期刊文献+
共找到2,383篇文章
< 1 2 120 >
每页显示 20 50 100
Axial Bearing Capacity of Short FRP Confined Concrete-filled Steel Tubular Columns 被引量:7
1
作者 刘兰 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第3期454-458,共5页
The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined wit... The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results. 展开更多
关键词 columnS concrete-filled steel tubes (CFST) fiber reinforced polymer (FRP) CONFINEMENT bearing capacity.
下载PDF
Damage assessment for seismic response of recycled concrete filled steel tube columns 被引量:4
2
作者 Huang Yijie Xiao Jianzhuang Shen Luming 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第3期607-616,共10页
A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the eff... A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the effect of repeated cyclic loading into account. Available test results were collected and utilized to calibrate the parameters of the proposed model. A seismic test for six RCFST columns was also performed to validate the proposed damage assessment model. The main test parameters were the recycled coarse aggregate (RCA) replacement percentage and the bond-slip property. The test results indicated that the seismic performance of the RCFST member depends on the RCA contents and their damage index increases as the RCA replacement percentage increases. It is also indicated that the damage degree of RCFST changes with the variation of the RCA replacement percentage. Finally, comparisons between the RCA contents, lateral deformation ratio and damage degree were implemented. It is suggested that an improvement procedure should be implemented in order to compensate for the performance difference between the RCFST and normal concrete filled steel tubes (CFST). 展开更多
关键词 recycled aggregate concrete (RAC) recycled concrete filled steel tube (RCFST) column seismicperformance damage assessment model (DAM)
下载PDF
Seismic performance of recycled concrete-filled square steel tube columns 被引量:9
3
作者 Chen Zongping Jing Chenggui +1 位作者 Xu Jinjun Zhang Xianggang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期119-130,共12页
An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later... An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance. 展开更多
关键词 recycled concrete-filled square steel tube (RCFST) column replacement percentage cyclic loading seismicperformance
下载PDF
Bearing capacity of composite columns reinforced by concrete filled steel tube 被引量:1
4
作者 韦建刚 ZHU Pu CHEN Bao-chun 《Journal of Chongqing University》 CAS 2013年第1期27-34,共8页
In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance ... In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance under axial or eccentric compression. The failure mode is characterized by the crush of the outer concrete. The bearing capacity increases at first and then decreases with further increase of the position coefficient. It can be concluded that position coefficient is an important structural parameter that has considerable influences on the ultimate bearing capacity of the composite columns. The outer concrete, steel tubes and longitudinal reinforcement are found to work in a cooperative manner under axial or eccentric compression when the position coefficient is about 0.5. An improved bearing capacity algorithm that takes the position coefficient into account has been proposed based on the experimental and simulation results and current technical specification in China. It has been proven to be precise and safe. 展开更多
关键词 concrete filled steel tube composite column position factor TEST FORMULA
下载PDF
Seismic Behavior of Diaphragm-Through Connections of Concrete-Filled Square Steel Tubular Columns and H-Shaped Steel Beams 被引量:6
5
作者 荣彬 陈志华 +1 位作者 Apostolos Fafitis 苗纪奎 《Transactions of Tianjin University》 EI CAS 2013年第3期195-201,共7页
Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and us... Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections. 展开更多
关键词 concrete-filled square steel TUBULAR column H-shaped steel beam diaphragm-through connection seismic behavior load transfer mechanism
下载PDF
Three-dimensional nonlinear analysis of creep in concrete filled steel tube columns 被引量:1
6
作者 程晓东 李广宇 叶贵如 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期826-835,共10页
This paper proposes a based on 3D-VLE (three-dimensional nonlinear viscoelastic theory) three-parameters viscoelastic model for studying the time-dependent behaviour of concrete filled steel tube (CFT) columns. Th... This paper proposes a based on 3D-VLE (three-dimensional nonlinear viscoelastic theory) three-parameters viscoelastic model for studying the time-dependent behaviour of concrete filled steel tube (CFT) columns. The method of 3D-VLE was developed to analyze the effects of concrete creep behavior on CFT structures. After the evaluation of the parameters in the proposed creep model, experimental measurements of two prestressed reinforced concrete beams were used to investigate the creep phenomenon of three CFT columns under long-term axial and eccentric load was investigated. The experimentally obtained time-dependent creep behaviour accorded well with the cu~'es obtained from the proposed method. Many factors (such as ratio of long-term load to strength, slenderness ratio, steel ratio, and eccentricity ratio) were considered to obtain the regularity of influence of concrete creep on CFT structures. The analytical results can be consulted in the engineering practice and design. 展开更多
关键词 Three-dimensional virtual laminated element (3D-VLE) Creep analysis Three-dimensional viscoelastic theory Three-parameters viscoelastic model concrete filled steel tube columns
下载PDF
Influence of Axial Load Ratio on Shear Behavior of Through-Diaphragm Connections of Concrete-Filled Square Steel Tubular Columns 被引量:2
7
作者 张广泰 韩建红 +1 位作者 荣彬 Apostolos Fafitis 《Transactions of Tianjin University》 EI CAS 2015年第4期341-346,共6页
Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular c... Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular columns. The analysis reveals that smaller axial load ratio can improve the shear bearing capacity and ductility while larger axial load ratio will decrease the shear behavior of the through-diaphragm connections. The parametric studies indicate that the axial load ratio should be limited to less than 0.4 and its influence should be considered in the analysis and design of such connections. 展开更多
关键词 through-diaphragm connection concrete-filled square steel TUBULAR column AXIAL load ratio shearbearing capacity DUCTILITY
下载PDF
Performance Investigation of Square Concrete-filled Steel Tube Columns
8
作者 陈兵 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第4期730-736,共7页
The behaviour of square concrete-filled steel tube columns under concentrical loading was studied. More than one hundred specimens were tested to investigate the effects of thickness of steel tube on the load carrying... The behaviour of square concrete-filled steel tube columns under concentrical loading was studied. More than one hundred specimens were tested to investigate the effects of thickness of steel tube on the load carrying capacity of the concrete-filled tubular columns (CFTs). The effect of the grade of concrete and content of expansive agent were also investigated. The effect of these parameters on the confinement of the concrete core was studied as well. From the experimental study it was found that for both CFTs with different strength grade concrete core, the ultimate load carrying capacity increases with the increase in percentage of expansive agent up to 20% but it again decreases at 25% of expansive agent content. It was also shown that the failure mode of CFTs depends on the strength grade of concrete core. 展开更多
关键词 concrete filled steel tubes concrete columnS ultimate capacity expansive agent
下载PDF
Prediction of Axial Capacity of Concrete-Filled Square Steel Tubes Using Neural Networks
9
作者 朱美春 王清湘 冯秀峰 《Journal of Southwest Jiaotong University(English Edition)》 2005年第2期151-155,共5页
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret... The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns. 展开更多
关键词 concrete-filled square steel tubes Neural networks Axial capacity short columns
下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
10
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
Behaviors of recycled aggregate concrete-filled steel tubular columns under eccentric loadings 被引量:1
11
作者 Vivian W.Y.TAM Jianzhuang XIAO +1 位作者 Sheng LIU Zixuan CHEN 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2019年第3期628-639,共12页
The paper investigates the behaviors of recycled aggregate concrete-filled steel tubular(RACFST)columns under eccentric loadings with the incorporation of expansive agents.A total of 16 RACFST columns were tested in t... The paper investigates the behaviors of recycled aggregate concrete-filled steel tubular(RACFST)columns under eccentric loadings with the incorporation of expansive agents.A total of 16 RACFST columns were tested in this study.The main parameters varied in this study are recycled coarse aggregate replacement percentages(0%,30%,50%,70%,and 100%),expansive agent dosages(0%,8%,and 15%)and an eccentric distance of compressive load from the center of the column(0 and 40 mm).Experimental results showed that the ultimate stresses of RACFST columns decreased with increasing recycled coarse aggregate replacement percentages but appropriate expansive agent dosages can reduce the decrement;the incorporation of expansive agent decreased the ultimate stresses of RACFST columns but an appropriate dosage can increase the deformation ability.The recycled coarse aggregate replacement percentages have limited influence on the ultimate stresses of the RACFST columns and has more effect than that of the normal aggregate concretesteel tubular columns. 展开更多
关键词 concrete filled steel TUBES recycled AGGREGATE concrete columnS expansive agent ECCENTRIC load
原文传递
Axial compression tests and numerical simulation of steel reinforced recycled concrete short columns confined by carbon fiber reinforced plastics strips 被引量:1
12
作者 Hui MA Fangda LIU +2 位作者 Yanan WU Xin A Yanli ZHAO 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2022年第7期817-842,共26页
To research the axial compression behavior of steel reinforced recycled concrete(SRRC)short columns confined by carbon fiber reinforced plastics(CFRP)strips,nine scaled specimens of SRRC short columns were fabricated ... To research the axial compression behavior of steel reinforced recycled concrete(SRRC)short columns confined by carbon fiber reinforced plastics(CFRP)strips,nine scaled specimens of SRRC short columns were fabricated and tested under axial compression loading.Subsequently,the failure process and failure modes were observed,and load-displacement curves as well as the strain of various materials were analyzed.The effects on the substitution percentage of recycled coarse aggregate(RCA),width of CFRP strips,spacing of CFRP strips and strength of recycled aggregate concrete(RAC)on the axial compression properties of columns were also analyzed in the experimental investigation.Furthermore,the finite element model of columns which can consider the adverse influence of RCA and the constraint effect of CFRP strips was founded by ABAQUS software and the nonlinear parameter analysis of columns was also implemented in this study.The results show that the first to reach the yield state was the profile steel in the columns,then the longitudinal rebars and stirrups yielded successively,and finally RAC was crushed as well as the CFRP strips was also broken.The replacement rate of RCA has little effect on the columns,and with the substitution rate of RCA from 0 to 100%,the bearing capacity of columns decreased by only 4.8%.Increasing the CFRP strips width or decreasing the CFRP strips spacing could enhance the axial bearing capacity of columns,the maximum increase was 10.5%or 11.4%,and the ductility of columns was significantly enhanced.Obviously,CFRP strips are conducive to enhance the axial bearing capacity and deformation capacity of columns.On this basis,considering the restraint effect of CFRP strips and the adverse effects of RCA,the revised formulas for calculating the axial bearing capacity of SRRC short columns confined by CFRP strips were proposed. 展开更多
关键词 steel reinforced recycled concrete CFRP strips short columns axial compression behavior recycled aggregate concrete
原文传递
A New Method for Predicting the UL of Circular CFST Columns
13
作者 Xinmeng Yu Baochun Chen 《Open Journal of Civil Engineering》 2013年第3期188-193,共6页
Concrete filled steel tube structures have gained booming development in recent decades, especially in China. Simplified methods have been proposed in design codes, such as the Eurocode 4 (EC4) and the China engineeri... Concrete filled steel tube structures have gained booming development in recent decades, especially in China. Simplified methods have been proposed in design codes, such as the Eurocode 4 (EC4) and the China engineering and construction specification (CECS). In EC4, the confinement effect is reasonably related to slenderness and load eccentricity. The CECS method is much straight forward in that the slenderness ratio and load eccentricity are treated as independent reduction factors. To make use of the advantages of both the CECS and the EC4 methods, the CECS method is modified to consider the confinement effect associated with slenderness and load eccentricity. It is shown that the proposed method can predict well the ultimate load capacity of circular section concrete filled steel tube columns. 展开更多
关键词 concrete filled steel Tube column ULTIMATE Load Capacity Simplified Method Reduction Factor
下载PDF
高强钢管超高性能混凝土短柱轴压承载力性能试验研究 被引量:1
14
作者 陈俊 王秋湛 +3 位作者 郭鸣琴 曾琳惠 张学兵 谭鑫阳 《湘潭大学学报(自然科学版)》 CAS 2024年第2期20-34,共15页
为研究高强钢管内填超高性能混凝土(UHPC)的钢管混凝土短柱轴压性能,该文设计22根高强钢管UHPC短柱进行轴压试验,从破坏模式、荷载-纵向应变关系对试件的轴压性能进行对比分析,旨在通过径厚比、混凝土强度、截面类型等变化来探究高强钢... 为研究高强钢管内填超高性能混凝土(UHPC)的钢管混凝土短柱轴压性能,该文设计22根高强钢管UHPC短柱进行轴压试验,从破坏模式、荷载-纵向应变关系对试件的轴压性能进行对比分析,旨在通过径厚比、混凝土强度、截面类型等变化来探究高强钢管UHPC短柱的实际承载力性能差异.试验结果表明:高强钢管UHPC短柱的轴压性能受径厚比、混凝土强度影响较大;试件承载力随钢管壁厚增加而增加,但相同钢管直径和不同钢管直径增幅呈现不同规律.该文从延性、核心混凝土强度提高程度两个角度进行分析并提出高强钢管混凝土试件的相关参数设计建议.最后,将高强钢管UHPC短柱的轴压试验承载力结果与国内外规范GB 50936—2014、AIJ计算承载力结果进行对比,并基于极限平衡理论推导出高强圆钢管UHPC试件的轴压承载力计算公式,同时结合该文试验数据对其进行验证,证明了公式的准确性. 展开更多
关键词 高强钢管 超高性能混凝土 钢管混凝土短柱 极限承载力 试验研究
下载PDF
新型钢管混凝土梁柱节点力学性能试验研究 被引量:3
15
作者 张晓光 曹国旭 +1 位作者 黄远 李乾坤 《建筑结构》 北大核心 2024年第3期1-6,共6页
为研究内加强环式圆钢管混凝土柱与矩形钢管混凝土梁这种新型连接节点的力学性能,设计了缩尺钢管混凝土梁柱节点试件,开展了相同梁柱节点试件的静力加载试验和低周往复加载试验。通过研究该节点试件的破坏模式、荷载-位移曲线以及拟静... 为研究内加强环式圆钢管混凝土柱与矩形钢管混凝土梁这种新型连接节点的力学性能,设计了缩尺钢管混凝土梁柱节点试件,开展了相同梁柱节点试件的静力加载试验和低周往复加载试验。通过研究该节点试件的破坏模式、荷载-位移曲线以及拟静力加载试验的骨架曲线、核心区剪切变形等,分析了节点试件的承载能力、延性和耗能能力,全面考察了同一梁柱节点在静力加载和低周往复加载两种工况下的受力性能和破坏模式。结果表明:钢管混凝土梁柱节点试件核心区强度较强,破坏模式主要为梁端破坏,低周往复加载试验时试件梁柱连接处附近的梁端钢板发生拉裂破坏和钢板鼓曲,静力加载试验时试件梁端焊缝发生拉裂破坏;试件延性较好,加载过程中经历了弹性、弹塑性和塑性发展阶段。最后提出了该类钢管混凝土梁柱节点核心区的抗剪强度计算公式。 展开更多
关键词 钢管混凝土梁柱节点 内隔板 静力加载试验 低周往复加载试验 受力性能 设计方法
下载PDF
RPC外包方钢管混凝土柱轴压受力性能研究 被引量:1
16
作者 张仁巍 庄一舟 +1 位作者 曾武华 李伟 《浙江工业大学学报》 北大核心 2024年第1期25-34,共10页
为了研究活性粉末混凝土(Reactive powder concrete,RPC)外包方钢管混凝土柱的轴压受力性能,以RPC厚度和长细比为参数,对6根构件开展轴压试验研究,探讨该类组合柱的破坏模式、受力机理、套箍效应和承载力。试验结果表明:外层RPC可为内... 为了研究活性粉末混凝土(Reactive powder concrete,RPC)外包方钢管混凝土柱的轴压受力性能,以RPC厚度和长细比为参数,对6根构件开展轴压试验研究,探讨该类组合柱的破坏模式、受力机理、套箍效应和承载力。试验结果表明:外层RPC可为内部方钢管混凝土柱提供较强的约束力,在受力后期套箍效应凸显。随着RPC厚度的增加,组合柱的承载力逐渐提高;随着组合柱长细比的增大,虽然其弹性刚度和承载力逐渐降低,但延性改善。采用ABAQUS软件建立RPC外包方钢管混凝土柱的有限元模型,分析RPC强度、RPC厚度、钢管强度等级、含钢率、内部混凝土强度和长细比等参数对组合柱承载力的影响规律,可得方钢管混凝土柱发挥系数的变化幅值为0.78~1.01。在试验研究、有限元参数分析和理论探讨的基础上,借鉴钢管混凝土结构技术规范,提出了RPC外包方钢管混凝土轴压短柱和长柱的承载力简化计算方法,公式计算值与已有数据样本吻合良好。 展开更多
关键词 活性粉末混凝土 方钢管混凝土柱 轴压试验 有限元分析 承载力
下载PDF
反复荷载下圆钢管型钢再生混凝土组合柱恢复力模型研究 被引量:2
17
作者 马辉 刘一 +1 位作者 赵艳丽 白恒宇 《计算力学学报》 CAS CSCD 北大核心 2024年第2期320-327,共8页
为建立圆钢管型钢再生混凝土组合柱的恢复力模型,对11根圆钢管型钢再生混凝土组合柱试件进行了低周反复荷载试验研究,考虑了再生骨料取代率、配钢率及钢管径厚比等不同设计参数的影响,分析了组合柱的地震破坏形态及滞回性能。基于组合... 为建立圆钢管型钢再生混凝土组合柱的恢复力模型,对11根圆钢管型钢再生混凝土组合柱试件进行了低周反复荷载试验研究,考虑了再生骨料取代率、配钢率及钢管径厚比等不同设计参数的影响,分析了组合柱的地震破坏形态及滞回性能。基于组合柱的力学特征及曲线形状,提出了圆钢管型钢再生混凝土组合柱骨架曲线的三折线参数模型,采用理论推导与数据拟合的方法确定了组合柱骨架曲线的模型参数。在此基础上,给出了组合柱的滞回规则和卸载规律,构建了组合柱的恢复力模型,计算滞回曲线与试验滞回曲线吻合良好,表明该恢复力模型较好地反映了反复荷载下组合柱的受力特征点及滞回性能,可为此类组合柱的推广提供技术参考。 展开更多
关键词 型钢再生混凝土 钢管再生混凝土柱 恢复力模型 骨架曲线 滞回曲线
下载PDF
圆钢管型钢再生混凝土组合柱滞回性能非线性有限元分析 被引量:1
18
作者 马辉 张国恒 +2 位作者 白恒宇 席嘉诚 赵艳丽 《应用力学学报》 CAS CSCD 北大核心 2024年第1期148-157,共10页
基于圆钢管型钢再生混凝土组合柱低周反复荷载试验研究,采用OpenSees软件对该组合柱进行了滞回性能数值分析,获取了组合柱的滞回曲线及抗震性能指标,并与试验结果进行了比较,验证了组合柱数值模型的合理性。在此基础上,对组合柱的滞回... 基于圆钢管型钢再生混凝土组合柱低周反复荷载试验研究,采用OpenSees软件对该组合柱进行了滞回性能数值分析,获取了组合柱的滞回曲线及抗震性能指标,并与试验结果进行了比较,验证了组合柱数值模型的合理性。在此基础上,对组合柱的滞回性能开展了参数影响分析。结果表明:再生骨料取代率从0增大到100%,组合柱的峰值荷载下降了7.78%,延性略有降低;提高再生混凝土强度、型钢强度及圆钢管强度,对于提升组合柱的承载力及刚度是有利的,但却使组合柱的脆性增大;随着轴压比的增大,组合柱的承载力呈现先上升后下降的趋势,而延性逐渐变差;型钢配钢率从5.54%增至9.99%,组合柱的峰值荷载提高了24.34%,但对于改善组合柱的延性不明显;增大钢管壁厚对组合柱的承载力和延性均是有利的。 展开更多
关键词 钢管再生混凝土 型钢再生混凝土 组合柱 滞回性能 有限元分析
下载PDF
圆钢管型钢再生混凝土组合柱水平承载力计算方法研究 被引量:1
19
作者 王磊 《建筑结构》 北大核心 2024年第8期20-26,共7页
通过对11个圆钢管型钢再生混凝土组合柱进行低周反复荷载试验,分析再生粗骨料取代率、型钢截面形式、轴压比、型钢配钢率及圆钢管壁厚参数对组合柱水平承载力的影响规律;观察了组合柱的破坏形态及特征,研究了圆钢管、型钢翼缘及腹板应... 通过对11个圆钢管型钢再生混凝土组合柱进行低周反复荷载试验,分析再生粗骨料取代率、型钢截面形式、轴压比、型钢配钢率及圆钢管壁厚参数对组合柱水平承载力的影响规律;观察了组合柱的破坏形态及特征,研究了圆钢管、型钢翼缘及腹板应变的发展规律,分析了组合柱的地震破坏特征。研究表明,在水平地震作用下组合柱发生典型的压弯塑性铰破坏。在此基础上,结合现有规范提出了基于叠加原理的圆钢管型钢再生混凝土组合柱水平承载力计算方法。计算结果表明,其水平承载力计算值与试验值吻合度较好,能较为准确地预测组合柱的水平承载力。 展开更多
关键词 型钢再生混凝土 圆钢管混凝土柱 破坏机理 低周反复荷载试验 水平承载力 计算方法
下载PDF
高寒环境温度下钢管混凝土柱抗震性能试验研究
20
作者 虞庐松 王庚 +3 位作者 王力 周晓夫 顾皓玮 李子奇 《地震工程学报》 CSCD 北大核心 2024年第6期1251-1258,共8页
为探究高寒地区环境温度对圆钢管混凝土柱抗震性能的影响,开展4种不同温度工况下钢管混凝土柱的拟静力试验研究,分析不同环境温度下各试件的破坏特征、承载力、滞回特性、刚度退化、延性及耗能能力,揭示环境温度变化对钢管混凝土柱抗震... 为探究高寒地区环境温度对圆钢管混凝土柱抗震性能的影响,开展4种不同温度工况下钢管混凝土柱的拟静力试验研究,分析不同环境温度下各试件的破坏特征、承载力、滞回特性、刚度退化、延性及耗能能力,揭示环境温度变化对钢管混凝土柱抗震性能的影响规律。试验结果表明:不同环境温度下各试件滞回曲线均呈梭形,未产生明显捏缩现象;试件典型破坏模式在不同温度下基本一致,均为钢管底部产生一圈贯通鼓曲波、核心混凝土被压溃、钢管撕裂,温度越低,钢管混凝土柱越早发生破坏,且破坏程度越严重;相较于常温(20℃)工况,0℃、-20℃、-40℃温度工况下,试验钢管混凝土柱水平承载力分别提高3.08%、6.15%、10.08%,初始刚度分别提高16.9%、30.3%、50.0%,而延性系数分别降低8.6%、14.6%、16.9%;环境温度越低,刚度退化速率也越大。温度变化对钢管混凝土柱抗震性能影响显著,高寒地区钢管混凝土结构抗震设计时需考虑环境低温对结构带来的不利影响。 展开更多
关键词 圆钢管混凝土柱 拟静力试验 抗震性能 温度
下载PDF
上一页 1 2 120 下一页 到第