Finding binary sequences with Large SHG ratios is very important in the field of ultrafast science, biomedical optics, high-resolution microscopy and label-free imaging. In this paper, we have demonstrated the relatio...Finding binary sequences with Large SHG ratios is very important in the field of ultrafast science, biomedical optics, high-resolution microscopy and label-free imaging. In this paper, we have demonstrated the relation between the SHG contrast ratio and the traditional Merit Factor values. And in the light from known results in Merit Factor Problems, we have shown that Legendre Sequences or Jacobi Sequences, are still the best candidates to obtain binary sequences with large SHG contrast ratios. The authors also discussed the SHG behaviors on some sequences obtained from cyclotomic classes over the finite field GF (2l) .展开更多
Colorless‐to‐black switching has attracted widespread attention for smart windows and multifunctional displays because they are more useful to control solar energy.However,it still remains a challenge owing to the t...Colorless‐to‐black switching has attracted widespread attention for smart windows and multifunctional displays because they are more useful to control solar energy.However,it still remains a challenge owing to the tremendous difficulties in the design of completely reverse absorptions in transmissive and colored states.Herein,we report on an electrochemical device that can switch between colorless and black by using the electrochemical process of hybrid organic–inorganic perovskite MAPbBr_(3),which shows a high integrated contrast ratio of up to 73%from 400 to 800 nm.The perovskite solution can be used as the active layer to assemble the device,showing superior transmittance over the entire visible region in neutral states.By applying an appropriate voltage,the device undergoes reversible switching between colorless and black,which is attributed to the formation of lead and Br_(2)in the redox reaction induced by the electron transfer process in MAPbBr_(3).In addition,the contrast ratio can be modulated over the entire visible region by changing the concentration and the applied voltage.These results contribute toward gaining an insightful understanding of the electrochemical process of perovskites and greatly promoting the development of switchable devices.展开更多
We demonstrate a high-quality cross-polarized-wave filter based on spectral phase modulation. Driven by Well- eompressed spectral-phase fully-compensated fundamental laser lmlses, the filter stretches the pulse bandwi...We demonstrate a high-quality cross-polarized-wave filter based on spectral phase modulation. Driven by Well- eompressed spectral-phase fully-compensated fundamental laser lmlses, the filter stretches the pulse bandwidth from 35 nm to 7Ohm with a conversion efficeiency of 20%.展开更多
Our latest research results on GaAs-A1GaAs multiple quantum well spatial light modulators are presented. The thickness uniformity of the epitaxial layers across the 3-inch wafer grown by our molecular beam epitaxy is ...Our latest research results on GaAs-A1GaAs multiple quantum well spatial light modulators are presented. The thickness uniformity of the epitaxial layers across the 3-inch wafer grown by our molecular beam epitaxy is better than 0.1% and the variation of cavity resonance wavelength within the wafer is only 0.9 nm. A contrast ratio (CR) of 102 by varying bias voltage from 0 to 6.7 V is achieved after fine tuning the cavity by etching an adjust layer. Both theoretical and experimental results demonstrate that incorporating an adjust layer is an effective tuning method for obtaining high CR.展开更多
Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 m...Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 male, 7 female, average age 59.4±13.2 years) with pathologically diagnosed pancreatic cancer were enrolled. All patients received an abdominal scan using a dual source CT scanner 7 to 31 days before biopsy or surgery. After injection of iodine contrast agent, arterial and pancreatic parenchyma phase were scanned consequently, using a dual-energy scan mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs) in the pancreatic parenchyma phase. A series of derived dual-energy datasets were evaluated including non-liner blending (non-linear blending width 0-500 HU; blending center -500 to 500 HU), mono-energetic (40-190 keV), 100 kVp and 140 kVp. On each datasets, mean CT values of the pancreatic parenchyma and tumor, as well as standard deviation CT values of subcutaneous fat and psoas muscle were measured. Regions of interest of cutaneous fat and major psoas muscle of 100 kVp and 140 kVp images were calculated. Best CNR of subcutaneous fat (CNR F ) and CNR of the major psoas muscle (CNR M ) of non-liner blending and mono-energetic datasets were calculated with the optimal mono-energetic keV setting and the optimal blending center/width setting for the best CNR. One Way ANOVA test was used for comparison of best CNR between different dual-energy derived datasets. Results The best CNR F (4.48±1.29) was obtained from the non-liner blending datasets at blending center -16.6±103.9 HU and blending width 12.3±10.6 HU. The best CNR F (3.28±0.97) was obtained from the mono-energetic datasets at 73.3±4.3 keV. CNR F in the 100 kVp and 140 kVp were 3.02±0.91 and 1.56±0.56 respectively. Using fat as the noise background, all of these images series showed significant differences (P<0.01) except best CNR F of mono-energetic image sets vs. CNR F of 100 kVp image (P=0.460). Similar results were found using muscle as the noise background (mono-energetic image vs. 100 kVp image: P=0.246; mono-energetic image vs. non-liner blending image: P=0.044; others: P<0.01). Conclusion Compared with mono-energetic datasets and low kVp datasets, non-linear blending image at automatically chosen blending width/window provides better tumor to the pancreas CNR, which might be beneficial for better detection of pancreatic tumors.展开更多
目的探讨自主研发的16通道高分辨盆腔专用线圈(16C)在3.0 T盆腔MRI中的应用价值。材料和方法前瞻性招募35例行盆腔MRI的患者,分别用16C线圈和32通道的体部线圈(32C)采集相同的轴位和矢状位T2WI序列。比较相同序列图像中第三骶椎、子宫...目的探讨自主研发的16通道高分辨盆腔专用线圈(16C)在3.0 T盆腔MRI中的应用价值。材料和方法前瞻性招募35例行盆腔MRI的患者,分别用16C线圈和32通道的体部线圈(32C)采集相同的轴位和矢状位T2WI序列。比较相同序列图像中第三骶椎、子宫肌层、前列腺外周带、直肠壁和闭孔内肌的信噪比(signal to noise ratio,SNR)及对比噪声比(contrast to noise ratio,CNR)。由两位诊断医师各自对两组图像质量和直肠轴位图像直肠壁分层结构的显示度进行主观评分。结果两组线圈相同序列的T2WI矢状位第三骶椎、子宫肌层、前列腺外周带和轴位闭孔内肌的SNR差异具有统计学意义(P<0.05),矢状位第三骶椎、子宫肌层和轴位直肠壁对肌肉的CNR差异具有统计学意义(P<0.05),16C组高于32C组。两组线圈相同序列的T2WI图像质量主观评价差异具有统计学意义(P<0.05),16C组图像质量更优。在轴位T2WI直肠壁分层结构的显示度评价方面两组图像差异具有统计学意义(P<0.05),16C组更优。结论16C线圈在3.0 T磁共振设备上成像质量更好,更有利于盆腔疾病的诊断。展开更多
目的探讨联合应用AIR-魔毯线圈磁共振成像(MRI)对胸椎结核扫描图像信噪比(signal to noise ratio,SNR)、对比噪声比(contrast to noise ratio,CNR)和脂肪抑制成像效果的价值。方法选取我院80例经手术病理证实为胸椎结核患者,按1:1随机...目的探讨联合应用AIR-魔毯线圈磁共振成像(MRI)对胸椎结核扫描图像信噪比(signal to noise ratio,SNR)、对比噪声比(contrast to noise ratio,CNR)和脂肪抑制成像效果的价值。方法选取我院80例经手术病理证实为胸椎结核患者,按1:1随机分为两组,应用常规线圈(脊柱相控阵线圈,头颈联合线圈)、常规线圈联合AIR魔毯线圈对两组患者分别进行扫描。扫描序列包括胸椎矢状位T_(2)WI,T_(1)WI,T_(2)FLEX,进一步测量、比较SNR,CNR及脂肪抑制效果,分析MRI多序列诊断胸腰椎结核的准确率、特异度和灵敏度。结果常规线圈联合AIR-魔毯线圈扫描组,胸椎矢状位图像的SNR、CNR及压脂效果优于常规线圈组。结论联合应用AIR-魔毯线圈的图像SNR、CNR得到提高,脂肪抑制效果稳定良好。展开更多
文摘Finding binary sequences with Large SHG ratios is very important in the field of ultrafast science, biomedical optics, high-resolution microscopy and label-free imaging. In this paper, we have demonstrated the relation between the SHG contrast ratio and the traditional Merit Factor values. And in the light from known results in Merit Factor Problems, we have shown that Legendre Sequences or Jacobi Sequences, are still the best candidates to obtain binary sequences with large SHG contrast ratios. The authors also discussed the SHG behaviors on some sequences obtained from cyclotomic classes over the finite field GF (2l) .
基金Natural Science Foundation of Hebei Province(China),Grant/Award Numbers:B2020203013,B2021203016Science and Technology Project of Hebei Education Department(China),Grant/Award Number:QN2020137+3 种基金Cultivation Project for Basic Research Innovation of Yanshan University(China),Grant/Award Number:2021LGZD015Subsidy for Hebei Key Laboratory of Applied Chemistry after Operation Performance(China),Grant/Award Number:22567616HNatural Science Foundation of Heilongjiang Province(China),Grant/Award Number:LH2022B025Fundamental Research Funds for the Provincial Universities of Heilongjiang Province(China),Grant/Award Number:KYYWF10236190104。
文摘Colorless‐to‐black switching has attracted widespread attention for smart windows and multifunctional displays because they are more useful to control solar energy.However,it still remains a challenge owing to the tremendous difficulties in the design of completely reverse absorptions in transmissive and colored states.Herein,we report on an electrochemical device that can switch between colorless and black by using the electrochemical process of hybrid organic–inorganic perovskite MAPbBr_(3),which shows a high integrated contrast ratio of up to 73%from 400 to 800 nm.The perovskite solution can be used as the active layer to assemble the device,showing superior transmittance over the entire visible region in neutral states.By applying an appropriate voltage,the device undergoes reversible switching between colorless and black,which is attributed to the formation of lead and Br_(2)in the redox reaction induced by the electron transfer process in MAPbBr_(3).In addition,the contrast ratio can be modulated over the entire visible region by changing the concentration and the applied voltage.These results contribute toward gaining an insightful understanding of the electrochemical process of perovskites and greatly promoting the development of switchable devices.
基金Supported by the National Key Basic Research Program of China under Grant No 2013CB922402the National Natural Science Foundation of China under Grant Nos 61575217 and 11434016+1 种基金the Key Research Program of Frontier Sciences of Chinese Academy of Sciences under Grant Nos KJZD-EW-L11-03 and QYZDJ-SSW-JSC006the Strategic Priority Research Program of Chinese Academy of Sciences under Grant No XDB16030200
文摘We demonstrate a high-quality cross-polarized-wave filter based on spectral phase modulation. Driven by Well- eompressed spectral-phase fully-compensated fundamental laser lmlses, the filter stretches the pulse bandwidth from 35 nm to 7Ohm with a conversion efficeiency of 20%.
基金supported by the President Fund of CAS,the International Collaboration Plan for Science and Technology of the Chinese Ministry of Science and Technology(No.2008KR0415)the Suzhou International Cooperation Fund,China(No.SWH0809).
文摘Our latest research results on GaAs-A1GaAs multiple quantum well spatial light modulators are presented. The thickness uniformity of the epitaxial layers across the 3-inch wafer grown by our molecular beam epitaxy is better than 0.1% and the variation of cavity resonance wavelength within the wafer is only 0.9 nm. A contrast ratio (CR) of 102 by varying bias voltage from 0 to 6.7 V is achieved after fine tuning the cavity by etching an adjust layer. Both theoretical and experimental results demonstrate that incorporating an adjust layer is an effective tuning method for obtaining high CR.
文摘Objective To quantitatively compare and determine the best pancreatic tumor contrast to noise ratio (CNR) in different dual-energy derived datasets. Methods In this retrospective, single center study, 16 patients (9 male, 7 female, average age 59.4±13.2 years) with pathologically diagnosed pancreatic cancer were enrolled. All patients received an abdominal scan using a dual source CT scanner 7 to 31 days before biopsy or surgery. After injection of iodine contrast agent, arterial and pancreatic parenchyma phase were scanned consequently, using a dual-energy scan mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs) in the pancreatic parenchyma phase. A series of derived dual-energy datasets were evaluated including non-liner blending (non-linear blending width 0-500 HU; blending center -500 to 500 HU), mono-energetic (40-190 keV), 100 kVp and 140 kVp. On each datasets, mean CT values of the pancreatic parenchyma and tumor, as well as standard deviation CT values of subcutaneous fat and psoas muscle were measured. Regions of interest of cutaneous fat and major psoas muscle of 100 kVp and 140 kVp images were calculated. Best CNR of subcutaneous fat (CNR F ) and CNR of the major psoas muscle (CNR M ) of non-liner blending and mono-energetic datasets were calculated with the optimal mono-energetic keV setting and the optimal blending center/width setting for the best CNR. One Way ANOVA test was used for comparison of best CNR between different dual-energy derived datasets. Results The best CNR F (4.48±1.29) was obtained from the non-liner blending datasets at blending center -16.6±103.9 HU and blending width 12.3±10.6 HU. The best CNR F (3.28±0.97) was obtained from the mono-energetic datasets at 73.3±4.3 keV. CNR F in the 100 kVp and 140 kVp were 3.02±0.91 and 1.56±0.56 respectively. Using fat as the noise background, all of these images series showed significant differences (P<0.01) except best CNR F of mono-energetic image sets vs. CNR F of 100 kVp image (P=0.460). Similar results were found using muscle as the noise background (mono-energetic image vs. 100 kVp image: P=0.246; mono-energetic image vs. non-liner blending image: P=0.044; others: P<0.01). Conclusion Compared with mono-energetic datasets and low kVp datasets, non-linear blending image at automatically chosen blending width/window provides better tumor to the pancreas CNR, which might be beneficial for better detection of pancreatic tumors.
文摘目的探讨自主研发的16通道高分辨盆腔专用线圈(16C)在3.0 T盆腔MRI中的应用价值。材料和方法前瞻性招募35例行盆腔MRI的患者,分别用16C线圈和32通道的体部线圈(32C)采集相同的轴位和矢状位T2WI序列。比较相同序列图像中第三骶椎、子宫肌层、前列腺外周带、直肠壁和闭孔内肌的信噪比(signal to noise ratio,SNR)及对比噪声比(contrast to noise ratio,CNR)。由两位诊断医师各自对两组图像质量和直肠轴位图像直肠壁分层结构的显示度进行主观评分。结果两组线圈相同序列的T2WI矢状位第三骶椎、子宫肌层、前列腺外周带和轴位闭孔内肌的SNR差异具有统计学意义(P<0.05),矢状位第三骶椎、子宫肌层和轴位直肠壁对肌肉的CNR差异具有统计学意义(P<0.05),16C组高于32C组。两组线圈相同序列的T2WI图像质量主观评价差异具有统计学意义(P<0.05),16C组图像质量更优。在轴位T2WI直肠壁分层结构的显示度评价方面两组图像差异具有统计学意义(P<0.05),16C组更优。结论16C线圈在3.0 T磁共振设备上成像质量更好,更有利于盆腔疾病的诊断。
文摘目的探讨联合应用AIR-魔毯线圈磁共振成像(MRI)对胸椎结核扫描图像信噪比(signal to noise ratio,SNR)、对比噪声比(contrast to noise ratio,CNR)和脂肪抑制成像效果的价值。方法选取我院80例经手术病理证实为胸椎结核患者,按1:1随机分为两组,应用常规线圈(脊柱相控阵线圈,头颈联合线圈)、常规线圈联合AIR魔毯线圈对两组患者分别进行扫描。扫描序列包括胸椎矢状位T_(2)WI,T_(1)WI,T_(2)FLEX,进一步测量、比较SNR,CNR及脂肪抑制效果,分析MRI多序列诊断胸腰椎结核的准确率、特异度和灵敏度。结果常规线圈联合AIR-魔毯线圈扫描组,胸椎矢状位图像的SNR、CNR及压脂效果优于常规线圈组。结论联合应用AIR-魔毯线圈的图像SNR、CNR得到提高,脂肪抑制效果稳定良好。