For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT ...For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8 mm, 2.4 ± 2.1 mm, and 3.8 ± 2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5 ± 1.1 mm, 0.3 ± 0.8 mm, and 1.8 ± 2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets.展开更多
In this study,the influence of respiratory motion on Cone Beam CT (CBCT) image quality was investigated by a motion simulating platform,an image quality phantom,and a kV X-ray CBCT.A total of 21 motion states in the s...In this study,the influence of respiratory motion on Cone Beam CT (CBCT) image quality was investigated by a motion simulating platform,an image quality phantom,and a kV X-ray CBCT.A total of 21 motion states in the superior-inferior direction and the anterior-posterior direction,separately or together,was simulated by considering different respiration amplitudes,periods and hysteresis.The influence of motion on CBCT image quality was evaluated with the quality indexes of low contrast visibility,geometric accuracy,spatial resolution and uniformity of CT values.The results showed that the quality indexes were affected by the motion more prominently in AP direction than in SI direction,and the image quality was affected by the respiration amplitude more prominently than the respiration period and the hysteresis.The CBCT image quality and its characteristics influenced by the respiration motion,and may be exploited in finding solutions.展开更多
Purpose: To prospectively analyze the inter-fractional motion of the prostate in patients with prostate cancer treated with intensity-modulated radiation therapy (IMRT) using image-guided radiotherapy (IGRT) with dail...Purpose: To prospectively analyze the inter-fractional motion of the prostate in patients with prostate cancer treated with intensity-modulated radiation therapy (IMRT) using image-guided radiotherapy (IGRT) with daily cone-beam computed tomography (CBCT) as part of a rescan protocol for large offset, and to evaluate the efficacy of our protocol. Materials and Methods: Eligible patients were treated with the following protocol: 1) magnesium oxide and dimethylpolysiloxane were administered to ensure that patients had regular bowel movements;2) the patients were instructed to have an appropriately distended bladder during the planning CT and daily irradiation;3) the daily CBCT image was fused with the planning CT image using the prostate outline;and 4) if large offset was recognized, a rescan CBCT image was obtained after appropriate countermeasures, such as the discharge of gas and defecation, and re-registration was performed. Three shifts for the inter-fractional motion of the prostate were analyzed, in the fractions which needed the CBCT rescan;the displacement data after the final rescan were used. Results: Sixty-one patients were eligible, and a total of 2302 fractions were available for the analysis. Rescans of the CBCT for large offset were performed in 113 (5%) of the 2302 fractions. After the first rescan, the large offset was resolved in 106 (94%) of the 113 fractions. Excessive rectal gas was the reason for the large offset in 94 (83%) of the 113 fractions. The total mean and standard deviation of the inter-fractional motion of the prostate in the AP, LR, and SI directions were 1.1 ± 2.4, -0.1 ± 2.3, and 0.7 ± 3.0 mm, respectively. Conclusion: Large offset was recognized in 5% of all fractions. Daily CBCT with our rescan protocol could resolve the large offset, which was mainly caused by excessive rectal gas, and it may therefore be promising to reduce the inter-fractional motion of the prostate.展开更多
Purpose: To determine whether motion perception of short-wavelength sensitive(SWS)cones is capable of predicting primary open angle glaucoma (POAG) optic neuropathy.Methods: Motion perceptions of SWS cones were isolat...Purpose: To determine whether motion perception of short-wavelength sensitive(SWS)cones is capable of predicting primary open angle glaucoma (POAG) optic neuropathy.Methods: Motion perceptions of SWS cones were isolated by Blue random dot stimulusdisplayed on the Yellow background, then the detecting displacement threshold of motionperception from SWS cone in POAG was measured, and compared with the age-matchednormal group.Results: The detecting displacement thresholds of motion perception from SWS cones in8 sites of 15 degrees were all elevated in POAG compared with the normal group.Conclusion: These findings suggest that motion perception of SWS cones may revealpreclinical visual nerve damage in early POAG.展开更多
A nonlinear mathematic model taking the nutation and precession angles as variables for the coning motion of projectile was established according to a short period moment projection of the spining projectile. By intro...A nonlinear mathematic model taking the nutation and precession angles as variables for the coning motion of projectile was established according to a short period moment projection of the spining projectile. By introducing the generalized nutation angle and precession angular speed, the model that is difficult to be resolved can be transformed to a resolvable one. The interrelationship between nutation and precession was analyzed based on the linear model, and the stability condition was obtained for the spinning projectile. For the nonlinear model, the effects of the nutation and precession on the limit circle of the projectile's coning motion were investigated, and the analytical relations between the nutation angle and the precession angular speed in the steady coning motion of the spinning projectile were given.展开更多
基于实验室设备自主开发了一套320 kV锥束工业CT成像系统。首先设计了基于运动控制卡的六轴机械扫描平台,并将其与320 kV射线机、平板探测器结合搭建了锥束CT成像系统的硬件。其次,利用平板探测器和运动控制卡的动态链接库开发锥束CT投...基于实验室设备自主开发了一套320 kV锥束工业CT成像系统。首先设计了基于运动控制卡的六轴机械扫描平台,并将其与320 kV射线机、平板探测器结合搭建了锥束CT成像系统的硬件。其次,利用平板探测器和运动控制卡的动态链接库开发锥束CT投影数据采集软件和重建软件,自主开发FDK算法并基于CUDA架构实现FDK算法的GPU加速。最后,采用阻尼器对锥束CT成像系统进行测试。结果表明,整个系统运行稳定,可以获得高质量的CT重建图像,且重建效果与VG STUDIO MAX 3.4软件的重建效果一致。展开更多
Purpose: To investigate the characteristics of interaction between color and motion perception in primary open angle glaucoma (POAG) and measure motion perception of B,G and R cones, thus find a more sensitive method ...Purpose: To investigate the characteristics of interaction between color and motion perception in primary open angle glaucoma (POAG) and measure motion perception of B,G and R cones, thus find a more sensitive method to diagnose the visual nerve damage in POAG. Methods : Motion perceptions of B,G and R cones were isolated by blue , green and red vertical line stimulus displayed on the yellow , purple and blue background respectively, then measured the displacement threshold and flicking threshold of motion perception from each cones in POAG, and compared it with the age-match normals.Results:The displacement threshold and flicking threshold of motion perception from B,G and R cones were all damaged in POAG compared with the normals, and the motion perception of G and B cones was deficits more obviously than the R cones.Conclusion: These findings support the suggestion that color provides an input to human motion perception. Magnocellular and parvocellular pathway may be significandy damaged in POAG,展开更多
The laser gyro is most su it able for building the strap down inertial navigation system (SINS), and its acc uracy of attitude algorithm can enormously affect that of the laser SINS. This p aper develops three improv...The laser gyro is most su it able for building the strap down inertial navigation system (SINS), and its acc uracy of attitude algorithm can enormously affect that of the laser SINS. This p aper develops three improved algorithmal expressions for strap down attitude ut ilizing the angular increment output by the laser gyro from the last two and cur rent updating periods according to the number of gyro samples, and analyses the algorithm error in the classical coning motion. Compared with the conventional algorithms, simulational results show that this improved algorithm has higher precision. A new way to improve the rotation vector algorithms is provided.展开更多
文摘For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8 mm, 2.4 ± 2.1 mm, and 3.8 ± 2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5 ± 1.1 mm, 0.3 ± 0.8 mm, and 1.8 ± 2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets.
基金Supported by National Natural Science Foundation of China(Grant No.10975187)and clinic research grant(No.LC2009B34)from the Cancer Institute
文摘In this study,the influence of respiratory motion on Cone Beam CT (CBCT) image quality was investigated by a motion simulating platform,an image quality phantom,and a kV X-ray CBCT.A total of 21 motion states in the superior-inferior direction and the anterior-posterior direction,separately or together,was simulated by considering different respiration amplitudes,periods and hysteresis.The influence of motion on CBCT image quality was evaluated with the quality indexes of low contrast visibility,geometric accuracy,spatial resolution and uniformity of CT values.The results showed that the quality indexes were affected by the motion more prominently in AP direction than in SI direction,and the image quality was affected by the respiration amplitude more prominently than the respiration period and the hysteresis.The CBCT image quality and its characteristics influenced by the respiration motion,and may be exploited in finding solutions.
文摘Purpose: To prospectively analyze the inter-fractional motion of the prostate in patients with prostate cancer treated with intensity-modulated radiation therapy (IMRT) using image-guided radiotherapy (IGRT) with daily cone-beam computed tomography (CBCT) as part of a rescan protocol for large offset, and to evaluate the efficacy of our protocol. Materials and Methods: Eligible patients were treated with the following protocol: 1) magnesium oxide and dimethylpolysiloxane were administered to ensure that patients had regular bowel movements;2) the patients were instructed to have an appropriately distended bladder during the planning CT and daily irradiation;3) the daily CBCT image was fused with the planning CT image using the prostate outline;and 4) if large offset was recognized, a rescan CBCT image was obtained after appropriate countermeasures, such as the discharge of gas and defecation, and re-registration was performed. Three shifts for the inter-fractional motion of the prostate were analyzed, in the fractions which needed the CBCT rescan;the displacement data after the final rescan were used. Results: Sixty-one patients were eligible, and a total of 2302 fractions were available for the analysis. Rescans of the CBCT for large offset were performed in 113 (5%) of the 2302 fractions. After the first rescan, the large offset was resolved in 106 (94%) of the 113 fractions. Excessive rectal gas was the reason for the large offset in 94 (83%) of the 113 fractions. The total mean and standard deviation of the inter-fractional motion of the prostate in the AP, LR, and SI directions were 1.1 ± 2.4, -0.1 ± 2.3, and 0.7 ± 3.0 mm, respectively. Conclusion: Large offset was recognized in 5% of all fractions. Daily CBCT with our rescan protocol could resolve the large offset, which was mainly caused by excessive rectal gas, and it may therefore be promising to reduce the inter-fractional motion of the prostate.
文摘Purpose: To determine whether motion perception of short-wavelength sensitive(SWS)cones is capable of predicting primary open angle glaucoma (POAG) optic neuropathy.Methods: Motion perceptions of SWS cones were isolated by Blue random dot stimulusdisplayed on the Yellow background, then the detecting displacement threshold of motionperception from SWS cone in POAG was measured, and compared with the age-matchednormal group.Results: The detecting displacement thresholds of motion perception from SWS cones in8 sites of 15 degrees were all elevated in POAG compared with the normal group.Conclusion: These findings suggest that motion perception of SWS cones may revealpreclinical visual nerve damage in early POAG.
基金Sponsored by the National Science Foundation of China (10972034)
文摘A nonlinear mathematic model taking the nutation and precession angles as variables for the coning motion of projectile was established according to a short period moment projection of the spining projectile. By introducing the generalized nutation angle and precession angular speed, the model that is difficult to be resolved can be transformed to a resolvable one. The interrelationship between nutation and precession was analyzed based on the linear model, and the stability condition was obtained for the spinning projectile. For the nonlinear model, the effects of the nutation and precession on the limit circle of the projectile's coning motion were investigated, and the analytical relations between the nutation angle and the precession angular speed in the steady coning motion of the spinning projectile were given.
文摘基于实验室设备自主开发了一套320 kV锥束工业CT成像系统。首先设计了基于运动控制卡的六轴机械扫描平台,并将其与320 kV射线机、平板探测器结合搭建了锥束CT成像系统的硬件。其次,利用平板探测器和运动控制卡的动态链接库开发锥束CT投影数据采集软件和重建软件,自主开发FDK算法并基于CUDA架构实现FDK算法的GPU加速。最后,采用阻尼器对锥束CT成像系统进行测试。结果表明,整个系统运行稳定,可以获得高质量的CT重建图像,且重建效果与VG STUDIO MAX 3.4软件的重建效果一致。
基金This research was supported by National Nature Science Foundation,NO.39470743
文摘Purpose: To investigate the characteristics of interaction between color and motion perception in primary open angle glaucoma (POAG) and measure motion perception of B,G and R cones, thus find a more sensitive method to diagnose the visual nerve damage in POAG. Methods : Motion perceptions of B,G and R cones were isolated by blue , green and red vertical line stimulus displayed on the yellow , purple and blue background respectively, then measured the displacement threshold and flicking threshold of motion perception from each cones in POAG, and compared it with the age-match normals.Results:The displacement threshold and flicking threshold of motion perception from B,G and R cones were all damaged in POAG compared with the normals, and the motion perception of G and B cones was deficits more obviously than the R cones.Conclusion: These findings support the suggestion that color provides an input to human motion perception. Magnocellular and parvocellular pathway may be significandy damaged in POAG,
文摘The laser gyro is most su it able for building the strap down inertial navigation system (SINS), and its acc uracy of attitude algorithm can enormously affect that of the laser SINS. This p aper develops three improved algorithmal expressions for strap down attitude ut ilizing the angular increment output by the laser gyro from the last two and cur rent updating periods according to the number of gyro samples, and analyses the algorithm error in the classical coning motion. Compared with the conventional algorithms, simulational results show that this improved algorithm has higher precision. A new way to improve the rotation vector algorithms is provided.