In this work,the thermal behavior of fin made of palladium material under the influences of thermal radiation and internal heat generation is investigated.The thermal model for the extended surface made of palladium a...In this work,the thermal behavior of fin made of palladium material under the influences of thermal radiation and internal heat generation is investigated.The thermal model for the extended surface made of palladium as the fin material is first developed and solved numerically using finite difference method.The influences of the thermal model parameters on the heat transfer behaviour of the extended surface are investigated.The results show that the rate of heat transfer through the fin and the thermal efficiency of the fin increase as the thermal conductivity of the fin material increases.This shows that fin is more efficient and effective for a larger value of thermal conductivity.However,the thermal conductivity of the fin with palladium material is low and constant at the value of approximately 75 W/mK in a wider temperature range of-100℃and 227℃.Also,it is shown that the thermal efficiencies of potential materials(except for stainless steel and brass)for fins decrease as the fin temperatures increase.This is because the thermal conductivities of most of the materials used for fins decreases as temperature increases.However,keeping other fin properties and the external conditions constant,the thermal efficiency of the palladium is constant as the temperature of the fin increases within the temperature range of-100℃and 227℃.And outside the given range of temperature,the thermal conductivity of the material increases which increases the efficiency of the fin.The study will assist in the selection of proper material for the fin and in the design of passive heat enhancement devices under different applications and conditions.展开更多
On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and an...On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.展开更多
In order to comply with the recent demand for downsizing of the electric equipment, the minia- turization and the improvement in heat transfer performance of a heat sink under natural air-cooling are increasingly requ...In order to comply with the recent demand for downsizing of the electric equipment, the minia- turization and the improvement in heat transfer performance of a heat sink under natural air-cooling are increasingly required. This paper describes the experimental and numerical investigations of heat sinks with miniature/micro pins and the effect of the pin size, pin height and the number of pins on heat transfer characteristics of heat sinks. Five types of basic heat sink models are investigated in this study. The whole heat transfer area of heat sinks having the different pin size, pin height and the number of pins respectively is kept constant. From a series of experiments and numerical analyses, it has been clarified that the heat sink temperature rises with increase in the number of pins. That is, the heat sink with miniaturized fine pins showed almost no effect on the heat transfer enhancement. This is because of the choking phenomenon occurred in the air space among the pin fins. Reflecting these results, it is confirmed that the heat transfer coefficient reduces with miniaturization of pins. Concerning the effects of the heat transfer area on the heat sink performance, almost the same tendency has been observed in other three series of large surface area, that is, higher pin height. Furthermore as a result of studying non-dimensional convection heat transfer performance, it was found that the relation between the Nusselt number (Nu) and the Rayleight number (Ra) is given by Nu = 0.16 Ra0.52.展开更多
Channel structure has a significant effect on the heat transfer performance of PCHE.In this study,a set of rectangular straight channel PCHEs with different cross-section aspect ratios had been tested on S-CO_(2) heat...Channel structure has a significant effect on the heat transfer performance of PCHE.In this study,a set of rectangular straight channel PCHEs with different cross-section aspect ratios had been tested on S-CO_(2) heat transfer experimental platform,the effect of mass flow rate in both cold and heat sides,as well as the cross-section aspect ratio of the rectangular straight channel,on the heat transfer performance of PCHE was investigated.The results show that the comprehensive heat transfer performance of the rectangular cross-section is better than that of the semicircular cross-section;increasing the aspect ratio can improve the comprehensive heat transfer performance of PCHE,but the strengthening effect diminishes as the aspect ratio increases.Increasing the mass flow rate on both sides not only enhances the pre-cooler's cooling capacity and heat transfer,but also raises the pressure drop.In addition,an improved heat transfer correlation for rectangular cross-section PCHE was proposed,considering the effects of cross-sectional aspect ratio and pseudo-critical temperature is proposed in the range of Re from 3169 to 48474 and Pr from 0.98 to 12.5,the fited results better predict the local Nu and f magnitudes and trends in the pre-cooler under different cooling conditions,outperforming the simulated data and Gnielinski and Blasius correlation.展开更多
文摘In this work,the thermal behavior of fin made of palladium material under the influences of thermal radiation and internal heat generation is investigated.The thermal model for the extended surface made of palladium as the fin material is first developed and solved numerically using finite difference method.The influences of the thermal model parameters on the heat transfer behaviour of the extended surface are investigated.The results show that the rate of heat transfer through the fin and the thermal efficiency of the fin increase as the thermal conductivity of the fin material increases.This shows that fin is more efficient and effective for a larger value of thermal conductivity.However,the thermal conductivity of the fin with palladium material is low and constant at the value of approximately 75 W/mK in a wider temperature range of-100℃and 227℃.Also,it is shown that the thermal efficiencies of potential materials(except for stainless steel and brass)for fins decrease as the fin temperatures increase.This is because the thermal conductivities of most of the materials used for fins decreases as temperature increases.However,keeping other fin properties and the external conditions constant,the thermal efficiency of the palladium is constant as the temperature of the fin increases within the temperature range of-100℃and 227℃.And outside the given range of temperature,the thermal conductivity of the material increases which increases the efficiency of the fin.The study will assist in the selection of proper material for the fin and in the design of passive heat enhancement devices under different applications and conditions.
文摘On the basis of practical projects in Chongqing,the thermal performance of heat exchangers (single U-tube type and double U-tube type) of the ground-source heat pump (GSHP) system in the hot summer was obtained and analyzed. The data obtained from test could match with the result deduced from theoretical calculation. From the test results,the cooling capacity of double U-tube is 1.6 times that of single U-tube. Taking cost per depth per watt Clq as the evaluation standard,Clq of single U-tube is 4.69 RMB$/W,and Clq of double U-tube is 3.14 RMB$/W. The double U-tube heat exchangers usage should be prioritized.
文摘In order to comply with the recent demand for downsizing of the electric equipment, the minia- turization and the improvement in heat transfer performance of a heat sink under natural air-cooling are increasingly required. This paper describes the experimental and numerical investigations of heat sinks with miniature/micro pins and the effect of the pin size, pin height and the number of pins on heat transfer characteristics of heat sinks. Five types of basic heat sink models are investigated in this study. The whole heat transfer area of heat sinks having the different pin size, pin height and the number of pins respectively is kept constant. From a series of experiments and numerical analyses, it has been clarified that the heat sink temperature rises with increase in the number of pins. That is, the heat sink with miniaturized fine pins showed almost no effect on the heat transfer enhancement. This is because of the choking phenomenon occurred in the air space among the pin fins. Reflecting these results, it is confirmed that the heat transfer coefficient reduces with miniaturization of pins. Concerning the effects of the heat transfer area on the heat sink performance, almost the same tendency has been observed in other three series of large surface area, that is, higher pin height. Furthermore as a result of studying non-dimensional convection heat transfer performance, it was found that the relation between the Nusselt number (Nu) and the Rayleight number (Ra) is given by Nu = 0.16 Ra0.52.
基金supported by the National Natural Science Foundation of China(52276150).
文摘Channel structure has a significant effect on the heat transfer performance of PCHE.In this study,a set of rectangular straight channel PCHEs with different cross-section aspect ratios had been tested on S-CO_(2) heat transfer experimental platform,the effect of mass flow rate in both cold and heat sides,as well as the cross-section aspect ratio of the rectangular straight channel,on the heat transfer performance of PCHE was investigated.The results show that the comprehensive heat transfer performance of the rectangular cross-section is better than that of the semicircular cross-section;increasing the aspect ratio can improve the comprehensive heat transfer performance of PCHE,but the strengthening effect diminishes as the aspect ratio increases.Increasing the mass flow rate on both sides not only enhances the pre-cooler's cooling capacity and heat transfer,but also raises the pressure drop.In addition,an improved heat transfer correlation for rectangular cross-section PCHE was proposed,considering the effects of cross-sectional aspect ratio and pseudo-critical temperature is proposed in the range of Re from 3169 to 48474 and Pr from 0.98 to 12.5,the fited results better predict the local Nu and f magnitudes and trends in the pre-cooler under different cooling conditions,outperforming the simulated data and Gnielinski and Blasius correlation.