The effect of solidification cooling rate on the size and distribution of inclusions in 12%Cr stainless steel was investigated. A wide range of solidification cooling rates(from 0.05 to 106 K·s^-1) was achieved...The effect of solidification cooling rate on the size and distribution of inclusions in 12%Cr stainless steel was investigated. A wide range of solidification cooling rates(from 0.05 to 106 K·s^-1) was achieved using various solidification processes, including conventional casting, laser remelting, and melt spinning. The size and distribution of inclusions in the steel were observed and statistically collected. For comparison, mathematical models were used to calculate the sizes of inclusions at different solidification cooling rates. Both the statistical size determined from observations and that predicted from calculations tended to decrease with increasing cooling rate; however, the experimental and calculated results did not agree well with each other at excessively high or low cooling rate. The reasons for this discrepancy were theoretically analyzed. For the size distribution of inclusions, the effect of cooling rate on the number densities of large-sized(〉 2 μm) inclusions and small-sized(≤ 2 μm) inclusions were distinct. The number density of inclusions larger than 1 μm was not affected when the cooing rate was less than or equal to 6 K·s^-1 because inclusion precipitation was suppressed by the increased cooling rate.展开更多
The flow field and heat transfer of the strip surface due to the twin slot vertical jet impingement were investigated using the ANSYS FLUENT.The RNG k-ε model was carried out in the turbulent calculation.Systematic p...The flow field and heat transfer of the strip surface due to the twin slot vertical jet impingement were investigated using the ANSYS FLUENT.The RNG k-ε model was carried out in the turbulent calculation.Systematic parametric research was conducted by varying the jet velocity of nozzle exit(V=5 m/s,7.5 m/s,10 m/s),the temperature of cooling water(T_w=280 K,300 K),the normalized spacing from the nozzle to the strip surface(H=10,15,20,33),and the normalized spacing from the nozzle to nozzle centerline(W=0,15,30).The velocity streamline of the flow domain and the general trend of the distribution of the local Nusselt number on the impingement surface of strip were obtained.The result indicate that,the average Nusselt number increases by about70%(90%) as the jet velocity is increased from 5 m/s to 7.5 m/s(from 7.5 m/s to 10 m/s),and T_w,Hand//have minimal effect on it.While the valley Nusselt number decreases by about 10%-43%with the increase of H and W.The functional relationship between the average Nusselt number and the systematic parameters is derived by the least square regression method.展开更多
基金financially supported by the National Basic Research Program of China (No. 2011CB012900)
文摘The effect of solidification cooling rate on the size and distribution of inclusions in 12%Cr stainless steel was investigated. A wide range of solidification cooling rates(from 0.05 to 106 K·s^-1) was achieved using various solidification processes, including conventional casting, laser remelting, and melt spinning. The size and distribution of inclusions in the steel were observed and statistically collected. For comparison, mathematical models were used to calculate the sizes of inclusions at different solidification cooling rates. Both the statistical size determined from observations and that predicted from calculations tended to decrease with increasing cooling rate; however, the experimental and calculated results did not agree well with each other at excessively high or low cooling rate. The reasons for this discrepancy were theoretically analyzed. For the size distribution of inclusions, the effect of cooling rate on the number densities of large-sized(〉 2 μm) inclusions and small-sized(≤ 2 μm) inclusions were distinct. The number density of inclusions larger than 1 μm was not affected when the cooing rate was less than or equal to 6 K·s^-1 because inclusion precipitation was suppressed by the increased cooling rate.
基金Project(2012 BAF04B01)Supported by the National Science and Technology Pillar Program during the Twelfth Five-year Plan of China
文摘The flow field and heat transfer of the strip surface due to the twin slot vertical jet impingement were investigated using the ANSYS FLUENT.The RNG k-ε model was carried out in the turbulent calculation.Systematic parametric research was conducted by varying the jet velocity of nozzle exit(V=5 m/s,7.5 m/s,10 m/s),the temperature of cooling water(T_w=280 K,300 K),the normalized spacing from the nozzle to the strip surface(H=10,15,20,33),and the normalized spacing from the nozzle to nozzle centerline(W=0,15,30).The velocity streamline of the flow domain and the general trend of the distribution of the local Nusselt number on the impingement surface of strip were obtained.The result indicate that,the average Nusselt number increases by about70%(90%) as the jet velocity is increased from 5 m/s to 7.5 m/s(from 7.5 m/s to 10 m/s),and T_w,Hand//have minimal effect on it.While the valley Nusselt number decreases by about 10%-43%with the increase of H and W.The functional relationship between the average Nusselt number and the systematic parameters is derived by the least square regression method.