To mitigate consequences of core melting,an ex-vessel core catcher is investigated in this study.Instructions should be obeyed to cool down the corium caused by core melting.The corium destroys the reactor containment...To mitigate consequences of core melting,an ex-vessel core catcher is investigated in this study.Instructions should be obeyed to cool down the corium caused by core melting.The corium destroys the reactor containment and causes radioactive materials to be released into the environment if it does not cool down well.It is important to build a core catcher system for the reception,localization,and cool down of the molten corium during a severe accident resulting from core melting.In this study,the role of a core catcher in the VVER-1000/v528 reactor containment during a station black out(SBO)accident is evaluated using the MELCOR1.8.6 code.In addition,parametric analyses of the SBO for(i)SBO accidents with emergency core cooling system(ECCS)operation,and(ii)without ECCS operation are performed.Furthermore,thermal–hydraulic analyses in dry and wet cavities with/without water are conducted.The investigations include the reduction of gases resulting from molten–corium–concrete interactions(H_(2),CO,CO_(2)).Core melting,gas production,and the pressure/temperature in the reactor containment are assessed.Additionally,a full investigation pertaining to gas release(H_(2),CO,CO_(2))and the pressure/temperature of the core catcher is performed.Based on MELCOR simulations,a core cavity and a perimeter water channel are the best options for corium cooling and a lower radionuclide release.This simulation is also theoretically investigated and discussed herein.The simulation results show that the core catcher system in addition to an internal sacrificial material reduces the containment pressure from 689 to 580 kPa and the corresponding temperature from 394 to 380 K.Furthermore,it is observed that the amount of gases produced,particularly hydrogen,decreased from 1698 to 1235 kg.Moreover,the presence of supporting systems,including an ECCS with a core catcher,prolonged the core melting time from 16,430 to 28,630 s(in an SBO accident)and significantly decreased the gases produced.展开更多
Steam explosion is one of the crucial and poorly understood phenomena which may occur during severe accident scenario and may lead to containment failure. In spite of several experimental and analytical studies, the r...Steam explosion is one of the crucial and poorly understood phenomena which may occur during severe accident scenario and may lead to containment failure. In spite of several experimental and analytical studies, the root cause of steam explosion has not been understood. Recent claims in the literature suggest that the presence of fine fragmentation during steam explosion causes its occurrence. In order to investigate this and understand the root cause of steam explosion, series of experiments were performed with 50 g to 2500 g of CaO-B<sub>2</sub>O<sub>3</sub>, a corium simulant in 4.5 litre of water. It was observed that steam explosion may occur even in the absence of fine fragments, which is contrary to the claims in the literature. To investigate further, conversion efficiency analysis was performed. This suggested that the amount of thermal energy converted to mechanical energy is more important deciding factor in explaining the occurrence of steam explosion. The present study discusses the importance of conversion efficiency in deciding steam explosion and also gives a new perspective to look at steam explosion phenomenology.展开更多
文摘To mitigate consequences of core melting,an ex-vessel core catcher is investigated in this study.Instructions should be obeyed to cool down the corium caused by core melting.The corium destroys the reactor containment and causes radioactive materials to be released into the environment if it does not cool down well.It is important to build a core catcher system for the reception,localization,and cool down of the molten corium during a severe accident resulting from core melting.In this study,the role of a core catcher in the VVER-1000/v528 reactor containment during a station black out(SBO)accident is evaluated using the MELCOR1.8.6 code.In addition,parametric analyses of the SBO for(i)SBO accidents with emergency core cooling system(ECCS)operation,and(ii)without ECCS operation are performed.Furthermore,thermal–hydraulic analyses in dry and wet cavities with/without water are conducted.The investigations include the reduction of gases resulting from molten–corium–concrete interactions(H_(2),CO,CO_(2)).Core melting,gas production,and the pressure/temperature in the reactor containment are assessed.Additionally,a full investigation pertaining to gas release(H_(2),CO,CO_(2))and the pressure/temperature of the core catcher is performed.Based on MELCOR simulations,a core cavity and a perimeter water channel are the best options for corium cooling and a lower radionuclide release.This simulation is also theoretically investigated and discussed herein.The simulation results show that the core catcher system in addition to an internal sacrificial material reduces the containment pressure from 689 to 580 kPa and the corresponding temperature from 394 to 380 K.Furthermore,it is observed that the amount of gases produced,particularly hydrogen,decreased from 1698 to 1235 kg.Moreover,the presence of supporting systems,including an ECCS with a core catcher,prolonged the core melting time from 16,430 to 28,630 s(in an SBO accident)and significantly decreased the gases produced.
文摘Steam explosion is one of the crucial and poorly understood phenomena which may occur during severe accident scenario and may lead to containment failure. In spite of several experimental and analytical studies, the root cause of steam explosion has not been understood. Recent claims in the literature suggest that the presence of fine fragmentation during steam explosion causes its occurrence. In order to investigate this and understand the root cause of steam explosion, series of experiments were performed with 50 g to 2500 g of CaO-B<sub>2</sub>O<sub>3</sub>, a corium simulant in 4.5 litre of water. It was observed that steam explosion may occur even in the absence of fine fragments, which is contrary to the claims in the literature. To investigate further, conversion efficiency analysis was performed. This suggested that the amount of thermal energy converted to mechanical energy is more important deciding factor in explaining the occurrence of steam explosion. The present study discusses the importance of conversion efficiency in deciding steam explosion and also gives a new perspective to look at steam explosion phenomenology.