This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current te...This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate.展开更多
The work’s objective is to analyze the influence of the saturation temperature of the R134a refrigerant on the thermal performance of a shell and tube type condenser, with water and aluminum oxide (Al<sub>2<...The work’s objective is to analyze the influence of the saturation temperature of the R134a refrigerant on the thermal performance of a shell and tube type condenser, with water and aluminum oxide (Al<sub>2</sub>O<sub>3</sub>) nanoparticles flowing into the tube. For analysis, the heat exchanger is subdivided into three regions: subcooled liquid, saturated steam, and superheated steam. The shell and tube heat exchanger assumed as the basis for the study has 36 tubes, with rows of 4 tubes in line and three passes into the tube in each region. The parameters used to analyze the performance are efficiency and effectiveness, through variations of quantities such as saturation temperature, the nanofluid’s mass flow rate, fraction in the nanoparticles’ volume, and the number of passes in the tube in each region of the heat exchanger. The obtained results demonstrate that the efficiency is relatively high in all the analyzed situations. In each saturation temperature, the effectiveness can be increased by introducing fractions of nanoparticles in the water or increasing the number of passes in the tube.展开更多
A theoretical study has been made to optimize the fin geometry of a horizontal finned tube which is to be used for condensers that handle the vapor load of a liquid phase change cooling module.Systematic numerical cal...A theoretical study has been made to optimize the fin geometry of a horizontal finned tube which is to be used for condensers that handle the vapor load of a liquid phase change cooling module.Systematic numerical calcu- lations of the vapor to coolant heat transfer have been performed for parametric values of fin height,fin spacing, vertical bundle depth and tubeside heat transfer coefficient.Three dielectric fluids (R-113,FC-72,and FC-87) at atmospheric pressure were selected as the working fluids.For a single tube with optimized fin geometry,the average heat flux increased in the order of FC-87,R-113 and FC-72.Both the optimum fin height and optimum fin spacing increased with increasing vertical bundle depth.展开更多
文摘This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate.
文摘The work’s objective is to analyze the influence of the saturation temperature of the R134a refrigerant on the thermal performance of a shell and tube type condenser, with water and aluminum oxide (Al<sub>2</sub>O<sub>3</sub>) nanoparticles flowing into the tube. For analysis, the heat exchanger is subdivided into three regions: subcooled liquid, saturated steam, and superheated steam. The shell and tube heat exchanger assumed as the basis for the study has 36 tubes, with rows of 4 tubes in line and three passes into the tube in each region. The parameters used to analyze the performance are efficiency and effectiveness, through variations of quantities such as saturation temperature, the nanofluid’s mass flow rate, fraction in the nanoparticles’ volume, and the number of passes in the tube in each region of the heat exchanger. The obtained results demonstrate that the efficiency is relatively high in all the analyzed situations. In each saturation temperature, the effectiveness can be increased by introducing fractions of nanoparticles in the water or increasing the number of passes in the tube.
文摘A theoretical study has been made to optimize the fin geometry of a horizontal finned tube which is to be used for condensers that handle the vapor load of a liquid phase change cooling module.Systematic numerical calcu- lations of the vapor to coolant heat transfer have been performed for parametric values of fin height,fin spacing, vertical bundle depth and tubeside heat transfer coefficient.Three dielectric fluids (R-113,FC-72,and FC-87) at atmospheric pressure were selected as the working fluids.For a single tube with optimized fin geometry,the average heat flux increased in the order of FC-87,R-113 and FC-72.Both the optimum fin height and optimum fin spacing increased with increasing vertical bundle depth.