期刊文献+
共找到4,375篇文章
< 1 2 219 >
每页显示 20 50 100
Computerized tomography-guided therapeutic percutaneous puncture catheter drainage-combined with somatostatin for severe acute pancreatitis: An analysis of efficacy and safety 被引量:1
1
作者 Xue-Lan Zheng Wan-Ling Li +1 位作者 Yan-Ping Lin Ting-Long Huang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期59-66,共8页
BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to impr... BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to improve treatment efficacy.AIM To evaluate the efficacy and safety of computerized tomography-guided the-rapeutic percutaneous puncture catheter drainage(CT-TPPCD)combined with somatostatin(SS)in the treatment of SAP.METHODS Forty-two SAP patients admitted to The Second Affiliated Hospital of Fujian Medical University from June 2020 to June 2023 were selected.On the basis of routine treatment,20 patients received SS therapy(control group)and 22 patients were given CT-TPPCD plus SS intervention(research group).The efficacy,safety(pancreatic fistula,intra-abdominal hemorrhage,sepsis,and organ dysfunction syndrome),abdominal bloating and pain relief time,bowel recovery time,hospital stay,inflammatory indicators(C-reactive protein,interleukin-6,and pro-calcitonin),and Acute Physiology and Chronic Health Evaluation(APACHE)II score of both groups were evaluated for comparison.RESULTS Compared with the control group,the research group had a markedly higher total effective rate,faster abdominal bloating and pain relief and bowel recovery,INTRODUCTION Pancreatitis,an inflammatory disease occurring in the pancreatic tissue,is classified as either acute or chronic and is associated with high morbidity and mortality,imposing a socioeconomic burden[1,2].The pathogenesis of this disease involves early protease activation,activation of nuclear factor kappa-B-related inflammatory reactions,and infiltration of immune cells[3].Severe acute pancreatitis(SAP)is a serious condition involving systemic injury and subsequent possible organ failure,accounting for 20%of all acute pancreatitis cases[4].SAP is also characterized by rapid onset,critical illness and unsatisfactory prognosis and is correlated with serious adverse events such as systemic inflammatory response syn-drome and acute lung injury,threatening the health of patients[5,6].Therefore,timely and effective therapeutic inter-ventions are of great significance for improving patient prognosis and ensuring therapeutic effects.Somatostatin(SS),a peptide hormone that can be secreted by endocrine cells and the central nervous system,is in-volved in the regulatory mechanism of glucagon and insulin synthesis in the pancreas[7].It has complex and pleiotropic effects on the gastrointestinal tract,which can inhibit the release of gastrointestinal hormones and negatively modulate the exocrine function of the stomach,pancreas and bile,while exerting a certain influence on the absorption of the di-gestive system[8,9].SS has shown certain clinical effectiveness when applied to SAP patients and can regulate the severity of SAP and immune inflammatory responses,and this regulation is related to its influence on leukocyte apoptosis and adhesion[10,11].Computerized tomography-guided therapeutic percutaneous puncture catheter drainage(CT-TPPCD)is a surgical procedure to collect lesion fluid and pus samples from necrotic lesions and perform puncture and drainage by means of CT image examination and precise positioning[12].In the research of Liu et al[13],CT-TPPCD applied to pa-tients undergoing pancreatic surgery contributes to not only good curative effects but also a low surgical risk.Baudin et al[14]also reported that CT-TPPCD has a clinical success rate of 64.6%in patients with acute infectious necrotizing pan-creatitis,with nonfatal surgery-related complications found in only two cases,suggesting that this procedure is clinically effective and safe in the treatment of the disease.In light of the limited studies on the efficacy and safety of SS plus CT-TPPCD in SAP treatment,this study performed a relevant analysis to improve clinical outcomes in SAP patients. 展开更多
关键词 computerized tomography guidance Therapeutic percutaneous puncture catheter drainage SOMATOSTATIN Severe acute pancreatitis Efficacy and safety
下载PDF
Study on sex differences and potential clinical value of threedimensional computerized tomography pelvimetry in rectal cancer patients
2
作者 Xiao-Cong Zhou Fei-Yue Ke +2 位作者 Gaurav Dhamija Hao Chen Qiang Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第3期773-786,共14页
BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampe... BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampers the establishment of consistent conclusions.AIM To comprehensively assess 16 pelvic and 7 soft tissue parameters through computerized tomography(CT)-based three-dimensional(3D)reconstruction,providing a strong theoretical basis to address challenges in laparoscopic rectal cancer radical surgery.METHODS We analyzed data from 218 patients who underwent radical laparoscopic surgery for rectal cancer,and utilized CT data for 3D pelvic reconstruction.Specific anatomical points were carefully marked and measured using advanced 3D modeling software.To analyze the pelvic and soft tissue parameters,we emp-loyed statistical methods including paired sample t-tests,Wilcoxon rank-sum tests,and correlation analysis.RESULTS The investigation highlighted significant sex disparities in 14 pelvic bone parameters and 3 soft tissue parameters.Males demonstrated larger measurements in pelvic depth and overall curvature,smaller measurements in pelvic width,a larger mesorectal fat area,and a larger anterior-posterior abdominal diameter.By contrast,females exhibited wider pelvises,shallower depth,smaller overall curvature,and an increased amount of subcutaneous fat tissue.However,there were no significant sex differences observed in certain parameters such as sacral curvature height,superior pubococcygeal diameter,rectal area,visceral fat area,waist circumference,and transverse abdominal diameter.CONCLUSION The reconstruction of 3D CT data enabled accurate pelvic measurements,revealing significant sex differences in both pelvic and soft tissue parameters.This study design offer potential in predicting surgical difficulties and creating personalized surgical plans for male rectal cancer patients with a potentially“difficult pelvis”,ultimately improving surgical outcomes.Further research and utilization of these parameters could lead to enhanced surgical methods and patient care in laparoscopic rectal cancer radical surgery. 展开更多
关键词 computerized tomography Rectal cancer Three-dimensional reconstruction PELVIMETRY Sex differences
下载PDF
Detection of tracheal branching with computerized tomography:The relationship between the angles and age-gender
3
作者 Şevket Kahraman Mesut Furkan Yazar +2 位作者 Hüseyin Aydemir Mecit Kantarci Sonay Aydin 《World Journal of Radiology》 2023年第4期118-126,共9页
BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physi... BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physiology.AIM To determine the tracheobronchial branching angles in pediatric and adult populations by using the multislice computed tomography(CT)and minimum intensity projection(MinIP)technique,which is a non-invasive method.METHODS Our study was carried out retrospectively.Patients who underwent contrast and non-contrast CT examination,whose anatomically and pathophysiologically good tracheobronchial system and lung parenchyma images were obtained,were included in the study.Measurements were made in the coronal plane of the lung parenchyma.In the coronal plane,right main bronchus-left main bronchus angle,right upper lobe bronchus-intermedius bronchus angle,right middle lobe bronchus-right lower lobe bronchus angle,left upper lobe bronchus-left lower lobe bronchus angle were measured.RESULTS The study population consisted of 1511 patients,753 pediatric(mean age:13.4±4.3;range:1-18 years)and 758 adults(mean age:54.3±17.3;range:19-94 years).In our study,tracheal bifurcation angle was found to be 73.3°±13.7°(59.6°-87°)in the whole population.In the pediatric group,the right-left main coronal level was found to be higher in boys compared to girls(74.6°±12.9°vs 71.2°±13.9°,P=0.001).In the adult group,the right-left main coronal level was found to be lower in males compared to females(71.9°±12.9°vs 75.8°±14.7°,P<0.001).CONCLUSIONS Our study,with the number of 1511 patients,is the first study in the literature with the largest number of patient populations including pediatric and adult demographic data,measuring the angle values of the tracheobronchial system using multislice CT and MinIP technique.Study data will not only be a guide during invasive procedures,but it can also guide studies to be done with imaging methods. 展开更多
关键词 Tracheobronchial branching angles Subcarinal angle Multislice computerized tomography Minimum intensity projection technique
下载PDF
A machine learning-based strategy for predicting the mechanical strength of coral reef limestone using X-ray computed tomography
4
作者 Kai Wu Qingshan Meng +4 位作者 Ruoxin Li Le Luo Qin Ke ChiWang Chenghao Ma 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第7期2790-2800,共11页
Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL... Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL. 展开更多
关键词 Coral reef limestone(CRL) Machine learning Pore tensor X-ray computed tomography(ct)
下载PDF
Application of Proton Magnetic Resonance Spectroscopy and Computerized Tomography in the Diagnosis and Treatment of Nonalcoholic Fatty Liver Disease 被引量:4
5
作者 王南 董慧 +1 位作者 魏世超 陆付耳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期295-298,共4页
In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluati... In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluation of therapeutic effects, 22 patients with NAFLD were selected according to the Chinese Medical Association's (CMA) standard of the NAFLD in comparison with 20 healthy volunteers (as control group). Blood samples for biochemistry were collected. The severity of hepatosteatosis was evaluated by ^1H-MRS scan and CT scan of liver. The intrahepatic content of lipid (IHCL) and CT value ratio of liver to spleen were calculated. The patients in NAFLD group were treated with Ganzhixiao Capsule for 8 weeks. The changes in IHCL and CT value ratio of liver to spleen were observed before and after treatment. In NAFLD group serum ALT, TG, IHCL calculated by ^1HMRS were increased and CT value ratio of liver to spleen decreased significantly as compared with control group. After treatment for 8 weeks serum ALT, TG, IHCL were decreased significantly, while CT value ratio of liver to spleen increased significantly in NAFLD group. It was suggested that IHCL could be measured precisely by ^1HMRS. NAFLD was treated effectively by Ganzhixiao capsule. 展开更多
关键词 proton magnetic resonance spectroscopy computerized tomography nonalcoholic fatty liver disease
下载PDF
Pore structure of ore granular media by computerized tomography image processing 被引量:6
6
作者 吴爱祥 杨保华 +1 位作者 习泳 江怀春 《Journal of Central South University of Technology》 EI 2007年第2期220-224,共5页
The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the ... The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%. 展开更多
关键词 ore granular media pore structure X-ray computerized tomography image processing
下载PDF
Effects of Irregular Respiratory Motion on the Positioning Accuracy of Moving Target with Free Breathing Cone-Beam Computerized Tomography 被引量:1
7
作者 Xiang Li Tianfang Li +9 位作者 Ellen Yorke Gig Mageras Xiaoli Tang Maria Chan Weijun Xiong Marsha Reyngold Richard Gewanter Abraham Wu John Cuaron Margie Hunt 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第2期173-183,共11页
For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT ... For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8 mm, 2.4 ± 2.1 mm, and 3.8 ± 2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5 ± 1.1 mm, 0.3 ± 0.8 mm, and 1.8 ± 2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets. 展开更多
关键词 CONE Beam computerized tomography RESPIRATORY Motion Effect
下载PDF
The Differences of Interstitial Lung Diseases in High-Resolution Computerized Tomography and Pulmonary Function Test among Different Connective Tissue Diseases, and the Correlated Factors 被引量:1
8
作者 Zhen Jiang Wenyou Pan +1 位作者 Jinhui Tao Xiangpei Li 《Open Journal of Rheumatology and Autoimmune Diseases》 2018年第2期53-65,共13页
Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients w... Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients with different CTDs were recruited and underwent lung HRCT and PFT. Eerythrocyte sedimentation rate (ESR), C-reactive protein (CRP), serum ferritin (SF), anti-SSA, and so on were tested. Based on HRCT, a patient was classified into ILD group (CTD+ILD) or non-ILD group (CTD-ILD). HRCT, PFT, and laboratory markers were compared according to CTDs and CTD-associated ILDs. Results. The incidences of ILD were 79.6%, 82.0%, 89.7%, and 97.1% respectively for Rheumatoid arthritis (RA), primary Sjogren’s symptom (pSS), dermatomyositis/polymyositis (DM/PM), and systemic sclerosis (SSc) groups. RA and pSS patients exhibited more nodules, patching, ground-glass opacity, and cord shadow foci in HRCT, DM/PM and SSc patients exhibited more reticular opacity and honeycombing foci. RA and pSS patients exhibited more obstructive ventilatory disorder, small airway dysfunction and emphysema in PFT, and DM/PM and SSc patients exhibited more restrictive ventilatory disorder, mixed ventilatory disorder. ESR, CRP and SF were significantly higher in total CTD+ILD group than in total CTD-ILD group (P = 0.047, 0.006, 0.004, respectively), and higher in different CTD+ ILD groups than in comparable CTD-ILD groups (P = 0.049, 0.048, and 0.023, pSS+ILD, SSc+ILD and RA+ILD compared to pSS-ILD, SSc-ILD and RA-ILD, respectively for ESR, CRP, SF). The positive rate of anti-SSA was significantly higher in DM/PM+ILD group than in DM/PM-ILD group (P = 0.025). Conclusions. The manifestations and incidences of ILDs differ among different CTDs in HRCT and PFT, and inflammation and anti-SSA are positively correlated with ILDs in different CTDs, which provide important evidences for judging disease condition and prognosis. 展开更多
关键词 CONNEctIVE Tissue Diseases INTERSTITIAL lung Disease HIGH-RESOLUTION computerized tomography PULMONARY Function Test Inflammation
下载PDF
The possible value of ~18F-FDG positron emission tomography/computerized tomography imaging in detection of atherosclerotic plaque
9
作者 Jianwei Yuan Yanlin Feng +1 位作者 Lingxiao Fan Xiaohong He 《Journal of Nanjing Medical University》 2008年第1期61-65,共5页
Objective:To evaluate the clinical value with positron emission tomography/computerized tomography(PET/CT) imaging for the detection of vulnerable plaque in atherosclerotic lesions. Methods:Sixty people with a age... Objective:To evaluate the clinical value with positron emission tomography/computerized tomography(PET/CT) imaging for the detection of vulnerable plaque in atherosclerotic lesions. Methods:Sixty people with a age of over 60[mean age (69.2 ± 7.1)years] underwent three dimension(3D) whole-body fluorine-18-2-fluoro-2-deoxy-D-glucose(^18F-FDG) PET/CT imaging and were evaluated retrospectively, including 6 cases assessed as normal and 54 cases with active atherosclerotic plaque. Fifty-four cases with SUVs and CT values in the aortic wall of high-FDG-uptake were measured retrospectively. These high-FDG-uptake cases in the aortic wall were divided into three groups according their CT value. Cases in group 1 had high uptake in atherosclerotic lesions of the aortic wall with CT value of less than 60 Hu(soft plaque). Cases in group 2 had high uptake with CT value between 60-100 Hu (intermediate plaque), Cases in group 3 had high uptake with CT value more than 100 Hu(calcified plaque), Group 4 was normal. Results: In group 1, there were 42 high-FDG-uptake sites (average SUV 1.553 ± 0.486). In group 2, there were 30 high-FDG-uptake sites(average SUV 1.393 ± 0.296). In group 3, there were 36 high-FDG-uptake sites(average SUV 1.354 ± 0.189). In group 4, there were 33 normal-FDG-uptake sites (average SUV was 1.102 ± 0.141), The SUVs showed significant difference among the four groups(F = 678.909, P = 0.000). There were also significant difference found between the normal-FDG-uptake group and the high-FDG-uptake groups(P = 0.000, 0.000, 0.001, respectively). Conclusion:Different degrees of ^18F-FDG uptake in active large atherosclerotic plaque were shown in different stages of atherosclerotic plaque formation. The soft plaque had the highest FDG uptake in this study. This suggested that ^18F- FDG PET/CT imaging may be of great potential value in early diagnosis and monitoring of vulnerable soft plaque in atherosclerotic lesions. 展开更多
关键词 fluorine-18-2-fluoro-2-deoxy-D-glucose positron-emission tomography computerized tomography ATHEROSCLEROSIS vulnerable plaque
下载PDF
Validations of new cut-offs for surgical drains management and use of computerized tomography scan after pancreatoduodenectomy:The DALCUT trial
10
作者 Damiano Caputo Alessandro Coppola +5 位作者 Vincenzo La Vaccara Roberto Passa Ludovico Carbone Massimo Ciccozzi Silvia Angeletti Roberto Coppola 《World Journal of Clinical Cases》 SCIE 2022年第15期4836-4842,共7页
BACKGROUND Postoperative pancreatic fistula(POPF)is the most fearful complication after pancreatic surgery and can lead to severe postoperative complications such as surgical site infections,sepsis and bleeding.A prev... BACKGROUND Postoperative pancreatic fistula(POPF)is the most fearful complication after pancreatic surgery and can lead to severe postoperative complications such as surgical site infections,sepsis and bleeding.A previous study which identified cut-offs of drains amylase levels(DALs)determined on postoperative day(POD)1 and POD3,was able to significantly predict POPF,abdominal collections and biliary fistulas,when related to specific findings detected at the abdominal computerized tomography(CT)scan routinely performed on POD3.AIM To validate the cut-offs of DALs in POD1 and POD3,established during the previous study,to assess the risk of clinically relevant POPF and confirm the usefulness of abdominal CT scan on POD3 in patients at increased risk of abdominal collection.METHODS The DALCUT trial is an interventional prospective study.All patients who will undergo pancreatoduodenectomy(PD)for periampullary neoplasms will be considered eligible.All patients will receive clinical staging and,if eligible for surgery,will undergo routine preoperative evaluation.After the PD,daily DALs will be evaluated from POD1.Drains removal and possible requirement of abdominal CT scans in POD3 will be managed on the basis of the outcome of DALs in the first three postoperative days.RESULTS This prospective study could validate the role of DALs in the management of surgical drains and in assessing the risk or relevant complications after PD.Drains could be removed in POD3 in case of POD1 DALs<666 U/L and POD3 DALs<207 U/L.In case of POD3 DALs≥252,abdominal CT scan will be performed in POD3 to identify abdominal collections≥5 cm.In this latter category of patients,drains could be maintained beyond POD3.CONCLUSION The results of this trial will contribute to a better knowledge of POPF and management of surgical drains. 展开更多
关键词 Pancreatic surgery Drains amylase Pancreatic fistula Postoperative complications computerized tomography scan
下载PDF
X-Ray Industrial Computerized Tomography System for Testing Advanced Structural Ceramics
11
作者 张朝宗 《High Technology Letters》 EI CAS 1995年第2期86-89,共4页
This paper presents a X-ray industrial CT system with an image intensifier for NDT of ceramics, which was developed by Tsinghua University in 1990, and another one with discrete detectors, which is under constructing,... This paper presents a X-ray industrial CT system with an image intensifier for NDT of ceramics, which was developed by Tsinghua University in 1990, and another one with discrete detectors, which is under constructing, and puts forward the work plan for the near future. 展开更多
关键词 ct tomography DETEctOR RECONSTRUctION CERAMICS RADIOGRAPHY
下载PDF
优化双下肢动脉能谱CT血管造影成像方案 被引量:1
12
作者 胡莹莹 张珂 +3 位作者 何辰宇 孙宏亮 王蕾 谢晟 《中国介入影像与治疗学》 北大核心 2024年第4期242-246,共5页
目的优化双下肢动脉能谱CT血管造影(CTA)成像方案。方法回顾性分析30例疑诊双下肢动脉硬化性闭塞症(ASO)患者双下肢动脉能谱CTA资料,经重建获得40~80 keV(间隔5 keV)单能量(共9种)及100 kVp混合能量图像,对比双下肢动脉在不同图像中的C... 目的优化双下肢动脉能谱CT血管造影(CTA)成像方案。方法回顾性分析30例疑诊双下肢动脉硬化性闭塞症(ASO)患者双下肢动脉能谱CTA资料,经重建获得40~80 keV(间隔5 keV)单能量(共9种)及100 kVp混合能量图像,对比双下肢动脉在不同图像中的CT值、噪声(SD)值、信噪比(SNR)及对比度噪声比(CNR);针对50、60 keV单能量和100 kVp混合能量图像质量及血管节段的可诊断性进行主观评估,观察40、45、50、60 keV单能量和100 kVp混合能量图像的自动去骨能力。结果40~80 keV范围内,随keV升高,各动脉在图像中的CT值、SD值、SNR及CNR均逐渐降低。相比100 kVp,腘动脉(PA)及其近端动脉的CT值、CNR及SNR均在40~55 keV图像中升高(P均<0.05);50~55 keV图像中SD值升高(P均<0.05),而60 keV图像中差异无统计学意义(P>0.05)。50及60 keV图像质量主观评分及可诊断动脉节段数与100 kVp差异均无统计学意义(P均>0.05)。PA以远节段的SNR及CNR在各单能量图像及100 kVp图像中差异均无统计学意义,其CT值在40~45 keV图像中、SD在40 keV图像中均高于100 kVp(P均<0.05),但SD在45 keV与100 kVp图像中差异无统计学意义(P>0.05);50 keV图像中,PA以远节段图像质量主观评分及可诊断节段数均高于60 keV及100 kVp(P均<0.05)。40 keV图像对9例(9/30,30.00%)、45 keV图像对6例(6/30,20.00%)不能自动去骨,50及60 keV、100 kVp对30例(30/30,100%)均可自动去骨。结论行双下肢动脉能谱CTA时,对PA及其近端节段以60 keV单能量成像较佳,对其以远或双下肢全程则以50 keV单能量成像较佳。 展开更多
关键词 下肢 动脉 ct血管成像 能谱ct
下载PDF
基于增强CT影像组学预测食管鳞癌淋巴血管侵犯状态的价值 被引量:1
13
作者 李扬 王向明 +8 位作者 谷霄龙 杨丽 王琦 时高峰 随义 徐校胜 岳萌 王明博 任嘉梁 《放射学实践》 CSCD 北大核心 2024年第2期239-246,共8页
目的:探讨基于增强CT影像组学预测食管鳞癌(ESCC)淋巴血管侵犯(LVI)的价值。方法:回顾性搜集行根治性切除术并经术后病理证实的224例食管鳞癌患者,其中包括66例LVI阳性和158例LVI阴性患者。所有患者均在术前2周内进行胸部增强CT扫描。... 目的:探讨基于增强CT影像组学预测食管鳞癌(ESCC)淋巴血管侵犯(LVI)的价值。方法:回顾性搜集行根治性切除术并经术后病理证实的224例食管鳞癌患者,其中包括66例LVI阳性和158例LVI阴性患者。所有患者均在术前2周内进行胸部增强CT扫描。将入组的患者按照7:3的比例随机分为训练集和测试集。使用3D Slicer软件逐层勾画全肿瘤感兴趣区(ROI),采用Python软件的Pyradiomics包提取肿瘤组织的影像组学特征,建立影像组学模型用于预测食管鳞癌的LVI状态并进行验证。采用受试者工作特征(ROC)曲线的曲线下面积(AUC)、敏感度、特异度、准确度、阳性预测值和阴性预测值来评价影像组学模型的诊断效能,使用校准曲线评价影像组学模型在训练集和测试集中的拟合程度。使用决策曲线分析(DCA)评价影像组学模型的临床应用价值。结果:从全肿瘤ROI中提取了1130个组学特征,经过筛选最终保留了7个影像组学特征,并使用多因素logistic回归建立影像组学预测模型。在训练集中,影像组学模型预测LVI的AUC值为0.930,敏感度为0.851,特异度为0.919,准确度为0.899,阳性预测值为0.816,阴性预测值为0.936;在测试集中,AUC值为0.897,敏感度为0.789,特异度为0.787,准确度为0.788,阳性预测值为0.600,阴性预测值为0.902。校准曲线显示影像组学模型在训练集及测试集中的预测概率与实际概率的一致性良好。DCA曲线显示影像组学模型具有良好的临床应用价值。结论:基于增强CT构建的影像组学模型,能够在术前有效预测食管鳞癌的LVI状态。 展开更多
关键词 食管鳞癌 影像组学 淋巴血管侵犯 体层摄影术 X线计算机 增强ct
下载PDF
人工智能诊断系统及CT无创血流储备分数在评估高海拔地区 冠脉临界病变中的应用 被引量:1
14
作者 王雪燕 曹云太 +3 位作者 韩千程 颜梅 韩玲 温生宝 《分子影像学杂志》 2024年第6期616-621,共6页
目的探讨基于冠状动脉CT血管成像(CCTA)的人工智能(AI)诊断系统及CT无创血流储备分数(CT-FFR)在评估高海拔地区冠状动脉临界病变结构及功能学中的应用价值。方法前瞻性收集2022年1月~2023年10月青海大学附属医院冠心病临界病变患者164例... 目的探讨基于冠状动脉CT血管成像(CCTA)的人工智能(AI)诊断系统及CT无创血流储备分数(CT-FFR)在评估高海拔地区冠状动脉临界病变结构及功能学中的应用价值。方法前瞻性收集2022年1月~2023年10月青海大学附属医院冠心病临界病变患者164例,按居住地海拔进行分组,其中2000~3000m为A组(n=83),3000m以上为B组(n=81),再将两组患者按冠脉狭窄程度细分为50%~60%亚组(n=84)和61%~70%亚组(n=80)。将患者冠状动脉CT血管成像数据导入AI辅助诊断及CT-FFR测量系统,以冠脉造影及冠脉传统血流储备分数(FFR)为金标准,分别评价AI及CT-FFR在高海拔地区冠脉临界病变诊断中的应用。结果以FFR为金标准,CT-FFR与FFR的一致性为83.75%。B组钙化斑块、易损斑块高于A组(P=0.037、0.020);B组冠状动脉多支病变、61%~70%狭窄程度发生率均高于A组(P<0.05);A组、B组在61%~70%亚组钙化斑块、易损斑块发生率均高于50%~60%亚组(P<0.05)。B组CT-FFR值低于A组(0.76±0.04 vs 0.88±0.05,P<0.01);A、B两组在61%~70%亚组CT-FFR值≤0.80、<0.70的发生率高于50%~60%亚组(P<0.05)。结论AI诊断系统及CT-FFR对评估高海拔地区冠状动脉临界病变的结构特征及血流动力学改变的结果与冠脉造影、FFR一致性高,具有较高的诊断敏感度和特异度。 展开更多
关键词 人工智能 冠状动脉 ct无创血流储备分数 ct血管成像 冠脉临界病变
下载PDF
定量CT评价胸椎骨密度及与年龄相关的骨丢失
15
作者 赵君禄 刘斋 +2 位作者 赵德园 聂关伟 任庆云 《实用医学杂志》 CAS 北大核心 2024年第10期1429-1433,共5页
目的探讨胸椎定量CT(QCT)测量骨密度及骨丢失率的可行性。方法选取因健康体检及急腹症行全腹部CT扫描的患者708例,使用QCT软件测量T10-L3椎体骨密度。将受检者按每10岁为一个年龄段分组。计算每个年龄组的胸椎及腰椎骨密度,并计算各组... 目的探讨胸椎定量CT(QCT)测量骨密度及骨丢失率的可行性。方法选取因健康体检及急腹症行全腹部CT扫描的患者708例,使用QCT软件测量T10-L3椎体骨密度。将受检者按每10岁为一个年龄段分组。计算每个年龄组的胸椎及腰椎骨密度,并计算各组别的峰值骨密度及骨丢失率。胸椎与腰椎骨密度及其与年龄的相关性采用Pearson相关分析。结果男性、女性骨密度峰值均在20~29岁年龄组,30岁以后胸腰椎骨密度开始不同程度减低,80~89岁女性胸椎及腰椎累计骨丢失率分别为60.61%及61.34%,而男性分别为44.45%及49.35%。男性与女性胸腰椎骨密度均与年龄呈负相关(P<0.01)。胸椎与腰椎骨密度呈正相关(男性r=0.96、女性r=0.98,P<0.01)。结论胸椎及腰椎QCT均能准确地显示不同年龄组的骨密度及骨丢失情况,胸椎QCT可以作为评价和监测骨丢失的一种方法。 展开更多
关键词 骨丢失 骨密度 体层摄影术 X线计算机 定量ct 胸椎
下载PDF
超声与CT技术在高原地区藏族人群肺结核疾病诊断价值的比较研究
16
作者 张文 刘晓宇 +4 位作者 温智峰 刘有云 冶骏 王琰 叶俊 《中国医学装备》 2024年第7期92-95,共4页
目的:比较研究高原地区藏族人群肺结核患者超声与CT影像特点及诊断价值。方法:选择2022年5月至2023年11月青海省中医院收治的100例高原地区藏族人群肺结核患者,所有患者均行超声与CT检查,动态观察高原地区肺结核患者肺部病变的超声影像... 目的:比较研究高原地区藏族人群肺结核患者超声与CT影像特点及诊断价值。方法:选择2022年5月至2023年11月青海省中医院收治的100例高原地区藏族人群肺结核患者,所有患者均行超声与CT检查,动态观察高原地区肺结核患者肺部病变的超声影像学特点,比较超声与CT检查对高原地区藏族人群肺结核的诊断效果。结果:超声与CT检查高原地区藏族人群肺结核的阳性检出率比较,差异无统计学意义(χ^(2)=0.053,P>0.05)。超声诊断的灵敏度为97.80%、特异度为44.44%、约登指数42.24%,CT诊断的灵敏度为96.77%、特异度为42.86%、约登指数39.63%,差异无统计学意义(χ^(2)=0.184,0.004,0.272,P>0.05)。超声与CT检查高原地区藏族人群肺结核病变肺叶分布检出率比较,差异无统计学意义(χ^(2)=2.011,P>0.05)。超声与CT检查对高原地区藏族人群肺结核患者肺不张、空洞、钙化、伴随胸水的检出率比较,差异无统计学意义(χ^(2)=0.190,0.197,0.190,0.046,P>0.05)。结论:超声检查的阳性检出率、病变肺叶分布检出率和肺不张、空洞、钙化、伴随胸水等肺结核并发或伴随征象检出率均与CT检查无差异,而高原地区医疗资源匮乏,缺少大型检查设备,应用超声检查进行肺结核普查及初步诊断,对缺少CT设备或受电力影响的高原地区更适合。 展开更多
关键词 高原地区 藏族人群 肺结核 超声 计算机体层成像 诊断
下载PDF
不同扫描延迟技术在大螺距冠状动脉CT血管成像中的对比研究
17
作者 丁毅 宋彬 +1 位作者 朱时珍 徐晶晶 《蚌埠医学院学报》 CAS 2024年第3期386-390,共5页
目的:比较2种扫描延迟技术在大螺距冠状动脉CT血管成像(CCTA)中运用的可行性。方法:前瞻性收集临床疑似冠心病行CCTA检查的心率≤60次/分病人58例,随机分为团注跟踪组31例和测试团注组27例。分别在主动脉根部、左主干、左前降支近段、... 目的:比较2种扫描延迟技术在大螺距冠状动脉CT血管成像(CCTA)中运用的可行性。方法:前瞻性收集临床疑似冠心病行CCTA检查的心率≤60次/分病人58例,随机分为团注跟踪组31例和测试团注组27例。分别在主动脉根部、左主干、左前降支近段、左回旋支近段、右冠状动脉近段、肺动脉、左心房和左心室选取感兴趣区,测量CT值和噪声,计算信噪比、对比噪声比、左房室比、左室肺动脉比和主肺动脉比,评估2组图像质量,比较2组客观和主观评价指标差异。结果:2组各目标血管强化CT值、信噪比和对比噪声比差异均无统计学意义(P>0.05),团注跟踪组肺动脉CT值、左房室比、左室肺动脉比和主肺动脉比均明显低于测试团注组(P<0.01)。2组主观图像质量评分差异无统计学意义(P>0.05)。团注跟踪组CT剂量指数、剂量长度乘积、有效辐射剂量、注射流率和对比剂量均低于测试团注组(P<0.05~P<0.01)。结论:大螺距CCTA采用团注跟踪技术,可提高血管强化CT值并能降低辐射剂量和对比剂用量。 展开更多
关键词 冠状动脉ct血管成像 计算机体层摄影术 测试团注 团注跟踪
下载PDF
疑诊原发性甲状旁腺功能亢进症的患者术前^(99m)Tc-MIBI SPECT/CT显像结果的影响因素分析
18
作者 郭月红 黄京伟 +1 位作者 张腾 杨敏福 《首都医科大学学报》 CAS 北大核心 2024年第1期31-35,共5页
目的探讨疑诊原发性甲状旁腺功能亢进症(primary hyperparathyroidism,PHPT)的患者术前^(99m)Tc-甲氧基异丁基异腈(methoxyisobutylisonitrile,MIBI)单光子发射计算机断层扫描/计算机断层扫描(single-photon emission computed tomograp... 目的探讨疑诊原发性甲状旁腺功能亢进症(primary hyperparathyroidism,PHPT)的患者术前^(99m)Tc-甲氧基异丁基异腈(methoxyisobutylisonitrile,MIBI)单光子发射计算机断层扫描/计算机断层扫描(single-photon emission computed tomography/computed tomography,SPECT/CT)(以下简称MIBI SPECT/CT)显像结果的影响因素。方法将2019年1月至2023年8月于首都医科大学附属北京朝阳医院疑诊PHPT并在术前完善甲状旁腺MIBI SPECT/CT显像的257例患者作为研究对象。比较MIBI SPECT/CT显像阳性组和阴性组的实验室检查、病理特征及影像特征。采用多因素Logistic回归分析MIBI SPECT/CT显像结果的影响因素。结果单因素分析显示,与阴性组相比,血清总钙、血清甲状旁腺激素(parathyroid hormone,PTH)、碱性磷酸酶(alkaline phosphatase,ALP)水平在阳性组显著升高(P<0.05);病灶的病理类型、最大径、体积及位置在两组间差异有统计学意义(P<0.05)。多因素Logistic回归分析显示,术前血清PTH水平、病灶病理类型、位置及最大径与MIBI SPECT/CT显像结果阳性显著相关(P<0.05)。结论疑诊PHPT患者术前MIBI SPECT/CT显像结果受多重因素影响,术前血清PTH水平、病灶病理类型、位置及最大径是MIBI SPECT/CT显像结果的独立影响因素。 展开更多
关键词 原发性甲状旁腺功能亢进症(PHPT) ^(99m)Tc-甲氧基异丁基异腈(MIBI) SPEct/ct
下载PDF
脊椎骨内神经鞘瘤的CT、MRI表现(附11例报道及文献复习)
19
作者 刘玉 王远军 李开成 《生物医学工程学进展》 CAS 2024年第2期136-141,共6页
目的探讨脊椎骨内神经鞘瘤(Intraosseous Schwannoma,IOS)的特征性影像学表现,以与其他脊椎溶骨性病变区别开。方法回顾性分析上海交通大学医学院附属第九人民医院经手术病理证实的脊椎IOS的临床资料及CT、MRI等影像学资料。该文收集了1... 目的探讨脊椎骨内神经鞘瘤(Intraosseous Schwannoma,IOS)的特征性影像学表现,以与其他脊椎溶骨性病变区别开。方法回顾性分析上海交通大学医学院附属第九人民医院经手术病理证实的脊椎IOS的临床资料及CT、MRI等影像学资料。该文收集了11例脊椎IOS患者,其中男性7例,女性4例,年龄23~74岁[平均年龄(51±17)岁]。所有患者均行CT和MRI检查。由两名高年资骨关节系统放射科医师对所有影像学征象进行评估,并复习了近几年来文献报告的脊椎IOS影像学征象。结果病变累及部位包括颈椎3例(3/11,27.3%),胸椎1例(1/11,9.1%),腰椎5例(5/11,45.5%),腰骶椎2例(2/11,18.2%),最大径(5.8±2.85)cm,形态均为不规则形。CT显示偏心性膨胀性溶骨性骨质破坏,密度不均匀,平扫CT值为(43.0±11.55)HU。增强后不均匀轻度强化,CT值为(70.3±12.22)HU,病灶边界清晰,有硬化缘,未见骨膜反应,病灶易沿着椎间孔向椎管内外延伸。在MRI上,与肌肉组织相比,病灶在T1WI上呈等稍低信号,在T2WI上呈混杂稍高信号,压脂后呈混杂高信号,DWI未见弥散受限,ADC值为(1.25±0.176)×10-3mm2/s,增强后不均匀明显强化,时间-信号强度曲线为I型,7例患者病灶内发生囊性变。结论脊椎IOS是一种罕见的良性肿瘤,影像学表现具有一定的特征性,在鉴别诊断边界清晰的具有异质性的脊椎溶骨性病变时应予以考虑。 展开更多
关键词 骨内神经鞘瘤 脊椎 计算机断层扫描 核磁共振
下载PDF
基于不同管电压的人工智能重建算法对胸部体模CT扫描图像质量和辐射剂量的影响研究
20
作者 惠庆桃 刘婷 +3 位作者 卿翔 李洁 王冠 马春 《中国医学装备》 2024年第3期19-23,共5页
目的:基于成年男性仿真胸部体模(PH-N1)CT扫描,探究不同管电压结合人工智能(AI)重建(CI)算法对胸部体模CT扫描图像质量和辐射剂量的影响。方法:采用512层超高端CT分为4种管电压对体模进行扫描,分别为70 kV、80 kV、100 kV和120 kV,对不... 目的:基于成年男性仿真胸部体模(PH-N1)CT扫描,探究不同管电压结合人工智能(AI)重建(CI)算法对胸部体模CT扫描图像质量和辐射剂量的影响。方法:采用512层超高端CT分为4种管电压对体模进行扫描,分别为70 kV、80 kV、100 kV和120 kV,对不同管电压的CT扫描图像采用10%、30%、50%、70%和90%CI算法重建1 mm薄层图像,比较4组扫描的容积剂量指数(CTDIvol)和剂量-长度乘积(DLP)。测量图像主动脉、腹壁脂肪及竖棘肌的CT值、标准偏差(SD)值,由两名5年以上工作经验的高年资诊断医师独立双盲的对图像质量进行5分制评估,并行Kappa一致性检验。采用单因素方差分析比较图像目标组织的CT值、SD值差异。采用Friedman秩和检验比较组间主观图像质量的差异。结果:4种不同管电压的CTDIvol和DLP比较,差异有统计学意义(F=1855.617、3996.118,P<0.05)。在70 kV管电压下,10%、30%、50%、70%和90%CI算法重建的主动脉、腹壁脂肪及竖棘肌的CT值比较,差异均无统计学意义(P>0.05),而SD值差异均有统计学意义(F=32.267、53.327、14.873,P<0.05)。在90%权重的CI算法重建4种不同管电压下,主动脉、腹壁脂肪及竖棘肌的CT值随着管电压的降低,CT值逐渐降低,差异有统计学意义(F=139.899、2563.93、219.231,P<0.05)。两名诊断医师对各组图像的主观评分一致性较好(Kappa=0.712~0.869)。结论:CI算法在70 kV管电压下90%权重的CI算法重建图像与80 kV、90 kV、120 kV图像相比,可以明显降低辐射剂量,同时图像具有良好信噪比。 展开更多
关键词 计算机体层摄影 人工智能 重建算法 图像质量 辐射剂量
下载PDF
上一页 1 2 219 下一页 到第
使用帮助 返回顶部