提标改造尾水回补河道,快速净化设施(一级强化处理系统)优化运行降低雨污合流污水溢流污染以及提标尾水再生利用等方面介绍滇池保护治理相关措施。
关键词 滇池流域 污水处理 提标改造 合流制溢流污染 再生水回用
下载PDF
Probability mass first flush evaluation for combined sewer discharges 被引量:5
19
作者 Inhyeok Park Hongmyeong Kim +1 位作者 Soo-Kwon Chae Sungryong Ha 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第6期915-922,共8页
The Korea government has put in a lot of effort to construct sanitation facilities for controlling non-point source pollution. The first flush phenomenon is a prime example of such pollution. However, to date, several... The Korea government has put in a lot of effort to construct sanitation facilities for controlling non-point source pollution. The first flush phenomenon is a prime example of such pollution. However, to date, several serious problems have arisen in the operation and treatment effectiveness of these facilities due to unsuitable design flow volumes and pollution loads. It is difficult to assess the optimal flow volume and pollution mass when considering both monetary and temporal limitations. The objective of this article was to characterize the discharge of storm runoff pollution from urban catchments in Korea and to estimate the probability of mass first flush (MFFn) using the storm water management model and probability density functions. As a result of the review of gauged storms for the representative using probability density function with rainfall volumes during the last two years, all the gauged storms were found to be valid representative precipitation. Both the observed MFFn and probability MFFn in BE-1 denoted similarly large magnitudes of first flush with roughly 40% of the total pollution mass contained in the first 20% of the runoff. In the case of BE-2, however, there were significant difference between the observed MFFn and probability MFFn. 展开更多
关键词 first flush combined sewer overflows (csos) probability mass first flush storm water management model best management practices
原文传递
调蓄池控制合流制溢流污染的作用及设计要点分析
20
作者 邢睿磊 《四川环境》 2023年第6期239-245,共7页
合流制溢流污染作为导致水体黑臭的重要原因之一,结合我国具体国情,合流制溢流污染可采用修建“截污管线+合流制调蓄池”的方式进行控制。调蓄池在控制合流制溢流污染过程中应用广泛,通过结合南宁市那平江流域治理的工程实例,总结设计经... 合流制溢流污染作为导致水体黑臭的重要原因之一,结合我国具体国情,合流制溢流污染可采用修建“截污管线+合流制调蓄池”的方式进行控制。调蓄池在控制合流制溢流污染过程中应用广泛,通过结合南宁市那平江流域治理的工程实例,总结设计经验,从降雨特点、现状管网、实施环境及工程投资等方面入手,总结调蓄池池容、单层及双层调蓄池形式、池体冲洗方式以及气体除臭方式的比选与确定。监测该工程调蓄池的运行情况,分析调蓄池对合流制溢流污染的削减作用,表明调蓄池的建设可增加截流系统整体截流倍数,降低溢流频次,减少合流制溢流污染的发生,增强整个排水系统的韧性。 展开更多
关键词 合流制溢流污染 污染控制 调蓄池 工程实例 设计要点
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部