期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Analysis of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection 被引量:2
1
作者 Zi-You Cai Yong-Chong Li +1 位作者 Li-Hua Li Zuan-Guang Chen 《Journal of Pharmaceutical Analysis》 CAS 2012年第5期356-360,共5页
A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrop... A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrophoretic operating parameters on the analysis of arecoline were studied. Under the optimal conditions, arecoline was rapidly separated and detected in 1 rain with good linearity over the concentration range of 20 1500 uM (r2=0.9991) and the detection limit of 5 uM (S/N=3). The method was used for the analysis of arecoline satisfactorily with a recovery of 96.8 -104%. 展开更多
关键词 Microchip capillary electrophoresis contactless conductivity detection ARECOLINE Semen Arecae
下载PDF
Sensitive Determination of Metal Ions in Drinking Water by Capillary Electrophoresis Coupled with Contactless Conductivity Detection Using 18-Crown-6 Ether and Hexadecyltrimethylammonium Bromide as Complexing Reagents 被引量:1
2
作者 Wujuan Chen Fan Gao +5 位作者 Yi Zhang Yan Zhang Yi Li Yating Zhang Qingjiang Wang Pingang He 《American Journal of Analytical Chemistry》 2016年第11期737-747,共12页
A simple, economical, and sensitive capillary electrophoresis (CE) method integrated with capacitively coupled contactless conductivity detection was developed for the determination of metal ions such as K<sup>+... A simple, economical, and sensitive capillary electrophoresis (CE) method integrated with capacitively coupled contactless conductivity detection was developed for the determination of metal ions such as K<sup>+</sup>, Na<sup>+</sup>, Mg<sup>2+</sup>, Sr<sup>2+</sup>, Ca<sup>2+</sup> in drinking water. 18-Crown-6 ether and Hexadecyltrimethylammonium Bromide (CTAB) were employed as complexing reagents. The effects of electrolyte additives, citric acid buffer solution, and other separation conditions of CE were comprehensively investigated and carefully optimized. The best results were obtained in a running buffer solution composed of citric acid (12 mM), 18-crown-6 ether (0.2 mM), and CTAB (0.015 mM) at pH 3.5. Under these conditions, a complete separation of five metal ions was successfully achieved in less than 12 min. The limits of detection for the optimal procedure were determined to be in the range of 0.02 - 0.2 mg·L<sup>-1</sup>. The repeatability with respect to migration times and peak areas, expressed as relative standard deviations, was better than 2.3% and 5.1%, respectively. Evaluation of the efficiency of the methodology indicated that it was reliable for the determination of metal ions in six different brands of drinking water samples. 展开更多
关键词 Capillary Electrophoresis contactless Conductivity detection Metal Ions FOOD Drinking Water
下载PDF
Analysis of Glutamic Acid in Cerebrospinal Fluid by Capillary Electrophoresis with High Frequency Conductivity Detection 被引量:1
3
作者 HalYunZHAI JunMeiWANG +3 位作者 XiaoLiYAO XueCaiTAN PeiXiangCAI ZuanGuangCHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第2期225-228,共4页
A rapid method to determine glutamic acid (Glu) in cerebrospinal fluid (CSF) by capillaryelectrophoresis with high frequency conductivity detection (contactless conductivity detection) wasdescribed. The CSF sample was... A rapid method to determine glutamic acid (Glu) in cerebrospinal fluid (CSF) by capillaryelectrophoresis with high frequency conductivity detection (contactless conductivity detection) wasdescribed. The CSF sample was pretreated with silver cation resin to remove high concentration ofCl- ions in CSF. The separation was achieved in the buffer solution of 10 mmol/L Tris and 8mmol/L boric acid at the separation voltage of 20.0 kV. Glu showed linear response in the range of5.0×10-6 to 6.0×10-3 mol/L, the limit of detection was 1.0×10-6 mol/L. The method was used foranalysis Glu in CSF satisfactorily with a recovery of 97.8-98.8%. 展开更多
关键词 Capillary electrophoresis high frequency conductivity detection contactless conducti-vity detection glutamic acid cerebrospinal fluid.
下载PDF
Highly sensitive humidity sensors based on hexagonal boron nitride nanosheets for contactless sensing 被引量:1
4
作者 Hang Liu Jinxu Qin +7 位作者 Xigui Yang Chaofan Lv Wentao Huang Fukui Li Chuang Zhang Yanran Wu Lin Dong Chongxin Shan 《Nano Research》 SCIE EI CSCD 2023年第7期10279-10286,共8页
Humidity sensors with high sensitivity,rapid response,and facile fabrication process for contactless sensing applications have received considerable attention in recent years.Herein,humidity sensors based on hexagonal... Humidity sensors with high sensitivity,rapid response,and facile fabrication process for contactless sensing applications have received considerable attention in recent years.Herein,humidity sensors based on hexagonal boron nitride(h-BN)nanosheets that are synthesized by a facile ultrasonic process have been fabricated,which display an ultrahigh sensitivity of 28,384%at 85%relative humidity(RH),rapid response/recovery time(3.0/5.5 s),and long-term stability in a wide humidity detection range(11%-85%RH),superior to most of the reported humidity sensors.The high sensitivity can be ascribed to the massive hydrophilic functional groups absorbed on the h-BN nanosheet surface.Benefiting from the high humidity sensing performances,contactless Morse code messaging and human writing and speech recognition have been demonstrated.This work demonstrates the great potential of the high-performance h-BN nanosheet-based humidity sensors for future contactless sensing devices. 展开更多
关键词 boron nitride humidity sensors contactless detection speech recognition
原文传递
Sensitive Determination of Five Priority Haloacetic Acids by Electromembrane Extraction with Capillary Electrophoresis
5
作者 Xiaoli Zhang Haitao Zhang +3 位作者 Yan Liu Lin Guo Jiannong Ye Qingcui Chu 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2015年第2期235-240,共6页
A method for sensitive determination of five priority haloacetic acids in drinking water has been developed for the first time based on electromembrane extraction(EME)prior to CZE with capacitively coupled contactless... A method for sensitive determination of five priority haloacetic acids in drinking water has been developed for the first time based on electromembrane extraction(EME)prior to CZE with capacitively coupled contactless conductivity detection(CZE-C^(4)D).The target analytes were extracted from 10 mL of the sample solution(donor phase),through the supported liquid membrane(using a polypropylene membrane supporting 1-octanol),and into 10μL of 50 mmol/L NaAc solution(acceptor phase).The extracted solution was directly analyzed by CZE-C^(4)D without de-rivatization.Several factors that affect separation,detection and extraction efficiency were investigated.Under the optimum conditions,five haloacetic acids(monochloroacetic acid,dichloroacetic acid,trichloroacetic acid,mono-bromoacetic acid,and dibromoacetic acid)could be well separated from other components coexisting in water samples within 23 min,exhibiting a linear calibration over two orders of magnitude(r≥0.9943);the enrichment factors at 430-671 were obtained in a 30 min of extraction,and the limits of detection were in the range of 0.17-0.61 ng/mL.The intraday relative standard deviations for peak areas investigated at 10 ng/mL were between 1.2%and 9.7%for the combined EME-CZE-C^(4)D procedure.This approach offers an attractive alternative to the officially proposed method for purified drinking water analysis,which requires derivatization procedure prior to gas chromatography analysis. 展开更多
关键词 disinfection byproducts haloacetic acids electromembrane extraction capillary electrophoresis ca-pacitively coupled contactless conductivity detection purified drinking water
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部