Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- reso...Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry.展开更多
An extensive 4 x 4 MIMO channel measurement is carried out at 6. 0-6. 4 GHz under a typical classroom environment with channel sounder based on vector network analyzer. Both LOS and NLOS scenarios are considered. The ...An extensive 4 x 4 MIMO channel measurement is carried out at 6. 0-6. 4 GHz under a typical classroom environment with channel sounder based on vector network analyzer. Both LOS and NLOS scenarios are considered. The results on path loss, delay spread and spatial correlation are presented. The measurement shows that, for corridor coverage, 2x2 MIMO is more economical than 4x4 MIMO due to high correlation. In order to identify the unique characteristics at the high frequency band, the measured channel parameters at 6. 0-6.4 GHz are compared with those at 2. 45 GHz. The comparison shows that the shortened wavelength of this higher frequency band results in a great difference of channel characteristics. Therefore, our measurement results provide new gnidance for the design and development of the system working on 6. 0-6.4 GHz band.展开更多
In this paper, we demonstrate a new optical method for tiny strain measurements based on the principle of carrier fringes of moire interferometry. A cross-line grating with frequency of 1200 lp/mm is replicated on the...In this paper, we demonstrate a new optical method for tiny strain measurements based on the principle of carrier fringes of moire interferometry. A cross-line grating with frequency of 1200 lp/mm is replicated on the specimen surface, and the strain can be deduced from the changes in carrier fringes before and after the deformation of an object. Four coherent laser beams are used to obtain the carrier fringe patterns of field U and V. Both theoretical analysis and numerical simulation indicate that the ideal accuracy of strain can be controlled within a range of ±1με. Case study of a plane extension experiment shows that the measurement accuracy of strain can be controlled within the range of ±10με. The average strain values of every row of field U and every column of field V can be obtained by using this method, and approximated strain of every pixel in the whole-field can be further acquired, and thus it is possible to measure tiny strains occurred in a micro-field. The technology in this paper can provide comprehensive information for analyzing related mechanical content in the field of MEMS.展开更多
In this paper the present authors measured the gas-particle two-phase velocity correlation in sudden expansion gas-particle flows with a phase Doppler particle anemometer (PDPA) and simulated the system behavior by ...In this paper the present authors measured the gas-particle two-phase velocity correlation in sudden expansion gas-particle flows with a phase Doppler particle anemometer (PDPA) and simulated the system behavior by using both a Reynolds-averaged Navier-Stokes (RANS) model and a large-eddy simulation (LES). The results of the measurements yield the axial and radial time-averaged velocities as well as the fluctuation velocities of gas and three particle-size groups (30μm, 50μm, and 95μm) and the gasparticle velocity correlation for 30μm and 50μm particles. From the measurements, theoretical analysis, and simulation, it is found that the two-phase velocity correlation of sudden-expansion flows, like that of jet flows, is less than the gas and particle Reynolds stresses. What distinguishes the two-phase velocity correlations of sudden-expansion flow from those of jet and channel flows is the absence of a clear relationship between the two-phase velocity correlation and particle size in sudden-expansion flows. The measurements, theoretical analysis, and numerical simulation all lead to the above-stated conclusions. Quantitatively, the results of the LES are better than those of the RANS model.展开更多
To realize the automation of fashion industry measuring,designing and manufacturing, the auto-measurement of 3D size of human body is of great importance. The auto measurement system of 3D human body based on Charge C...To realize the automation of fashion industry measuring,designing and manufacturing, the auto-measurement of 3D size of human body is of great importance. The auto measurement system of 3D human body based on Charge Coupled Devices (CCD) and infrared sensors is presented in this paper. The system can measure the bare size of human body that excludes the effect of clothing quickly and accurately.展开更多
3 - dimensional body measurement technology, the basis of developing high technology in industry, accelerates digital development of aplparel industry. This paper briefly introduces the history of 3 - dimensional body...3 - dimensional body measurement technology, the basis of developing high technology in industry, accelerates digital development of aplparel industry. This paper briefly introduces the history of 3 - dimensional body measurement technology, and recounts the principle and primary structure of some types of 3 - dimensional automatic body measurement system. With this understanding, it discusses prospect of 3- dimensional CAD and virtual technology used in apparel industry.展开更多
This paper clarifies the steady-state properties and performance of an α-β filter for moving target tracking using both position and velocity measurements. We call this filter velocity measured α-β (VM-α-β) filt...This paper clarifies the steady-state properties and performance of an α-β filter for moving target tracking using both position and velocity measurements. We call this filter velocity measured α-β (VM-α-β) filter. We first derive the stability condition and steady-state predicted errors as fundamental properties of the VM-α-β filter. The optimal gains for representative motion models are then derived from the Kalman filter equations. Theoretical and numerical analyses verify that VM-α-β filters with these optimal gains realize more accurate tracking than conventional α-β filters when the filter gains are relatively large. Our study reveals the conditions under which the predicted errors of the VM-α-β filters are less than those of conventional α-β filters. Moreover, numerical simulations clarify that the variance of the tracking error of the VM-α-β filters is approximately 3/4 of that of the conventional α-β filters in realistic situations, even when the accuracy of the position/velocity measurements is the same.展开更多
This paper investigates the normality of some real data set obtained from waist measurements of a group of 49 young adults. The quantile - quantile (Q-Q) plot and the analysis of correlation coefficients for the Q-Q...This paper investigates the normality of some real data set obtained from waist measurements of a group of 49 young adults. The quantile - quantile (Q-Q) plot and the analysis of correlation coefficients for the Q-Q plot is used to determine the normality or otherwise of the data set. In this regards, the probabilities of the quantiles were computed, modified and plotted. Thereafter the correlation coefficients for the quantile - quantile plots were obtained. Results indicate that at 0.1 level of significance, the data for young adult males of the sample were not normally distributed, and had a mean value that is within the range of low risk, healthwise, whereas the distribution of the data for young female adults showed reasonable normality, but also with a mean value that is within the range of low risk in terms of health condition.展开更多
This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In c...This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In comparison with the conventional solutions which are based on detecting the expected output R(s)and output C(s)to obtain error signal E(s),the measurement errors are eliminated even the error might be at a significant level.Moreover,it is possible that the individual debugging by regulating the coefficient K for every member of the multiple objectives achieves the optimization of the open loop gain.Therefore,this simple method can be applied to the weak coupling and multiple objectives system,which is usually controlled by complex controller.The principle of eliminating measurement errors is derived analytically,and the advantages comparing with the conventional solutions are depicted.Based on the SSEC method analysis,an application of this method for an active power filter(APF)is investigated and the effectiveness and viability of the scheme are demonstrated through the simulation and experimental verifications.展开更多
When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air vel...When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer~. The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed.展开更多
International oil and gas projects feature high capital-intensity, high risks and contract diversity. Therefore, in order to help decision makers make more reasonable decisions under uncertainty, it is necessary to me...International oil and gas projects feature high capital-intensity, high risks and contract diversity. Therefore, in order to help decision makers make more reasonable decisions under uncertainty, it is necessary to measure the risks of international oil and gas projects. For this purpose, this paper constructs a probabilistic model that is based on the traditional economic evaluation model, and introduces value at risk(VaR) which is a valuable risk measure tool in finance, and applies Va R to measure the risks of royalty contracts, production share contracts and service contracts of an international oil and gas project. Besides, this paper compares the influences of different risk factors on the net present value(NPV) of the project by using the simulation results. The results indicate:(1) risks have great impacts on the project's NPV, therefore, if risks are overlooked, the decision may be wrong.(2) A simulation method is applied to simulate the stochastic distribution of risk factors in the probabilistic model. Therefore, the probability is related to the project's NPV, overcoming the inherent limitation of the traditional economic evaluation method.(3) VaR is a straightforward risk measure tool, and can be applied to evaluate the risks of international oil and gas projects. It is helpful for decision making.展开更多
Direct current measurements at the mooring station M southwest of Yonakuni-jima are carried out from May 18 to June 1, 1996. The Observed Kuroshio Current at 290 and 594 m depths of the mooring station M is quite stea...Direct current measurements at the mooring station M southwest of Yonakuni-jima are carried out from May 18 to June 1, 1996. The Observed Kuroshio Current at 290 and 594 m depths of the mooring station M is quite steady ddring the pened of Observation. The rotary spectral estimates of the current data by the maximum entropy method show that there are prominent diurnal and semidiurnal spectral peaks. The semidiurnal tide is predominant at 290 m depth while there is the current fluctuation with the inertial period except for the tidal oscillation at 594 m depth. There are also peaks at the pened of 4-7 d. There is a significant coherence between two time series of currents at 290 and 594 m depths in the pened range of 3 - 5 d. The Japan Meteorological Agency (JMA) wind data during the same period as the oceanic measurement are used in comparison with the current meter data. Rotary spectral estimates for the wind data show significant peaks at the period of 3 - 5 d. It is concluded from the cross spectra between the wind and the current that the current fluctuation of 3 - 5 d period at 290 m depth response to the wind fluctuation of the same periods with time lags smaller than 1 d.展开更多
A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS...A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.展开更多
Stiffness is one of the basic performance parameters for railway track. The efficient and accurate stiffness measurement has been considered as the foundation for further development of railway engineering, and theref...Stiffness is one of the basic performance parameters for railway track. The efficient and accurate stiffness measurement has been considered as the foundation for further development of railway engineering, and therefore has great theoretical and practical significance. Based on a summary of the connotation and measurement of track stiffness, the state of the art of measurement methods for track stiffness was analyzed systematically. The standstill measurement of track stiffness can be performed with the traditional jack-loading method, impact hammer method, FWD (falling weight deflectometer) method, and track loading vehicle method. Although these methods can be adopted in stiffness measurement for a section of railway track, they are not desirable owning to small range and low efficiency. In the recent 20 years, researchers have proposed many methods like unbalancedloading laser displacement method, deflection basin deformation rate method, and eccentricity excitation method to continuously measure track stiffness; however, these methods have drawbacks like poor accuracy, low speed, and insufficient data analysis. In this work, the merits and demerits of these methods were summarized, and optimization suggestions were presented. Based on the wave transmission mechanism and principle of vibration energy harvesting, an overall conception on continuous measurement of stiffness and long-term stiffness monitoring for special sections was proposed.展开更多
This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in...This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in natural water are provided by natural and artificial radionuclides such as ^(40) K,^(137)Cs,and radionuclides belonging to ^(238)U and ^(232)Th series.The main a emitters related to gamma emissions in natural water are ^(224)Ra(240.98 keV)and ^(226)Ra(186.21 keV),and the β^(-) emitters are ^(40) K(1460.85 keV),^(214)Bi(609.31 keV),^(208)Tl(583.19 keV),and ^(214)Pb(351.93 keV).The formula for gross α and β^(-) activity concentration is based on these radionuclides,and the short half-life decay products are considered in the calculation.The detection efficiency of the device across energy region(0–3 MeV)is obtained through Monte Carlo simulation,and a calibration experiment is conducted to verify the simulation results.Gamma radioactivity is measured continuously for 114 d in Pixian County and Dongfeng Canal located in the Zouma River,Chengdu,Sichuan Province,China.A comparison of the calculation results and monitoring data from the Sichuan Management and Monitoring Center Station of Radioactive Environment indicates that the percentage and absolute error of a activity concentration is lower than 53%and 0.02 Bq/L,respectively,and that of β-activity concentration is lower than 33.2%and 0.016 Bq/L,respectively.The method can rapidly determine gross α and β^(-) activity concentrations in natural water online.展开更多
Abstract: A micro - power consumption non - contact temperature measuring instrument for big rotor is introduced. As it solves very well the signal coupling under high speed rotation and power supply problem for probe...Abstract: A micro - power consumption non - contact temperature measuring instrument for big rotor is introduced. As it solves very well the signal coupling under high speed rotation and power supply problem for probe, the instrument can realize persistent on - line temperature measurement for big rotor drived by the ordinary light transmitted by optical fiber under the room light.展开更多
The pellet injection experiments for fuelling and diagnostics have been carried out on the HL-1M tokamak. The eight-pellet injector was installed on HL-1M. A reliable monitordetector and camera system was set up to ta...The pellet injection experiments for fuelling and diagnostics have been carried out on the HL-1M tokamak. The eight-pellet injector was installed on HL-1M. A reliable monitordetector and camera system was set up to take initial pellet photographs and measure the initial pellet speed and size. High fuelling efficiency of 60 % - 100 % and a density profile with a peaking factor of 1.8 - 2.0 were obtained. The maximum density close to 10^14/cm^3 in HL-1M was achieved with newly optimized combined fuelling techniques. Two typical models of pellet ablation have been utilized for simulative calculation of the ablation rates in HL-1M. In comparison with the distribution of the measured Hα emission intensity from the digital data of the CCD camera, the experimental result seems more optimistic for core fuelling than theoretical predictions by the two models. The safety factor profile q(r) has been extracted from the information provided by the CCD camera during the pellet injection. The reliability of the measured results depends mainly on the calibration of the imaging space position. Based on the calibration, the measured q-profile becomes more reasonable than those published previously for the same shot number and same photograph.展开更多
文摘Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry.
基金Sponsored by the National Natural Science Foundation of China(Grant No.61371101)the Shenzhen Biological,Internet,New Energy and New Materials Industry Development Project(Grant No.JC201104210030A)+2 种基金the Science and Technology Basic Research Project of Shenzhen(Grant No.JC200903120174A)the Research Innovation Fund Project of HIT(Grant No.HIT.NSFIR.2010133)the WINDOW-Towards Pervasive Indoor Wireless Networks,and the European Commission under its 7th Framework Program(Grant No.318992)
文摘An extensive 4 x 4 MIMO channel measurement is carried out at 6. 0-6. 4 GHz under a typical classroom environment with channel sounder based on vector network analyzer. Both LOS and NLOS scenarios are considered. The results on path loss, delay spread and spatial correlation are presented. The measurement shows that, for corridor coverage, 2x2 MIMO is more economical than 4x4 MIMO due to high correlation. In order to identify the unique characteristics at the high frequency band, the measured channel parameters at 6. 0-6.4 GHz are compared with those at 2. 45 GHz. The comparison shows that the shortened wavelength of this higher frequency band results in a great difference of channel characteristics. Therefore, our measurement results provide new gnidance for the design and development of the system working on 6. 0-6.4 GHz band.
基金the Basal Research Funds of National Defence Science and Technology
文摘In this paper, we demonstrate a new optical method for tiny strain measurements based on the principle of carrier fringes of moire interferometry. A cross-line grating with frequency of 1200 lp/mm is replicated on the specimen surface, and the strain can be deduced from the changes in carrier fringes before and after the deformation of an object. Four coherent laser beams are used to obtain the carrier fringe patterns of field U and V. Both theoretical analysis and numerical simulation indicate that the ideal accuracy of strain can be controlled within a range of ±1με. Case study of a plane extension experiment shows that the measurement accuracy of strain can be controlled within the range of ±10με. The average strain values of every row of field U and every column of field V can be obtained by using this method, and approximated strain of every pixel in the whole-field can be further acquired, and thus it is possible to measure tiny strains occurred in a micro-field. The technology in this paper can provide comprehensive information for analyzing related mechanical content in the field of MEMS.
基金supported by the National Natural Science Foundation of China (50606026 and 50736006)
文摘In this paper the present authors measured the gas-particle two-phase velocity correlation in sudden expansion gas-particle flows with a phase Doppler particle anemometer (PDPA) and simulated the system behavior by using both a Reynolds-averaged Navier-Stokes (RANS) model and a large-eddy simulation (LES). The results of the measurements yield the axial and radial time-averaged velocities as well as the fluctuation velocities of gas and three particle-size groups (30μm, 50μm, and 95μm) and the gasparticle velocity correlation for 30μm and 50μm particles. From the measurements, theoretical analysis, and simulation, it is found that the two-phase velocity correlation of sudden-expansion flows, like that of jet flows, is less than the gas and particle Reynolds stresses. What distinguishes the two-phase velocity correlations of sudden-expansion flow from those of jet and channel flows is the absence of a clear relationship between the two-phase velocity correlation and particle size in sudden-expansion flows. The measurements, theoretical analysis, and numerical simulation all lead to the above-stated conclusions. Quantitatively, the results of the LES are better than those of the RANS model.
基金This work was supported by the natural science foundation of Henan province(004061000)
文摘To realize the automation of fashion industry measuring,designing and manufacturing, the auto-measurement of 3D size of human body is of great importance. The auto measurement system of 3D human body based on Charge Coupled Devices (CCD) and infrared sensors is presented in this paper. The system can measure the bare size of human body that excludes the effect of clothing quickly and accurately.
基金item of significant subject construction in Shanghai
文摘3 - dimensional body measurement technology, the basis of developing high technology in industry, accelerates digital development of aplparel industry. This paper briefly introduces the history of 3 - dimensional body measurement technology, and recounts the principle and primary structure of some types of 3 - dimensional automatic body measurement system. With this understanding, it discusses prospect of 3- dimensional CAD and virtual technology used in apparel industry.
文摘This paper clarifies the steady-state properties and performance of an α-β filter for moving target tracking using both position and velocity measurements. We call this filter velocity measured α-β (VM-α-β) filter. We first derive the stability condition and steady-state predicted errors as fundamental properties of the VM-α-β filter. The optimal gains for representative motion models are then derived from the Kalman filter equations. Theoretical and numerical analyses verify that VM-α-β filters with these optimal gains realize more accurate tracking than conventional α-β filters when the filter gains are relatively large. Our study reveals the conditions under which the predicted errors of the VM-α-β filters are less than those of conventional α-β filters. Moreover, numerical simulations clarify that the variance of the tracking error of the VM-α-β filters is approximately 3/4 of that of the conventional α-β filters in realistic situations, even when the accuracy of the position/velocity measurements is the same.
文摘This paper investigates the normality of some real data set obtained from waist measurements of a group of 49 young adults. The quantile - quantile (Q-Q) plot and the analysis of correlation coefficients for the Q-Q plot is used to determine the normality or otherwise of the data set. In this regards, the probabilities of the quantiles were computed, modified and plotted. Thereafter the correlation coefficients for the quantile - quantile plots were obtained. Results indicate that at 0.1 level of significance, the data for young adult males of the sample were not normally distributed, and had a mean value that is within the range of low risk, healthwise, whereas the distribution of the data for young female adults showed reasonable normality, but also with a mean value that is within the range of low risk in terms of health condition.
基金National Natural Science Foundation of China(No.61273172)
文摘This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In comparison with the conventional solutions which are based on detecting the expected output R(s)and output C(s)to obtain error signal E(s),the measurement errors are eliminated even the error might be at a significant level.Moreover,it is possible that the individual debugging by regulating the coefficient K for every member of the multiple objectives achieves the optimization of the open loop gain.Therefore,this simple method can be applied to the weak coupling and multiple objectives system,which is usually controlled by complex controller.The principle of eliminating measurement errors is derived analytically,and the advantages comparing with the conventional solutions are depicted.Based on the SSEC method analysis,an application of this method for an active power filter(APF)is investigated and the effectiveness and viability of the scheme are demonstrated through the simulation and experimental verifications.
文摘When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer~. The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed.
基金supported by the Young Fund of Shanxi University of Finance and Economics(No.QN-2018002)National Natural Science Foundation of China(No.71774105)the Fund for Shanxi Key Subjects Construction(FSKSC)and Shanxi Repatriate Study Abroad Foundation(No.2016-3)
文摘International oil and gas projects feature high capital-intensity, high risks and contract diversity. Therefore, in order to help decision makers make more reasonable decisions under uncertainty, it is necessary to measure the risks of international oil and gas projects. For this purpose, this paper constructs a probabilistic model that is based on the traditional economic evaluation model, and introduces value at risk(VaR) which is a valuable risk measure tool in finance, and applies Va R to measure the risks of royalty contracts, production share contracts and service contracts of an international oil and gas project. Besides, this paper compares the influences of different risk factors on the net present value(NPV) of the project by using the simulation results. The results indicate:(1) risks have great impacts on the project's NPV, therefore, if risks are overlooked, the decision may be wrong.(2) A simulation method is applied to simulate the stochastic distribution of risk factors in the probabilistic model. Therefore, the probability is related to the project's NPV, overcoming the inherent limitation of the traditional economic evaluation method.(3) VaR is a straightforward risk measure tool, and can be applied to evaluate the risks of international oil and gas projects. It is helpful for decision making.
文摘Direct current measurements at the mooring station M southwest of Yonakuni-jima are carried out from May 18 to June 1, 1996. The Observed Kuroshio Current at 290 and 594 m depths of the mooring station M is quite steady ddring the pened of Observation. The rotary spectral estimates of the current data by the maximum entropy method show that there are prominent diurnal and semidiurnal spectral peaks. The semidiurnal tide is predominant at 290 m depth while there is the current fluctuation with the inertial period except for the tidal oscillation at 594 m depth. There are also peaks at the pened of 4-7 d. There is a significant coherence between two time series of currents at 290 and 594 m depths in the pened range of 3 - 5 d. The Japan Meteorological Agency (JMA) wind data during the same period as the oceanic measurement are used in comparison with the current meter data. Rotary spectral estimates for the wind data show significant peaks at the period of 3 - 5 d. It is concluded from the cross spectra between the wind and the current that the current fluctuation of 3 - 5 d period at 290 m depth response to the wind fluctuation of the same periods with time lags smaller than 1 d.
基金supported by the National Natural Science Foundation of China(10772188)
文摘A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.
基金supported by the project (51425804) of the National Science Fund for Distinguished Young Scholars of Chinathe National Natural Science Foundation of China (NSFC) under grants U1234201, U1334203, and 51378439
文摘Stiffness is one of the basic performance parameters for railway track. The efficient and accurate stiffness measurement has been considered as the foundation for further development of railway engineering, and therefore has great theoretical and practical significance. Based on a summary of the connotation and measurement of track stiffness, the state of the art of measurement methods for track stiffness was analyzed systematically. The standstill measurement of track stiffness can be performed with the traditional jack-loading method, impact hammer method, FWD (falling weight deflectometer) method, and track loading vehicle method. Although these methods can be adopted in stiffness measurement for a section of railway track, they are not desirable owning to small range and low efficiency. In the recent 20 years, researchers have proposed many methods like unbalancedloading laser displacement method, deflection basin deformation rate method, and eccentricity excitation method to continuously measure track stiffness; however, these methods have drawbacks like poor accuracy, low speed, and insufficient data analysis. In this work, the merits and demerits of these methods were summarized, and optimization suggestions were presented. Based on the wave transmission mechanism and principle of vibration energy harvesting, an overall conception on continuous measurement of stiffness and long-term stiffness monitoring for special sections was proposed.
基金the National Science Foundation of China(No.41774147)the National Key R&D Program of China(No.2017YFC0602105)+1 种基金the Science–Technology Support Plan Projects of Sichuan Province(No.2020YJ0334)the Sichuan Science and Technology Program(No.2020JDRC0108).
文摘This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in natural water are provided by natural and artificial radionuclides such as ^(40) K,^(137)Cs,and radionuclides belonging to ^(238)U and ^(232)Th series.The main a emitters related to gamma emissions in natural water are ^(224)Ra(240.98 keV)and ^(226)Ra(186.21 keV),and the β^(-) emitters are ^(40) K(1460.85 keV),^(214)Bi(609.31 keV),^(208)Tl(583.19 keV),and ^(214)Pb(351.93 keV).The formula for gross α and β^(-) activity concentration is based on these radionuclides,and the short half-life decay products are considered in the calculation.The detection efficiency of the device across energy region(0–3 MeV)is obtained through Monte Carlo simulation,and a calibration experiment is conducted to verify the simulation results.Gamma radioactivity is measured continuously for 114 d in Pixian County and Dongfeng Canal located in the Zouma River,Chengdu,Sichuan Province,China.A comparison of the calculation results and monitoring data from the Sichuan Management and Monitoring Center Station of Radioactive Environment indicates that the percentage and absolute error of a activity concentration is lower than 53%and 0.02 Bq/L,respectively,and that of β-activity concentration is lower than 33.2%and 0.016 Bq/L,respectively.The method can rapidly determine gross α and β^(-) activity concentrations in natural water online.
文摘Abstract: A micro - power consumption non - contact temperature measuring instrument for big rotor is introduced. As it solves very well the signal coupling under high speed rotation and power supply problem for probe, the instrument can realize persistent on - line temperature measurement for big rotor drived by the ordinary light transmitted by optical fiber under the room light.
基金National Natural Science Foundation of China (No. 19889502)
文摘The pellet injection experiments for fuelling and diagnostics have been carried out on the HL-1M tokamak. The eight-pellet injector was installed on HL-1M. A reliable monitordetector and camera system was set up to take initial pellet photographs and measure the initial pellet speed and size. High fuelling efficiency of 60 % - 100 % and a density profile with a peaking factor of 1.8 - 2.0 were obtained. The maximum density close to 10^14/cm^3 in HL-1M was achieved with newly optimized combined fuelling techniques. Two typical models of pellet ablation have been utilized for simulative calculation of the ablation rates in HL-1M. In comparison with the distribution of the measured Hα emission intensity from the digital data of the CCD camera, the experimental result seems more optimistic for core fuelling than theoretical predictions by the two models. The safety factor profile q(r) has been extracted from the information provided by the CCD camera during the pellet injection. The reliability of the measured results depends mainly on the calibration of the imaging space position. Based on the calibration, the measured q-profile becomes more reasonable than those published previously for the same shot number and same photograph.