In order to clear constructional design of corner joint, it is necessary to further investi-gate mechanical property of corner joint in gabled frames. Through static test and finite element software analysis of compar...In order to clear constructional design of corner joint, it is necessary to further investi-gate mechanical property of corner joint in gabled frames. Through static test and finite element software analysis of comparing the panel zone with and without inclined stiffener. Some conclusions are given in the article. The load displacement curves show that the capacity of oblique nodes installed within stiffening rib components is enhanced i.e. 40% more than those without stiffening rib nodes. The results reveal that in the gabled frames, the corner node with the inclined stiffening rib can improve the bearing capacity of the specimens. When the extraterritorial flange is tension, the erection of the inclined stiffening rib can prevent structural failure and improve effectually the ductility of the structure.展开更多
The aim of our study is to reveal the effect of steel reinforcement details,tensile steel reinforcement ratio,compressed reinforcing steel ratio,reinforcing steel size,corner joint shape on the strength of reinforced ...The aim of our study is to reveal the effect of steel reinforcement details,tensile steel reinforcement ratio,compressed reinforcing steel ratio,reinforcing steel size,corner joint shape on the strength of reinforced concrete Fc'and delve into it for the most accurate details and concrete connections about the behavior and resistance of the corner joint of reinforced concrete,Depending on the available studies and sources in addition to our study,we concluded that each of these effects had a clear role in the behavior and resistance of the corner joint of reinforced concrete under the influence of the negative moment and yield stress.A study of the types of faults that can be reinforced angle joints obtains details and conditions of crushing that are almost identical for all types of steel reinforcement details and the basic requirements for the acceptable behavior of reinforced concrete joints in the installations and the efficiency of the joint and this may help us to prepare for disasters,whether natural or other,as happens with tremors The floor and failure that may occur due to wrong designs or old buildings and the possibility of using those connections to treat those joints and sections in reinforced or unarmed concrete facilities to preserve the safety of humans and buildings from sudden disasters and reduce and reduce risks,as well as qualitative control over the production of concrete connections and sections free from defects to the extreme.展开更多
文摘In order to clear constructional design of corner joint, it is necessary to further investi-gate mechanical property of corner joint in gabled frames. Through static test and finite element software analysis of comparing the panel zone with and without inclined stiffener. Some conclusions are given in the article. The load displacement curves show that the capacity of oblique nodes installed within stiffening rib components is enhanced i.e. 40% more than those without stiffening rib nodes. The results reveal that in the gabled frames, the corner node with the inclined stiffening rib can improve the bearing capacity of the specimens. When the extraterritorial flange is tension, the erection of the inclined stiffening rib can prevent structural failure and improve effectually the ductility of the structure.
文摘The aim of our study is to reveal the effect of steel reinforcement details,tensile steel reinforcement ratio,compressed reinforcing steel ratio,reinforcing steel size,corner joint shape on the strength of reinforced concrete Fc'and delve into it for the most accurate details and concrete connections about the behavior and resistance of the corner joint of reinforced concrete,Depending on the available studies and sources in addition to our study,we concluded that each of these effects had a clear role in the behavior and resistance of the corner joint of reinforced concrete under the influence of the negative moment and yield stress.A study of the types of faults that can be reinforced angle joints obtains details and conditions of crushing that are almost identical for all types of steel reinforcement details and the basic requirements for the acceptable behavior of reinforced concrete joints in the installations and the efficiency of the joint and this may help us to prepare for disasters,whether natural or other,as happens with tremors The floor and failure that may occur due to wrong designs or old buildings and the possibility of using those connections to treat those joints and sections in reinforced or unarmed concrete facilities to preserve the safety of humans and buildings from sudden disasters and reduce and reduce risks,as well as qualitative control over the production of concrete connections and sections free from defects to the extreme.