BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with t...BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis.展开更多
BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMA...BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMARY We describe the case of a 34-year-old male,who underwent both MDC and MRI examinations of the upper abdomen because of liver cirrhosis.MDCT and MRI angiography images of the upper abdomen revealed an anatomic variation of the superior mesenteric vein(SMV),the double SMVs.CONCLUSION The double SMVs are a congenital abnormality without potential clinical manifestation.Physicians need to be aware of this anatomical variation during abdominal surgery to avoid iatrogenic injury.展开更多
In order to investigate the effects of two mineral admixtures (i. e., fly ash and ground slag)on initial defects existing in concrete microstructures, a high-resolution X-ray micro-CT( micro-focus computer tomogra...In order to investigate the effects of two mineral admixtures (i. e., fly ash and ground slag)on initial defects existing in concrete microstructures, a high-resolution X-ray micro-CT( micro-focus computer tomography)is employed to quantitatively analyze the initial defects in four series of highperformance concrete (HPC)specimens with additions of different mineral admixtures. The nigh-resolution 3D images of microstructures and filtered defects are reconstructed by micro- CT software. The size distribution and volume fractions of initial defects are analyzed based on 3D and 2D micro-CT images. The analysis results are verified by experimental results of watersuction tests. The results show that the additions of mineral admixtures in concrete as cementitious materials greatly change the geometrical properties of the microstructures and the spatial features of defects by physical-chemistry actions of these mineral admixtures. This is the major cause of the differences between the mechanical behaviors of HPC with and without mineral admixtures when the water-to-binder ratio and the size distribution of aggregates are constant.展开更多
Hepatocellular carcinoma (HCC) is one of the most common primary cancers in the world. Surgery is the gold standard for treatment of patients with HCC. Recurrence and metastasis are the major obstacles to further im...Hepatocellular carcinoma (HCC) is one of the most common primary cancers in the world. Surgery is the gold standard for treatment of patients with HCC. Recurrence and metastasis are the major obstacles to further improve the prognosis of HCC. Most recurrences are intrahepatic. However, 30% of the recurrences are extrahepatic. The role of resection in intrahepatic recurrences is widely accepted. The role of resection in extrahepatic HCC recurrence and metastasis is not well established. 18F fluorodeoxyglucose (18F-FDG) positron emission tomography/computer tomography (PET/CT) is useful in detecting distant metastasis from a variety of malignancies and shows superior accuracy to conventional imaging modalities in identification of intrahepatic and extrahepatic metastasis. We present one patient with one new isolated omental lymph node metastasis, who had a history of huge HCC resected six years ago. The metastatic focus was identified with 18 F-FDG PET/CT and resected. The follow-up revealed good prognosis with a long-term survival potential after resection of the omental lymphatic metastasis.展开更多
AIM: To assess the ability of ^18F-fluorodeoxyglucose positron emission tomography/computer tomography (^18F-FDG PET/CT) to differentiate between benign and malignant portal vein thrombosis in hepatocellular carcin...AIM: To assess the ability of ^18F-fluorodeoxyglucose positron emission tomography/computer tomography (^18F-FDG PET/CT) to differentiate between benign and malignant portal vein thrombosis in hepatocellular carcinoma (HCC) patients.METHODS: Five consecutive patients who had HBV cirrhosis, biopsy-proven HCC, and thrombosis of the main portal vein and/or left/right portal vein on ultrasound (US), computer tomography (CT) or magnetic resonance imaging (MRI) were studied with ^18F-FDG PET/CT. The presence or absence of a highly metabolic thrombus on ^18F-FDG PET/CT was considered diagnostic for malignant or benign portal vein thrombosis, respectively. All patients were followed-up monthly with US, CT or MRI. Shrinkage of the thrombus or recanalization of the vessels on US, CT or MRI during follow-up was considered to be definitive evidence of the benign nature of the thrombosis, whereas enlargement of the thrombus, disruption of the vessel wall, and parenchymal infiltration over follow-up were considered to be consistent with malignancy. ^18SF-FDG PET/CT, and US, CT or MRI results were compared.RESULTS: Follow-up (1 to 10 mo) showed signs of malignant thrombosis in 4 of the 5 patients. US, CT or MRI produced a true-positive result for malignancy in 4 of the patients, and a false-positive result in 1. ^18F-FDG PET/CT showed a highly metabolic thrombus in 4 of the 5 patients. ^18F-FDG PET/CT achieved a true-positive result in all 4 of these patients, and a true-negative result in the other patient. No false-positive result was observed using ^18F-FDG PET/CT.CONCLUSION: ^18F-FDG PET/CT may be helpful in discriminating between benign and malignant portal vein thrombi. Patients may benefit from ^18F-FDG PET/CT when portal vein thrombi can not be diagnosed exactly by US, CT or MRI.展开更多
AIMTo measure optic nerve sheath diameters (ONSD) in different locations by computer tomography (CT) and to recommend the best location for cases when ONSD is used for intracranial pressure monitoring.METHODSIn a pros...AIMTo measure optic nerve sheath diameters (ONSD) in different locations by computer tomography (CT) and to recommend the best location for cases when ONSD is used for intracranial pressure monitoring.METHODSIn a prospective cohort study, CT data of 300 healthy adults were analyzed (600 eyes). In all cases, the CT investigation was performed at the Emergency Department because of the various conditions that proved not to be connected with ophthalmological or neurological pathology. The ONSD were measured at 3 mm and 8 mm distance from the globe, and 3 mm from the anterior opening of the optic canal. The correlation analysis was performed with gender, age, and ethnic background.RESULTSThe right/left ONSD are 4.94±1.51/5.17±1.34 mm at 3 mm, 4.35±0.76/4.45±0.62 mm at 8 mm from the globe, and 3.55±0.82/3.65±0.7 mm at 3 mm from the optic canal. No significant differences correlated with gender of the patients, their age, and ethnic background were found.CONCLUSIONIn healthy persons, the ONSD varies from 5.17±1.34 mm to 3.55±0.82 mm in different locations within the intraorbital space. The most stable results with lesser standard deviation can be obtained if it is measured 8-10 mm from the globe.展开更多
Pistons used in automobile engines are made of aluminum alloy; and endurance of high pressure and high temperature is required. Recently, high strength pistons are needed to cope with the increase of pressure and temp...Pistons used in automobile engines are made of aluminum alloy; and endurance of high pressure and high temperature is required. Recently, high strength pistons are needed to cope with the increase of pressure and temperature in the engine cylinder. A high strength piston is possible when the piston casting has little or no casting defects, such as micro-pores and cracks. Generally the defects can be evaluated by non-destructive testing (NDT), and the most efficient ways for evaluation are using ultrasonics and computer tomography. In the present study, two NDT methods were compared and evaluated to investigate the defects in the aluminum piston castings. Artificial defects were machined by using very small drill bits with diameters 1, 0.5, 0.3, 0.2 and 0.1 mm. The defects were investigated by using an ultrasonic tester and a computer tomography system. Defects smaller than 0.3 mm may not be found by using the ultrasonic test, but the defects may be found by using the computer tomography system. The investigation conditions for detecting small defects and the scanning time for in-line defect analysis are discussed in the present study.展开更多
BACKGROUND Esophagojejunal anastomotic leakage(EJAL)is a serious and potentially crucial complication of total gastrectomy and represents the major cause of postoperative death,with a mortality rate of up to 50%.Howev...BACKGROUND Esophagojejunal anastomotic leakage(EJAL)is a serious and potentially crucial complication of total gastrectomy and represents the major cause of postoperative death,with a mortality rate of up to 50%.However,treatment remains challenging and controversial.We report here the case of a patient whose intrathoracic EJAL was successfully treated with computer tomography(CT)-guided negative pressure drainage treatment.CASE SUMMARY A 69-year-old male patient complained of difficulty swallowing within the last six months.He was diagnosed with esophagogastric junction carcinoma,Siewert II,cT3N0M0 stage II.Total gastrectomy and Roux-en-Y esophagojejunostomy were performed.High fever,left chest pain and dyspnea appeared on postoperative day 5,and EJAL was confirmed by CT,gastroscopy and oral blue-dimethylene tests.Conservative treatment measures were applied immediately,including antibiotics,nasojejunal tubes,and repeated thoracic puncture and drainage under ultrasound guidance.However,without sufficient and effective drainage,the thoracic infection and systemic condition continued to deteriorate.With the cooperation of multiple departments,percutaneous CT-guided drainage(24 Fr 7 mm)in the thoracic cavity was successfully placed near the anastomotic leakage.Because of continuous negative pressure suction,the infection symptoms were effectively controlled and the general situation gradually recovered.Subsequent follow-up examination showed that the patient was in good condition.CONCLUSION Negative pressure drainage via CT may represent an effective minimally invasive approach to treating intrathoracic EJAL.展开更多
BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderat...BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE). OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations. DESIGN : Contrast observation SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College. PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHOOS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM. TCD and CT examinations. RESULTS: All the 416 infant patients with HIE participated in the result analysis. (1) Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0% (22/130 ),x^2=41.66 ;29.2% ( 38/130 ) vs. 6.2% ( 8/130 ), x^2=23.77, P 〈 0.01 ], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. (2) Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8% (178/196),78.6% (154/196),x^2=4.32,P 〈 0.05;64.3% (126/196),43.9% (86/196) ,x^2=16.44 ;44.9% (88/196) ,22.4% (44/196),x^2=22.11 ;21.4% (42/196), 10.2% (20/196),x^2=9.27, P 〈 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24^th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1^st month after birth, and all the patients recovered to the normal in the 3^rd month after birth, while CT examination showed that mild abnormality still existed in the 24^th month after birth (1.0% ,2/196). (3) Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1^st, 3^rd, 6^th and 12^th months after birth[86.7% (78/90),44.4% (40/90),x^2=35.53;62.2% (56/90),31.1% (28/90),x^2=17.51 ;37.8% (34/90),6.7% (6/90), x^2=27.14, P 〈 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24^th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3^rd month after birth, and all the infant patients recovered in the 6^th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12^th month after birth, and all of infant patients recovered to the normal in the 24^th month after birth.CONCLUSION : BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination.展开更多
Background The diagnosis of Parkinson’s disease is presently based on non-specific symptoms. However, radionuclide dopamine transporters imaging can provide specific diagnostic tool for Parkinson’s disease. This st...Background The diagnosis of Parkinson’s disease is presently based on non-specific symptoms. However, radionuclide dopamine transporters imaging can provide specific diagnostic tool for Parkinson’s disease. This study was designed to investigate the effects of imaging of dopamine transporters with 99mTc-TRODAT-1 in early diagnosis or differential diagnosis of Parkinson’s disease.Methods Nine normal monkeys were used to establish N-methyl-4-phenyl-1, 2, 3, 6-tetra-hydropyridine (MPTP) hemi-Parkinsonian animal models, and they were subjected to imaging. Twenty-nine patients with Parkinson’s disease, 12 age-matched healthy volunteers, and 18 age-matched patients with Parkinson’s syndrome were investigated. Single photon emission computer tomography (SPECT) was performed 3 hours after intravenous injection of 740 MBq 99mTc-TRODAT-1. Striatum specific uptake of 99mTc-TRODAT-1 was calculated according to the ratio of striatum (ST) to cerebellum (CB)in dopamine transporters uptake.Results In normal monkeys, bilateral ratio of ST/CB was 2.34±0.41. After the injection of MPTP, uptake rate of 99mTc-TRODAT-1 at damaged region was much lower than that at the contralateral region, resulting in a significant difference in the ratio of ST/CB (right: ST/CB=1.73±0.35; left: ST/CB=1.90±0.30), especially in hemi-Parkinsonian model monkeys (right: ST/CB=1.29±0.17; left: ST/CB=1.80±0.33). The ratios of ST/CB were 1.57±0.17 and 1.61±0.14 for the right and left respectively in the healthy volunteers, 1.04±0.29 and 1.06±0.30 in the age-matched patients with Parkinson’s disease, and 1.56±0.17 and 1.59±0.18 in the age-matched patients with Parkinson’s disease syndrome. A significant difference was noted between group of Parkinson’s disease, normal controls and Parkinson’s disease syndrome. Conclusion The results suggest that 99mTc-TRODAT-1 dopamine transporters SPECT has clinical application value in early diagnosis or differential diagnosis of Parkinson’s disease.展开更多
BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer.The quantitative parameters based on the novel dual-layer spectral detector computed tomography(DLSDCT)in discriminating the...BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer.The quantitative parameters based on the novel dual-layer spectral detector computed tomography(DLSDCT)in discriminating the Ki-67 expression status are unclear.AIM To investigate the diagnostic ability of DLSDCT-derived parameters for Ki-67 expression status in gastric carcinoma(GC).METHODS Dual-phase enhanced abdominal DLSDCT was performed preoperatively in 108 patients with gastric adenocarcinoma.Primary tumor monoenergetic CT attenuation value at 40-100 kilo electron volt(kev),the slope of the spectral curve(λ_(HU)),iodine concentration(IC),normalized IC(nIC),effective atomic number(Z^(eff))and normalized Z^(eff)(nZ^(eff))in the arterial phase(AP)and venous phase(VP)were retrospectively compared between patients with low and high Ki-67 expression in gastric adenocarcinoma.Spearman’s correlation coefficient was used to analyze the association between the above parameters and Ki-67 expression status.Receiver operating characteristic(ROC)curve analysis was performed to compare the diagnostic efficacy of the statistically significant parameters between two groups.RESULTS Thirty-seven and 71 patients were classified as having low and high Ki-67 expression,respectively.CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),and Z^(eff)-related parameters were significantly higher,but IC-related parameters were lower in the group with low Ki-67 expression status than the group with high Ki-67 expression status,and other analyzed parameters showed no statistical difference between the two groups.Spearman’s correlation analysis showed that CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),Z^(eff),and n Z^(eff) exhibited a negative correlation with Ki-67 status,whereas IC and nIC had positive correlation with Ki-67 status.The ROC analysis demonstrated that the multi-variable model of spectral parameters performed well in identifying the Ki-67 status[area under the curve(AUC)=0.967;sensitivity 95.77%;specificity 91.89%)].Nevertheless,the differentiating capabilities of singlevariable model were moderate(AUC value 0.630-0.835).In addition,the nZ_(VP)^(eff) and nIC_(VP)(AUC 0.835 and 0.805)showed better performance than CT_(40 kev-VP),CT_(70 kev-VP) and CT_(100 kev-VP)(AUC 0.630,0.631 and 0.662)in discriminating the Ki-67 status.CONCLUSION Quantitative spectral parameters are feasible to distinguish low and high Ki-67 expression in gastric adenocarcinoma.Z^(eff) and IC may be useful parameters for evaluating the Ki-67 expression.展开更多
Cystic lesions of the anterior mediastinum in children suggest a well-known group of benign lesions that are comparatively frequent.Thymic cysts(TCs)are mostly positioned in the anterior mediastinum and some patients ...Cystic lesions of the anterior mediastinum in children suggest a well-known group of benign lesions that are comparatively frequent.Thymic cysts(TCs)are mostly positioned in the anterior mediastinum and some patients in the neck.Benign TCs classified as congenital intra-thoracic mesothelial cysts are commonly asymptomatic and have slight clinical significance.Multilocular TC,which can mimic another anterior mediastinal cystic tumor and is seen in adults,is more clinically important.It is a sporadic mediastinal lesion thought to arise in the course of acquired inflammation.Congenital mediastinal cysts represent 3%-6%of all mediastinal tumors and 10%-18%of radiologically reported mediastinal masses.Mediastinal TCs are uncommon and it is hard to know their true incidence.About 60%of cases with mediastinal TCs are asymptomatic,and the remainder of patients complains of nonspecific symptoms(e.g.,chest pain,dyspnea,or cough).The literature suggests that most cysts are benign,but an indefinite percentage may have a neoplastic process and result in significant compressive symptoms over time.Clinical symptoms of TCs vary depending on the location.In addition,frequent symptoms at the appearance of enlarged benign thymic and mediastinal cysts generally contain compressive symptoms(e.g.,respiratory distress,thymic pain,and symptoms related to Horner syndrome,hoarseness,dysphonia,dyspnea,orthopnea,wheezing,and fever).Many TCs have cystic density and a neat border and are simple to diagnose with radiological imaging.However,some TCs are hard to identify before surgery and may be misidentified as thymomas depending on their site and computed tomography results.Excision by thoracotomy,median sternotomy,or video-assisted techniques is essential for conclusive diagnosis,management,and abolition of relapse of anterior mediastinal masses and TCs.Histopathologic examination may be required after surgery.Considering the extent of the mass and the preliminary inability to make a definitive diagnosis,en bloc excision of the cyst was thought to be preferred to circumvent likely complications(e.g.,perforation,spillage of the contents,or incomplete excision).展开更多
Hemopericardium is a common finding at autopsy, but it may represent a challenge for the forensic pathologist when the etiopathologi-cal relationship in causing death is requested. Hemopericardium and cardiac tamponad...Hemopericardium is a common finding at autopsy, but it may represent a challenge for the forensic pathologist when the etiopathologi-cal relationship in causing death is requested. Hemopericardium and cardiac tamponade can be evaluated in living people using radiological techniques, in particular computer tomography (CT). Only a few studies are reported in literature involving post-mortem (PM) cases, where PMCT imaging has been used in order to investigate acute hemopericardium, and they have shown a good accuracy of this technique. Here we report a case involving a 70-year-old white male found dead on the beach, with a medical history of hepatitis C and chronic hypertension with a poor pharmacological response. A PMCT was performed about 3 h after the discovery of the body. The PMCT examination showed an intrapericardial aortic dissection associated to a periaortic hematoma, a sickle-shaped intramural hematoma, a false lumen, and a hemop-ericardium consisting in fluid and clotted blood. In this case, the PMCT was able to identify the cause of death, even though a traditional autopsy was required to confirm the radiological findings. PMCT is a reliable technique, which in chosen cases, can be performed without the need for a traditional autopsy to be carried out.展开更多
BACKGROUND Lupus mesenteric vasculitis(LMV)is a serious condition that may occur as an acute manifestation of gastrointestinal(GI)involvement and is not easily diagnosed by physicians.Delayed diagnosis and treatment o...BACKGROUND Lupus mesenteric vasculitis(LMV)is a serious condition that may occur as an acute manifestation of gastrointestinal(GI)involvement and is not easily diagnosed by physicians.Delayed diagnosis and treatment of LMV may lead to rapid disease progression and can be life threatening.CASE SUMMARY A previously healthy 27-year-old woman presented with abdominal pain following a history of fatigue and consumption of cold water.Laboratory invest-igations,physical examinations,and enhanced abdominal computed tomography(CT)suggested systemic lupus erythematosus complicated by LMV.She received treatments,such as GI decompression,somatostatin,glucocorticoids,and immu-nosuppressants,and was evaluated using color ultrasonography.Twenty days later,the patient reported no stomach discomfort and was able to consume semi-liquid food.Laboratory investigations showed that inflammatory factors decreased to normal levels and complement levels increased slightly.One year after discharged,she recovered with methylprednisolone being tapered to 4 mg per day,mycophenolate mofetil to 0.75 g bid,and hydroxychloroquine to 0.2 g bid;however,only C3 complement level was slightly below the normal level.CONCLUSION Early diagnosis of LMV is essential for successful treatment;this depends on a combination of clinical manifestations,laboratory investigations,and imaging findings.Enhanced CT is preferred,but ultrasonography can be used for prompt screening and follow-up.展开更多
One factor that limits development of fundamental research on the infuence of coke microstructure on its strength is the difculty in quantifying the way that microstructure is both classifed and distributed in three d...One factor that limits development of fundamental research on the infuence of coke microstructure on its strength is the difculty in quantifying the way that microstructure is both classifed and distributed in three dimensions.To support such fundamental studies,this study evaluated a novel volumetric approach for classifying small(approx.450μm^(3))blocks of coke microstructure from 3D computed tomography scans.An automated process for classifying microstructure blocks was described.It is based on Landmark Multi-Dimensional Scaling and uses the Bhattacharyya metric and k-means clustering.The approach was evaluated using 27 coke samples across a range of coke with diferent properties and reliably identifed 6 ordered class of coke microstructure based on the distribution of voxel intensities associated with structural density.The lower class(1–2)subblocks tend to be dominated by pores and thin walls.Typically,there is an increase in wall thickness and reduced pore sizes in the higher classes.Inert features are also likely to be seen in higher classes(5–6).In general,this approach provides an efcient automated means for identifying the 3D spatial distribution of microstructure in CT scans of coke.展开更多
Medical Image Fusion is the synthesizing technology for fusing multi-modal medical information using mathematical procedures to generate better visual on the image content and high-quality image output.Medical image f...Medical Image Fusion is the synthesizing technology for fusing multi-modal medical information using mathematical procedures to generate better visual on the image content and high-quality image output.Medical image fusion represents an indispensible role infixing major solutions for the complicated medical predicaments,while the recent research results have an enhanced affinity towards the preservation of medical image details,leaving color distortion and halo artifacts to remain unaddressed.This paper proposes a novel method of fusing Computer Tomography(CT)and Magnetic Resonance Imaging(MRI)using a hybrid model of Non Sub-sampled Contourlet Transform(NSCT)and Joint Sparse Representation(JSR).This model gratifies the need for precise integration of medical images of different modalities,which is an essential requirement in the diagnosing process towards clinical activities and treating the patients accordingly.In the proposed model,the medical image is decomposed using NSCT which is an efficient shift variant decomposition transformation method.JSR is exercised to extricate the common features of the medical image for the fusion process.The performance analysis of the proposed system proves that the proposed image fusion technique for medical image fusion is more efficient,provides better results,and a high level of distinctness by integrating the advantages of complementary images.The comparative analysis proves that the proposed technique exhibits better-quality than the existing medical image fusion practices.展开更多
Colorectal cancer (CRC) remains a leading cancer killer worldwide. But the disease is both curable and preventable at an early stage. Regular CRC cancer screening has been shown to reduce the risk of dying from CRC. H...Colorectal cancer (CRC) remains a leading cancer killer worldwide. But the disease is both curable and preventable at an early stage. Regular CRC cancer screening has been shown to reduce the risk of dying from CRC. However, the importance of large-scale screening is only now starting to be appreciated. This article reviews a variety of imaging procedures available for detecting ulcerative colitis (UC) and Crohn's disease (CD), polyps and CRC in their early stage and also presents details on various screening options. Detecting, staging and re-staging of patients with CRC also require multimodality, multistep imaging approaches. Staging and re-staging with conventional colonoscopy (CC), computer tomography colonography (CTC), magnetic resonance colonography (MRC) and positron emission tomography/computer tomography colonography (PET/CTC) are of paramount importance in determining the most appropriate therapeutic method and in predicting the risk of tumor recurrence and overall prognosis. The advantages and limitations of these modalities are also discussed.展开更多
We report a 55-year-old male who developed advanced hepatic metastasis and peritoneal carcinomatosis after resection of remnant gastric cancer resection 3 mo ago. The patient only received epidermal growth factor (EGF...We report a 55-year-old male who developed advanced hepatic metastasis and peritoneal carcinomatosis after resection of remnant gastric cancer resection 3 mo ago. The patient only received epidermal growth factor (EGF) receptor antibody (Cetuximab) plus recombinant human endostatin (Endostar). Anti-tumor activity was assessed by 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computer tomography (PET/CT) at baseline and then every 4 wk. The case illustrates that 18FDG-PET/CT could make an early prediction of the response to Cetuximab plus Endostar in such clinical situations. 18FDG-PET/CT is a useful molecular imaging modality to evaluate the biological response advanced hepatic metastasis and peritoneal carcinomatosis to Cetuximab plus Endostar in patients after remnant gastric cancer resection.展开更多
As one of the oldest creatures on the earth, the tortoises have formed a nearly perfect shell structure after millions of years of evolution In this paper, Chinese tortoise shell is studied. Firstly, the scanni...As one of the oldest creatures on the earth, the tortoises have formed a nearly perfect shell structure after millions of years of evolution In this paper, Chinese tortoise shell is studied. Firstly, the scanning model of the tortoise shell is established by means of computer tomography (CT) scanning technology and MIMICS software. Secondly, the solid model of three-dimensional structure of the tortoise shell is constructed by using geomagic studio reverse engineering software. Afterwards, the compression numerical simulation of the tortoise shell structure under low strain rate is conducted with the help of finite element software LS-DYNA. Finally, load-bearing characteristics of the tortoise shell structure and dome-shaped structure are compared and analyzed. The results show that compared withthe dome-shaped structure with the same volume, tortoise shell structure has a higher structural rigidity and can withstand higher pressure. Therefore, tortoise shell structure provide some reference to the design of armored vehicles, sheltersand other types of thin shell structures.展开更多
The transcatheter aortic valve implantation (TAVI) consist an altemative treatment in patients with severe aortic stenosis. Multimodality imaging using transthoracic echocardiography (TTE) or transesophageal echoc...The transcatheter aortic valve implantation (TAVI) consist an altemative treatment in patients with severe aortic stenosis. Multimodality imaging using transthoracic echocardiography (TTE) or transesophageal echocardiography (TOE) and multislice CT (MSCT) constitute cornerstone techniques for the pre-operative management, peri-procedural guidance, follow up and recognition of possible transcatheter valve related complications. CT angiography is much more accurate regarding the total definition of aortic annulus diameter and circumferential area. Two-dimensional (2D) echocardiography, underestimates the aortic valve annulus diameter compared to 3D imaging techniques (MSCT, MRI and 3D TOE). Three-dimensional TOE imaging provides measurements of the aortic valve annulus similar to those delivered by MSCT. The pre-procedural MSCT constitutes the gold standard modality minimizing the presence of paravalvular aortic regurgitation, one of the most frequent complications. TOE/TTE and MSCT performance could predict the possibility of pacemaker implantation post-procedural. The presence of a new transient or persisting MR can be assessed well by TOE. Both TTE and TOE, consist initially the basic examination for post TAVI evaluation. In case of transcatheter heart valve failure, the MSCT could be used as additional imaging technique.展开更多
文摘BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis.
文摘BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMARY We describe the case of a 34-year-old male,who underwent both MDC and MRI examinations of the upper abdomen because of liver cirrhosis.MDCT and MRI angiography images of the upper abdomen revealed an anatomic variation of the superior mesenteric vein(SMV),the double SMVs.CONCLUSION The double SMVs are a congenital abnormality without potential clinical manifestation.Physicians need to be aware of this anatomical variation during abdominal surgery to avoid iatrogenic injury.
基金The Scholarship Supported by Ministry of Education of China for Research Abroad(No.3037[2006])the Excellent Doctoral Dissertation Foundation of Southeast University (No.YBTJ-0512)the National Basic Research Program of China(973Program)(No.2009CB623203)
文摘In order to investigate the effects of two mineral admixtures (i. e., fly ash and ground slag)on initial defects existing in concrete microstructures, a high-resolution X-ray micro-CT( micro-focus computer tomography)is employed to quantitatively analyze the initial defects in four series of highperformance concrete (HPC)specimens with additions of different mineral admixtures. The nigh-resolution 3D images of microstructures and filtered defects are reconstructed by micro- CT software. The size distribution and volume fractions of initial defects are analyzed based on 3D and 2D micro-CT images. The analysis results are verified by experimental results of watersuction tests. The results show that the additions of mineral admixtures in concrete as cementitious materials greatly change the geometrical properties of the microstructures and the spatial features of defects by physical-chemistry actions of these mineral admixtures. This is the major cause of the differences between the mechanical behaviors of HPC with and without mineral admixtures when the water-to-binder ratio and the size distribution of aggregates are constant.
文摘Hepatocellular carcinoma (HCC) is one of the most common primary cancers in the world. Surgery is the gold standard for treatment of patients with HCC. Recurrence and metastasis are the major obstacles to further improve the prognosis of HCC. Most recurrences are intrahepatic. However, 30% of the recurrences are extrahepatic. The role of resection in intrahepatic recurrences is widely accepted. The role of resection in extrahepatic HCC recurrence and metastasis is not well established. 18F fluorodeoxyglucose (18F-FDG) positron emission tomography/computer tomography (PET/CT) is useful in detecting distant metastasis from a variety of malignancies and shows superior accuracy to conventional imaging modalities in identification of intrahepatic and extrahepatic metastasis. We present one patient with one new isolated omental lymph node metastasis, who had a history of huge HCC resected six years ago. The metastatic focus was identified with 18 F-FDG PET/CT and resected. The follow-up revealed good prognosis with a long-term survival potential after resection of the omental lymphatic metastasis.
文摘AIM: To assess the ability of ^18F-fluorodeoxyglucose positron emission tomography/computer tomography (^18F-FDG PET/CT) to differentiate between benign and malignant portal vein thrombosis in hepatocellular carcinoma (HCC) patients.METHODS: Five consecutive patients who had HBV cirrhosis, biopsy-proven HCC, and thrombosis of the main portal vein and/or left/right portal vein on ultrasound (US), computer tomography (CT) or magnetic resonance imaging (MRI) were studied with ^18F-FDG PET/CT. The presence or absence of a highly metabolic thrombus on ^18F-FDG PET/CT was considered diagnostic for malignant or benign portal vein thrombosis, respectively. All patients were followed-up monthly with US, CT or MRI. Shrinkage of the thrombus or recanalization of the vessels on US, CT or MRI during follow-up was considered to be definitive evidence of the benign nature of the thrombosis, whereas enlargement of the thrombus, disruption of the vessel wall, and parenchymal infiltration over follow-up were considered to be consistent with malignancy. ^18SF-FDG PET/CT, and US, CT or MRI results were compared.RESULTS: Follow-up (1 to 10 mo) showed signs of malignant thrombosis in 4 of the 5 patients. US, CT or MRI produced a true-positive result for malignancy in 4 of the patients, and a false-positive result in 1. ^18F-FDG PET/CT showed a highly metabolic thrombus in 4 of the 5 patients. ^18F-FDG PET/CT achieved a true-positive result in all 4 of these patients, and a true-negative result in the other patient. No false-positive result was observed using ^18F-FDG PET/CT.CONCLUSION: ^18F-FDG PET/CT may be helpful in discriminating between benign and malignant portal vein thrombi. Patients may benefit from ^18F-FDG PET/CT when portal vein thrombi can not be diagnosed exactly by US, CT or MRI.
文摘AIMTo measure optic nerve sheath diameters (ONSD) in different locations by computer tomography (CT) and to recommend the best location for cases when ONSD is used for intracranial pressure monitoring.METHODSIn a prospective cohort study, CT data of 300 healthy adults were analyzed (600 eyes). In all cases, the CT investigation was performed at the Emergency Department because of the various conditions that proved not to be connected with ophthalmological or neurological pathology. The ONSD were measured at 3 mm and 8 mm distance from the globe, and 3 mm from the anterior opening of the optic canal. The correlation analysis was performed with gender, age, and ethnic background.RESULTSThe right/left ONSD are 4.94±1.51/5.17±1.34 mm at 3 mm, 4.35±0.76/4.45±0.62 mm at 8 mm from the globe, and 3.55±0.82/3.65±0.7 mm at 3 mm from the optic canal. No significant differences correlated with gender of the patients, their age, and ethnic background were found.CONCLUSIONIn healthy persons, the ONSD varies from 5.17±1.34 mm to 3.55±0.82 mm in different locations within the intraorbital space. The most stable results with lesser standard deviation can be obtained if it is measured 8-10 mm from the globe.
基金supported by a Grant-in-Aid for the Strategy Technology Development Programs from the Korea Ministry of Knowledge Economy (No.10035474)
文摘Pistons used in automobile engines are made of aluminum alloy; and endurance of high pressure and high temperature is required. Recently, high strength pistons are needed to cope with the increase of pressure and temperature in the engine cylinder. A high strength piston is possible when the piston casting has little or no casting defects, such as micro-pores and cracks. Generally the defects can be evaluated by non-destructive testing (NDT), and the most efficient ways for evaluation are using ultrasonics and computer tomography. In the present study, two NDT methods were compared and evaluated to investigate the defects in the aluminum piston castings. Artificial defects were machined by using very small drill bits with diameters 1, 0.5, 0.3, 0.2 and 0.1 mm. The defects were investigated by using an ultrasonic tester and a computer tomography system. Defects smaller than 0.3 mm may not be found by using the ultrasonic test, but the defects may be found by using the computer tomography system. The investigation conditions for detecting small defects and the scanning time for in-line defect analysis are discussed in the present study.
基金Supported by National Natural Science Foundation of China,No.H0306/81100254.
文摘BACKGROUND Esophagojejunal anastomotic leakage(EJAL)is a serious and potentially crucial complication of total gastrectomy and represents the major cause of postoperative death,with a mortality rate of up to 50%.However,treatment remains challenging and controversial.We report here the case of a patient whose intrathoracic EJAL was successfully treated with computer tomography(CT)-guided negative pressure drainage treatment.CASE SUMMARY A 69-year-old male patient complained of difficulty swallowing within the last six months.He was diagnosed with esophagogastric junction carcinoma,Siewert II,cT3N0M0 stage II.Total gastrectomy and Roux-en-Y esophagojejunostomy were performed.High fever,left chest pain and dyspnea appeared on postoperative day 5,and EJAL was confirmed by CT,gastroscopy and oral blue-dimethylene tests.Conservative treatment measures were applied immediately,including antibiotics,nasojejunal tubes,and repeated thoracic puncture and drainage under ultrasound guidance.However,without sufficient and effective drainage,the thoracic infection and systemic condition continued to deteriorate.With the cooperation of multiple departments,percutaneous CT-guided drainage(24 Fr 7 mm)in the thoracic cavity was successfully placed near the anastomotic leakage.Because of continuous negative pressure suction,the infection symptoms were effectively controlled and the general situation gradually recovered.Subsequent follow-up examination showed that the patient was in good condition.CONCLUSION Negative pressure drainage via CT may represent an effective minimally invasive approach to treating intrathoracic EJAL.
文摘BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE). OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations. DESIGN : Contrast observation SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College. PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHOOS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM. TCD and CT examinations. RESULTS: All the 416 infant patients with HIE participated in the result analysis. (1) Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0% (22/130 ),x^2=41.66 ;29.2% ( 38/130 ) vs. 6.2% ( 8/130 ), x^2=23.77, P 〈 0.01 ], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. (2) Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8% (178/196),78.6% (154/196),x^2=4.32,P 〈 0.05;64.3% (126/196),43.9% (86/196) ,x^2=16.44 ;44.9% (88/196) ,22.4% (44/196),x^2=22.11 ;21.4% (42/196), 10.2% (20/196),x^2=9.27, P 〈 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24^th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1^st month after birth, and all the patients recovered to the normal in the 3^rd month after birth, while CT examination showed that mild abnormality still existed in the 24^th month after birth (1.0% ,2/196). (3) Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1^st, 3^rd, 6^th and 12^th months after birth[86.7% (78/90),44.4% (40/90),x^2=35.53;62.2% (56/90),31.1% (28/90),x^2=17.51 ;37.8% (34/90),6.7% (6/90), x^2=27.14, P 〈 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24^th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3^rd month after birth, and all the infant patients recovered in the 6^th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12^th month after birth, and all of infant patients recovered to the normal in the 24^th month after birth.CONCLUSION : BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination.
文摘Background The diagnosis of Parkinson’s disease is presently based on non-specific symptoms. However, radionuclide dopamine transporters imaging can provide specific diagnostic tool for Parkinson’s disease. This study was designed to investigate the effects of imaging of dopamine transporters with 99mTc-TRODAT-1 in early diagnosis or differential diagnosis of Parkinson’s disease.Methods Nine normal monkeys were used to establish N-methyl-4-phenyl-1, 2, 3, 6-tetra-hydropyridine (MPTP) hemi-Parkinsonian animal models, and they were subjected to imaging. Twenty-nine patients with Parkinson’s disease, 12 age-matched healthy volunteers, and 18 age-matched patients with Parkinson’s syndrome were investigated. Single photon emission computer tomography (SPECT) was performed 3 hours after intravenous injection of 740 MBq 99mTc-TRODAT-1. Striatum specific uptake of 99mTc-TRODAT-1 was calculated according to the ratio of striatum (ST) to cerebellum (CB)in dopamine transporters uptake.Results In normal monkeys, bilateral ratio of ST/CB was 2.34±0.41. After the injection of MPTP, uptake rate of 99mTc-TRODAT-1 at damaged region was much lower than that at the contralateral region, resulting in a significant difference in the ratio of ST/CB (right: ST/CB=1.73±0.35; left: ST/CB=1.90±0.30), especially in hemi-Parkinsonian model monkeys (right: ST/CB=1.29±0.17; left: ST/CB=1.80±0.33). The ratios of ST/CB were 1.57±0.17 and 1.61±0.14 for the right and left respectively in the healthy volunteers, 1.04±0.29 and 1.06±0.30 in the age-matched patients with Parkinson’s disease, and 1.56±0.17 and 1.59±0.18 in the age-matched patients with Parkinson’s disease syndrome. A significant difference was noted between group of Parkinson’s disease, normal controls and Parkinson’s disease syndrome. Conclusion The results suggest that 99mTc-TRODAT-1 dopamine transporters SPECT has clinical application value in early diagnosis or differential diagnosis of Parkinson’s disease.
文摘BACKGROUND The level of Ki-67 expression has served as a prognostic factor in gastric cancer.The quantitative parameters based on the novel dual-layer spectral detector computed tomography(DLSDCT)in discriminating the Ki-67 expression status are unclear.AIM To investigate the diagnostic ability of DLSDCT-derived parameters for Ki-67 expression status in gastric carcinoma(GC).METHODS Dual-phase enhanced abdominal DLSDCT was performed preoperatively in 108 patients with gastric adenocarcinoma.Primary tumor monoenergetic CT attenuation value at 40-100 kilo electron volt(kev),the slope of the spectral curve(λ_(HU)),iodine concentration(IC),normalized IC(nIC),effective atomic number(Z^(eff))and normalized Z^(eff)(nZ^(eff))in the arterial phase(AP)and venous phase(VP)were retrospectively compared between patients with low and high Ki-67 expression in gastric adenocarcinoma.Spearman’s correlation coefficient was used to analyze the association between the above parameters and Ki-67 expression status.Receiver operating characteristic(ROC)curve analysis was performed to compare the diagnostic efficacy of the statistically significant parameters between two groups.RESULTS Thirty-seven and 71 patients were classified as having low and high Ki-67 expression,respectively.CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),and Z^(eff)-related parameters were significantly higher,but IC-related parameters were lower in the group with low Ki-67 expression status than the group with high Ki-67 expression status,and other analyzed parameters showed no statistical difference between the two groups.Spearman’s correlation analysis showed that CT_(40 kev-VP),CT_(70 kev-VP),CT_(100 kev-VP),Z^(eff),and n Z^(eff) exhibited a negative correlation with Ki-67 status,whereas IC and nIC had positive correlation with Ki-67 status.The ROC analysis demonstrated that the multi-variable model of spectral parameters performed well in identifying the Ki-67 status[area under the curve(AUC)=0.967;sensitivity 95.77%;specificity 91.89%)].Nevertheless,the differentiating capabilities of singlevariable model were moderate(AUC value 0.630-0.835).In addition,the nZ_(VP)^(eff) and nIC_(VP)(AUC 0.835 and 0.805)showed better performance than CT_(40 kev-VP),CT_(70 kev-VP) and CT_(100 kev-VP)(AUC 0.630,0.631 and 0.662)in discriminating the Ki-67 status.CONCLUSION Quantitative spectral parameters are feasible to distinguish low and high Ki-67 expression in gastric adenocarcinoma.Z^(eff) and IC may be useful parameters for evaluating the Ki-67 expression.
文摘Cystic lesions of the anterior mediastinum in children suggest a well-known group of benign lesions that are comparatively frequent.Thymic cysts(TCs)are mostly positioned in the anterior mediastinum and some patients in the neck.Benign TCs classified as congenital intra-thoracic mesothelial cysts are commonly asymptomatic and have slight clinical significance.Multilocular TC,which can mimic another anterior mediastinal cystic tumor and is seen in adults,is more clinically important.It is a sporadic mediastinal lesion thought to arise in the course of acquired inflammation.Congenital mediastinal cysts represent 3%-6%of all mediastinal tumors and 10%-18%of radiologically reported mediastinal masses.Mediastinal TCs are uncommon and it is hard to know their true incidence.About 60%of cases with mediastinal TCs are asymptomatic,and the remainder of patients complains of nonspecific symptoms(e.g.,chest pain,dyspnea,or cough).The literature suggests that most cysts are benign,but an indefinite percentage may have a neoplastic process and result in significant compressive symptoms over time.Clinical symptoms of TCs vary depending on the location.In addition,frequent symptoms at the appearance of enlarged benign thymic and mediastinal cysts generally contain compressive symptoms(e.g.,respiratory distress,thymic pain,and symptoms related to Horner syndrome,hoarseness,dysphonia,dyspnea,orthopnea,wheezing,and fever).Many TCs have cystic density and a neat border and are simple to diagnose with radiological imaging.However,some TCs are hard to identify before surgery and may be misidentified as thymomas depending on their site and computed tomography results.Excision by thoracotomy,median sternotomy,or video-assisted techniques is essential for conclusive diagnosis,management,and abolition of relapse of anterior mediastinal masses and TCs.Histopathologic examination may be required after surgery.Considering the extent of the mass and the preliminary inability to make a definitive diagnosis,en bloc excision of the cyst was thought to be preferred to circumvent likely complications(e.g.,perforation,spillage of the contents,or incomplete excision).
文摘Hemopericardium is a common finding at autopsy, but it may represent a challenge for the forensic pathologist when the etiopathologi-cal relationship in causing death is requested. Hemopericardium and cardiac tamponade can be evaluated in living people using radiological techniques, in particular computer tomography (CT). Only a few studies are reported in literature involving post-mortem (PM) cases, where PMCT imaging has been used in order to investigate acute hemopericardium, and they have shown a good accuracy of this technique. Here we report a case involving a 70-year-old white male found dead on the beach, with a medical history of hepatitis C and chronic hypertension with a poor pharmacological response. A PMCT was performed about 3 h after the discovery of the body. The PMCT examination showed an intrapericardial aortic dissection associated to a periaortic hematoma, a sickle-shaped intramural hematoma, a false lumen, and a hemop-ericardium consisting in fluid and clotted blood. In this case, the PMCT was able to identify the cause of death, even though a traditional autopsy was required to confirm the radiological findings. PMCT is a reliable technique, which in chosen cases, can be performed without the need for a traditional autopsy to be carried out.
文摘BACKGROUND Lupus mesenteric vasculitis(LMV)is a serious condition that may occur as an acute manifestation of gastrointestinal(GI)involvement and is not easily diagnosed by physicians.Delayed diagnosis and treatment of LMV may lead to rapid disease progression and can be life threatening.CASE SUMMARY A previously healthy 27-year-old woman presented with abdominal pain following a history of fatigue and consumption of cold water.Laboratory invest-igations,physical examinations,and enhanced abdominal computed tomography(CT)suggested systemic lupus erythematosus complicated by LMV.She received treatments,such as GI decompression,somatostatin,glucocorticoids,and immu-nosuppressants,and was evaluated using color ultrasonography.Twenty days later,the patient reported no stomach discomfort and was able to consume semi-liquid food.Laboratory investigations showed that inflammatory factors decreased to normal levels and complement levels increased slightly.One year after discharged,she recovered with methylprednisolone being tapered to 4 mg per day,mycophenolate mofetil to 0.75 g bid,and hydroxychloroquine to 0.2 g bid;however,only C3 complement level was slightly below the normal level.CONCLUSION Early diagnosis of LMV is essential for successful treatment;this depends on a combination of clinical manifestations,laboratory investigations,and imaging findings.Enhanced CT is preferred,but ultrasonography can be used for prompt screening and follow-up.
基金the Australian Coal Industry's Research Program(ACARP)-Grant Number C29073.
文摘One factor that limits development of fundamental research on the infuence of coke microstructure on its strength is the difculty in quantifying the way that microstructure is both classifed and distributed in three dimensions.To support such fundamental studies,this study evaluated a novel volumetric approach for classifying small(approx.450μm^(3))blocks of coke microstructure from 3D computed tomography scans.An automated process for classifying microstructure blocks was described.It is based on Landmark Multi-Dimensional Scaling and uses the Bhattacharyya metric and k-means clustering.The approach was evaluated using 27 coke samples across a range of coke with diferent properties and reliably identifed 6 ordered class of coke microstructure based on the distribution of voxel intensities associated with structural density.The lower class(1–2)subblocks tend to be dominated by pores and thin walls.Typically,there is an increase in wall thickness and reduced pore sizes in the higher classes.Inert features are also likely to be seen in higher classes(5–6).In general,this approach provides an efcient automated means for identifying the 3D spatial distribution of microstructure in CT scans of coke.
文摘Medical Image Fusion is the synthesizing technology for fusing multi-modal medical information using mathematical procedures to generate better visual on the image content and high-quality image output.Medical image fusion represents an indispensible role infixing major solutions for the complicated medical predicaments,while the recent research results have an enhanced affinity towards the preservation of medical image details,leaving color distortion and halo artifacts to remain unaddressed.This paper proposes a novel method of fusing Computer Tomography(CT)and Magnetic Resonance Imaging(MRI)using a hybrid model of Non Sub-sampled Contourlet Transform(NSCT)and Joint Sparse Representation(JSR).This model gratifies the need for precise integration of medical images of different modalities,which is an essential requirement in the diagnosing process towards clinical activities and treating the patients accordingly.In the proposed model,the medical image is decomposed using NSCT which is an efficient shift variant decomposition transformation method.JSR is exercised to extricate the common features of the medical image for the fusion process.The performance analysis of the proposed system proves that the proposed image fusion technique for medical image fusion is more efficient,provides better results,and a high level of distinctness by integrating the advantages of complementary images.The comparative analysis proves that the proposed technique exhibits better-quality than the existing medical image fusion practices.
文摘Colorectal cancer (CRC) remains a leading cancer killer worldwide. But the disease is both curable and preventable at an early stage. Regular CRC cancer screening has been shown to reduce the risk of dying from CRC. However, the importance of large-scale screening is only now starting to be appreciated. This article reviews a variety of imaging procedures available for detecting ulcerative colitis (UC) and Crohn's disease (CD), polyps and CRC in their early stage and also presents details on various screening options. Detecting, staging and re-staging of patients with CRC also require multimodality, multistep imaging approaches. Staging and re-staging with conventional colonoscopy (CC), computer tomography colonography (CTC), magnetic resonance colonography (MRC) and positron emission tomography/computer tomography colonography (PET/CTC) are of paramount importance in determining the most appropriate therapeutic method and in predicting the risk of tumor recurrence and overall prognosis. The advantages and limitations of these modalities are also discussed.
文摘We report a 55-year-old male who developed advanced hepatic metastasis and peritoneal carcinomatosis after resection of remnant gastric cancer resection 3 mo ago. The patient only received epidermal growth factor (EGF) receptor antibody (Cetuximab) plus recombinant human endostatin (Endostar). Anti-tumor activity was assessed by 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computer tomography (PET/CT) at baseline and then every 4 wk. The case illustrates that 18FDG-PET/CT could make an early prediction of the response to Cetuximab plus Endostar in such clinical situations. 18FDG-PET/CT is a useful molecular imaging modality to evaluate the biological response advanced hepatic metastasis and peritoneal carcinomatosis to Cetuximab plus Endostar in patients after remnant gastric cancer resection.
文摘As one of the oldest creatures on the earth, the tortoises have formed a nearly perfect shell structure after millions of years of evolution In this paper, Chinese tortoise shell is studied. Firstly, the scanning model of the tortoise shell is established by means of computer tomography (CT) scanning technology and MIMICS software. Secondly, the solid model of three-dimensional structure of the tortoise shell is constructed by using geomagic studio reverse engineering software. Afterwards, the compression numerical simulation of the tortoise shell structure under low strain rate is conducted with the help of finite element software LS-DYNA. Finally, load-bearing characteristics of the tortoise shell structure and dome-shaped structure are compared and analyzed. The results show that compared withthe dome-shaped structure with the same volume, tortoise shell structure has a higher structural rigidity and can withstand higher pressure. Therefore, tortoise shell structure provide some reference to the design of armored vehicles, sheltersand other types of thin shell structures.
文摘The transcatheter aortic valve implantation (TAVI) consist an altemative treatment in patients with severe aortic stenosis. Multimodality imaging using transthoracic echocardiography (TTE) or transesophageal echocardiography (TOE) and multislice CT (MSCT) constitute cornerstone techniques for the pre-operative management, peri-procedural guidance, follow up and recognition of possible transcatheter valve related complications. CT angiography is much more accurate regarding the total definition of aortic annulus diameter and circumferential area. Two-dimensional (2D) echocardiography, underestimates the aortic valve annulus diameter compared to 3D imaging techniques (MSCT, MRI and 3D TOE). Three-dimensional TOE imaging provides measurements of the aortic valve annulus similar to those delivered by MSCT. The pre-procedural MSCT constitutes the gold standard modality minimizing the presence of paravalvular aortic regurgitation, one of the most frequent complications. TOE/TTE and MSCT performance could predict the possibility of pacemaker implantation post-procedural. The presence of a new transient or persisting MR can be assessed well by TOE. Both TTE and TOE, consist initially the basic examination for post TAVI evaluation. In case of transcatheter heart valve failure, the MSCT could be used as additional imaging technique.