期刊文献+
共找到20,542篇文章
< 1 2 250 >
每页显示 20 50 100
Effect and mechanism of on-chip electrostatic discharge protection circuit under fast rising time electromagnetic pulse
1
作者 Mao Xinyi Chai Changchun +3 位作者 Li Fuxing Lin Haodong Zhao Tianlong Yang Yintang 《强激光与粒子束》 CAS CSCD 北大核心 2024年第10期44-52,共9页
The electrostatic discharge(ESD)protection circuit widely exists in the input and output ports of CMOS digital circuits,and fast rising time electromagnetic pulse(FREMP)coupled into the device not only interacts with ... The electrostatic discharge(ESD)protection circuit widely exists in the input and output ports of CMOS digital circuits,and fast rising time electromagnetic pulse(FREMP)coupled into the device not only interacts with the CMOS circuit,but also acts on the protection circuit.This paper establishes a model of on-chip CMOS electrostatic discharge protection circuit and selects square pulse as the FREMP signals.Based on multiple physical parameter models,it depicts the distribution of the lattice temperature,current density,and electric field intensity inside the device.At the same time,this paper explores the changes of the internal devices in the circuit under the injection of fast rising time electromagnetic pulse and describes the relationship between the damage amplitude threshold and the pulse width.The results show that the ESD protection circuit has potential damage risk,and the injection of FREMP leads to irreversible heat loss inside the circuit.In addition,pulse signals with different attributes will change the damage threshold of the circuit.These results provide an important reference for further evaluation of the influence of electromagnetic environment on the chip,which is helpful to carry out the reliability enhancement research of ESD protection circuit. 展开更多
关键词 fast rising time electromagnetic pulse damage effect electrostatic discharge protection circuit damage location prediction
下载PDF
Fractional Gradient Descent RBFNN for Active Fault-Tolerant Control of Plant Protection UAVs
2
作者 Lianghao Hua Jianfeng Zhang +1 位作者 Dejie Li Xiaobo Xi 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2129-2157,共29页
With the increasing prevalence of high-order systems in engineering applications, these systems often exhibitsignificant disturbances and can be challenging to model accurately. As a result, the active disturbance rej... With the increasing prevalence of high-order systems in engineering applications, these systems often exhibitsignificant disturbances and can be challenging to model accurately. As a result, the active disturbance rejectioncontroller (ADRC) has been widely applied in various fields. However, in controlling plant protection unmannedaerial vehicles (UAVs), which are typically large and subject to significant disturbances, load disturbances andthe possibility of multiple actuator faults during pesticide spraying pose significant challenges. To address theseissues, this paper proposes a novel fault-tolerant control method that combines a radial basis function neuralnetwork (RBFNN) with a second-order ADRC and leverages a fractional gradient descent (FGD) algorithm.We integrate the plant protection UAV model’s uncertain parameters, load disturbance parameters, and actuatorfault parameters and utilize the RBFNN for system parameter identification. The resulting ADRC exhibits loaddisturbance suppression and fault tolerance capabilities, and our proposed active fault-tolerant control law hasLyapunov stability implications. Experimental results obtained using a multi-rotor fault-tolerant test platformdemonstrate that the proposed method outperforms other control strategies regarding load disturbance suppressionand fault-tolerant performance. 展开更多
关键词 Radial basis function neural network plant protection unmanned aerial vehicle active disturbance rejection controller fractional gradient descent algorithm
下载PDF
Influence of DFIG Wind Turbine Protection and Control during Voltage Dip on Circuit Breaker Operation
3
作者 Anssi Salomo Makinen Ontrei Raipala Sami Repo Heikki Tuusa 《Journal of Energy and Power Engineering》 2013年第1期126-138,共13页
This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossing... This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossings of the fault current occur. This is an important subject because the ftmdamental property of the CB (circuit breaker) is that it breaks the current when the current is very near zero. The study was conducted using a hardware-in-the-loop test environment constructed using two real time simulators (dSPACE and RTDS) and a commercial protection relay. It is found that the reactive current injection during a voltage dip demanded by the grid codes enhances the operation of the WT protection because the zero crossings of the currents through CB are attained earlier. In addition, the size of the crowbar resistance has a significant influence on the zero crossings. 展开更多
关键词 DFIG reactive current circuit breaker loss of mains relay protection.
下载PDF
Research on the overload protection reliability of moulded case circuit-breakers and its test device 被引量:14
4
作者 LI Kui LU Jian-guo +2 位作者 WU Yi QIN Zhi-jun YAO Dong-mei 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期453-458,共6页
This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on... This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly. 展开更多
关键词 Moulded case circuit breakers Overload protection RELIABILITY Test device
下载PDF
Study on the instantaneous protection reliability of low voltage circuit breakers 被引量:8
5
作者 LU Jian-guo DU Tai-hang LUO Yan-yan 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期370-377,共8页
This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage cir... This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage circuit breakers was analyzed so that measures to improve instantaneous protection reliability can be determined. Furthermore, the theory of the instantaneous characteristics calibration device for low voltage circuit breakers and the method of eliminating the non-periodic component of test current are given in detail. Finally, the test results are presented. 展开更多
关键词 Low voltage circuit breakers Instantaneous protection reliability Non-periodic component of current Phase selective closing
下载PDF
Privacy Protection Based Access Control Scheme in Cloud-Based Services 被引量:3
6
作者 Kai Fan Qiong Tian +2 位作者 Junxiong Wang Hui Li Yintang Yang 《China Communications》 SCIE CSCD 2017年第1期61-71,共11页
With the rapid development of computer technology, cloud-based services have become a hot topic. They not only provide users with convenience, but also bring many security issues, such as data sharing and privacy issu... With the rapid development of computer technology, cloud-based services have become a hot topic. They not only provide users with convenience, but also bring many security issues, such as data sharing and privacy issue. In this paper, we present an access control system with privilege separation based on privacy protection(PS-ACS). In the PS-ACS scheme, we divide users into private domain(PRD) and public domain(PUD) logically. In PRD, to achieve read access permission and write access permission, we adopt the Key-Aggregate Encryption(KAE) and the Improved Attribute-based Signature(IABS) respectively. In PUD, we construct a new multi-authority ciphertext policy attribute-based encryption(CP-ABE) scheme with efficient decryption to avoid the issues of single point of failure and complicated key distribution, and design an efficient attribute revocation method for it. The analysis and simulation result show that our scheme is feasible and superior to protect users' privacy in cloud-based services. 展开更多
关键词 access control data sharing privacy protection cloud-based services
下载PDF
High-Speed Trains Automatic Operation with Protection Constraints: A Resilient Nonlinear Gain-based Feedback Control Approach 被引量:2
7
作者 Shigen Gao Yuhan Hou +2 位作者 Hairong Dong Sebastian Stichel Bin Ning 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第4期992-999,共8页
This paper addresses the control design for automatic train operation of high-speed trains with protection constraints.A new resilient nonlinear gain-based feedback control approach is proposed,which is capable of gua... This paper addresses the control design for automatic train operation of high-speed trains with protection constraints.A new resilient nonlinear gain-based feedback control approach is proposed,which is capable of guaranteeing,under some proper non-restrictive initial conditions,the protection constraints control raised by the distance-to-go(moving authority)curve and automatic train protection in practice.A new hyperbolic tangent function-based model is presented to mimic the whole operation process of high-speed trains.The proposed feedback control methods are easily implementable and computationally inexpensive because the presence of only two feedback gains guarantee satisfactory tracking performance and closed-loop stability,no adaptations of unknown parameters,function approximation of unknown nonlinearities,and attenuation of external disturbances in the proposed control strategies.Finally,rigorous proofs and comparative simulation results are given to demonstrate the effectiveness of the proposed approaches. 展开更多
关键词 AUTOMATIC TRAIN operation high-speed TRAIN nonlinear GAIN feedback protection CONSTRAINT resilient control
下载PDF
Architecture Design for Integrated Wide Area Protection and Control Systems 被引量:2
8
作者 Z. Q. Bo Q. P. Wang +3 位作者 Lin Wang Fengqun Zhou Shengming Ge B. M. Zhang 《Journal of Power and Energy Engineering》 2015年第4期412-416,共5页
This paper firstly reviews the recent development in power system protection and control, with special attention paid to the wide-area and integrated protection, in order to look into future development of integration... This paper firstly reviews the recent development in power system protection and control, with special attention paid to the wide-area and integrated protection, in order to look into future development of integration of protection and control for smart grids. This paper mainly reports on the development of integrated wide area protection and control for power systems. The concept of integrated wide area protection and control is introduced, in which a hierarchical protection and control system provides the protection and control of wide area or regional power substations/ plants and their associated power network. The system is mainly divided into three levels, the local, the substation/plant and the wide area/regional protection and control. The integrated functions at each level are described in details with an aim to develop an optimal coordination mechanism between the levels. One of the core elements in the system is the synchronised wide area communication network between the substations and the protection and control system, in which latest communication technology is employed. Another important player in the system is the wide area synchronized protection and control information platform, which not only enables the fusion three line of defence for power system protection and control, but also provides a perfect tool for the application of cloud computing to substations and power networks. 展开更多
关键词 INTEGRATED protection WIDE Area protection protection and control CLOUD COMPUTING
下载PDF
Seismic protection of frame structures via semi-active control:modeling and implementation issues 被引量:1
9
作者 Vincenzo Gattulli Marco Lepidi Francesco Potenza 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2009年第4期627-645,共19页
Theoretical and practical issues concerning the multi-faceted task of mitigating the latero-torsional seismic response of a prototypal frame structure with asymmetric mass distribution are approached, Chevron braces w... Theoretical and practical issues concerning the multi-faceted task of mitigating the latero-torsional seismic response of a prototypal frame structure with asymmetric mass distribution are approached, Chevron braces with embedded magnetorheological dampers acting on the interstory drift are used to ensure additional energy dissipation. The semi-active control strategy employed to govern the modification of the damper characteristics via feedback is based on the selection of optimal forces according to a H2/LQG criterion, with respect to which the actual forces are regulated by a clipped-optimal logic. A dynamic observer is used to estimate the state through a non-collocated placement of the acceleration sensors. Several aspects to be addressed throughout the complex process including the design, modelization, and implementation phases of semi-active protection systems are discussed. Finally, experimental results obtained to mitigate the motion induced by ground excitation in a large-scale laboratory prototype, simulating the seismic response of a two-story building, are summarized. 展开更多
关键词 seismic protection flame structures semi-active control magnetorheological damper
下载PDF
Protection and Quality Control of Wild Chinese Herbal Medicine Resources in Nature Reserves by Taking Longyuwan Scenic Spot Within Funiu Mountain Nature Reserve as an Example 被引量:1
10
作者 Wang Shao-hui Liu Meng-na +4 位作者 Wang Xu Zhang Ya-chen Han Yi-wen Zhang Ce Liu Tong-xiang 《Journal of Northeast Agricultural University(English Edition)》 CAS 2016年第3期90-96,共7页
This paper discussed how to protect and control the quality of wild Chinese herbal medicine resources in nature reserves by taking Longyuwan National Forest Park within Funiu Mountain Nature Reserve as an example. Thr... This paper discussed how to protect and control the quality of wild Chinese herbal medicine resources in nature reserves by taking Longyuwan National Forest Park within Funiu Mountain Nature Reserve as an example. Through the combination of three methods including literature review, visiting and investigational studies, and field surveys, the data of investigation, collection and collation were analyzed. According to data of surveys, collection and collation, problems related to the protection of wild Chinese herbal medicine resources faced by Longyuwan Scenic Spot within Funiu Mountain Nature Reserve were also analyzed and protection strategies and quality control of wild Chinese herbal medicine resources in this nature reserve were discussed. It was expected that the results would provide important scientific references for the sustainable development, protection and quality control of wild Chinese herbal medicine resources within nature reserves. 展开更多
关键词 nature reserve wild Chinese herbal medicine resource protection quality control
下载PDF
Immobilization of antibodies on the self-assembled monolayer by antigen-binding site protection and immobilization kinetic control 被引量:1
11
作者 Myungok Yoon Hyun Jin Hwang Jeong Hee Kim 《Journal of Biomedical Science and Engineering》 2011年第4期242-247,共6页
The orientation of the biological molecule immobi-lized on a solid surface has been critical in devel-opment of various applications. In this study, ori-entation of antibody was retained by protecting the antigen-bind... The orientation of the biological molecule immobi-lized on a solid surface has been critical in devel-opment of various applications. In this study, ori-entation of antibody was retained by protecting the antigen-binding site of the antibody prior to immo-bilization to -functionalized mixed self-assembled monolayer (SAM) of 12-mercaptododecanoic acid and 1-heptanethiol. More importantly, the number of immobilization bonds formed between each an-tigen-binding site protected antibody molecule and the solid surface was controlled by optimizing the mole fraction of the activated carboxyl group of the linker molecules in the mixed SAM. The amount of antibody used in this study was approximately equivalent to the amount for one monolayer surface coverage. The resulting activity of protected immo-bilized antibody was about 10 fold higher than that of random immobilized 展开更多
关键词 Antibody Oriented IMMOBILIZATION Antigen-Binding Site protection SELF-ASSEMBLED MONOLAYER Kinetic control
下载PDF
Study on DeviceNet communication mechanism and its application in protection measurement and control system 被引量:1
12
作者 佟为明 Li Zhongwei +1 位作者 Sun Fanjin Cheng Shukang 《High Technology Letters》 EI CAS 2007年第1期1-5,共5页
To fit in with the developing requirement of int and communication of protective relays, a protection egrated functions of protection measurement, control measurement and control system based on DeviceNet fieldbus is ... To fit in with the developing requirement of int and communication of protective relays, a protection egrated functions of protection measurement, control measurement and control system based on DeviceNet fieldbus is designed. The communication mechanism of DeviceNet is studied and data trigger modes, communication connection, message types and other key technologies are analyzed. The object modeling and device description of the device are realized too. Results of network test, dynamic simulation and test in the field indicate that this system can accomplish all the communication tasks in real time and can make precise response to every kind of faults of the motor, transformer, line and capacitor. Moreover, this system has higher measurement precision and better control capability. 展开更多
关键词 communication mechanism protection measurement and control system FIELDBUS DEVICENET
下载PDF
A New Analyzing Method of Single Event Latch-Up Protection Circuit Based on Current Comparing and Its Performance Verification 被引量:1
13
作者 Pengwei Li Xiaoyun Fu +1 位作者 Lei Luo Qingkui Yu 《Journal of Modern Physics》 2014年第6期387-393,共7页
Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit ... Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit based on current-comparing method is designed to protect the electronics away from SEL’s damage in radiation environment. The response time of protection circuit has been analyzed. The signal simulation results indicated that the operating time of the SEL protection circuit is dependent on the action time of current comparator and system application recovery time. The function of the monitoring circuit protection device away from SEL’s damage has validated through experiment at last. 展开更多
关键词 SEL protection circuit Power-On TIME CUT-OFF TIME ADJUSTABLE Recovery TIME COTS
下载PDF
Operation Control Method of Relay Protection in Flexible DC Distribution Network Compatible with Distributed Power Supply 被引量:1
14
作者 Zihan Qi 《Energy Engineering》 EI 2023年第11期2547-2563,共17页
A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to... A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to poor performance.The method combines a fault-tolerant fault location method based on long-term and short-term memory networks to accurately locate the fault section.Then,an operation control method for relay protection based on adaptive weight and whale optimization algorithm(WOA)is used to construct an objective function considering the shortest relay protection action time and the smallest impulse current.The adaptive weight and WOA are employed to obtain the optimal strategy for relay protection operation control,reducing the action time and impulse current.Experimental results demonstrate the effectiveness of the proposed method in accurately locating faults and improving relay protection performance.The longest operation time is reduced by 4.7023 s,and the maximum impulse current is limited to 0.3 A,effectively controlling the impact of large impulse currents and enhancing control efficiency. 展开更多
关键词 Compatible distributed power supply FLEXIBILITY DC distribution network relay protection operation control
下载PDF
Passive activity enhances residual control ability in patients with complete spinal cord injury
15
作者 Yanqing Xiao Mingming Gao +6 位作者 Zejia He Jia Zheng Hongming Bai Jia-Sheng Rao Guiyun Song Wei Song Xiaoguang Li 《Neural Regeneration Research》 SCIE CAS 2025年第8期2337-2347,共11页
Patients with complete spinal cord injury retain the potential for volitional muscle activity in muscles located below the spinal injury level.However,because of prolonged inactivity,initial attempts to activate these... Patients with complete spinal cord injury retain the potential for volitional muscle activity in muscles located below the spinal injury level.However,because of prolonged inactivity,initial attempts to activate these muscles may not effectively engage any of the remaining neurons in the descending pathway.A previous study unexpectedly found that a brief clinical round of passive activity significantly increased volitional muscle activation,as measured by surface electromyography.In this study,we further explored the effect of passive activity on surface electromyographic signals during volitional control tasks among individuals with complete spinal cord injury.Eleven patients with chronic complete thoracic spinal cord injury were recruited.Surface electromyography data from eight major leg muscles were acquired and compared before and after the passive activity protocol.The results indicated that the passive activity led to an increased number of activated volitional muscles and an increased frequency of activation.Although the cumulative root mean square of surface electromyography amplitude for volitional control of movement showed a slight increase after passive activity,the difference was not statistically significant.These findings suggest that brief passive activity may enhance the ability to initiate volitional muscle activity during surface electromyography tasks and underscore the potential of passive activity for improving residual motor control among patients with motor complete spinal cord injury. 展开更多
关键词 complete spinal cord injury cycle training epidural electrical stimulation motor training passive activity physiological state spinal cord circuit surface electromyography volitional control task
下载PDF
Research on Technology of Electromagnetic Protection for the Generator Control System
16
作者 Baocheng Wang Guyong Han Lin Zhu 《Journal of Power and Energy Engineering》 2014年第4期7-12,共6页
Generator control system decides whether the generator can work as usual or not, as well as its stability of performance. Both types of generators control system composed of the transistor and DSP are sensitive to out... Generator control system decides whether the generator can work as usual or not, as well as its stability of performance. Both types of generators control system composed of the transistor and DSP are sensitive to outward electromagnetic interference, directly related to the generator performance. In this text, we first analyze the electromagnetic interference threat generator control system of transistor type may face, then design a electromagnetic protection plan for the intake, the panel and the sense organ. This work is of great significance in improving its electromagnetic protection ability and stability of performance. 展开更多
关键词 GENERATOR control System ELECTROMAGNETIC INTERFERENCE DAMAGE Analysis ELECTROMAGNETIC protection Design
下载PDF
Protection of ±500 kV HVDC Double-circuit Converter Station from Lightning Induced Overvoltage 被引量:1
17
作者 DONG Manling YUAN Zhiyong +3 位作者 LI Tianwei ZHAO Xiangen ZHANG Jiaxin HE Junjia 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期2053-2060,共8页
In order to obtain reasonable schemes of arrester in converter stations, the arrester scheme of "Xiluodu-Guangdong HVDC ± 500 kV double circuit transmission" project against lighting induced overvoltage... In order to obtain reasonable schemes of arrester in converter stations, the arrester scheme of "Xiluodu-Guangdong HVDC ± 500 kV double circuit transmission" project against lighting induced overvoltage, which was designed according to the main principle of lightning protection in converter station, is discussed. A calculation of the lighting induced overvoltage in Zhaotong converter station un- der various operation modes is performed with ATP-EMTP software, then the surge arrester configuration of the converter station is decided, and the arrester protection schemes of smoothing reactor and neutral line are studied. It is concluded that additional protection is necessary because of the relatively large gap between protected disconnecting switch and arrester of metallic return transfer bus. Plus, the smoothing reactor (SR) arrester near the valve hall could be removed to improve the scheme’s economic performance. 展开更多
关键词 高压直流输电 过电压保护 换流站 双回路 雷电感应 ATP-EMTP 平波电抗器 避雷器
下载PDF
Advancement in Wide Area Monitoring Protection and Control Using PMU’s Model in MATLAB/SIMULINK
18
作者 Waheed Ur Rahman Muhammad Ali +7 位作者 Amjad Ullah Hafeez Ur Rahman Majid Iqbal Haseeb Ahmad Adnan Zeb Zeeshan Ali M. Ahsan Shahzad Beenish Taj 《Smart Grid and Renewable Energy》 2012年第4期294-307,共14页
A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power system... A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station. 展开更多
关键词 WIDE Area MONITORING protection and control (WAMPAC) Phasor Measurement uNit (PMU) WIDE Area MONITORING (WAM) Global Positioning System (GPS) WIDE Area controlLER (WAC) Local Area controlLER (LAC) Phase Angle MONITORING (PAM) Automatic Generation control (AGC) circuit Breaker (CB) Current TRANSFORMERS (CTs) Potential TRANSFORMERS (PTs)
下载PDF
Regional Coordinated Development and Joint Prevention and Control for Environmental Protection in China in the New Era
19
作者 Wenqi YUE Sheng WANG +2 位作者 Nan SHAO Yuqing LIU Yiran ZOU 《Meteorological and Environmental Research》 CAS 2021年第4期17-20,共4页
The three important historical development stages of China from"standing up","getting rich"to"becoming strong"were analyzed deeply.Regional coordinated development policies and strategies... The three important historical development stages of China from"standing up","getting rich"to"becoming strong"were analyzed deeply.Regional coordinated development policies and strategies have also gone through the"enlightenment stage","development stage"and"mature stage".On this basis,the problems of the coordination of China s regional coordinated development and joint prevention and control for environmental protection in the new era,as well as suggestions for the next step were further analyzed. 展开更多
关键词 Regional coordinated development Joint prevention and control Environmental protection
下载PDF
The Application of Three-Dimensional Integrated Protection Technology in High Slope Control of Mountainous Highway
20
作者 Jun Han 《Frontiers Research of Architecture and Engineering》 2018年第1期1-3,共3页
In the process of China's national economy construction,the role of highway traffic is unquestionable.And with the continuous development of society and the continuous improvement of highway grade,the work of the ... In the process of China's national economy construction,the role of highway traffic is unquestionable.And with the continuous development of society and the continuous improvement of highway grade,the work of the highway slope governance become a top priority,especially for some mountainous area highway,strengthen management of slope is very critical.The emergence of three-dimensional comprehensive protection technology has created great convenience for the management of the slope of the mountainous highway,and the safety of the mountain highway has been improved effectively.In view of this,the paper focuses on the application of three-dimensional integrated protection technology in the treatment of highway high slope in mountainous areas for reference and reference. 展开更多
关键词 STEREO synthesis protection technology MOUNTAIN ROADS SLOPE control Apply
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部