A small-scale silica gel-water adsorption system with modular adsorber,which utilizes solar energy to achieve the cogeneration of domestic air conditioning and water heating effect,is proposed and investigated in this...A small-scale silica gel-water adsorption system with modular adsorber,which utilizes solar energy to achieve the cogeneration of domestic air conditioning and water heating effect,is proposed and investigated in this paper.A heat recovery process between two adsorbers and a mass recovery process between two evaporators are adopted to improve the overall cooling and heating performance.First,the adsorption system is tested under different modes(different mass recovery,heat recovery,and cogeneration time)to determine the optimal operating conditions.Then,the cogeneration performance of domestic cooling and water heating effect is studied at different heat transfer fluid temperatures.The results show that the optimal time for cogeneration,mass recovery,and heat recovery are 600 s,40 s,and 40 s,respectively.When the inlet temperature of hot water is around 85℃,the largest cooling power and heating power are 8.25 kW and 21.94 kW,respectively.Under the condition of cooling water temperature of 35℃,the obtained maximum COP,COP,and SCP of the system are 0.59,1.39,and 184.5 W/kg,respectively.展开更多
基金supported by the Key Project of the National Natural Science Foundation of China for international academic exchanges(Grant No.51561145012)the National Natural Science Foundation of China(Grant No.51576120).
文摘A small-scale silica gel-water adsorption system with modular adsorber,which utilizes solar energy to achieve the cogeneration of domestic air conditioning and water heating effect,is proposed and investigated in this paper.A heat recovery process between two adsorbers and a mass recovery process between two evaporators are adopted to improve the overall cooling and heating performance.First,the adsorption system is tested under different modes(different mass recovery,heat recovery,and cogeneration time)to determine the optimal operating conditions.Then,the cogeneration performance of domestic cooling and water heating effect is studied at different heat transfer fluid temperatures.The results show that the optimal time for cogeneration,mass recovery,and heat recovery are 600 s,40 s,and 40 s,respectively.When the inlet temperature of hot water is around 85℃,the largest cooling power and heating power are 8.25 kW and 21.94 kW,respectively.Under the condition of cooling water temperature of 35℃,the obtained maximum COP,COP,and SCP of the system are 0.59,1.39,and 184.5 W/kg,respectively.