Oil-air two-phase flow measurement was investigated with a Venturi and void fraction meters in this work. This paper proposes a new flow rate measurement correlation in which the effect of the velocity ratio between g...Oil-air two-phase flow measurement was investigated with a Venturi and void fraction meters in this work. This paper proposes a new flow rate measurement correlation in which the effect of the velocity ratio between gas and liquid was considered. With the pressure drop across the Venturi and the void fraction that was measured by electrical capacitance tomography apparatus, both mixture flow rate and oil flow rate could be obtained by the correlation. Experiments included bubble-, slug-, wave and annular flow with the void fraction ranging from 15% to 83%, the oil flow rate ranging from 0.97 kg/s to 1.78 kg/s, the gas flow rate ranging up to 0.018 kg/s and quality ranging nearly up to 2.0%. The root-mean-square errors of mixture mass flow rate and that of oil mass flow rate were less than 5%. Furthermore, coefficients of the correlation were modified based on flow regimes, with the results showing reduced root-mean-square errors.展开更多
The effects of feed gas flow rate and operating current on the electrical characteristics and dynamic behavior of a rotating gliding arc (RGA) plasma codriven by a magnetic field and tangential flow were investigate...The effects of feed gas flow rate and operating current on the electrical characteristics and dynamic behavior of a rotating gliding arc (RGA) plasma codriven by a magnetic field and tangential flow were investigated.The operating current has been shown to significantly affect the time-resolved voltage waveforms of the discharge,particularly at flow rate =21 min^-1.When the current was lower than 140 mA,sinusoidal waveforms with regular variation periods of 13.5-17.0 ms can be observed (flow rate =21 min^-1).The restrike mode characterized by serial sudden drops of voltage appeared under all studied conditions.Increasing the flow rate from 8 to 121 min^-1 (at the same current) led to a shift of arc rotation mode which would then result in a significant drop of discharge voltage (around 120-200 V).For a given flow rate,the reduction of current resulted in a nearly linear increase of voltage.展开更多
Charge is a fundamental physical property of matter that is responsible for its interactions with electromagnetic fields. The real nature and the essence of charge are unknown. In this paper, a new theory is presented...Charge is a fundamental physical property of matter that is responsible for its interactions with electromagnetic fields. The real nature and the essence of charge are unknown. In this paper, a new theory is presented to describe the nature and the essence of electric charge is formulated based on the vortex model of the electron which has a finite size and has an irrotational vortex structure. This theory and the vortex model of the electron enables us, for the first time, to describe the origin of bivalency, stability, quantization, equality of the absolute values of the bivalent charges, to derive a simple formulation to calculate the electric charge based on hydrodynamics without the use any constant. The difference between negative and positive charge, is revealed and the charged particles interactions are described. The electric charge is an expression of accelerated spherical mass per area reduced by the stiffness of the vacuum which has the units <i>ε</i><sub>0</sub> ML<sup>3</sup>/T<sup>2</sup>. The calculated results based on these equations comply accurately with the experimental results.展开更多
In this work, a numerical study for designing a new kind of MHD (Magneto-Hydrn-Dynamic) pumps is presented. This technique makes a compromise between electrolysis prevention and high flow rate performance. This tech...In this work, a numerical study for designing a new kind of MHD (Magneto-Hydrn-Dynamic) pumps is presented. This technique makes a compromise between electrolysis prevention and high flow rate performance. This technique should eliminate electrolytic bubble generation, electrodes wear and fluid propriety modification. All these side phenomena are prevented by considering isolated electrodes. The numerical presented results in this paper demonstrate that continuous MHD pumping is possible with isolated electrodes. The MHD excitation combines a high frequency altering current with a low frequency altering magnetic field. In order to validate our results, two independent theoretical methods for computing flow rate are followed. The two presented independent approaches show that high flow rate is possible even with isolated electrodes. To overcome the problem of dimensioning this kind of pumps, a generic numerical analysis is proposed. Hence, the pump performances as functions of the external parameter are studied and tools to calculate for a given fluid and the optimal high frequency regime are provided.展开更多
The aim of this work is to investigate the dependence of Zn S thin films structural and optical properties with the solution flow rate during the deposition using an ultrasonic spray method. The solution flow rate ran...The aim of this work is to investigate the dependence of Zn S thin films structural and optical properties with the solution flow rate during the deposition using an ultrasonic spray method. The solution flow rate ranged from 10 to 50 m L/h and the substrate temperature was maintained at 450 °C. The effect of the solution flow rate on the properties of Zn S thin films was investigated by X-ray diffraction(XRD), scanning electron microscopy(SEM), optical transmittance spectroscopy(UV–V) and the four-point method. The X-ray diffraction analysis showed that the deposited material was pure zinc sulphide, it has a cubic sphalerite structure with preferential orientation along the(111) direction. The grain size values were calculated and found to be between 38 to 82 nm.SEM analysis revealed that the deposited thin films have good adherence to the substrate surfaces, are homogeneous and have high density. The average transmission of all films is up more than 65% in the range wavelength from 200 to 1100 nm and their band gap energy values were found between 3.5–3.92 e V. The obtained film thickness varies from 390 to 1040 nm. Moreover, the electric resistivity of the deposited films increases with the increasing of the solution flow rate between 3.51 × 10^5 and 11 × 10^5 Ω·cm.展开更多
基金Project (No. 2001AA413210) supported by the Hi-Tech Researchand Development Program (863) of China
文摘Oil-air two-phase flow measurement was investigated with a Venturi and void fraction meters in this work. This paper proposes a new flow rate measurement correlation in which the effect of the velocity ratio between gas and liquid was considered. With the pressure drop across the Venturi and the void fraction that was measured by electrical capacitance tomography apparatus, both mixture flow rate and oil flow rate could be obtained by the correlation. Experiments included bubble-, slug-, wave and annular flow with the void fraction ranging from 15% to 83%, the oil flow rate ranging from 0.97 kg/s to 1.78 kg/s, the gas flow rate ranging up to 0.018 kg/s and quality ranging nearly up to 2.0%. The root-mean-square errors of mixture mass flow rate and that of oil mass flow rate were less than 5%. Furthermore, coefficients of the correlation were modified based on flow regimes, with the results showing reduced root-mean-square errors.
基金supported by National Natural Science Foundation of China(51576174)
文摘The effects of feed gas flow rate and operating current on the electrical characteristics and dynamic behavior of a rotating gliding arc (RGA) plasma codriven by a magnetic field and tangential flow were investigated.The operating current has been shown to significantly affect the time-resolved voltage waveforms of the discharge,particularly at flow rate =21 min^-1.When the current was lower than 140 mA,sinusoidal waveforms with regular variation periods of 13.5-17.0 ms can be observed (flow rate =21 min^-1).The restrike mode characterized by serial sudden drops of voltage appeared under all studied conditions.Increasing the flow rate from 8 to 121 min^-1 (at the same current) led to a shift of arc rotation mode which would then result in a significant drop of discharge voltage (around 120-200 V).For a given flow rate,the reduction of current resulted in a nearly linear increase of voltage.
文摘Charge is a fundamental physical property of matter that is responsible for its interactions with electromagnetic fields. The real nature and the essence of charge are unknown. In this paper, a new theory is presented to describe the nature and the essence of electric charge is formulated based on the vortex model of the electron which has a finite size and has an irrotational vortex structure. This theory and the vortex model of the electron enables us, for the first time, to describe the origin of bivalency, stability, quantization, equality of the absolute values of the bivalent charges, to derive a simple formulation to calculate the electric charge based on hydrodynamics without the use any constant. The difference between negative and positive charge, is revealed and the charged particles interactions are described. The electric charge is an expression of accelerated spherical mass per area reduced by the stiffness of the vacuum which has the units <i>ε</i><sub>0</sub> ML<sup>3</sup>/T<sup>2</sup>. The calculated results based on these equations comply accurately with the experimental results.
文摘In this work, a numerical study for designing a new kind of MHD (Magneto-Hydrn-Dynamic) pumps is presented. This technique makes a compromise between electrolysis prevention and high flow rate performance. This technique should eliminate electrolytic bubble generation, electrodes wear and fluid propriety modification. All these side phenomena are prevented by considering isolated electrodes. The numerical presented results in this paper demonstrate that continuous MHD pumping is possible with isolated electrodes. The MHD excitation combines a high frequency altering current with a low frequency altering magnetic field. In order to validate our results, two independent theoretical methods for computing flow rate are followed. The two presented independent approaches show that high flow rate is possible even with isolated electrodes. To overcome the problem of dimensioning this kind of pumps, a generic numerical analysis is proposed. Hence, the pump performances as functions of the external parameter are studied and tools to calculate for a given fluid and the optimal high frequency regime are provided.
文摘The aim of this work is to investigate the dependence of Zn S thin films structural and optical properties with the solution flow rate during the deposition using an ultrasonic spray method. The solution flow rate ranged from 10 to 50 m L/h and the substrate temperature was maintained at 450 °C. The effect of the solution flow rate on the properties of Zn S thin films was investigated by X-ray diffraction(XRD), scanning electron microscopy(SEM), optical transmittance spectroscopy(UV–V) and the four-point method. The X-ray diffraction analysis showed that the deposited material was pure zinc sulphide, it has a cubic sphalerite structure with preferential orientation along the(111) direction. The grain size values were calculated and found to be between 38 to 82 nm.SEM analysis revealed that the deposited thin films have good adherence to the substrate surfaces, are homogeneous and have high density. The average transmission of all films is up more than 65% in the range wavelength from 200 to 1100 nm and their band gap energy values were found between 3.5–3.92 e V. The obtained film thickness varies from 390 to 1040 nm. Moreover, the electric resistivity of the deposited films increases with the increasing of the solution flow rate between 3.51 × 10^5 and 11 × 10^5 Ω·cm.