The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easi...The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easily calculate the power factor,and Voltage controller in the microcontroller to determine whether input the compensation capacitance according to the size of power factor,the paper also analyzes the principle of capacitance compensation and calculation method. Dynamic compensation for the entire process is quick and accurate.展开更多
The on-line coordinated control strategy among multi-voltage controls is important to keep voltage security in post-fault systems. Based on the wide area measuring information, the energy function, which can qualify t...The on-line coordinated control strategy among multi-voltage controls is important to keep voltage security in post-fault systems. Based on the wide area measuring information, the energy function, which can qualify the impacts of the different control actions on voltage of different nodes, is proposed. And then, considering the impacts of different control actions on the node voltage being treated as a weight matrix, the energy margin is used as the objective function and the reactive power margin is innovatively used as the constraint to regulate the control actions globally according to the weight values. At last, the objective functions are solved to get the optimal global coordinated control strategies. The proposed method is identified in an IEEE-30 Bus system and the simulation results show that it effectively improves the voltage stability.展开更多
Microgrid (MG) systems effectively integrate a generation mix of solar, wind, and other renewable energy resources. The intermittent nature of renewable resources and the unpredictable weather conditions contribute la...Microgrid (MG) systems effectively integrate a generation mix of solar, wind, and other renewable energy resources. The intermittent nature of renewable resources and the unpredictable weather conditions contribute largely to the unreliability of microgrid real-time operation. This paper investigates the behavior of microgrid for different intermittent scenarios of photovoltaic generation in real-time. Reactive power coordination control and load shedding mechanisms are used for reliable operation and are implemented using OPAL-RT simulator integrated with Matlab. In an islanded MG, load shedding can be an effective mechanism to maintain generation-load balance. The microgrid of the German Jordanian University (GJU) is used for illustration. The results show that reactive power coordination control not only stabilizes the MG operation in real-time but also reduces power losses on transmission lines. The results also show that the power losses at some substations are reduced by a range of 6% - 9.8%.展开更多
以静止无功发生器(static var generator,SVG)为例,针对构网型逆变器和SVG并联系统的电压稳定性问题,提出构网型逆变器与SVG并联系统无功功率协调控制策略。将并联系统的运行状态总结为四种工况,通过工况识别、无功补偿量计算、无功功...以静止无功发生器(static var generator,SVG)为例,针对构网型逆变器和SVG并联系统的电压稳定性问题,提出构网型逆变器与SVG并联系统无功功率协调控制策略。将并联系统的运行状态总结为四种工况,通过工况识别、无功补偿量计算、无功功率分配策略、工况切换,来协调不同工况下构网型逆变器与SVG注入公共耦合点的无功功率,使并联系统在各种情况下均可稳定可靠工作。在MATLAB中搭建模型并进行仿真,结果表明所提控制策略可以实现工况的快速识别与切换、无功补偿量的计算、无功功率的分配,以及对公共耦合点电压的快速支撑。展开更多
文摘The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easily calculate the power factor,and Voltage controller in the microcontroller to determine whether input the compensation capacitance according to the size of power factor,the paper also analyzes the principle of capacitance compensation and calculation method. Dynamic compensation for the entire process is quick and accurate.
基金supported by the National Natural Science Foundation of China under Grant No.51007006the Fundamental Research Funds for the Central Universities under Grant No.ZYGX2012J159
文摘The on-line coordinated control strategy among multi-voltage controls is important to keep voltage security in post-fault systems. Based on the wide area measuring information, the energy function, which can qualify the impacts of the different control actions on voltage of different nodes, is proposed. And then, considering the impacts of different control actions on the node voltage being treated as a weight matrix, the energy margin is used as the objective function and the reactive power margin is innovatively used as the constraint to regulate the control actions globally according to the weight values. At last, the objective functions are solved to get the optimal global coordinated control strategies. The proposed method is identified in an IEEE-30 Bus system and the simulation results show that it effectively improves the voltage stability.
文摘Microgrid (MG) systems effectively integrate a generation mix of solar, wind, and other renewable energy resources. The intermittent nature of renewable resources and the unpredictable weather conditions contribute largely to the unreliability of microgrid real-time operation. This paper investigates the behavior of microgrid for different intermittent scenarios of photovoltaic generation in real-time. Reactive power coordination control and load shedding mechanisms are used for reliable operation and are implemented using OPAL-RT simulator integrated with Matlab. In an islanded MG, load shedding can be an effective mechanism to maintain generation-load balance. The microgrid of the German Jordanian University (GJU) is used for illustration. The results show that reactive power coordination control not only stabilizes the MG operation in real-time but also reduces power losses on transmission lines. The results also show that the power losses at some substations are reduced by a range of 6% - 9.8%.
文摘以静止无功发生器(static var generator,SVG)为例,针对构网型逆变器和SVG并联系统的电压稳定性问题,提出构网型逆变器与SVG并联系统无功功率协调控制策略。将并联系统的运行状态总结为四种工况,通过工况识别、无功补偿量计算、无功功率分配策略、工况切换,来协调不同工况下构网型逆变器与SVG注入公共耦合点的无功功率,使并联系统在各种情况下均可稳定可靠工作。在MATLAB中搭建模型并进行仿真,结果表明所提控制策略可以实现工况的快速识别与切换、无功补偿量的计算、无功功率的分配,以及对公共耦合点电压的快速支撑。