An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/...An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/3-scale interior beam-column subassemblies,one monolithic concrete specimen and five precast concrete specimens were tested.One precast specimen was a simple connection for a gravity load resistant design.Other precast specimens were developed with different attributes to improve their seismic performance.The test results showed that the performance of the monolithic specimen M1 represented ductile seismic behavior.Failure of columns and joints could be prevented,and the failure of the frame occurred at the flexural plastic hinge formation at the beam ends,close to the column faces.For the precast specimens,the splitting crack along the longitudinal lapped splice was a major failure.The precast P5 specimen with double steel T-section inserts showed better seismic performance compared to the other precast models.However,the dowel bars connected to the steel inserts were too short to develop a bond.The design of the precast concrete beams with lap splice is needed for longer lap lengths and should be done at the beam mid span or at the low flexural stress region.展开更多
Beam-column or beam-wall connections are an important problem in high-rise buildings. In this study, based on the analysis of an example structure, an analytical model for design of the semi-rigid connections between ...Beam-column or beam-wall connections are an important problem in high-rise buildings. In this study, based on the analysis of an example structure, an analytical model for design of the semi-rigid connections between steel beams and RC walls in high-rise hybrid buildings is proposed. Also, the mechanical characteristics of these connections subjected to low-reversed cyclic loading are investigated through comparison of experimental results from three semi-rigid connections and two rigid connections. Moreover, some latent problems for design of these connections as well as the corresponding solutions are discussed. The results from the experiments and analyses indicate that semi-rigid connections exhibit satisfactory capacity and seismic performance, and the proposed design can be used in practice.展开更多
In the past, brittle fracture of steel structure was reported rarely under earthquake. However, recent earthquakes, especially Northridge Earthquake (USA) and Hyogoken Nanbu earthquake (Japan), astonished engineers i...In the past, brittle fracture of steel structure was reported rarely under earthquake. However, recent earthquakes, especially Northridge Earthquake (USA) and Hyogoken Nanbu earthquake (Japan), astonished engineers in the field of construction. The experience from recent earthquakes of USA and Japan shows that brittle fracture of welded steel structure always starts from high stress zone with welded crack [1~5] . As backing bar for grooved weld on beam flange exists, artificial crack is formed because of lack of fusion at the root of flange weld. In this paper stress distribution of connection is computed with FEM, and stress concentration at the root of flange weld is also analyzed. Stress intensity factors (SIFs), K I, at the root of flange weld are computed in the method of fracture mechanics. The computation shows that stress intensity factor on bottom flange weld is obviously higher than that on top flange weld. It is proved by the fact that brittle fracture is liable to start at the root of bottom flange weld on actual earthquake [1,4] . Finally measures are brought forward to avoid fracture of weld structure against earthquake.展开更多
Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and us...Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections.展开更多
The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real condition...The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real conditions,a beam⁃through⁃type beam⁃column connection is proposed.Two 1/2⁃scaled connection specimens were tested and three⁃dimensional finite element models of the beam⁃column connection were set up.The longitudinal reinforcements,concrete beam,and column were simulated by link and solid elements,respectively.The influences of the parameters such as expansion ratio,location of web opening,and original height of steel beam were studied.The results show that connections possessed high initial rigidity.The expansion ratio of steel beam showed more important influence on the connection’s ultimate bearing capacity.For the connection models with steel beam expansion ratio of 1.4,the maximum increment of the ultimate bearing capacity of the connection could reach 28%.In order to prevent the local buckling failure of steel beam from occurring near web opening,the expansion ratio of steel beam should not be greater than 1.3.展开更多
In this paper, a finite element method is developed to numericallyevaluate the shear coefficient of Timoshenko's beam with multiplyconnected cross section. With focus on analyzing shear stressesdistributed at the ...In this paper, a finite element method is developed to numericallyevaluate the shear coefficient of Timoshenko's beam with multiplyconnected cross section. With focus on analyzing shear stressesdistributed at the neutral axis of the beam, an improved definitionof the shear coeffi- cient is presented. Based on this definition, aGalerkin-type finite element formulation is proposed to analyze theshear stresses and shear deflections. Numerical solutions of theexamples for some typical cross-sections are compared with thetheoretical results. The shear coefficient of tower sections of theTsing Ma Bridge is calculated by use of the proposed approach, sothat the finite element modeling of The bridge can be developed withthe accurate values of the sectional properties.展开更多
In most framed structures anticipated deformations in accordance with current codes fall into acceptable limit states, whereas they go through substantial residual deformations in the aftermath of severe ground motion...In most framed structures anticipated deformations in accordance with current codes fall into acceptable limit states, whereas they go through substantial residual deformations in the aftermath of severe ground motions. These structures seem unsafe to occupants since static imminent instability in the immediate post-earthquake may be occurred. Moreover, rehabilitation costs of extensive residual deformations are not usually reasonable. Apparently, there is a lack of detailed knowledge related to reducing residual drift techniques when code-based seismic design is considered. In this paper, reduced beam section connections as a positive approach are taken action to mitigate the huge amount of residual drifts which are greatly amplified by P-Δ effects. To demonstrate the efficacy of RBS, a sixteen-story moment resisting frame is analyzed based on a suite of 8 single-component near field records which have been scaled according to the code provisions. The results are then processed to assess the effects of RBS detailing on drift profile, maximum drift, and residual drift. Besides, a special emphasis is given to estimate overall trend towards drift accumulation in each story in the presence of RBS assembly. A main conclusion is that using this connection predominantly alleviates the adverse effects of P-Δ on amplifying residual drifts.展开更多
Wood beam-column frame is a popular structural system in United States and in ancient China. Chinese wood beam-column frame structures showed better seismic resistance properties than the US ones.The tenon joint is on...Wood beam-column frame is a popular structural system in United States and in ancient China. Chinese wood beam-column frame structures showed better seismic resistance properties than the US ones.The tenon joint is one of the reasons.This study performed monotonic and cyclic pushover tests to understand the behavior of Chinese tenon joints versus the behavior of the commonly used US wood beam-column connections. The test results indicate that the typical US wood beam-column connection is very strong under monotonic loads.The ancient Chinese tenon joint has the best behavior under cyclic loads.展开更多
Ten full-scale steel beam-to-column moment connections used in moment-resisting frames (MRFs) were tested to study the failure process, failure mode, strength and plastic rotation capacity. The specimens include one...Ten full-scale steel beam-to-column moment connections used in moment-resisting frames (MRFs) were tested to study the failure process, failure mode, strength and plastic rotation capacity. The specimens include one traditional welded flange-bolted web connection, one traditional fully welded connection, four beam flange strengthened connections, three beam flange weakened connections, and one through-diaphragm connection. The test results show that the connections with flange cover plates or with partly cut beam flanges satisfy the beam plastic rotation demand for ductile MRFs. From the measured stress profiles along the beam flange and beam web depth, the mechanics of brittle fracture at the end of the beam is discussed. Design recommendations for steel beam-to-column moment connections are proposed.展开更多
文摘An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/3-scale interior beam-column subassemblies,one monolithic concrete specimen and five precast concrete specimens were tested.One precast specimen was a simple connection for a gravity load resistant design.Other precast specimens were developed with different attributes to improve their seismic performance.The test results showed that the performance of the monolithic specimen M1 represented ductile seismic behavior.Failure of columns and joints could be prevented,and the failure of the frame occurred at the flexural plastic hinge formation at the beam ends,close to the column faces.For the precast specimens,the splitting crack along the longitudinal lapped splice was a major failure.The precast P5 specimen with double steel T-section inserts showed better seismic performance compared to the other precast models.However,the dowel bars connected to the steel inserts were too short to develop a bond.The design of the precast concrete beams with lap splice is needed for longer lap lengths and should be done at the beam mid span or at the low flexural stress region.
基金National Natural Science Foundation of China Under Grant No. 50025821
文摘Beam-column or beam-wall connections are an important problem in high-rise buildings. In this study, based on the analysis of an example structure, an analytical model for design of the semi-rigid connections between steel beams and RC walls in high-rise hybrid buildings is proposed. Also, the mechanical characteristics of these connections subjected to low-reversed cyclic loading are investigated through comparison of experimental results from three semi-rigid connections and two rigid connections. Moreover, some latent problems for design of these connections as well as the corresponding solutions are discussed. The results from the experiments and analyses indicate that semi-rigid connections exhibit satisfactory capacity and seismic performance, and the proposed design can be used in practice.
文摘In the past, brittle fracture of steel structure was reported rarely under earthquake. However, recent earthquakes, especially Northridge Earthquake (USA) and Hyogoken Nanbu earthquake (Japan), astonished engineers in the field of construction. The experience from recent earthquakes of USA and Japan shows that brittle fracture of welded steel structure always starts from high stress zone with welded crack [1~5] . As backing bar for grooved weld on beam flange exists, artificial crack is formed because of lack of fusion at the root of flange weld. In this paper stress distribution of connection is computed with FEM, and stress concentration at the root of flange weld is also analyzed. Stress intensity factors (SIFs), K I, at the root of flange weld are computed in the method of fracture mechanics. The computation shows that stress intensity factor on bottom flange weld is obviously higher than that on top flange weld. It is proved by the fact that brittle fracture is liable to start at the root of bottom flange weld on actual earthquake [1,4] . Finally measures are brought forward to avoid fracture of weld structure against earthquake.
基金Supported by National Natural Science Foundation of China(No.51268054)Natural Science Foundation of Tianjin(No.13JCQNJC07300)the foundation of Key Laboratory of Coast Civil Structure Safety(Tianjin University),Ministry of Education of China(No.2011-1)
文摘Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections.
基金Sponsored by the Open Subject of the State Key Laboratory of Subtropical Building Science(Grant No.2018ZB29).
文摘The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real conditions,a beam⁃through⁃type beam⁃column connection is proposed.Two 1/2⁃scaled connection specimens were tested and three⁃dimensional finite element models of the beam⁃column connection were set up.The longitudinal reinforcements,concrete beam,and column were simulated by link and solid elements,respectively.The influences of the parameters such as expansion ratio,location of web opening,and original height of steel beam were studied.The results show that connections possessed high initial rigidity.The expansion ratio of steel beam showed more important influence on the connection’s ultimate bearing capacity.For the connection models with steel beam expansion ratio of 1.4,the maximum increment of the ultimate bearing capacity of the connection could reach 28%.In order to prevent the local buckling failure of steel beam from occurring near web opening,the expansion ratio of steel beam should not be greater than 1.3.
文摘In this paper, a finite element method is developed to numericallyevaluate the shear coefficient of Timoshenko's beam with multiplyconnected cross section. With focus on analyzing shear stressesdistributed at the neutral axis of the beam, an improved definitionof the shear coeffi- cient is presented. Based on this definition, aGalerkin-type finite element formulation is proposed to analyze theshear stresses and shear deflections. Numerical solutions of theexamples for some typical cross-sections are compared with thetheoretical results. The shear coefficient of tower sections of theTsing Ma Bridge is calculated by use of the proposed approach, sothat the finite element modeling of The bridge can be developed withthe accurate values of the sectional properties.
文摘In most framed structures anticipated deformations in accordance with current codes fall into acceptable limit states, whereas they go through substantial residual deformations in the aftermath of severe ground motions. These structures seem unsafe to occupants since static imminent instability in the immediate post-earthquake may be occurred. Moreover, rehabilitation costs of extensive residual deformations are not usually reasonable. Apparently, there is a lack of detailed knowledge related to reducing residual drift techniques when code-based seismic design is considered. In this paper, reduced beam section connections as a positive approach are taken action to mitigate the huge amount of residual drifts which are greatly amplified by P-Δ effects. To demonstrate the efficacy of RBS, a sixteen-story moment resisting frame is analyzed based on a suite of 8 single-component near field records which have been scaled according to the code provisions. The results are then processed to assess the effects of RBS detailing on drift profile, maximum drift, and residual drift. Besides, a special emphasis is given to estimate overall trend towards drift accumulation in each story in the presence of RBS assembly. A main conclusion is that using this connection predominantly alleviates the adverse effects of P-Δ on amplifying residual drifts.
文摘Wood beam-column frame is a popular structural system in United States and in ancient China. Chinese wood beam-column frame structures showed better seismic resistance properties than the US ones.The tenon joint is one of the reasons.This study performed monotonic and cyclic pushover tests to understand the behavior of Chinese tenon joints versus the behavior of the commonly used US wood beam-column connections. The test results indicate that the typical US wood beam-column connection is very strong under monotonic loads.The ancient Chinese tenon joint has the best behavior under cyclic loads.
文摘Ten full-scale steel beam-to-column moment connections used in moment-resisting frames (MRFs) were tested to study the failure process, failure mode, strength and plastic rotation capacity. The specimens include one traditional welded flange-bolted web connection, one traditional fully welded connection, four beam flange strengthened connections, three beam flange weakened connections, and one through-diaphragm connection. The test results show that the connections with flange cover plates or with partly cut beam flanges satisfy the beam plastic rotation demand for ductile MRFs. From the measured stress profiles along the beam flange and beam web depth, the mechanics of brittle fracture at the end of the beam is discussed. Design recommendations for steel beam-to-column moment connections are proposed.