期刊文献+
共找到808篇文章
< 1 2 41 >
每页显示 20 50 100
Initiative Optimization Operation Strategy and Multi-objective Energy Management Method for Combined Cooling Heating and Power 被引量:4
1
作者 Feng Zhao Chenghui Zhang Bo Sun 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI 2016年第4期385-393,共9页
This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power U+0028 CCHP U+0029 with storage systems. Initially, the initiative ... This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power U+0028 CCHP U+0029 with storage systems. Initially, the initiative optimization operation strategy of CCHP system in the cooling season, the heating season and the transition season was formulated. The energy management of CCHP system was optimized by the multi-objective optimization model with maximum daily energy efficiency, minimum daily carbon emissions and minimum daily operation cost based on the proposed initiative optimization operation strategy. Furthermore, the pareto optimal solution set was solved by using the niche particle swarm multi-objective optimization algorithm. Ultimately, the most satisfactory energy management scheme was obtained by using the technique for order preference by similarity to ideal solution U+0028 TOPSIS U+0029 method. A case study of CCHP system used in a hospital in the north of China validated the effectiveness of this method. The results showed that the satisfactory energy management scheme of CCHP system was obtained based on this initiative optimization operation strategy and multi-objective energy management method. The CCHP system has achieved better energy efficiency, environmental protection and economic benefits. © 2014 Chinese Association of Automation. 展开更多
关键词 CARBON cooling cooling systems Energy efficiency Energy management heating Multiobjective optimization OPTIMIZATION Pareto principle
下载PDF
Water, Air Emissions, and Cost Impacts of Air-Cooled Microturbines for Combined Cooling, Heating, and Power Systems: A Case Study in the Atlanta Region
2
作者 Jean-Ann James Valerie M. Thomas +2 位作者 Arka Pandit Duo Li John C. Crittenden 《Engineering》 SCIE EI 2016年第4期470-480,共11页
The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the po... The increasing pace of urbanization means that cities and global organizations are looking for ways to increase energy efficiency and reduce emissions. Combined cooling, heating, and power (CCHP) systems have the potential to improve the energy generation efficiency of a city or urban region by providing energy for heating, cooling, and electricity simultaneously. The purpose of this study is to estimate the water consumption for energy generation use, carbon dioxide (CO2) and NOx emissions, and economic impact of implementing CCHP systems for five generic building types within the Atlanta metropolitan region, under various operational scenarios following the building thermal (heating and cooling) demands. Operating the CCHP system to follow the hourly thermal demand reduces CO2 emissions for most building types both with and without net metering. The system can be economically beneficial for all building types depending on the price of natural gas, the implementation of net metering, and the cost structure assumed for the CCHP system. The greatest reduction in water consumption for energy production and NOx emissions occurs when there is net metering and when the system is operated to meet the maximum yearly thermal demand, although this scenario also results in an increase in greenhouse gas emissions and, in some cases, cost. CCHP systems are more economical for medium office, large office, and multifamilv residential buildings. 展开更多
关键词 combined cooling heating and power (CCHP) Air-cooled microturbines Distributed energy generation Water for energy production Net metering
下载PDF
A Financial Approach to Evaluate an Optimized Combined Cooling, Heat and Power System 被引量:20
3
作者 Shahab Bahrami Farahbakhsh Safe 《Energy and Power Engineering》 2013年第5期352-362,共11页
Iran’s removing subsidy from energy carrier in four years ago leads to spike electricity price dramatically. This abrupt change increases the interest on distributed generation (DG) because of its several benefits su... Iran’s removing subsidy from energy carrier in four years ago leads to spike electricity price dramatically. This abrupt change increases the interest on distributed generation (DG) because of its several benefits such as lower electricity generation price. In Iran among all type of DGs, because of wide natural gas network infrastructure and several incentives that government legislated to support combined cooling, heat and power (CCHP) investors, this type of technology is more prevalent in comparison with other technologies. Between existing CCHP technologies, certain economic choices are to be taken into account. For different buildings with different load curves, suitable size and operation of CCHP should be calculated to make the project more feasible. If CCHP does not well suited for a position, then the whole energy efficiency would be plunged significantly. In this paper, a model to find the optimal size and operation of CCHP and auxiliary boiler for any users is proposed by considering an integrated view of electricity and natural gas network using GAMS software. Then this method is applying for a hospital in Tehran as a real case study. Finally, by applying COMFAR III software, useful financial parameters and sensitivity analysis are calculated. 展开更多
关键词 combined cooling heat and Power (CCHP) Energy HUB Optimal SIZE FINANCIAL Analysis
下载PDF
Multi-Objective Optimization Based on Life Cycle Assessment for Hybrid Solar and Biomass Combined Cooling,Heating and Power System
4
作者 LIU Jiejie LI Yao +1 位作者 MENG Xianyang WU Jiangtao 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第3期931-950,共20页
The complementary of biomass and solar energy in combined cooling,heating and power(CCHP)system provides an efficient solution to address the energy crisis and environmental pollutants.This work aims to propose a mult... The complementary of biomass and solar energy in combined cooling,heating and power(CCHP)system provides an efficient solution to address the energy crisis and environmental pollutants.This work aims to propose a multi-objective optimization model based on the life cycle assessment(LCA)method for the optimal design of hybrid solar and biomass system.The life-cycle process of the poly-generation system is divided into six phases to analyze energy consumption and greenhouse gas emissions.The comprehensive performances of the hybrid system are optimized by incorporating the evaluation criteria,including environmental impact in the whole life cycle,renewable energy contribution and economic benefit.The non-dominated sorting genetic algorithmⅡ(NSGA-Ⅱ)with the technique for order preference by similarity to ideal solution(TOPSIS)method is employed to search the Pareto frontier result and thereby achieve optimal performance.The developed optimization methodology is used for a case study in an industrial park.The results indicate that the best performance from the optimized hybrid system is reached with the environmental impact load reduction rate(EILRR)of 46.03%,renewable energy contribution proportion(RECP)of 92.73%and annual total cost saving rate(ATCSR)of35.75%,respectively.By comparing pollutant-eq emissions of different stages,the operation phase emits the largest pollutant followed by the phase of raw material acquisition.Overall,this study reveals that the proposed multi-objective optimization model integrated with LCA method delivers an alternative path for the design and optimization of more sustainable CCHP system. 展开更多
关键词 combined cooling heating and power system solar-biomass multi-objective optimization life cycle assessment optimal design
原文传递
Thermodynamic Analysis of Solid Oxide Fuel Cell Based Combined Cooling,Heating,and Power System Integrated with Solar-Assisted Electrolytic Cell 被引量:2
5
作者 GAO Yuefen YAO Wenqi +1 位作者 WANG Jiangjiang CUI Zhiheng 《Journal of Thermal Science》 SCIE EI CAS CSCD 2023年第1期93-108,共16页
Syngas fuel such as hydrogen and carbon monoxide generated by solar energy is a promising method to use solar energy and overcome its fluctuation effectively.This study proposes a combined cooling,heating,and power sy... Syngas fuel such as hydrogen and carbon monoxide generated by solar energy is a promising method to use solar energy and overcome its fluctuation effectively.This study proposes a combined cooling,heating,and power system using the reversible solid oxide fuel cell assisted by solar energy to produce solar fuel and then supply energy products for users during the period without solar radiation.The system runs a solar-assisted solid oxide electrolysis cell mode and a solid oxide fuel cell mode.The thermodynamic models are constructed,and the energetic and exergetic performances are analyzed.Under the design work conditions,the SOEC mode’s overall system energy and exergy efficiencies are 19.0%and 20.5%,respectively.The electrical,energy and exergy efficiencies in the SOFC mode are 51.4%,71.3%,and 45.2%,respectively.The solid oxide fuel cell accounts for 60.0%of total exergy destruction,caused by the electrochemical reactions’thermodynamic irreversibilities.The increase of operating temperature of solid oxide fuel cell from 800℃to 1050℃rises the exergy and energy efficiencies by 11.3%and 12.3%,respectively.Its pressure from 0.2 to 0.7 MPa improves electrical efficiency by 13.8%while decreasing energy and exergy efficiencies by 5.2%and 6.0%,respectively. 展开更多
关键词 solid oxide electrolysis cell(SOEC) solid oxide fuel cell(SOFC) solar energy combined cooling heating and power(CCHP) exergy analysis
原文传递
Feasibility Analysis of the Operation Strategies for Combined Cooling, Heating and Power Systems (CCHP) based on the Energy-Matching Regime 被引量:1
6
作者 FENG Lejun DAI Xiaoye +1 位作者 MO Junrong SHI Lin 《Journal of Thermal Science》 SCIE EI CAS CSCD 2020年第5期1149-1164,共16页
Although numerous studies have considered the two traditional operation strategies:following the electric load(FEL)and following the thermal load(FTL),for combined cooling,heating,and power(CCHP)systems in different c... Although numerous studies have considered the two traditional operation strategies:following the electric load(FEL)and following the thermal load(FTL),for combined cooling,heating,and power(CCHP)systems in different case studies,there are limited theoretical studies on the quantification methods to assess the feasibility of these two strategies in different load demands scenarios.Therefore,instead of a case study,we have undertaken a theoretical analysis of the suitable application scenarios for FEL and FTL strategies based on the energy-matching performance between systems'provision and users'demands.To compare the calculation models of energy saving rate(ESR)for FEL and FTL strategies in the left and right sub-regions of the energy-supply curve,a comprehensive parameter(^)that combines three inherently influential factors(off-design operation parameter,energy-matching parameter,and install capacity coefficient)is defined to determine the optimal installed capacity and feasibility of FEL or FTL strategies quantitatively.The results indicate that greater value of x contribute to a better energy saving performance,and FEL strategy shows better performance than FTL in most load demands scenarios,and the optimal installed capacity occurs when the load demand points were located in different regions of the energy-supply curve.Finally,taking a hotel in Beijing as an example,the value of the optimal install capacity coefficient is 0.845 and the FEL strategy is also suggested,and compared to the maximum install capacity,the average values of the ESR on a typical summer day,transition season,and winter can be enhanced by 3.9%,8.8%,and 1.89%,respectively. 展开更多
关键词 combined cooling heating and power systems(CCHP) energy-matching performance operation strategies comprehensive parameter energy saving performance
原文传递
Energetic, economic, and environmental analysis of solid oxide fuel cell-based combined cooling, heating, and power system for cancer care hospital 被引量:1
7
作者 Ahmad K.Sleiti Wahib AAl-Ammari +1 位作者 Raiha Arshad Tarek EI Mekkawy 《Building Simulation》 SCIE EI CSCD 2022年第8期1437-1454,共18页
In this study,energetic,economic,and environmental analysis of solid oxide fuel cell-based combined cooling,heating,and power(SOFC-CCHP)system is proposed for a cancer care hospital building.The energy required for th... In this study,energetic,economic,and environmental analysis of solid oxide fuel cell-based combined cooling,heating,and power(SOFC-CCHP)system is proposed for a cancer care hospital building.The energy required for the hospital power,cooling,and heating demands was obtained based on real and detailed field data,which could serve as a reference for future works in the field.These data with a 3D model for the hospital building are constructed and created in eQUEST software to precisely calculate the energy demands of the existing system(baseline case).Then,energetic,economic,and environmental models were developed to compare and assess the performance of the proposed SOFC-CCHP system.The results show that the proposed system can cover about 49% to 77% of the power demand of the hospital with an overall efficiency of 78.3%.Also,the results show that the levelized cost of electricity of the system and its payback period at the designed capacity of the SOFC is 0.087S/kWh and 10 years,respectively.Furthermore,compared to the baseline system of the hospital,the SOFC-CCHP reduces the CO_(2) emission by 89% over the year.The sensitivity analysis showed that a maximum SOFC efficiency of 52%and overall efficiency of 80%are achieved at cell operating temperature of 1027℃ and fuel utilization factor of 0.85. 展开更多
关键词 combined cooling heating and power solid oxide fuel cell hospital power demand CO_(2)emissions levelized cost of electricity(LCOE)
原文传递
Optimization of Operation Strategies for a Combined Cooling, Heating and Power System based on Adiabatic Compressed Air Energy Storage 被引量:9
8
作者 CHEN Shang ZHU Tong +2 位作者 GAN Zhongxue ZHU Xiaojun LIU Liuchen 《Journal of Thermal Science》 SCIE EI CAS CSCD 2020年第5期1135-1148,共14页
The fluctuations of renewable energy and various energy demands are crucial issues for the optimal design and operation of combined cooling,heating and power(CCHP)system.In this paper,a novel CCHP system is simulated ... The fluctuations of renewable energy and various energy demands are crucial issues for the optimal design and operation of combined cooling,heating and power(CCHP)system.In this paper,a novel CCHP system is simulated with advanced adiabatic compressed air energy storage(AA-CAES)technology as a join to connect with wind energy generation and an internal-combustion engine(ICE).The capital cost of utilities,energy cost,environmental protection cost and primary energy savings ratio(P E S R)are used as system performance indicators.To fulfill the cooling,heating and power requirements of a district and consider the thermal-electric coupling of ICE and AA-CAES in CCHP system,three operation strategies are established to schedule the dispatch of AA-CAES and ICE:ICE priority operation strategy,CAES priority operation strategy and simultaneous operation strategy.Each strategy leads the operation load of AA-CAES or ICE to improve the energy supply efficiency of the system.Moreover,to minimize comprehensive costs and maximize the P E S R,a novel optimization algorithm based on intelligent updating multi-objective differential evolution(MODE)is proposed to solve the optimization model.Considering the multi-interface characteristic and active management ability of the ICE and AA-CAES,the economic benefits and energy efficiency of the three operation strategies are compared by the simulation with the same system configuration.On a typical summer day,the simultaneous strategy is the best solution as the total cost is 3643 USD and the P E S R is 66.1%,while on a typical winter day,the ICE priority strategy is the best solution as the total cost is 4529 USD and the P E S R is 64.4%.The proposed methodology provides the CCHP based AA-CAES system with a better optimized operation. 展开更多
关键词 combined cooling heating and power(CCHP)system advanced adiabatic compressed air energy storage(AA-CAES) OPTIMIZATION
原文传递
Liquid Air Energy Storage for Decentralized Micro Energy Networks with Combined Cooling,Heating,Hot Water and Power Supply 被引量:1
9
作者 SHE Xiaohui ZHANG Tongtong +5 位作者 PENG Xiaodong WANG Li TONG Lige LUO Yimo ZHANG Xiaosong DING Yulong 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第1期1-17,共17页
Liquid air energy storage(LAES)has been regarded as a large-scale electrical storage technology.In this paper,we first investigate the performance of the current LAES(termed as a baseline LAES)over a far wider range o... Liquid air energy storage(LAES)has been regarded as a large-scale electrical storage technology.In this paper,we first investigate the performance of the current LAES(termed as a baseline LAES)over a far wider range of charging pressure(1 to 21 MPa).Our analyses show that the baseline LAES could achieve an electrical round trip efficiency(e RTE)above 60%at a high charging pressure of 19 MPa.The baseline LAES,however,produces a large amount of excess heat particularly at low charging pressures with the maximum occurred at~1 MPa.Hence,the performance of the baseline LAES,especially at low charging pressures,is underestimated by only considering electrical energy in all the previous research.The performance of the baseline LAES with excess heat is then evaluated which gives a high e RTE even at lower charging pressures;the local maximum of 62%is achieved at~4 MPa.As a result of the above,a hybrid LAES system is proposed to provide cooling,heating,hot water and power.To evaluate the performance of the hybrid LAES system,three performance indicators are considered:nominal-electrical round trip efficiency(ne RTE),primary energy savings and avoided carbon dioxide emissions.Our results show that the hybrid LAES can achieve a high ne RTE between 52%and 76%,with the maximum at~5 MPa.For a given size of hybrid LAES(1 MW×8 h),the primary energy savings and avoided carbon dioxide emissions are up to 12.1 MWh and 2.3 ton,respectively.These new findings suggest,for the first time,that small-scale LAES systems could be best operated at lower charging pressures and the technologies have a great potential for applications in local decentralized micro energy networks. 展开更多
关键词 liquid air energy storage cryogenic energy storage micro energy grids combined heating cooling and power supply heat pump
原文传递
WHR (Waste Heat Technology) Method in Tri-generation Model 被引量:2
10
作者 Imrich Discantiny 《Journal of Geological Resource and Engineering》 2015年第1期37-41,共5页
This paper is focused on description of cool production in using WHR (Waste Heat Technology) Technology-a new method of centralized production of heat by using the waste heat from generated exhaust gas, which has be... This paper is focused on description of cool production in using WHR (Waste Heat Technology) Technology-a new method of centralized production of heat by using the waste heat from generated exhaust gas, which has been in 2009 developed and operated by companies HELORO s.r.o, and COMTHERM s.r.o. 展开更多
关键词 NG (natural gas) GB (gas boiler) CHP combined heat power) CHPC combined heat power cool CGU(co-generation unit) ABSU (absorption unit) TC (thermal condenser) HE1 HE2 heat exchanger).
下载PDF
A Comprehensive Study of a Low-Grade Heat-Driven Cooling and Power System Based on Heat Current Method
11
作者 ZHAO Tian XU Ronghong +4 位作者 XIN Yonglin HE Kelun MA Huan YUAN Mengdi CHEN Qun 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第4期1523-1541,共19页
Combined cooling and power(CCP)system driven by low-grade heat is promising for improving energy efficiency.This work proposes a CCP system that integrates a regenerative organic Rankine cycle(RORC)and an absorption c... Combined cooling and power(CCP)system driven by low-grade heat is promising for improving energy efficiency.This work proposes a CCP system that integrates a regenerative organic Rankine cycle(RORC)and an absorption chiller on both driving and cooling fluid sides.The system is modeled by using the heat current method to fully consider nonlinear heat transfer and heat-work conversion constraints and resolve its behavior accurately.The off-design system simulation is performed next,showing that the fluid inlet temperatures and flow rates of cooling water as well as RORC working fluid strongly affect system performance.The off-design operation even becomes infeasible when parameters deviate from nominal values largely due to limited heat transfer capability of components,highlighting the importance of considering heat transfer constraints via heat current method.Design optimization aiming to minimize the total thermal conductance is also conducted.RORC efficiency increases by 7.9%and decreases by 12.4%after optimization,with the hot fluid inlet temperature increase from 373.15 to 403.15 K and mass flow rate ranges from 10 to 30 kg/s,emphasizing the necessity of balancing system cost and performance. 展开更多
关键词 combined cooling and power system organic Rankine cycle absorption chiller cascade heat utilization heat current method off-design analysis
原文传递
Comprehensive power-supply planning for active distribution system considering cooling,heating and power load balance 被引量:24
12
作者 Xinwei SHEN Yingduo HAN +3 位作者 Shouzhen ZHU Jinghong ZHENG Qingsheng LI Jing NONG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2015年第4期485-493,共9页
An active distribution system power-supply planning model considering cooling,heating and power load balance is proposed in this paper.A regional energy service company is assumed to be in charge of the investment and... An active distribution system power-supply planning model considering cooling,heating and power load balance is proposed in this paper.A regional energy service company is assumed to be in charge of the investment and operation for the system in the model.The expansion of substations,building up distributed combined cooling,heating and power(CCHP),gas heating boiler(GHB)and air conditioner(AC)are included as investment planning options.In terms of operation,the load scenarios are divided into heating,cooling and transition periods.Also,the extreme load scene is included to assure the power supply reliability of the system.Numerical results demonstrate the effectiveness of the proposed model and illustrate the economic benefits of applying distributed CCHP in regional power supply on investment and operation. 展开更多
关键词 Active distribution system combined cooling heating and power(CCHP) Power-supply planning Load balance
原文传递
Investigation of the Conjugate Heat Transfer and Flow Field for a Flat Plate with Combined Film and Impingement Cooling 被引量:3
13
作者 FU Jinglun CAO Ying +1 位作者 ZHANG Chao ZHU Junqiang 《Journal of Thermal Science》 SCIE EI CAS CSCD 2020年第4期955-971,共17页
Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was unde... Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was undertaken for a flat plate with combined film cooling and impingement cooling. An experiment on conjugate heat transfer of a flat plate with combined film and impingement cooling was performed to validate the code. Then the effects of several parameters including Biot number, blowing ratio, film hole shape and impingement hole diameter on the overall cooling effectiveness were numerically studied. The results show that for a specific combined cooling scheme and a given blowing ratio, the coolant potential can be reasonably allocated to the internal and the external cooling to achieve the overall cooling effectiveness. As the blowing ratio increases, the overall cooling effectiveness trends to reach a maximum value. For different film hole geometrical, the maximum values of the overall cooling effectiveness at high blowing ratio approximate to the same value. At a given mass flow rate of coolant, the increase of the impingement hole diameter leads to the reduction of the overall cooling effectiveness. 展开更多
关键词 conjugate heat transfer combined film and impingement cooling overall cooling effectiveness Biot number blowing ratio
原文传递
A Dual-driven Intelligent Combination Control of Heat Pipe Space Cooling System 被引量:4
14
作者 LI Yunze LI Mingmin LEE Kok Meng 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2012年第4期566-574,共9页
Effective thermal control systems are essential for reliable operation of spacecraft.A dual-driven intelligent combination control strategy is proposed to improve the temperate control and heat flux tracking effects.B... Effective thermal control systems are essential for reliable operation of spacecraft.A dual-driven intelligent combination control strategy is proposed to improve the temperate control and heat flux tracking effects.Both temperature regulation and heat flux tracking errors are employed to generate the final control action;their contributions are adaptively adjusted by a fuzzy fusing policy of control actions.To evaluate the control effects,describe a four-nodal mathematical model for analyzing the dynamic characteristics of the controlled heat pipe space cooling system(HP-SCS) consisting of an aluminum-ammonia heat pipe and a variable-emittance micro-electromechanical-system(MEMS) radiator.This dynamical model calculates the mass flow-rate and condensing pressure of the heat pipe working fluid directly from the systemic nodal temperatures,therefore,it is more suitable for control engineering applications.The closed-loop transient performances of four different control schemes have been numerically investigated.The results conclude that the proposed intelligent combination control scheme not only improves the thermal control effects but also benefits the safe operation of HP-SCS. 展开更多
关键词 heat pipe space cooling system dynamic modeling intelligent combination control micro-electromechanical-system
原文传递
A multi agent-based optimal control method for combined cooling and power systems with thermal energy storage
15
作者 Zihao Wang Chaobo Zhang +1 位作者 Hongbo Li Yang Zhao 《Building Simulation》 SCIE EI CSCD 2021年第6期1709-1723,共15页
Combined cooling,heating and power(CCHP)systems have been considered as a potential energy saving technology for buildings due to their high energy efficiency and low carbon emission.Thermal energy storage(TES)can imp... Combined cooling,heating and power(CCHP)systems have been considered as a potential energy saving technology for buildings due to their high energy efficiency and low carbon emission.Thermal energy storage(TES)can improve the energy efficiency of CCHP systems,since they reduce the mismatch between the energy supply and demand.However,it also increases the complexity of operation optimization of CCHP systems.In this study,a multi-agent system(MAS)-based optimal control method is proposed to minimize the operation cost of CCHP systems combined with TES.Four types of agents,i.e.,coordinator agents,building agents,energy management agents and optimization agents,are implemented in the MAS to cooperate with each other.The operation optimization problem is solved by the genetic algorithm.A simulated system is utilized to validate the performance of the proposed method.Results show that the operation cost reductions of 10.0%on a typical summer day and 7.7%on a typical spring day are achieved compared with a rule-based control method.A sensitivity analysis is further performed and results show that the optimal operation cost does not change obviously when the rated capacity of TES exceeds a threshold. 展开更多
关键词 multi-agent systems distributed control-operation optimization demand response combined cooling heating and power system thermal energy storage
原文传递
空冷机组空气-烟气余热利用综合分析 被引量:15
16
作者 杨勇平 许诚 +2 位作者 徐钢 方亚雄 吴影 《动力工程学报》 CAS CSCD 北大核心 2013年第11期907-912,共6页
在分析空冷机组运行特点的基础上,提出了一种空气-烟气余热联合回收系统,即空冷岛出口的热空气作为锅炉燃烧用风,进入空气预热器被加热,同时在锅炉尾部加装低温省煤器,加热低压凝结水,以节省汽轮机抽汽量.以某典型600MW亚临界直接空冷... 在分析空冷机组运行特点的基础上,提出了一种空气-烟气余热联合回收系统,即空冷岛出口的热空气作为锅炉燃烧用风,进入空气预热器被加热,同时在锅炉尾部加装低温省煤器,加热低压凝结水,以节省汽轮机抽汽量.以某典型600MW亚临界直接空冷机组为例,分析了空气-烟气余热联合回收系统的热力学特性和节能效果.结果表明:在典型工况下,空气预热器入口温度可提高约25K,机组供电煤耗降低约1.93g/(kW·h),年节约标准煤约7 000t,节约燃料费700余万元(按机组年运行5 500h,标准煤价格为1 000元/t计算),经济效益显著. 展开更多
关键词 空冷机组 余热利用 空气-烟气余热联合回收系统 热力学分析 节能效果
下载PDF
轴向取向组织BFe10-1-1管材冷轧加工过程中组织、织构与力学性能的变化 被引量:14
17
作者 梅俊 刘新华 +1 位作者 姜雁斌 谢建新 《中国有色金属学报》 EI CAS CSCD 北大核心 2012年第9期2529-2538,共10页
采用热冷组合铸型(HCCM)水平连铸技术制备具有轴向取向组织的BFe10-1-1管材,对管材进行冷轧加工,研究管材的组织、织构与性能的变化。结果表明:HCCM水平连铸管材不需铣面便可直接冷轧加工;无中间退火的累积冷轧变形量可达80%以... 采用热冷组合铸型(HCCM)水平连铸技术制备具有轴向取向组织的BFe10-1-1管材,对管材进行冷轧加工,研究管材的组织、织构与性能的变化。结果表明:HCCM水平连铸管材不需铣面便可直接冷轧加工;无中间退火的累积冷轧变形量可达80%以上;冷轧管表面质量好,轧制过程中无裂纹、裂口和飞边等缺陷;随着变形量的增加,取向组织晶粒内一次枝晶主干间距逐渐减小,由铸态的100-200μm减小到变形量60%时的10-20μm;当冷变形量为60%时,组织中可观察到剪切带,当冷变形量为80%时,组织呈波浪状,枝晶、晶界很难辨认;冷轧过程中管材由铸造织构(主要取向{012}(621))、经过渡型织构{012}(100)(变形量为20%)和{057}〈372〉(变形量为40%),转变为变形量为60%时的Cube织构,当变形量为80%时转变为G织构;随着变形量的增加,冷轧管的抗拉强度和硬度分别由铸态的234MPa和70HV增加至变形量80%时的372UPa和152HV,伸长率由铸态的46.5%降低至80%变形量时的13%。 展开更多
关键词 BFe10合金 水平连铸 热冷组合铸型 冷轧管 轧制织构
下载PDF
Parametric optimization of power system for a micro-CCHP system 被引量:2
18
作者 李应林 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期297-301,共5页
The universal mathematical model of an engine is established,and an economical zone,in which an engine mainly provides medium output load at medium speed,is presented.Based on the experimental data and the universal m... The universal mathematical model of an engine is established,and an economical zone,in which an engine mainly provides medium output load at medium speed,is presented.Based on the experimental data and the universal model of such an engine above,a mathematical model of a refitted engine is provided.The boundary of the corresponding economical zone is further demarcated,and the optimal operating curve and the operating point of the engine are analyzed.Then,the energy transforming models of the power system are established in the mode of cooling,heating and power(MCHP),the mode of heating and power(MHP)and the mode of electricity powering(MEP).The parameter matching of the power system is optimized according to the transmission ratios of the gear box in the power distribution system.The results show that,in the MCHP,the speed transmission ratio of the engine to the gear box(ies)and the speed transmission ratio of the motor to the gear box(ims)are defined as 2.9 and 1,respectively;in the MHP,when the demand load of the power system is less than the low critical load of the economical zone,the speed transmission ratio of the motor to the engine(ime)is equal to 1,and when the demand load of the power system exceeds the low critical load of the economical zone,ime equals 0.85;in the MEP,the optimal value of ims is defined as 2.5. 展开更多
关键词 combined cooling heating and power distributed energy supply battery bank ENGINE
下载PDF
地源热泵供热水-空调冷热联供综合系统的实验研究 被引量:7
19
作者 胡映宁 林俊 赵玲玲 《流体机械》 CSCD 北大核心 2008年第12期57-61,共5页
介绍了作者自主设计实施的地源热泵热水-空调冷热联供系统,运用单因素方法,研究地埋管总深度、地埋管及空调的循环介质流量等对热泵系统运行特性的影响,提出土壤源制热水和冷热联供两种工况下的合理运行方式。研究结果表明土壤源制热水... 介绍了作者自主设计实施的地源热泵热水-空调冷热联供系统,运用单因素方法,研究地埋管总深度、地埋管及空调的循环介质流量等对热泵系统运行特性的影响,提出土壤源制热水和冷热联供两种工况下的合理运行方式。研究结果表明土壤源制热水间歇运行时既满足生活热水需求,又避免土壤源长期过度取热;夏季采用空调冷凝热为建筑制冷的同时制取生活热水,机组综合能效比达1:7以上,使热水系统全年运行成本大大降低。 展开更多
关键词 地源热泵 土壤换热器 冷热联供 空调冷凝热 能效比
下载PDF
上海地区不同类型建筑的CCHP-ORC系统评价与分析 被引量:11
20
作者 刘豪 朱彤 张涛 《中国电机工程学报》 EI CSCD 北大核心 2016年第12期3198-3205,共8页
将传统的分供能源(SP)系统作为基准,以一次能源消耗量、年总费用和碳排放量构成的综合指标为优化目标,根据相关约束条件建立线性优化模型,分析评价了含有机朗肯循环(ORC)的冷热电联供(CCHP)能源系统在不同建筑类型的应用。对上海5种典... 将传统的分供能源(SP)系统作为基准,以一次能源消耗量、年总费用和碳排放量构成的综合指标为优化目标,根据相关约束条件建立线性优化模型,分析评价了含有机朗肯循环(ORC)的冷热电联供(CCHP)能源系统在不同建筑类型的应用。对上海5种典型建筑进行研究,计算结果表明,相对于分供系统,商业和办公建筑等在使用CCHP系统后可提高能源系统的综合性能,但由于这种建筑的特点是热电比低、用电量大,内燃机在过渡季节会有大量过剩的余热无法合理利用,加入ORC系统后,能源系统的综合性能会有明显的改善;对于酒店和医院等热电比高、用热(冷)量大等特点的建筑,ORC系统的加入,对原有CCHP系统的综合性能影响较小。 展开更多
关键词 分布式能源系统 冷热电联供 有机朗肯循环 热电比 优化设计 评价指标
下载PDF
上一页 1 2 41 下一页 到第
使用帮助 返回顶部