期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Ion dynamics into different pore size distributions in supercapacitors under compression
1
作者 João Pedro Aguiar dos Santos Cesar J.B.Pagan +4 位作者 Rafael Vicentini Reinaldo F.Teófilo Renato Beraldo Leonardo M.Da Silva Hudson Zanin 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第5期110-119,I0004,共11页
Compressing supercapacitor(SCs)electrode is essential for improving the energy storage characteristics and minimizing ions’distance travel,faradaic reactions,and overall ohmic resistance.Studies comprising the ion dy... Compressing supercapacitor(SCs)electrode is essential for improving the energy storage characteristics and minimizing ions’distance travel,faradaic reactions,and overall ohmic resistance.Studies comprising the ion dynamics in SC electrodes under compression are still rare.So,the ionic dynamics of five aqueous electrolytes in electrodes under compression were studied in this work for tracking electrochemical and structural changes under mechanical stress.A superionic state is formed when the electrode is compressed until the micropores match the dimensions with the electrolyte’s hydrated ion sizes,which increases the capacitance.If excessive compression is applied,the accessible pore regions decrease,and the capacitance drops.Hence,as the studied hydrated ions have different dimensions,the match between ion/pore sizes differs.To the LiOH and NaClO4electrolytes,increasing the pressure from 60 to 120 and 100 PSI raised the capacitance from 13.5 to 35.2 F g^(-1)and 30.9 to 39.0 F g^(-1),respectively.So,the KOH electrolyte with the lowest and LiCl with the biggest combination of hydrated ion size have their point of maximum capacitance(39.5 and 36.7F g^(-1))achieved at 140 and 80 PSI,respectively.To LiCl and KCl electrolytes,overcompression causes a drop in capacitance higher than 23%. 展开更多
关键词 Mechanic compression Pore size distribution lon dynamics Activated carbon SUPERCAPACITORS
下载PDF
Mechanical compression management of the right middle cerebral artery inferior trunk using a stent during coil embolization of middle cerebral artery aneurysms:A case report and literature review
2
作者 Zhengyu Wang Zhiqing Peng +2 位作者 Liang Chen Wanbin Li Yongli Wang 《Journal of Interventional Medicine》 2023年第3期126-129,共4页
Endovascular coil embolization is a minimally invasive,rapid,and effective method for the treatment of intracranial aneurysms.However,complications associated with coil embolization,such as intraoperative aneurysm rup... Endovascular coil embolization is a minimally invasive,rapid,and effective method for the treatment of intracranial aneurysms.However,complications associated with coil embolization,such as intraoperative aneurysm rupture or arterial occlusion,should be promptly managed during the procedure to avoid catastrophic consequences.This study presents a case of mechanical compression management of the right middle cerebral artery(MCA)inferior trunk during coil embolization for bilateral MCA aneurysms.The inferior trunk of the right MCA was abruptly occluded due to mechanical compression during coil embolization of the right MCA bifurcation aneurysm.A Solitaire AB stent(4×20 mm,Covidien/Medtronic,Dublin,Ireland)was implanted in the inferior trunk of the right MCA after tirofiban was injected via a microcatheter,and the right inferior trunk was recanalized.The patient also underwent coil embolization of the left MCA bifurcation aneurysm,without any complications.It is crucial to recognize compressive occlusion of adjacent aneurysm branches to avoid severe complications during intracranial aneurysm embolization.Stent placement is a rescue treatment option for recanalization of an occluded artery. 展开更多
关键词 Endovascular coil embolization Intracranial aneurysm Mechanical compression STENT
下载PDF
Varying of up-conversion nanoparticles luminescence from the muscle tissue depth during the compression 被引量:1
3
作者 Marina Kozintseva Vyacheslav Kochubey +1 位作者 Julia Konyukhova Valery Tuchin 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2021年第5期85-92,共8页
The current work is focused on the study of optical clearing of skeletal muscles under local compression.The experiments were performed on in vitro bovine skeletal muscle.The time dependence of optical clearing was st... The current work is focused on the study of optical clearing of skeletal muscles under local compression.The experiments were performed on in vitro bovine skeletal muscle.The time dependence of optical clearing was studied by monitoring the luminescence intensity of NaYF_(4)∶Er,Yb upconverting particles located under tissue layers.This study shows the possibility to use upconverting nanoparticles(UCNPs)both for studying the dynamics of the optical clearing of biological tissue under compression and to detect moments of cell wall damage under excessive pressure.The advantage of using UCNPs is the presence of several bands in their luminescence spectra,located both at close wavelengths and far apart. 展开更多
关键词 Upconverting particle biological tissue skeletal muscle tissue tissue optical clearing luminescence imaging technique mechanical compression
下载PDF
COMPRESSIVE COMMINUTION MECHANISM OF PARTICLE BEDS
4
作者 Yaojianqian Guo Nianqin +1 位作者 Huang Peng peng Ouyang Zhentang 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 1992年第4期1-7,共7页
Granular material mechanics,finite element analysis and crushing theory are applied to study the compressive comminution mechanism of particle beds in this paper.This is a new method by which we have established an eq... Granular material mechanics,finite element analysis and crushing theory are applied to study the compressive comminution mechanism of particle beds in this paper.This is a new method by which we have established an equivalent model of granular material,determined the values and distributions of contact forces and discovered a crushing law.The model has been tested on the newly designed equipment and proved to be correct.Some new characteristics and laws of compressive comminution of particle beds have been found. 展开更多
关键词 compressive comminution mechanism granular material equivalent model test machine of compressive comminution of particle beds
下载PDF
A Chest Compression Quality Evaluation Using Mechanical Chest Compressions under Different Working Situations in the Ambulance
5
作者 Par Lindblad Annika Astrom Victoren +1 位作者 Christer Axelsson Bjarne Madsen Hardig 《International Journal of Clinical Medicine》 2015年第8期530-537,共8页
Objectives: The aim of this study was to analyze the quality of chest compressions in different working situations pertaining to ambulance crews using either standard chest compressions (S-CC) or LUCAS mechanical ches... Objectives: The aim of this study was to analyze the quality of chest compressions in different working situations pertaining to ambulance crews using either standard chest compressions (S-CC) or LUCAS mechanical chest compressions (L-CC) in a manikin setting. Participants and Methods: Cardiopulmonary resuscitation (CPR) was performed using a compression to ventilation ratio of 30:2 with both S-CC and L-CC. Quality parameters were collected using a modified manikin enabling impedance measurements. The evaluation was performed in two manikin scenarios: Scenario 1 evaluated ten minutes of CPR on the ground and Scenario 2 assessed six minutes of CPR in different settings relevant to work in the ambulance. Quality parameters compared were: time to apply LUCAS, hands-off fraction, number of correct chest compressions and the rate of compressions. Results: In Scenario 1 the hands-off fraction was higher when S-CC was performed (S-CC group 29% vs. L-CC 16%, P = 0.003). We found a higher number of chest compressions (S-CC = 913 vs. L-CC = 831, P = 0.0049) and a higher rate of chest compressions (S-CC = 118 vs. L-CC = 99, P < 0.0001) in the S-CC group. In Scenario 2 we noted a higher hands-off fraction for S-CC (39% vs. L-CC = 19%, P = 0.003), but a higher number of compressions given during S-CC ((n = 504) vs. L-CC (n = 396) P = 0.0002). Conclusion: Mechanical chest compression with the LUCAS 2TM device enables ambulance personnel to provide high quality chest compression even while transporting the patient. 展开更多
关键词 Cardiac Arrest Mechanical Chest compression External Chest compressions LUCAS CPR RESUSCITATION
下载PDF
Strain-rate Sensitivity of Aluminum 2024-T6/TiB_2 Composites and Aluminum 2024-T6 被引量:1
6
作者 朱德智 郑振兴 CHEN Qi 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2015年第2期256-260,共5页
Strain-rate sensitivities of 55vol%-65vol% aluminum 2024-T6/TiB2 composites and the corresponding aluminum 2024-T6 matrix were investigated using split Hopkinson pressure bar method. The experimental results showed th... Strain-rate sensitivities of 55vol%-65vol% aluminum 2024-T6/TiB2 composites and the corresponding aluminum 2024-T6 matrix were investigated using split Hopkinson pressure bar method. The experimental results showed that 55vol%-65vol% aluminum 2024-T6/TiB2 composites exhibited significant strain-rate sensitivities, which were three times higher than the strain-rate sensitivity of the aluminum 2024-T6 matrix. The strain-rate sensitivity of the aluminum 2024-T6 matrix composites rose obviously with increasing reinforcement content(up to 60%), which agreed with that from the previous researches. But it decreased as the ceramic reinforcement content reached 65%. After high strain rates compression, a large number of dislocations and micro-cracks were found inside the matrix and the Ti B2 particles, respectively. These micro-cracks can accelerate the brittle fracture of the composites. The aluminum 2024-T6/Ti B2 composites showed various fracture characteristics and shear instability was the predominant failure mechanism under dynamic loading. 展开更多
关键词 composite materials mechanical properties dynamic compression strain-rate sensitivity
下载PDF
COMPRESSIVE MECHANICAL PROPERLIES AND FRACTURE MORPHOLOGY OF Zr_(52.5)Cu_(17.9)Ni_(14.6)Al_(10)Ti_5 BULKYAMORPHOUS ALLOY
7
《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2000年第6期1141-1147,共7页
关键词 COMPRESSIVE MECHANICAL PROPERLIES AND FRACTURE MORPHOLOGY OF Zr Ti5 BULKYAMORPHOUS ALLOY Al CU NI
下载PDF
Investigate the Effect of the Magnetic Field on the Mechanical Properties of Silicone Rubber-Based Anisotropic Magnetorheological Elastomer during Curing Process
8
作者 Tao Li Ali Abd El-Aty +7 位作者 Cheng Cheng Yizhou Shen Cong Wu Qiucheng Yang Shenghan Hu Yong Xu Jie Tao Xunzhong Guo 《Journal of Renewable Materials》 SCIE EI 2020年第11期1411-1427,共17页
In this investigation,a new silicone rubber-based MRE material was prepared to be used as a forming medium in manufacturing thin-walled complexshaped Ni-based tubes through the bulging process.Thus,it is significant ... In this investigation,a new silicone rubber-based MRE material was prepared to be used as a forming medium in manufacturing thin-walled complexshaped Ni-based tubes through the bulging process.Thus,it is significant to investigate the effect of magnetic field intensity,magnetic field loading time,and angle on the mechanical properties of the prepared MRE material during the curing process.The obtained results showed that increasing the magnetic field intensity during the curing process can improve the orientation of the chain structure in the elastomer matrix effectively.However,its mechanical properties are the best under the corresponding magnetic field intensity of 321 mT.Besides,by extending the magnetic field loading time in the curing process,the orientation of the chain structure was optimized,at the same time,the mechanical properties were also improved,and the best loading time is about 20–25 min.By changing the loading angle of the magnetic field during the curing process,the mechanical properties of the MRE were improved.When the loading angle of the magnetic field is 90°,the elastomer showed the best compression mechanical properties and excellent compression reversibility.Besides,for the anisotropic MRE material,the performance with magnetic compression is always better than that without magnetic compression. 展开更多
关键词 Magnetorheological Elastomer(MRE) magnetic field curing process compression mechanical properties chain structure
下载PDF
Enhanced Strength and Ductility Due to Microstructure Refinement and Texture Weakening of the GW102K Alloy by Cyclic Extrusion Compression 被引量:9
9
作者 Jinbao Lin Xinyi Wang +2 位作者 Weijie Ren Xuexia Yang Qudong Wang 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2016年第8期783-789,共7页
The cyclic extrusion compression (CEC) was applied to severely deform the as-extruded GW102K (Mg- 10.0Gd-2.0Y-0.5Zr, wt%) alloy at 350, 400, and 450 ℃, respectively. The microstructure, texture, and grain boundar... The cyclic extrusion compression (CEC) was applied to severely deform the as-extruded GW102K (Mg- 10.0Gd-2.0Y-0.5Zr, wt%) alloy at 350, 400, and 450 ℃, respectively. The microstructure, texture, and grain boundary character distribution of the CECed alloy were investigated in the present work. The mechan- ical properties were measured by uniaxial tension at room temperature. The crack initiation on the longitudinal section near the tensile fracture-surface was investigated by high-resolution scanning elec- tron microscopy (SEM). The result shows that the microstructure was dramatically refined by dynamic recrystallization (DRX). The initial fiber texture was disintegrated and obviously weakened. The 8-passes/ 350 ℃ CECed alloy exhibited yield strength of 318 MPa with an elongation-to-fracture of 16.8%, increased by 41.3% and 162.5%, respectively. Moreover, the elongation-to-fracture of the 8-passes/450 ℃ CECed alloy significantly increased more than 3 times than that of the received alloy. The cracks were mainly initi- ated at twin boundaries and second phase/matrix interfaces during tensile deformation. The microstructure refinement was considered to result in the dramatically enhanced of the strength and ductility. In ad- dition, the texture randomization during CEC is beneficial for enhancing ductility. The standard positive Hall-Petch relationships have been obtained for the CECed GW102K alloy. 展开更多
关键词 Cyclic extrusion compression (CEC) Mechanical properties Magnesium alloy Electron hackscatter diffraction (EBSD) Texture
原文传递
Utilization of mechanical compression as a disinfestation technique for Hessian fly(Mayetiola destructor(say))in timothy hay:Field test
10
作者 Lope G.Tabil S.Talebi +1 位作者 M.D.Shaw W.J.Crerar 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2011年第4期12-20,共9页
Baled timothy hay underwent testing at a hay processing plant in Canada to determine if mechanical compression(rebaling)could be used as a disinfestation protocol for Hessian fly(Mayetiola destructor(Say))puparia.Pres... Baled timothy hay underwent testing at a hay processing plant in Canada to determine if mechanical compression(rebaling)could be used as a disinfestation protocol for Hessian fly(Mayetiola destructor(Say))puparia.Pressure sensitive films were randomly placed throughout the hay material,on the chamber walls,and in different orientations,to assess the hay compaction unit’s ability to induce the required pressure to crash a Hessian fly puparium in the hay.Attached to the pressure films were organdy cages containing wheat seedlings infested with Hessian fly puparia.The variables which were tested included the hold time(0.5 and 2.0 s),applied pressure(10.34 and 12.41 MPa),and timothy hay quality(low-moisture first cut,high-moisture first cut and high-moisture second cut hay).A total of 36 tests were conducted.For each test,10 Hessian fly cages and 10 pressure sensitive films were used.Each test cage contained approximately 168.56 Hessian fly puparia,translating into a total Hessian fly count of 60681 for the entire field test.Analysis of the pressure sensitive films showed that 100%of the hay experienced at least 200 kPa(29 psi)of pressure.Following the 75-day post experiment emergence period,0.0066%of the puparia survived,which may be due to the fact that the emerged puparia might have not been crushed and not subjected to a pressure of at least 20.6 kPa.The applied pressures affected Hessian fly emergence by considerably reducing the number of puparia that emerged.However,Hessian fly emerged from one of the cages in two tests.Most of the Hessian fly puparia were destroyed irrespective of the applied pressure,hold time or hay quality. 展开更多
关键词 mechanical compression Hessian fly DISINFESTATION hay bale rebaling emergence
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部