期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Analysis of a Composite Admixture Based on Ready-Mixed Concrete Waste Residuals
1
作者 Jinfa Jiang Long Xiong +1 位作者 Ming Bao Zihan Zhou 《Fluid Dynamics & Materials Processing》 EI 2023年第8期1983-1995,共13页
Reasonable treatment and utilization of waste residuals discharged during the production of ready-mixed concrete is an important problem in the cement industry.In this study,a composite admixture was prepared by using... Reasonable treatment and utilization of waste residuals discharged during the production of ready-mixed concrete is an important problem in the cement industry.In this study,a composite admixture was prepared by using ready-mixed concrete waste residuals,furnace slag,and water granulated slag.The grinding characteristics of such material were investigated.Moreover,the effect of such admixture on cement hydration and pore structure was analyzed by X-ray diffraction,thermogravimetric-differential scanning calorimetry,scanning electron microcopy and mercury intrusion porosimetry.As shown by the results:The grinding characteristics of the waste residuals can be improved significantly by mixing them with furnace slag and water granulated slag.Furthermore,the composite admixture does not change the composition of hydration products;rather it contributes to refine the pore structure of the matrix,thus improving the mechanical properties of these cement-based materials. 展开更多
关键词 Waste residue of ready-mixed concrete station ready mixed concrete composite admixture ACTIVITY MICROSTRUCTURE
下载PDF
A Simple Mix Proportion Design Method Based on Frost Durability for Recycled High Performance Concrete Using Fully Coarse Recycled Aggregate 被引量:2
2
作者 王新杰 LIU Wenying +2 位作者 WEI Da 朱平华 胡坤 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2017年第5期1119-1124,共6页
Durability design of recycled high performance concrete(RHPC) is fundamental for improving the use rate and level of concrete waste as coarse recycled aggregate(CRA). We discussed a frostdurability-based mix propo... Durability design of recycled high performance concrete(RHPC) is fundamental for improving the use rate and level of concrete waste as coarse recycled aggregate(CRA). We discussed a frostdurability-based mix proportion design method for RHPC using 100 % CRA and natural sand. Five groups of RHPC mixes with five strength grades(40, 50, 60, 70 and 80 MPa) were produced using CRA with four quality classes, and their workability, 28 d compressive strengths and frost resistances(measured by the compressive strength loss ratio and the relative dynamic modulus of elasticity) were tested. Relationships between the 28 d compressive strength, the frost resistance and the CRA quality characteristic parameter, water absorption, were then developed. The criterion of a CRA maximum water absorption limit value for RHPC was suggested, independent of its source and quality class. The results show that all RHPC mixes achieve the expected target workability, strength, and frost durability. The research results demonstrate that the application of the proposed method does not require trial testing prior to use. 展开更多
关键词 recycled high performance concrete mix proportion design frost durability compressive strength water absorption
下载PDF
Mechanical Properties and ITZ Microstructure of Recycled Aggregate Concrete Using Carbonated Recycled Coarse Aggregate 被引量:6
3
作者 伍君勇 张云升 +2 位作者 ZHU Pinghua FENG Jincai 胡坤 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2018年第3期648-653,共6页
The effect of carbonation treatment and mixing method on the mechanical properties and interfacial transition zone(ITZ) properties of recycled aggregate concrete(RAC) was investigated. Properties of recycled concr... The effect of carbonation treatment and mixing method on the mechanical properties and interfacial transition zone(ITZ) properties of recycled aggregate concrete(RAC) was investigated. Properties of recycled concrete aggregate(RCA) were tested firstly. Then, five types of concretes were made and slump of fresh concrete was measured immediately after mixing. Compressive strength and splitting tensile strength of hardened concrete were measured at 28 d. Meanwhile, the microstructure of RAC was analyzed by backscattered electron(BSE) image. It was found that the water absorption ratio of carbonated recycled concrete aggregate(CRCA) was much lower when compared to the untreated RCA. Comparatively, the apparent density of CRCA was not significantly modified. The concrete strength results indicate that the mix CRAC-2 prepared with CRCA by adopting two-stage mixing approach shows the highest compressive strength value compared to the other mixes. The microstructural analysis demonstrate that the mix CRAC-2 has a much denser old ITZ than the untreated RAC because of the chemical reaction between CO2 and the hydration products of RCA. This study confirms that the ITZ microstructure of RAC can be efficiently modified by carbonation treatment of RCA and encourages broadening the application of construction and demolition wastes. 展开更多
关键词 recycled aggregate concrete compressive strength interfacial transition zone carbonation treatment two-stage mixing approach back scattered electron
下载PDF
Seepage Mitigation in Hydropower Dams by Optimization in Roller Compacted Concrete Interlayer (Monoliths) Joint Bonding Technology
4
作者 Junjie Jin Qingguo Zhou +1 位作者 Yuanguang Liu Shuncai Ning 《Open Journal of Civil Engineering》 2022年第1期139-151,共13页
Roller Compacted Concrete (RCC) has gained favorable recognition in hydropower and water resource dam construction. With optimization in construction technology and materials used for RCC Dams, cost is no longer a maj... Roller Compacted Concrete (RCC) has gained favorable recognition in hydropower and water resource dam construction. With optimization in construction technology and materials used for RCC Dams, cost is no longer a major disadvantage as compared to environmental impact, that is, wildlife habitat disruption. In as much as it has become optimal for investment in hydropower dam construction, the scourge for dam failure is still eminent, which is as a result of excessive seepage compromising the integrity of the mechanical properties of the dam. The aim of the paper is to highlight successful application methods in joint bonding to avoid excessive seepage and reduce the autogenous healing to a few years of operation. In view of optimization, this paper presents a comprehensive study on the influences of interlayer joints bonding quality from RCC mix performances and how it consolidates the RCC layers to withstand the shear strength along the interface, especially on the high dams. The case study is the RCC dam at the 750 MW Kafue Gorge Lower Hydropower Station. The scope of the study reviews the joint type judged by Modified Maturity Factor (MMF) with joint surface long time exposed in regions with dry and high temperature, technical measures of layer bonding quality control under condition of long time joint surface exposure, effects of joints shear strength and impermeability of the RCC layers when under the conditions of plastic and elasticity. The subtle observations made during the dam construction phases were with respect to the optimal use of materials in relation to RCC mix designs and the basis for equipment calibration for monitoring important data that can be referenced during analysis of shear forces acting on the RCC dam over time. 展开更多
关键词 SEEPAGE Roller Compacted concrete (RCC) Mix RCC Joint Exposure Time Modified Maturity Factor (MMF) Dry and High Temperature Area RCC Joint Bonding Quality Control Measures IMPERMEABILITY Shear Forces
下载PDF
Performance of Sacrificial Anodes in Reinforced Concrete
5
作者 TU L Q DONG C +3 位作者 WANG C J ZHANG G Z LEI Y F SHUI Z H 《武汉理工大学学报》 CAS CSCD 北大核心 2010年第17期165-169,共5页
The electrochemical performance of the anodes was measured in the reinforced concrete test block in artificial sea water. Their chemical composition,metallographic structure and surface morphology were analyzed. It wa... The electrochemical performance of the anodes was measured in the reinforced concrete test block in artificial sea water. Their chemical composition,metallographic structure and surface morphology were analyzed. It was found that concrete mix proportion and the covering layer thickness had an impact on the performance of sacrificial anodes. The thermal-sprayed zinc alloy anodes had a more negative corrosion potential and larger galvanic current than metallurgy ones in the same conditions. They had similar chemical composition. But metallographic structure showed that the structure of thermal-sprayed zinc alloy anodes was a loose porous. This structure had the catalytic effect on the andes electrochemical reactions and made the anodes the electrochemical exchange current density increase and the corrosion potential move to negative direction. 展开更多
关键词 sacrificial anode reinforced concrete concrete mix proportion thermal-sprayed anodes electrochemical performance