A test pattern generator (TPG) which can highly reduce the peak power consumption during built-in self-test (BIST) application is proposed. The proposed TPG, called LPpe-TPG, consists of a linear feedback shift re...A test pattern generator (TPG) which can highly reduce the peak power consumption during built-in self-test (BIST) application is proposed. The proposed TPG, called LPpe-TPG, consists of a linear feedback shift register (LFSR) and some control circuits. A procedure is presented firstly to make compare vectors between pseudorandom test patterns by adding some circuits to the original LFSR and secondly to insert some vectors between two successive pseudorandom test patterns according to the ordinal selection of every two bits of the compare vector. Then the changes between any successive test patterns of the test set generated by the LPpe-TPG are not more than twice. This leads to a decrease of the weighted switching activity (WSA) of the circuit under test (CUT) and therefore a reduction of the power consumption. Experimental results based on some ISCAS' 85 benchmark circuits show that the peak power consumption has been reduced by 25.25% to 64.46%. Also, the effectiveness of our approach to reduce the total and average power consumption is kept, without losing stuck-at fault coverage.展开更多
Background:The purpose of this study was to investigate whether patients with adult congenital heart disease(ACHD)benefit from exercise-based cardiac rehabilitation(CR)short-and long-term with regard to improvement of...Background:The purpose of this study was to investigate whether patients with adult congenital heart disease(ACHD)benefit from exercise-based cardiac rehabilitation(CR)short-and long-term with regard to improvement of cardiorespiratory fitness.Methods:Cardiopulmonary exercise tests(CPET)completed by ACHD patients between January 2000 and October 2019 were analysed retrospectively.Linear mixed models were performed for peak oxygen consumption(VO_(2))with patients as random effect and age,sex,disease classification,preceding surgery(≤3 months)and preceding CR(≤4 weeks for short term and>4 weeks for long term)as fixed effects.Results:1056 CPETs of 311 ACHD patients with simple(7),moderate(188)or great(116)complexity heart defects were analysed.The 59 patients who completed a CR(median age 27 yrs,38%females)increased peak VO_(2)from before to after CR by a median of 2.7(IQR–0.6 to 5.5)ml/kg/min.However,in the multivariate mixed model,peak VO_(2)was non-significantly increased short-term after CR(β0.8,95%CI–0.7 to 2.4),not maintained long-term after CR(β0.0,95%CI–1.7 to 1.6)but significantly reduced after surgery(β–5.1,95%CI–7.1 to–3.1).The 20 CR patients after surgery increased their peak VO_(2)by 6.2(IQR 3.6–9.5)ml/kg/min,while the 39 CR patients without preceding surgery increased it by 0.9(IQR–1.5 to 3.1)ml/kg/min.Conclusions:The increase in peak VO_(2)with CR was mainly due to recovery from surgical intervention.The small independent benefit from CR was not maintained long-term,highlighting the potential to improve current CR concepts in ACHD populations.展开更多
文摘A test pattern generator (TPG) which can highly reduce the peak power consumption during built-in self-test (BIST) application is proposed. The proposed TPG, called LPpe-TPG, consists of a linear feedback shift register (LFSR) and some control circuits. A procedure is presented firstly to make compare vectors between pseudorandom test patterns by adding some circuits to the original LFSR and secondly to insert some vectors between two successive pseudorandom test patterns according to the ordinal selection of every two bits of the compare vector. Then the changes between any successive test patterns of the test set generated by the LPpe-TPG are not more than twice. This leads to a decrease of the weighted switching activity (WSA) of the circuit under test (CUT) and therefore a reduction of the power consumption. Experimental results based on some ISCAS' 85 benchmark circuits show that the peak power consumption has been reduced by 25.25% to 64.46%. Also, the effectiveness of our approach to reduce the total and average power consumption is kept, without losing stuck-at fault coverage.
基金This project was awarded a contribution from the Swiss Heart Foundation.
文摘Background:The purpose of this study was to investigate whether patients with adult congenital heart disease(ACHD)benefit from exercise-based cardiac rehabilitation(CR)short-and long-term with regard to improvement of cardiorespiratory fitness.Methods:Cardiopulmonary exercise tests(CPET)completed by ACHD patients between January 2000 and October 2019 were analysed retrospectively.Linear mixed models were performed for peak oxygen consumption(VO_(2))with patients as random effect and age,sex,disease classification,preceding surgery(≤3 months)and preceding CR(≤4 weeks for short term and>4 weeks for long term)as fixed effects.Results:1056 CPETs of 311 ACHD patients with simple(7),moderate(188)or great(116)complexity heart defects were analysed.The 59 patients who completed a CR(median age 27 yrs,38%females)increased peak VO_(2)from before to after CR by a median of 2.7(IQR–0.6 to 5.5)ml/kg/min.However,in the multivariate mixed model,peak VO_(2)was non-significantly increased short-term after CR(β0.8,95%CI–0.7 to 2.4),not maintained long-term after CR(β0.0,95%CI–1.7 to 1.6)but significantly reduced after surgery(β–5.1,95%CI–7.1 to–3.1).The 20 CR patients after surgery increased their peak VO_(2)by 6.2(IQR 3.6–9.5)ml/kg/min,while the 39 CR patients without preceding surgery increased it by 0.9(IQR–1.5 to 3.1)ml/kg/min.Conclusions:The increase in peak VO_(2)with CR was mainly due to recovery from surgical intervention.The small independent benefit from CR was not maintained long-term,highlighting the potential to improve current CR concepts in ACHD populations.