期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Application of Improved Hybrid Interface Substructural Component Modal Synthesis Method in Vibration Characteristics of Mistuned Blisk 被引量:5
1
作者 BAI Bin BAI Guangchen LI Chao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第6期1219-1231,共13页
The large and complex structures are divided into hundreds of thousands or millions degrees of freedom(DOF) when they are calculated which will spend a lot of time and the efficiency will be extremely low. The class... The large and complex structures are divided into hundreds of thousands or millions degrees of freedom(DOF) when they are calculated which will spend a lot of time and the efficiency will be extremely low. The classical component modal synthesis method (CMSM) are used extensively, but for many structures in the engineering of high-rise buildings, aerospace systemic engineerings, marine oil platforms etc, a large amount of calculation is still needed. An improved hybrid interface substructural component modal synthesis method(HISCMSM) is proposed. The parametric model of the mistuned blisk is built by the improved HISCMSM. The double coordinating conditions of the displacement and the force are introduced to ensure the computational accuracy. Compared with the overall structure finite element model method(FEMM), the computational time is shortened by23.86%–31.56%and the modal deviation is 0.002%–0.157% which meets the requirement of the computational accuracy. It is faster 4.46%–10.57% than the classical HISCMSM. So the improved HISCMSM is better than the classical HISCMSM and the overall structure FEMM. Meanwhile, the frequency and the modal shape are researched, considering the factors including rotational speed, gas temperature and geometry size. The strong localization phenomenon of the modal shape’s the maximum displacement and the maximum stress is observed in the second frequency band and it is the most sensitive in the frequency veering. But the localization phenomenon is relatively weak in 1st and the 3d frequency band. The localization of the modal shape is more serious under the condition of the geometric dimensioning mistuned. An improved HISCMSM is proposed, the computational efficiency of the mistuned blisk can be increased observably by this method. 展开更多
关键词 modal shape mistuned blisk vibration characteristics computational efficiency computational accuracy
下载PDF
Colorectal cancer screening:The role of CT colonography 被引量:6
2
作者 Andrea Laghi Franco Iafrate +1 位作者 Marco Rengo Cesare Hassan 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第32期3987-3994,共8页
Computed tomography colonography(CTC) in colorectal cancer(CRC) screening has two roles:one present and the other potential.The present role is,without any further discussion,the integration into established screening... Computed tomography colonography(CTC) in colorectal cancer(CRC) screening has two roles:one present and the other potential.The present role is,without any further discussion,the integration into established screening programs as a replacement for barium enema in the case of incomplete colonoscopy.The potential role is the use of CTC as a first-line screening method together with Fecal Occult Blood Test,sigmoidoscopy and colonoscopy.However,despite the fact that CTC has been officially endorsed for CRC screening of average-risk individuals by different scientif ic societies including the American Cancer Society,the American College of Radiology,and the US Multisociety Task Force on Colorectal Cancer,other entities,such as the US Preventive Services Task Force,have considered the evidence insuff icient to justify its use as a mass screening method.Medicare has also recently denied reimbursement for CTC as a screening test.Nevertheless,multiple advantages exist for using CTC as a CRC screening test:high accuracy,full evaluation of the colon in virtually all patients,non-invasiveness,safety,patient comfort,detection of extracolonic findings and cost-effectiveness.The main potential drawback of a CTC screening is the exposure to ionizing radiation.However,this is not a major issue,since low-dose protocols are now routinely implemented,delivering a dose comparable or slightly superior to the annual radiation exposure of any individual.Indirect evidence exists that such a radiation exposure does not induce additional cancers. 展开更多
关键词 Computed tomography colonography Colon neoplasms Colon polyps Colorectal cancer screening Computed tomography colonography safety Computed tomography colonography accuracy Computed tomography colonography radiation exposure Computed tomography colonography cost-effectiveness
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部