Recent ionospheric observations report anomalous total electron content (TEC) deviations prior strong earthquakes. We discuss common fetures of the pre-earthquake TEC disturbances on the basis of statistics covering 5...Recent ionospheric observations report anomalous total electron content (TEC) deviations prior strong earthquakes. We discuss common fetures of the pre-earthquake TEC disturbances on the basis of statistics covering 50 strong seismic events during 2005-2006. The F2-layer ionospheric plasma drift under action of the electric fields of seismic origin is proposed as the main reason of producing TEC anomalies. The origin of such electric fields is discussed in terms of the lithosphere-atmosphere-ionosphere coupling system. This theory is supported by numerical simulations using global Upper Atmosphere Model (UAM). UAM calculations show that the vertical electric current with the density of about 20 - 40 nA/m2 flowing between the Earth and ionosphere over an area of about 200 by 2000 km is required to produce the TEC disturbances with the amplitude of about 30% - 50% relatively to the non-disturbed conditions. Ionosphere responses on the variations of the latitudinal position, direction and configuration of the vertical electric currents have been investigated. We show that not only the vertical component of the ionospheric plasma drift but also horizontal components play an important role in producing pre-earthquake TEC disturbances.展开更多
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t...Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.展开更多
This paper is concerned with the problem of network power quality when grid connected systems are used to feed the grid. These systems use power electronic components such as inverters that produce harmonics which adv...This paper is concerned with the problem of network power quality when grid connected systems are used to feed the grid. These systems use power electronic components such as inverters that produce harmonics which adversely affect the power quality of the distribution network. Instead of using a conventional PI current controller with a fixed proportional and integral gain, development of new control method is considered to overcome the total harmonic emissions in PV inverters. It considers a modification to the controller where a random integral gain is used in the system. Experimental hardware is developed and result shows a reduced total harmonic distortion (THD) of the output current when tested with a resistive load.展开更多
In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and v...In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and voltage total harmonic distortion (THD), when it is assumed that the harmonic voltages or the harmonic currents in a distribution network increases by connection of many DGs through the inverters. The analysis on the influence of DGs is carried out by using a standard analytical model of distribution network with DGs based on the practical data. The authors evaluate quantitatively the influence which harmonics generated from DGs has on the harmonics of the distribution network, and analyze visually about propagation of harmonics within the distribution network. In addition, the authors also verify about the restraint effect of the harmonics in the network scale by the active filters installation.展开更多
The paper proposes a Current Source Multilevel Inverter (CSMLI) with single rating inductor topology. Multilevel inverters are most familiar with power converter’s applications due to reduced dv/dt, di/dt stress, and...The paper proposes a Current Source Multilevel Inverter (CSMLI) with single rating inductor topology. Multilevel inverters are most familiar with power converter’s applications due to reduced dv/dt, di/dt stress, and very efficient for reducing harmonic distortion in the output voltage and output current. The proposed nine-level current source inverter has been tested under symmetrical and asymmetrical modes of operation, and their activities are compared using PI and Fuzzy PI (Proportional Integral) controllers with multicarrier PWM (Pulse Width Modulation) strategy. MATLAB/Simulink simulation has been made for the proposed converter to obtain its performance measures. Some experimental results are given to verify the presented Current Source Multilevel Inverter.展开更多
This paper presents the comparison of various current control strategies employed for an interleaved power factor correction (PFC) boost converter for improving the power quality. The major control strategies discusse...This paper presents the comparison of various current control strategies employed for an interleaved power factor correction (PFC) boost converter for improving the power quality. The major control strategies discussed in this paper are: peak current control, average current control, hysteresis control, borderline current control and non-linear control. These strategies are implemented in MATLAB/SIMULINK and the performance of the proposed converter is compared under open loop and closed loop operation. From the results, the input current waveform was close to input voltage waveform implying improved power factor and reduced total harmonic distortion for nonlinear current control technique. Experimental results validate the proposed method.展开更多
The current global or regional ionospheric models have been established for monitoring the ionospheric variations. However, the spatial and temporal resolutions are not enough to describe total electron content(TEC)...The current global or regional ionospheric models have been established for monitoring the ionospheric variations. However, the spatial and temporal resolutions are not enough to describe total electron content(TEC) variations in small scales for China. In this paper, a regional ionospheric grid model(RIGM) with high spatial-temporal resolution(0.5 0.5 and 10-min interval) in China and surrounding areas is established based on spherical harmonics expansion from dense GPS measurements provided by Crustal Movement Observation Network of China(CMONOC) and the International GNSS Service(IGS). The correlation coefficient between the estimated TEC from GPS and the ionosonde measurements is 0.97, and the root mean square(RMS) with respect to Center for Orbit Determination in Europe(CODE) Global Ionosphere Maps(GIMs) is 4.87 TECU. In addition, the impact of different spherical harmonics orders and degrees on TEC estimations are evaluated and the degree/order 6 is better. Moreover, effective ionospheric shell heights from300 km to 700 km are further assessed and the result indicates that 550 km is the most suitable for regional ionospheric modeling in China at solar maximum.展开更多
Objective For the inverters used in UPS, it is important to maintain the pure sinusoidal AC output voltage waveform over all loading conditions and transients. Methods A novel sinusoidal output voltage control strat...Objective For the inverters used in UPS, it is important to maintain the pure sinusoidal AC output voltage waveform over all loading conditions and transients. Methods A novel sinusoidal output voltage control strategy is pregented in this paper. The output voltage is controlled by introducing filtering eapacitor current feedback. Two simple PI regulators are used for the current and voltage control loops. Results With the new control strategy, the inverter achieves very low output voltage distortion, good output voltage regulation and strong perturbation rejection, fast dynamic response, and good performance under nonlinear loads. The THD under capacitance rectifying load is better than 0.2%, the output voltage regulation within 0 to full load is less than 0.1%. The resting time under load transient is within 200?μ s . Conclusion The merits of the new control strategy include rapid response and good steady state stiffness.展开更多
为了提高中国区域电离层垂直总电子含量(vertical total electron content,VTEC)建模的精度,减少区域建模边缘误差,利用中国地壳运动观测网络(Crustal Movement Observation Network of China,CMONOC)和国际GNSS服务组织(International ...为了提高中国区域电离层垂直总电子含量(vertical total electron content,VTEC)建模的精度,减少区域建模边缘误差,利用中国地壳运动观测网络(Crustal Movement Observation Network of China,CMONOC)和国际GNSS服务组织(International GNSS Service,IGS)GPS数据联合进行电离层建模,并对中国区域电离层建模策略进行定量考察,对比给出各类建模策略对中国区域电离层建模精度的影响,从而给出更符合中国区域的电离层建模方式。将建模后的结果同IGS中心的全球电离层格网产品进行比对,结果显示:基于本文方法对中国区域电离层建模的结果精度更高,与IGS数据中心发布的电离层格网产品相比误差平均值为1.2109 TECU,与卫星实测电离层TEC的内符合精度误差为1.050 TECU。说明利用联合数据建模能一定程度上提高中国区域建模的精度,同时减少区域建模边缘的误差。展开更多
利用球谐模型和中国地壳运动观测网络及IGS(International GNSS Service)基准站的GPS观测数据,分别计算了中国区域及全球电离层电子总含量(Total Electron Content,TEC),采用了不同的统计分析方法,对汶川震中上空及邻近区域的TEC进...利用球谐模型和中国地壳运动观测网络及IGS(International GNSS Service)基准站的GPS观测数据,分别计算了中国区域及全球电离层电子总含量(Total Electron Content,TEC),采用了不同的统计分析方法,对汶川震中上空及邻近区域的TEC进行检查.结果发现:震前后一个星期,孕震区上空连续出现电离层异常扰动,其异常形态具有共轭结构,且呈现向磁赤道漂移趋势.展开更多
文摘Recent ionospheric observations report anomalous total electron content (TEC) deviations prior strong earthquakes. We discuss common fetures of the pre-earthquake TEC disturbances on the basis of statistics covering 50 strong seismic events during 2005-2006. The F2-layer ionospheric plasma drift under action of the electric fields of seismic origin is proposed as the main reason of producing TEC anomalies. The origin of such electric fields is discussed in terms of the lithosphere-atmosphere-ionosphere coupling system. This theory is supported by numerical simulations using global Upper Atmosphere Model (UAM). UAM calculations show that the vertical electric current with the density of about 20 - 40 nA/m2 flowing between the Earth and ionosphere over an area of about 200 by 2000 km is required to produce the TEC disturbances with the amplitude of about 30% - 50% relatively to the non-disturbed conditions. Ionosphere responses on the variations of the latitudinal position, direction and configuration of the vertical electric currents have been investigated. We show that not only the vertical component of the ionospheric plasma drift but also horizontal components play an important role in producing pre-earthquake TEC disturbances.
文摘Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.
文摘This paper is concerned with the problem of network power quality when grid connected systems are used to feed the grid. These systems use power electronic components such as inverters that produce harmonics which adversely affect the power quality of the distribution network. Instead of using a conventional PI current controller with a fixed proportional and integral gain, development of new control method is considered to overcome the total harmonic emissions in PV inverters. It considers a modification to the controller where a random integral gain is used in the system. Experimental hardware is developed and result shows a reduced total harmonic distortion (THD) of the output current when tested with a resistive load.
文摘In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and voltage total harmonic distortion (THD), when it is assumed that the harmonic voltages or the harmonic currents in a distribution network increases by connection of many DGs through the inverters. The analysis on the influence of DGs is carried out by using a standard analytical model of distribution network with DGs based on the practical data. The authors evaluate quantitatively the influence which harmonics generated from DGs has on the harmonics of the distribution network, and analyze visually about propagation of harmonics within the distribution network. In addition, the authors also verify about the restraint effect of the harmonics in the network scale by the active filters installation.
文摘The paper proposes a Current Source Multilevel Inverter (CSMLI) with single rating inductor topology. Multilevel inverters are most familiar with power converter’s applications due to reduced dv/dt, di/dt stress, and very efficient for reducing harmonic distortion in the output voltage and output current. The proposed nine-level current source inverter has been tested under symmetrical and asymmetrical modes of operation, and their activities are compared using PI and Fuzzy PI (Proportional Integral) controllers with multicarrier PWM (Pulse Width Modulation) strategy. MATLAB/Simulink simulation has been made for the proposed converter to obtain its performance measures. Some experimental results are given to verify the presented Current Source Multilevel Inverter.
文摘This paper presents the comparison of various current control strategies employed for an interleaved power factor correction (PFC) boost converter for improving the power quality. The major control strategies discussed in this paper are: peak current control, average current control, hysteresis control, borderline current control and non-linear control. These strategies are implemented in MATLAB/SIMULINK and the performance of the proposed converter is compared under open loop and closed loop operation. From the results, the input current waveform was close to input voltage waveform implying improved power factor and reduced total harmonic distortion for nonlinear current control technique. Experimental results validate the proposed method.
基金supported by the National Natural Science Foundation of China (NSFC) Project (11573052)Shanghai Science and Technology Commission Project (12DZ2273300)Key Laboratory of Planetary Sciences, Chinese Academy of Sciences
文摘The current global or regional ionospheric models have been established for monitoring the ionospheric variations. However, the spatial and temporal resolutions are not enough to describe total electron content(TEC) variations in small scales for China. In this paper, a regional ionospheric grid model(RIGM) with high spatial-temporal resolution(0.5 0.5 and 10-min interval) in China and surrounding areas is established based on spherical harmonics expansion from dense GPS measurements provided by Crustal Movement Observation Network of China(CMONOC) and the International GNSS Service(IGS). The correlation coefficient between the estimated TEC from GPS and the ionosonde measurements is 0.97, and the root mean square(RMS) with respect to Center for Orbit Determination in Europe(CODE) Global Ionosphere Maps(GIMs) is 4.87 TECU. In addition, the impact of different spherical harmonics orders and degrees on TEC estimations are evaluated and the degree/order 6 is better. Moreover, effective ionospheric shell heights from300 km to 700 km are further assessed and the result indicates that 550 km is the most suitable for regional ionospheric modeling in China at solar maximum.
文摘Objective For the inverters used in UPS, it is important to maintain the pure sinusoidal AC output voltage waveform over all loading conditions and transients. Methods A novel sinusoidal output voltage control strategy is pregented in this paper. The output voltage is controlled by introducing filtering eapacitor current feedback. Two simple PI regulators are used for the current and voltage control loops. Results With the new control strategy, the inverter achieves very low output voltage distortion, good output voltage regulation and strong perturbation rejection, fast dynamic response, and good performance under nonlinear loads. The THD under capacitance rectifying load is better than 0.2%, the output voltage regulation within 0 to full load is less than 0.1%. The resting time under load transient is within 200?μ s . Conclusion The merits of the new control strategy include rapid response and good steady state stiffness.
文摘为了提高中国区域电离层垂直总电子含量(vertical total electron content,VTEC)建模的精度,减少区域建模边缘误差,利用中国地壳运动观测网络(Crustal Movement Observation Network of China,CMONOC)和国际GNSS服务组织(International GNSS Service,IGS)GPS数据联合进行电离层建模,并对中国区域电离层建模策略进行定量考察,对比给出各类建模策略对中国区域电离层建模精度的影响,从而给出更符合中国区域的电离层建模方式。将建模后的结果同IGS中心的全球电离层格网产品进行比对,结果显示:基于本文方法对中国区域电离层建模的结果精度更高,与IGS数据中心发布的电离层格网产品相比误差平均值为1.2109 TECU,与卫星实测电离层TEC的内符合精度误差为1.050 TECU。说明利用联合数据建模能一定程度上提高中国区域建模的精度,同时减少区域建模边缘的误差。