In certain exceptional cases,capillary samples must be used to measure X-ray absorption spectra(XAS).However,the inho-mogeneous thickness of capillary samples causes XAS distortion.This study discusses the distortion ...In certain exceptional cases,capillary samples must be used to measure X-ray absorption spectra(XAS).However,the inho-mogeneous thickness of capillary samples causes XAS distortion.This study discusses the distortion and correction of the XAS curve caused by the inhomogeneous thickness of capillary samples.The relationship between the distorted XAS curveμ′d_(eq)(measured values)and the real absorption coefficientμ_(s)d_(eq)(true values)of the sample was established.The distortion was slight and negligible when the vertical size(2h)of the X-ray beam spot was smaller than 60%of the capillary tube’s inner diameter(2R_(in)).When h/R_(in)>1,X-ray leakage is inevitable and should be avoided during measurement.Partial X-ray leakage caused by an X-ray beam spot size larger than the inner diameter of the capillary tube leads to serious compressed distortion of the XAS curve.When h/R_(in)<1,the distorted XAS data were well corrected.Possible errors and their influence on the corrected XAS are also discussed.Simulations and corrections for distortions verify the feasibility and effectiveness of the corrected method.展开更多
基金the National Key R&D Program of China(Nos.2022YFA1603802 and 2017YFA0403000)1W2B and 4B9A at the Beijing Synchrotron Radiation Facility.
文摘In certain exceptional cases,capillary samples must be used to measure X-ray absorption spectra(XAS).However,the inho-mogeneous thickness of capillary samples causes XAS distortion.This study discusses the distortion and correction of the XAS curve caused by the inhomogeneous thickness of capillary samples.The relationship between the distorted XAS curveμ′d_(eq)(measured values)and the real absorption coefficientμ_(s)d_(eq)(true values)of the sample was established.The distortion was slight and negligible when the vertical size(2h)of the X-ray beam spot was smaller than 60%of the capillary tube’s inner diameter(2R_(in)).When h/R_(in)>1,X-ray leakage is inevitable and should be avoided during measurement.Partial X-ray leakage caused by an X-ray beam spot size larger than the inner diameter of the capillary tube leads to serious compressed distortion of the XAS curve.When h/R_(in)<1,the distorted XAS data were well corrected.Possible errors and their influence on the corrected XAS are also discussed.Simulations and corrections for distortions verify the feasibility and effectiveness of the corrected method.