期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
The Control System Simulation of Variable-Speed Constant-Frequency Wind Turbine
1
作者 窦金延 曹娜 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期202-206,共5页
In general,Variable-Speed Constant Frequency (VSCF)Wind generation system is controlled by stator voltage orientation method which based on the mathematic model of VSCF Wind generation system and discussed the control... In general,Variable-Speed Constant Frequency (VSCF)Wind generation system is controlled by stator voltage orientation method which based on the mathematic model of VSCF Wind generation system and discussed the control strategy.Present the whole dynamic control model of variable-speed wind generator system in MATLAB/ Simulink,and the simulation results confirm the validity and effectiveness of the proposed control strategy. 展开更多
关键词 Variable-Speed constant-frequency MODEL wind turbines control system vector control
下载PDF
Dynamic modelling and robust current control of wind-turbine driven DFIG during external AC voltage dip 被引量:10
2
作者 HU Jia-bing HE Yi-kang 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第10期1757-1764,共8页
Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy captu... Doubly-Fed Induction Generator (DFIG), with vector control applied, is widely used in Variable-Speed Constant- Frequency (VSCF) wind energy generation system and shows good performance in maximum wind energy capture. But in two traditional vector control schemes, the equivalent stator magnetizing current is considered invariant in order to simplify the rotor current inner-loop controller. The two schemes can perform very well when the grid is in normal condition. However, when grid disturbance such as grid voltage dip or swell fault occurs, the control performance worsens, the rotor over current occurs and the Fault Ride-Through (FRT) capability of the DFIG wind energy generation system gets seriously deteriorated. An accurate DFIG model was used to deeply investigate the deficiency of the traditional vector control. The improved control schemes of two typical traditional vector control schemes used in DFIG were proposed, and simulation study of the proposed and traditional control schemes, with robust rotor current control using Internal Model Control (IMC) method, was carded out. The validity of the proposed modified schemes to control the rotor current and to improve the FRT capability of the DFIG wind energy generation system was proved by the comparison study. 展开更多
关键词 Wind energy generation Variable-Speed constant-frequency (VSCF) Doubly-Fed Induction Generator (DFIG) Fault Ride-Through (FRT) Internal Model Control (IMC)
下载PDF