期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Nonlinear Behavior of Reinforced Concrete Slit Shear Walls under Seismic Actions *
1
作者 戴航 陈忠范 +1 位作者 关国雄 张佑启 《Journal of Southeast University(English Edition)》 EI CAS 1998年第1期86-92,共7页
A reinforced concrete slit shear wall is a new breed of earthquake resistant structure recently proposed by the authors. In this paper, the seismic responses of the slit shear walls under the shake of earthquake exci... A reinforced concrete slit shear wall is a new breed of earthquake resistant structure recently proposed by the authors. In this paper, the seismic responses of the slit shear walls under the shake of earthquake excitation have been dealt with. Based on a simplified structural model, which is shown to have a sufficient accuracy for the real slit shear wall structure, the analysis focuses on the influence of nonlinear behavior of the connecting beams between the slits on the dynamic performance of the whole slit shear wall structure. It has been found that the yielding of connecting beams in a slit shear wall can provide significant improvement in reducing the structural responses, and by choosing an appropriate strength value for the connecting beams, it is possible to optimize the seismic response of the slit shear wall. 展开更多
关键词 seismic response slit shear wall reinforced concrete connecting beam
下载PDF
Application of Modern Wood Product Glulam in Timber Frame With Tenon- Mortise Joints and Its Structural Behavior 被引量:2
2
作者 Guofang Wu Yong Zhong +1 位作者 Yingchun Gong Haiqing Ren 《Journal of Renewable Materials》 SCIE 2019年第5期451-461,共11页
Tenon-mortise joint is widely used in traditional timber structures around the world.This paper summarizes the results of an experimental study of the structural behavior of tenon-mortise joints made with glulam and C... Tenon-mortise joint is widely used in traditional timber structures around the world.This paper summarizes the results of an experimental study of the structural behavior of tenon-mortise joints made with glulam and CNC technology instead of traditional material and manual work.30 full-scale tenonmortise joints were manufactured and tested under monotonic loading,and the effects of dimension,shape,processing error and adhesive were evaluated.It was found that the round rectangular shaped tenon-mortise joints were comparable with traditional joints in terms of structural performance,but were time and labor saving.The variability of the proposed tenon-mortise joints was lower,which would benefit the design value.Applying adhesive between tenon and mortise increased the average stiffness by 4.3 times and average moment capacity by 27.4%,respectively.The gaps between wood members had little effect on the capacity and stiffness in monotonic bending but may influence the energy dissipation ability in cyclic bending.This study showed the feasibility of combining the traditional joinery method with modern wood products and manufacturing technology,which may promote the application of tenon-mortise joints in modern timber structures. 展开更多
关键词 Tenon-mortise joint moment carrying capacity beam to column connection semi-rigid joint timber structure
下载PDF
Numerical stress analysis of crack at welded beam-to-column connection
3
作者 姚国春 霍立兴 +2 位作者 张玉凤 荆洪阳 杨新岐 《China Welding》 EI CAS 2000年第2期41-46,共6页
In the past, brittle fracture of steel structure was reported rarely under earthquake. However, recent earthquakes, especially Northridge Earthquake (USA) and Hyogoken Nanbu earthquake (Japan), astonished engineers i... In the past, brittle fracture of steel structure was reported rarely under earthquake. However, recent earthquakes, especially Northridge Earthquake (USA) and Hyogoken Nanbu earthquake (Japan), astonished engineers in the field of construction. The experience from recent earthquakes of USA and Japan shows that brittle fracture of welded steel structure always starts from high stress zone with welded crack [1~5] . As backing bar for grooved weld on beam flange exists, artificial crack is formed because of lack of fusion at the root of flange weld. In this paper stress distribution of connection is computed with FEM, and stress concentration at the root of flange weld is also analyzed. Stress intensity factors (SIFs), K I, at the root of flange weld are computed in the method of fracture mechanics. The computation shows that stress intensity factor on bottom flange weld is obviously higher than that on top flange weld. It is proved by the fact that brittle fracture is liable to start at the root of bottom flange weld on actual earthquake [1,4] . Finally measures are brought forward to avoid fracture of weld structure against earthquake. 展开更多
关键词 welded steel structure beam to column connection numerical analysis artificial crack stress intensity factor
下载PDF
Numerical Modeling on Seismic Performance of Castellated Composite Beam⁃Reinforced Concrete Column Connection
4
作者 Hongwei Ma Junjie Wang Yang Wang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2021年第2期62-73,共12页
The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real condition... The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real conditions,a beam⁃through⁃type beam⁃column connection is proposed.Two 1/2⁃scaled connection specimens were tested and three⁃dimensional finite element models of the beam⁃column connection were set up.The longitudinal reinforcements,concrete beam,and column were simulated by link and solid elements,respectively.The influences of the parameters such as expansion ratio,location of web opening,and original height of steel beam were studied.The results show that connections possessed high initial rigidity.The expansion ratio of steel beam showed more important influence on the connection’s ultimate bearing capacity.For the connection models with steel beam expansion ratio of 1.4,the maximum increment of the ultimate bearing capacity of the connection could reach 28%.In order to prevent the local buckling failure of steel beam from occurring near web opening,the expansion ratio of steel beam should not be greater than 1.3. 展开更多
关键词 castellated composite beam beam⁃column connection finite element analysis expansion ratio
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部