期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Two-port Equivalent Circuit Model for UHVDC Converter Valves
1
作者 Ning Chen Lei Qi +3 位作者 Yi Tang Cuiyu Zhao Xiang Cui Chong Gao 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2019年第1期100-110,共11页
UHVDC converter valves during operation may experience overvoltage,which come from the AC or DC systems to which they are connected.Therefore,building an equivalent circuit model(ECM)for the converter valve to analyze... UHVDC converter valves during operation may experience overvoltage,which come from the AC or DC systems to which they are connected.Therefore,building an equivalent circuit model(ECM)for the converter valve to analyze the interlayer transient voltage distribution characteristics has important engineering significance for safe and reasonable voltage equalization methods and improving the stability of the DC system.This paper proposes a two-port equivalent circuit model for ±1100 kV converter valve based on the structure of the valve and parameter extraction methods presented.In terms of lumped parameters,integrated ECMs for valve layers are built through impedance-frequency characteristic analysis;in terms of parasitic capacitance parameters,port equivalent parasitic capacitance parameters are obtained by terminal capacitance method and iterative equivalence methods proposed in this paper.By combining integrated ECMs of valve layers and port equivalent parasitic capacitances,the two-port ECM is obtained.Simulations are carried out to test the effectiveness of the twoport ECM.Using the ECM,the voltage transmission characteristics and their influencing factors are analyzed,depending on which corresponding voltage equalization method is proposed in this paper,and the effect of this method is verified through simulation. 展开更多
关键词 Equivalent circuit model parasitic capacitance UHVDC converter valve voltage equalization method
原文传递
Design and Development of Wind-Solar Hybrid Power System with Compressed Air Energy Storage for Voltage and Frequency Regulations
2
作者 Banet Masenga Jean Byiringiro +3 位作者 Charles Kagiri Edwell Tafara Daniel Ngoma Gnoumou Aristid 《Journal of Power and Energy Engineering》 2023年第2期1-24,共24页
The intermittent nature of wind and solar photovoltaic energy systems leads to the fluctuation of power generated due to the fact that the power output is highly dependent upon local weather conditions, which results ... The intermittent nature of wind and solar photovoltaic energy systems leads to the fluctuation of power generated due to the fact that the power output is highly dependent upon local weather conditions, which results to the load shading issue that led to the voltage and frequency instability. In additional to that, the high proportions of erratic renewable energy sources can lead to erratic frequency changes which affect the grid stability. In order to reduce this effect, the energy storage system is commonly used in most wind-solar energy systems to balance the voltage and frequency instability during load variations. One of the innovative energy storage systems is the compressed air energy storage system (CAES) for wind and solar hybrid energy system and this technology is the key focus in this research study. The aim of this research was to examine the system configuration of the CAES system through modelling and experimental approach with PID controller design for regulating the voltage and frequency under different load conditions. The essential elements and the entire system have been presented in this work as thorough modelling in the MATLAB/Simulink environment for different load conditions. The developed model was tested through an experimental workbench using the developed prototype of the compressed air storage in the Siemens Lab at DeKUT and explored the consequence of the working parameters on the system proficiency and the model accuracy. The performance of the system for the developed prototype of CAES system was validated using results from an experimental workbench with MATLAB/Simulink R2022b simulation. The modeling and experimental results, shows that the frequency fluctuation and voltage drop of the developed CAES system during load variations was governed by the I/P converter using a PID_Compact controller programed in the TIA Portal V17 software and downloaded into PLC S7 1200. Based on these results, the model can be applied as a basis for the performance assessment of the compressed air energy storage system so as to be included in current technology of wind and solar hybrid energy systems. 展开更多
关键词 VOLTAGE FREQUENCY Compressed Air Energy Storage Load Variations PID Control I/P converter valve
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部