As competition intensifies, many companies are exploring new ways of performance appraisal. This paper analyzes the scientificity, rationality, and feasibility of the contribution method of the project as a unit, and ...As competition intensifies, many companies are exploring new ways of performance appraisal. This paper analyzes the scientificity, rationality, and feasibility of the contribution method of the project as a unit, and provides a reference for the reform of the performance appraisal method of the architectural design enterprise.展开更多
In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and ba...In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and balancing a large number of loads nearby.However,under the background of a large-scale DPV grid-connected to the county distribution network,an effective analysis method is needed to analyze its impact on the voltage of the distribution network in the early development stage of DPV.Therefore,a DPV orderly grid-connected method based on photovoltaics grid-connected order degree(PGOD)is proposed.This method aims to orderly analyze the change of voltage in the distribution network when large-scale DPV will be connected.Firstly,based on the voltagemagnitude sensitivity(VMS)index of the photovoltaics permitted grid-connected node and the acceptance of grid-connected node(AoGCN)index of other nodes in the network,thePGODindex is constructed to determine the photovoltaics permitted grid-connected node of the current photovoltaics grid-connected state network.Secondly,a photovoltaics orderly grid-connected model with a continuous updating state is constructed to obtain an orderly DPV grid-connected order.The simulation results illustrate that the photovoltaics grid-connected order determined by this method based on PGOD can effectively analyze the voltage impact of large-scale photovoltaics grid-connected,and explore the internal factors and characteristics of the impact.展开更多
A problem of the air pollution control in China is getting to know a regional contribution rate of internal and external source of PM2.5. In this paper,Set Pair Analysis( SPA) method is proposed to calculate the con...A problem of the air pollution control in China is getting to know a regional contribution rate of internal and external source of PM2.5. In this paper,Set Pair Analysis( SPA) method is proposed to calculate the contribution rate of PM2.5in Dongguan City. Due to geographic,meteorological factors and the low concentration of air pollutants in Qingxi area,the PM2.5in this place is mainly contributed by the regional transport of air pollutants from other inside areas of Dongguan,and less affected by the outside of Dongguan. So the concentration of PM2.5in Qingxi area can reflect the Dongguan's basic background concentration of PM2.5. On the basis of the basic background concentration,firstly the concentration of each pollutant components is divided into the internal part and the mixed part. Secondly using the source apportionment samples of five monitoring sites in Dongguan we can respectively construct a sample set A and an evaluation set B. Thirdly the SPA is operated onto the mixed part in terms of set B.At last the connection degree between the concentration of each pollutant components and external source and internal source will be calculated,that is the contribution rate. The research reveals that the contribution rate of internal source and external source of PM2.5in Dongguan City is 83%and 17% respectively,which roughly met expectations. This method is simple and effective and it can provide a reference for the government taking reduction measures to control PM2.5pollutants emission.展开更多
文摘As competition intensifies, many companies are exploring new ways of performance appraisal. This paper analyzes the scientificity, rationality, and feasibility of the contribution method of the project as a unit, and provides a reference for the reform of the performance appraisal method of the architectural design enterprise.
基金supported by North China Electric Power Research Institute’s Self-Funded Science and Technology Project“Research on Distributed Energy Storage Optimal Configuration and Operation Control Technology for Photovoltaic Promotion in the Entire County”(KJZ2022049).
文摘In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and balancing a large number of loads nearby.However,under the background of a large-scale DPV grid-connected to the county distribution network,an effective analysis method is needed to analyze its impact on the voltage of the distribution network in the early development stage of DPV.Therefore,a DPV orderly grid-connected method based on photovoltaics grid-connected order degree(PGOD)is proposed.This method aims to orderly analyze the change of voltage in the distribution network when large-scale DPV will be connected.Firstly,based on the voltagemagnitude sensitivity(VMS)index of the photovoltaics permitted grid-connected node and the acceptance of grid-connected node(AoGCN)index of other nodes in the network,thePGODindex is constructed to determine the photovoltaics permitted grid-connected node of the current photovoltaics grid-connected state network.Secondly,a photovoltaics orderly grid-connected model with a continuous updating state is constructed to obtain an orderly DPV grid-connected order.The simulation results illustrate that the photovoltaics grid-connected order determined by this method based on PGOD can effectively analyze the voltage impact of large-scale photovoltaics grid-connected,and explore the internal factors and characteristics of the impact.
基金Supported by National Natural Science Foundation of China(71171089)Research for PM_(2.5) Contamination Characteristics and Prevention and Control Countermeasures in Dongguan City(Dongcaidan[2013]222)
文摘A problem of the air pollution control in China is getting to know a regional contribution rate of internal and external source of PM2.5. In this paper,Set Pair Analysis( SPA) method is proposed to calculate the contribution rate of PM2.5in Dongguan City. Due to geographic,meteorological factors and the low concentration of air pollutants in Qingxi area,the PM2.5in this place is mainly contributed by the regional transport of air pollutants from other inside areas of Dongguan,and less affected by the outside of Dongguan. So the concentration of PM2.5in Qingxi area can reflect the Dongguan's basic background concentration of PM2.5. On the basis of the basic background concentration,firstly the concentration of each pollutant components is divided into the internal part and the mixed part. Secondly using the source apportionment samples of five monitoring sites in Dongguan we can respectively construct a sample set A and an evaluation set B. Thirdly the SPA is operated onto the mixed part in terms of set B.At last the connection degree between the concentration of each pollutant components and external source and internal source will be calculated,that is the contribution rate. The research reveals that the contribution rate of internal source and external source of PM2.5in Dongguan City is 83%and 17% respectively,which roughly met expectations. This method is simple and effective and it can provide a reference for the government taking reduction measures to control PM2.5pollutants emission.