Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Base...Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.展开更多
Objective:Coronary artery anatomical variations and anomalies are an important topic due to their potential clinical manifestations.This study aims to investigate the prevalence of coronary artery anatomical variation...Objective:Coronary artery anatomical variations and anomalies are an important topic due to their potential clinical manifestations.This study aims to investigate the prevalence of coronary artery anatomical variations and anomalies in symptomatic patients with coronary computed tomography angiography(CCTA).Methods:This is a retrospective study that included all symptomatic patients who had CCTA in a tertiary care hospital in Saudi Arabia during a period of seven years.Results:The total number of included patients was 507(60%males)with a mean age of 57.4 years.Approximately 41%had luminal stenoses,averaging 49.7%.The total num-ber of patients with coronary anatomical variations(CAV)and coronary artery anomalies(CAA)was 217(43%).CAV prevalence was 26%,which included 14%non-right coronary dominance,5%short left main coronary artery(LMCA),and 7%division variations(trifurcation and quadrifurcarion)of the LMCA.The prevalence of CAA was 29%,which included 5%origin anomalies,22%myocardial bridge,and 2%course anomalies.Conclusions:A high prevalence of coronary artery anatomic variations and anomalies in symptomatic patients is reported in this study.Systematic reviews,meta-analyses,reporting guidelines,and unified definitions and classifications of cor-onary variations and anomalies are lacking in the literature,presenting potential opportunities for future research and publications.展开更多
BACKGROUND Portal vein gas(PVG)is an abnormal accumulation of gas within the portal and intrahepatic portal veins.It is associated with various abdominal diseases,ranging from benign conditions to life-threatening one...BACKGROUND Portal vein gas(PVG)is an abnormal accumulation of gas within the portal and intrahepatic portal veins.It is associated with various abdominal diseases,ranging from benign conditions to life-threatening ones that require immediate surgical intervention.Coronary angiography is the standard diagnostic procedure for coronary artery disease.There were no prior reports are available of PVG as a complication of coronary angiography.CASE SUMMARY In the specific case described here,the patient did not show signs of peritoneal irritation;however,computed tomography scans findings revealed pneumatosis in the wall of the small intestine,hepatic portal vein,and mesenteric vein,along with acute enteritis(etiology pending classification).A cesarean section was not performed,and the patient received treatment with fasting,rehydration,and antiinfection therapy.Subsequently,the patient's symptoms of abdominal distension and pain improved,and follow-up computed tomography scans indicated resolution of the portal system pneumatosis and intestinal wall edema,resulting in a favorable clinical outcome.CONCLUSION Portal venous gas complication following coronary angiography was a complication of coronary angiography.展开更多
Introduction: Cardiac catheterisation plays a fundamental role in the management of acute coronary syndrome. These explorations require heavy, complex and costly equipment and a large team of doctors, nurses and techn...Introduction: Cardiac catheterisation plays a fundamental role in the management of acute coronary syndrome. These explorations require heavy, complex and costly equipment and a large team of doctors, nurses and technicians with highly specialized training. Aims: To describe epidemiological, clinical and coronary angiography aspects of patients with acute coronary syndrome. Patients and Methods: Descriptive study from September 2019 to December 2023 in the Cardiology Department of the Hôpital Mère-Enfant of Bamako. Inclusion criteria were patients admitted for coronary angiography with the diagnosis of acute coronary syndrome. Results: During the study period, 1253 patients underwent coronary angiography, 596 of whom had acute coronary syndrome as an indication, representing a hospital frequency of 47%. Sex-ratio was 2.10. Mean age of patients was 58.5 ± 11.39 years. ST elevation acute coronary syndrome was the most common indication with 63.92% of cases. High blood pressure was the main cardiovascular risk factor with 58.7% of cases, and radial access approach was used in 98% of cases. Coronary angiography was pathological in 91.70% of cases (n = 548). Patients with lesions of anterior interventricular artery were 73.73% of cases. Tritruncal lesions accounted for 40.63% of cases. Conclusion: ST elevation acute coronary syndrome is the most frequent manifestation of acute coronary syndrome. Anterior interventricular artery is most often the culprit lesion for our patients.展开更多
Background: Diabetes mellitus (DM) is independently associated with an increased risk of cardiovascular mortality and morbidity, including coronary artery disease (CAD). CAD is a shared burden disease and the leading ...Background: Diabetes mellitus (DM) is independently associated with an increased risk of cardiovascular mortality and morbidity, including coronary artery disease (CAD). CAD is a shared burden disease and the leading cause of death in developed and developing countries. We aimed to assess the angiographic patterns of coronary arteries in patients with DM in a developing country (Yemen) as the first study. Methods: This study is a cross-sectional, prospective, observational study that includes a total of 250 patients who were admitted for elective diagnostic coronary angiography. Results: 96 (38.4%) patients were diabetics;68% were male;mean age was 57 ± 11 years. The incidence of three-vessel disease was 31.2% of patients. Considering the severity of lumen occlusion, (11.2%) of patients had non-significant lesions, (37.6%) of patients had significant lesions, and (32%) had total occlusive lesions. Lesions were of LAD in 76%, RCA in 60%, and LCX in 52% of the population. Among diabetics, two and 3-vessel diseases (33.3% vs. 20.8% & 50% vs. 19.5%, P = 0.001), left main lesion (10.4% vs. 2.6%, P = 0.012), significant stenosis (41.7% vs. 35.1%, P = 0.032), total occlusion of coronary arteries (43.8% vs. 19.5%, P = 0.032) and type C lesion (66.7% vs. 35.1%, P = 0.010) were more frequent than non-DM patients. Conclusion: The burden of significant and severe coronary lesions is more common among DM, which may be the major cause of morbidity and mortality of DM in developing countries.展开更多
Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary a...Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery.展开更多
BACKGROUND Coronary artery diseases can cause myocardial ischemia and hypoxia,angina pectoris,myocardial infarction,arrhythmia,and even sudden death led to inflight incapacitation of aircrew.As the main cause of groun...BACKGROUND Coronary artery diseases can cause myocardial ischemia and hypoxia,angina pectoris,myocardial infarction,arrhythmia,and even sudden death led to inflight incapacitation of aircrew.As the main cause of grounding due to illness,they severe threats to the health and fighting strength of military aircrew.Early warning in an early and accurate manner and early intervention of diseases possibly resulting in inflight incapacitation are key emphases of aeromedical support in clinic.AIM To figure out the flight factors and clinical characteristics of military aircrew with abnormal results of coronary artery computed tomographic angiography(CTA),thereby rendering theoretical references for clinical aeromedical support of military flying personnel.METHODS The clinical data of 15 flying personnel who received physical examinations in a military medical center from December 2020 to June 2023 and were diagnosed with coronary artery diseases by coronary artery CTA were collected and retrospectively analyzed,and a descriptive statistical analysis was conducted on their onset age,aircraft type and clinical data.RESULTS The 15 military flying personnel diagnosed with coronary artery diseases by coronary artery CTA were composed of 9 pilots,1 navigator and 5 air combat service workers.Multi-vessel disease was detected in 9 flying personnel,among which 8(88.9%)were pilots.Flying personnel with multi-vessel disease had higher content of cholesterol,low-density lipoprotein cholesterol and apolipoprotein B than those with single-vessel disease.CONCLUSION Coronary artery diseases are the major heart disease for the grounding of flying personnel due to illness,which can lead to inflight incapacitation.Coronary artery CTA is conducive to early detection and early intervention treatment of such diseases in clinic.展开更多
BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic im...BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic implications and longterm management strategies.Vascular and metabolic factors are being thought to play a role in such autoimmune neuro-inflammatory disorders,apart from the obvious immune mediated damage.With the advent of optical coherence tomography angiography(OCTA),it is easy to pick up on these subclinical macular microvascular and structural changes.AIM To study the macular microvascular and structural changes on OCTA in atypical optic neuritis.METHODS This observational cross-sectional study involved 8 NMOSD and 17 MOGAD patients,diagnosed serologically,as well as 10 healthy controls.Macular vascular density(MVD)and ganglion cell+inner plexiform layer thickness(GCIPL)were studied using OCTA.RESULTS There was a significant reduction in MVD in NMOSD and MOGAD affected as well as unaffected eyes when compared with healthy controls.NMOSD and MOGAD affected eyes had significant GCIPL thinning compared with healthy controls.NMOSD unaffected eyes did not show significant GCIPL thinning compared to healthy controls in contrast to MOGAD unaffected eyes.On comparing NMOSD with MOGAD,there was no significant difference in terms of MVD or GCIPL in the affected or unaffected eyes.CONCLUSION Although significant microvascular and structural changes are present on OCTA between atypical optic neuritis and normal patients,they could not help in differentiating between NMOSD and MOGAD cases.展开更多
Objective:To assess the feasibility of coronary angiography by transradial approach with 4F catheter.Methods:The procedural details,picture quality,local complication were recorded for coronary by transradial approach...Objective:To assess the feasibility of coronary angiography by transradial approach with 4F catheter.Methods:The procedural details,picture quality,local complication were recorded for coronary by transradial approach with 4F catheter in 138 patients.Results:The success rate of angiography was 97.7%;fluoroscopy time was(5.05±3.23)minutes,total procedural time was(20.51±3.37)minutes;the incidence of dislodgement,excessive engagement of either coronary artery was 7.8%,9.4%,repectively;the angiographic scores for left anterior descending,circumflex and right coronary arteries were(2.87±0.40),(2.88±0.39),(2.90±0.35),respectively.The spasm complication occurred 4.3% in radial artery and 1.5% in coronary artery.There were no occlusion of radial artery during follow up.Conclusion:4F catheter could be the first chosen in some selecting patients for its nice maneuverability,fine images and fewer vascular complications.展开更多
Objective To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral fliPS) mode for coronary stents patency. Methods We conducted a prospective study on 120 patients with 260 ...Objective To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral fliPS) mode for coronary stents patency. Methods We conducted a prospective study on 120 patients with 260 previous stents implanted due to recurred suspicious symptoms of angina scheduled for invasive coronary angiography (ICA), while DSCT were conducted using HPS mode. Results There was no significant impact of age, body mass index or heat rate (HR) on image quality (P 〉 0.05), while HR variability had a slight impact on that (P 〈 0.05). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of DSCT in detection of in-stent restenosis (ISR) based per-patient were 92.3%, 96.7%, 88.9%, and 97.8%, respectively. And those based per-stent were 87%, 96.8%, 83.3%, and 97.7% with un-assessment stents, 97.4%, 99.5%, 97.4%, and 99.5% without un-assessment stents. There was significant differ- ence on sensitivity, specificity, PPV and NPV between diameter 〉 3.0 mm group (93.3%, 97.9%, 87.5%, and 98.9%) and diameter 〈 3.0 mm group (80%, 93.3%, 80.0%, and 93.3%) (P 〈 0.05), and that between stent number 〉 3 group (82.3%, 77.8%, 66.7%, and 60%) with 〈 3 group (97.3%, 80%, 96.5%, and 75%). The effective dose of DSCT (1.4 ± 0.5 mSv) is significantly less than that by invasive coronary angiography [4.0 ± 0.8 mSv (P 〈 0.01)]. Conclusion DSCT using HPS mode provides good diagnostic performance on stent patency with lower effective dose in patients with HR 〈 65 beats/rain.展开更多
The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 a...The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 and heart rate(HR)<70 beats/min were randomly divided into four groups:group A(n=31,80 kVp,270 mgl/mL);group B(n=33,100 kVp,270 mgl/mL);group C(h=30,100 kVp,320 mgl/mL);group D(w=27,100 kVp,400 mgl/mL).The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group.The CT values and SD values of the aortic root(AR),subcutaneous fat,left coronary artery opening(LCA),and right coronary artery opening(RCA)were measured in all groups,the signalto-noise ratio(SNR)and contrast noise ratio(CNR)were calculated,and effective radiation dose and iodine intake were recorded.The subjective assessment for image quality was performed by two physicians using a 4-point scale.The results were compared using the one-way ANOVA and rank sum tests.The image quality of the four groups met the clinical diagnostic requirements.The CT values of AR in groups A,B,C,and D were 537.6±71.4,447.2±81.9,445.2±64.9 and 518.5±94.9 Hu,respectively,with no significant difference between group A and group D,or between group B and group C,while CT values in groups B and C were significantly lower than those in groups A and D(P<0.05).In groups A,B,C,and D,the LCA SNR values were 22.7±9.1,23.3±9.1,23.3±7.7 and 26.6±8.9,and the RCA CNR values were 26.9±9.&28.5±11.4,27.7土&8 and 32」±10.6,respectively.The AR visual scores in groups A,B,C and D were 3.8±0.2,3.9±0.3,3.9±0.3 and 4.0±0.3,respectively.There were no significant differences in SNR,CNR and visual score among the four groups(P>0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction.展开更多
Background The computational fluid dynamics(CFD)approach has been frequently applied to compute the fractional flow reserve(FFR)using computed tomography angiography(CTA).This technique is efficient.We developed the D...Background The computational fluid dynamics(CFD)approach has been frequently applied to compute the fractional flow reserve(FFR)using computed tomography angiography(CTA).This technique is efficient.We developed the DEEPVESSEL-FFR platform using the emerging deep learning technique to calculate the FFR value out of CTA images in five minutes.This study is to evaluate the DEEPVESSEL-FFR platform using the emerging deep learning technique to calculate the FFR value from CTA images as an efficient method.Methods A single-center,prospective study was conducted and 63 patients were enrolled for the evaluation of the diagnostic performance of DEEPVESSEL-FFR.Automatic quantification method for the three-dimensional coronary arterial geometry and the deep learning based prediction of FFR were developed to assess the ischemic risk of the stenotic coronary arteries.Diagnostic performance of the DEEPVESSEL-FFR was assessed by using wire-based FFR as reference standard.The primary evaluation factor was defined by using the area under receiver-operation characteristics curve(AUC)analysis.Results For per-patient level,taking the cut-off value<0.8 referring to the FFR measurement,DEEPVESSEL-FFR presented higher diagnostic performance in determining ischemia-related lesions with area under the curve of 0.928 compare to CTA stenotic severity 0.664.DEEPVESSEL-FFR correlated with FFR(R=0.686,P<0.001),with a mean di&ference of-0.006士0.0091(P=0.619).The secondary evaluation factors,indicating per vessel accuracy,sensitivity,specificity,positive predictive value,and negative predictive value were 87.3%,97.14%,75%,82.93%,and 95.45%,respectively.Conclusion DEEPVESSEL-FFR is a novel method that allows efficient assessment of the functional significance of coronary stenosis.展开更多
Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona...Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.展开更多
Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiogr...Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.展开更多
Radiocontrast-induced nephropathy(RCIN) is an acute and severe complication after coronary angiography,particularly for patients with pre-existing chronic kidney disease(CKD).It has been associated with both short-and...Radiocontrast-induced nephropathy(RCIN) is an acute and severe complication after coronary angiography,particularly for patients with pre-existing chronic kidney disease(CKD).It has been associated with both short-and long-term adverse outcomes,including the need for renal replacement therapy,increased length of hospital stay,major cardiac adverse events,and mortality.RCIN is generally defined as an increase in serum creatinine concentration of 0.5 mg/dL or 25%above baseline within 48 h after contrast administration.There is no effective therapy once injury has occurred,therefore,prevention is the cornerstone for all patients at risk for acute kidney injury(AKI).There is a small but growing body of evidence that prevention of AKI is associated with a reduction in later adverse outcomes.The optimal strategy for preventing RCIN has not yet been established.This review discusses the principal risk factors for RCIN,evaluates and summarizes the evidence for RCIN prophylaxis,and proposes recommendations for preventing RCIN in CKD patients undergoing coronary angiography.展开更多
AIM To investigate the impact of coronary artery disease in a cohort of patients resuscitated from cardiac arrest with non-diagnostic electrocardiogram.METHODS From March 2004 to February 2016, 203 consecutive patient...AIM To investigate the impact of coronary artery disease in a cohort of patients resuscitated from cardiac arrest with non-diagnostic electrocardiogram.METHODS From March 2004 to February 2016, 203 consecutive patients resuscitated from in or out-of-hospital sudden cardiac arrest and non-diagnostic post-resuscitation electrocardiogram(defined as ST segment elevation or pre-sumably new left bundle branch block) whounderwent invasive coronary angiogram during hospitalization were included. For purpose of analysis and comparison, patients were classified in two groups: Initial shockable rhythm(ventricular tachycardia or ventricular fibrillation; n = 148, 72.9%) and initial non-shockable rhythm(n = 55, 27.1%). Baseline characteristics, coronary angiogram findings including Syntax Score and long-term survival rates were compared. RESULTS Sudden cardiac arrest was witnessed in 95.2% of cases, 66.7% were out-of-hospital patients and 72.4% were male. There were no significant differences in baseline characteristics between groups except for higher mean age(68.1 years vs 61 years, P = 0.001) in the nonshockable rhythm group. Overall 5-year mortality of the resuscitated patients was 37.4%. Patients with non-shockable rhythms had higher mortality(60% vs 29.1%, P < 0.001) and a worst neurological status at hospital discharge based on cerebral performance category score(CPC 1-2: 32.7% vs 53.4%, P = 0.02). Although there were no significant differences in global burden of coronary artery disease defined by Syntax Score(mean Syntax Score: 10.2 vs 10.3, P = 0.96) there was a trend towards a higher incidence of acute coronary lesions in patients with shockable rhythm(29.7% vs 16.4%, P = 0.054). There was also a higher need for ad-hoc percutaneous coronary intervention in this group(21.9% vs 9.1%, P = 0.03). CONCLUSION Initial shockable group of patients had a trend towards higher incidence of acute coronary lesions and higher need of ad-hoc percutaneous intervention vs nonshockable group.展开更多
AIM: To assess the attenuation of non-calcified atherosclerotic coronary artery plaques with computed tomography coronary angiography (CTCA). METHODS: Four hundred consecutive patients underwent CTCA (Group 1: 200 pat...AIM: To assess the attenuation of non-calcified atherosclerotic coronary artery plaques with computed tomography coronary angiography (CTCA). METHODS: Four hundred consecutive patients underwent CTCA (Group 1: 200 patients, Sensation 64 Cardiac, Siemens; Group 2: 200 patients, VCT GE Healthcare, with either Iomeprol 400 or Iodixanol 320, respectively) for suspected coronary artery disease (CAD). CTCA was performed using standard protocols. Image quality (score 0-3), plaque (within the accessible non-calcified component of each non-calcified/mixed plaque) and coronary lumen attenuation were measured. Data were compared on a per-segment/per-plaque basis. Plaques were classified as fibrous vs lipid rich based on different attenuation thresholds. A P < 0.05 was considered significant. RESULTS: In 468 atherosclerotic plaques in Group 1 and 644 in Group 2, average image quality was 2.96 ± 0.19 in Group 1 and 2.93 ± 0.25 in Group 2 (P ≥ 0.05). Coronary lumen attenuation was 367 ± 85 Hounsfield units (HU) in Group 1 and 327 ± 73 HU in Group 2 (P < 0.05); non-calcified plaque attenuation was 48 ± 23 HU in Group 1 and 39 ± 21 HU in Group 2 (P < 0.05). Overall signal to noise ratio was 15.6 ± 4.7 in Group 1 and 21.2 ± 7.7 in Group 2 (P < 0.01). CONCLUSION: Higher intra-vascular attenuation modifies significantly the attenuation of non-calcified coronary plaques. This results in a more difficult characterization between lipid rich vs fibrous type.展开更多
Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acqu...Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.展开更多
Coronary computed tomography(CT)angiography has been recognized as the most rapidly developed imaging technique in the diagnosis of coronary artery disease due to the emergence and technological advances in multislice...Coronary computed tomography(CT)angiography has been recognized as the most rapidly developed imaging technique in the diagnosis of coronary artery disease due to the emergence and technological advances in multislice CT scanners.Coronary CT angiography has been confirmed to demonstrate high diagnostic and predictive value in coronary artery disease when compared to invasive coronary angiography.However,it suffers from high radiation dose which raises concerns in the medical field.Various dose-reduction strategies have been proposed with effective outcomes having been achieved to reduce radiation exposure to patients.This article provides an introduction and overview of the series of articles that will focus on each particular topic related to coronary CT angiography.展开更多
Coronary computed tomography(CT)angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compare...Coronary computed tomography(CT)angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography.Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320-slice CT scanners.Despite the promising diagnostic value,coronary CT angiography is still limited in some areas,such as inferior temporal resolution,motion-related artifacts and high false positive results due to severe calcification.The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners.Prognostic value of coronary CT angiography in coronary artery disease is also discussed,while limitations and challenges of coronary CT angiography are highlighted.展开更多
文摘Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.
文摘Objective:Coronary artery anatomical variations and anomalies are an important topic due to their potential clinical manifestations.This study aims to investigate the prevalence of coronary artery anatomical variations and anomalies in symptomatic patients with coronary computed tomography angiography(CCTA).Methods:This is a retrospective study that included all symptomatic patients who had CCTA in a tertiary care hospital in Saudi Arabia during a period of seven years.Results:The total number of included patients was 507(60%males)with a mean age of 57.4 years.Approximately 41%had luminal stenoses,averaging 49.7%.The total num-ber of patients with coronary anatomical variations(CAV)and coronary artery anomalies(CAA)was 217(43%).CAV prevalence was 26%,which included 14%non-right coronary dominance,5%short left main coronary artery(LMCA),and 7%division variations(trifurcation and quadrifurcarion)of the LMCA.The prevalence of CAA was 29%,which included 5%origin anomalies,22%myocardial bridge,and 2%course anomalies.Conclusions:A high prevalence of coronary artery anatomic variations and anomalies in symptomatic patients is reported in this study.Systematic reviews,meta-analyses,reporting guidelines,and unified definitions and classifications of cor-onary variations and anomalies are lacking in the literature,presenting potential opportunities for future research and publications.
文摘BACKGROUND Portal vein gas(PVG)is an abnormal accumulation of gas within the portal and intrahepatic portal veins.It is associated with various abdominal diseases,ranging from benign conditions to life-threatening ones that require immediate surgical intervention.Coronary angiography is the standard diagnostic procedure for coronary artery disease.There were no prior reports are available of PVG as a complication of coronary angiography.CASE SUMMARY In the specific case described here,the patient did not show signs of peritoneal irritation;however,computed tomography scans findings revealed pneumatosis in the wall of the small intestine,hepatic portal vein,and mesenteric vein,along with acute enteritis(etiology pending classification).A cesarean section was not performed,and the patient received treatment with fasting,rehydration,and antiinfection therapy.Subsequently,the patient's symptoms of abdominal distension and pain improved,and follow-up computed tomography scans indicated resolution of the portal system pneumatosis and intestinal wall edema,resulting in a favorable clinical outcome.CONCLUSION Portal venous gas complication following coronary angiography was a complication of coronary angiography.
文摘Introduction: Cardiac catheterisation plays a fundamental role in the management of acute coronary syndrome. These explorations require heavy, complex and costly equipment and a large team of doctors, nurses and technicians with highly specialized training. Aims: To describe epidemiological, clinical and coronary angiography aspects of patients with acute coronary syndrome. Patients and Methods: Descriptive study from September 2019 to December 2023 in the Cardiology Department of the Hôpital Mère-Enfant of Bamako. Inclusion criteria were patients admitted for coronary angiography with the diagnosis of acute coronary syndrome. Results: During the study period, 1253 patients underwent coronary angiography, 596 of whom had acute coronary syndrome as an indication, representing a hospital frequency of 47%. Sex-ratio was 2.10. Mean age of patients was 58.5 ± 11.39 years. ST elevation acute coronary syndrome was the most common indication with 63.92% of cases. High blood pressure was the main cardiovascular risk factor with 58.7% of cases, and radial access approach was used in 98% of cases. Coronary angiography was pathological in 91.70% of cases (n = 548). Patients with lesions of anterior interventricular artery were 73.73% of cases. Tritruncal lesions accounted for 40.63% of cases. Conclusion: ST elevation acute coronary syndrome is the most frequent manifestation of acute coronary syndrome. Anterior interventricular artery is most often the culprit lesion for our patients.
文摘Background: Diabetes mellitus (DM) is independently associated with an increased risk of cardiovascular mortality and morbidity, including coronary artery disease (CAD). CAD is a shared burden disease and the leading cause of death in developed and developing countries. We aimed to assess the angiographic patterns of coronary arteries in patients with DM in a developing country (Yemen) as the first study. Methods: This study is a cross-sectional, prospective, observational study that includes a total of 250 patients who were admitted for elective diagnostic coronary angiography. Results: 96 (38.4%) patients were diabetics;68% were male;mean age was 57 ± 11 years. The incidence of three-vessel disease was 31.2% of patients. Considering the severity of lumen occlusion, (11.2%) of patients had non-significant lesions, (37.6%) of patients had significant lesions, and (32%) had total occlusive lesions. Lesions were of LAD in 76%, RCA in 60%, and LCX in 52% of the population. Among diabetics, two and 3-vessel diseases (33.3% vs. 20.8% & 50% vs. 19.5%, P = 0.001), left main lesion (10.4% vs. 2.6%, P = 0.012), significant stenosis (41.7% vs. 35.1%, P = 0.032), total occlusion of coronary arteries (43.8% vs. 19.5%, P = 0.032) and type C lesion (66.7% vs. 35.1%, P = 0.010) were more frequent than non-DM patients. Conclusion: The burden of significant and severe coronary lesions is more common among DM, which may be the major cause of morbidity and mortality of DM in developing countries.
文摘Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery.
基金Supported by Enhancement Foundation Program of Naval Medical Center of Naval Medical University.
文摘BACKGROUND Coronary artery diseases can cause myocardial ischemia and hypoxia,angina pectoris,myocardial infarction,arrhythmia,and even sudden death led to inflight incapacitation of aircrew.As the main cause of grounding due to illness,they severe threats to the health and fighting strength of military aircrew.Early warning in an early and accurate manner and early intervention of diseases possibly resulting in inflight incapacitation are key emphases of aeromedical support in clinic.AIM To figure out the flight factors and clinical characteristics of military aircrew with abnormal results of coronary artery computed tomographic angiography(CTA),thereby rendering theoretical references for clinical aeromedical support of military flying personnel.METHODS The clinical data of 15 flying personnel who received physical examinations in a military medical center from December 2020 to June 2023 and were diagnosed with coronary artery diseases by coronary artery CTA were collected and retrospectively analyzed,and a descriptive statistical analysis was conducted on their onset age,aircraft type and clinical data.RESULTS The 15 military flying personnel diagnosed with coronary artery diseases by coronary artery CTA were composed of 9 pilots,1 navigator and 5 air combat service workers.Multi-vessel disease was detected in 9 flying personnel,among which 8(88.9%)were pilots.Flying personnel with multi-vessel disease had higher content of cholesterol,low-density lipoprotein cholesterol and apolipoprotein B than those with single-vessel disease.CONCLUSION Coronary artery diseases are the major heart disease for the grounding of flying personnel due to illness,which can lead to inflight incapacitation.Coronary artery CTA is conducive to early detection and early intervention treatment of such diseases in clinic.
文摘BACKGROUND Atypical optic neuritis,consisting of neuromyelitis optica spectrum disorders(NMOSD)or myelin oligodendrocyte glycoprotein antibody disease(MOGAD),has a very similar presentation but different prognostic implications and longterm management strategies.Vascular and metabolic factors are being thought to play a role in such autoimmune neuro-inflammatory disorders,apart from the obvious immune mediated damage.With the advent of optical coherence tomography angiography(OCTA),it is easy to pick up on these subclinical macular microvascular and structural changes.AIM To study the macular microvascular and structural changes on OCTA in atypical optic neuritis.METHODS This observational cross-sectional study involved 8 NMOSD and 17 MOGAD patients,diagnosed serologically,as well as 10 healthy controls.Macular vascular density(MVD)and ganglion cell+inner plexiform layer thickness(GCIPL)were studied using OCTA.RESULTS There was a significant reduction in MVD in NMOSD and MOGAD affected as well as unaffected eyes when compared with healthy controls.NMOSD and MOGAD affected eyes had significant GCIPL thinning compared with healthy controls.NMOSD unaffected eyes did not show significant GCIPL thinning compared to healthy controls in contrast to MOGAD unaffected eyes.On comparing NMOSD with MOGAD,there was no significant difference in terms of MVD or GCIPL in the affected or unaffected eyes.CONCLUSION Although significant microvascular and structural changes are present on OCTA between atypical optic neuritis and normal patients,they could not help in differentiating between NMOSD and MOGAD cases.
文摘Objective:To assess the feasibility of coronary angiography by transradial approach with 4F catheter.Methods:The procedural details,picture quality,local complication were recorded for coronary by transradial approach with 4F catheter in 138 patients.Results:The success rate of angiography was 97.7%;fluoroscopy time was(5.05±3.23)minutes,total procedural time was(20.51±3.37)minutes;the incidence of dislodgement,excessive engagement of either coronary artery was 7.8%,9.4%,repectively;the angiographic scores for left anterior descending,circumflex and right coronary arteries were(2.87±0.40),(2.88±0.39),(2.90±0.35),respectively.The spasm complication occurred 4.3% in radial artery and 1.5% in coronary artery.There were no occlusion of radial artery during follow up.Conclusion:4F catheter could be the first chosen in some selecting patients for its nice maneuverability,fine images and fewer vascular complications.
文摘Objective To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral fliPS) mode for coronary stents patency. Methods We conducted a prospective study on 120 patients with 260 previous stents implanted due to recurred suspicious symptoms of angina scheduled for invasive coronary angiography (ICA), while DSCT were conducted using HPS mode. Results There was no significant impact of age, body mass index or heat rate (HR) on image quality (P 〉 0.05), while HR variability had a slight impact on that (P 〈 0.05). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of DSCT in detection of in-stent restenosis (ISR) based per-patient were 92.3%, 96.7%, 88.9%, and 97.8%, respectively. And those based per-stent were 87%, 96.8%, 83.3%, and 97.7% with un-assessment stents, 97.4%, 99.5%, 97.4%, and 99.5% without un-assessment stents. There was significant differ- ence on sensitivity, specificity, PPV and NPV between diameter 〉 3.0 mm group (93.3%, 97.9%, 87.5%, and 98.9%) and diameter 〈 3.0 mm group (80%, 93.3%, 80.0%, and 93.3%) (P 〈 0.05), and that between stent number 〉 3 group (82.3%, 77.8%, 66.7%, and 60%) with 〈 3 group (97.3%, 80%, 96.5%, and 75%). The effective dose of DSCT (1.4 ± 0.5 mSv) is significantly less than that by invasive coronary angiography [4.0 ± 0.8 mSv (P 〈 0.01)]. Conclusion DSCT using HPS mode provides good diagnostic performance on stent patency with lower effective dose in patients with HR 〈 65 beats/rain.
文摘The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 and heart rate(HR)<70 beats/min were randomly divided into four groups:group A(n=31,80 kVp,270 mgl/mL);group B(n=33,100 kVp,270 mgl/mL);group C(h=30,100 kVp,320 mgl/mL);group D(w=27,100 kVp,400 mgl/mL).The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group.The CT values and SD values of the aortic root(AR),subcutaneous fat,left coronary artery opening(LCA),and right coronary artery opening(RCA)were measured in all groups,the signalto-noise ratio(SNR)and contrast noise ratio(CNR)were calculated,and effective radiation dose and iodine intake were recorded.The subjective assessment for image quality was performed by two physicians using a 4-point scale.The results were compared using the one-way ANOVA and rank sum tests.The image quality of the four groups met the clinical diagnostic requirements.The CT values of AR in groups A,B,C,and D were 537.6±71.4,447.2±81.9,445.2±64.9 and 518.5±94.9 Hu,respectively,with no significant difference between group A and group D,or between group B and group C,while CT values in groups B and C were significantly lower than those in groups A and D(P<0.05).In groups A,B,C,and D,the LCA SNR values were 22.7±9.1,23.3±9.1,23.3±7.7 and 26.6±8.9,and the RCA CNR values were 26.9±9.&28.5±11.4,27.7土&8 and 32」±10.6,respectively.The AR visual scores in groups A,B,C and D were 3.8±0.2,3.9±0.3,3.9±0.3 and 4.0±0.3,respectively.There were no significant differences in SNR,CNR and visual score among the four groups(P>0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction.
文摘Background The computational fluid dynamics(CFD)approach has been frequently applied to compute the fractional flow reserve(FFR)using computed tomography angiography(CTA).This technique is efficient.We developed the DEEPVESSEL-FFR platform using the emerging deep learning technique to calculate the FFR value out of CTA images in five minutes.This study is to evaluate the DEEPVESSEL-FFR platform using the emerging deep learning technique to calculate the FFR value from CTA images as an efficient method.Methods A single-center,prospective study was conducted and 63 patients were enrolled for the evaluation of the diagnostic performance of DEEPVESSEL-FFR.Automatic quantification method for the three-dimensional coronary arterial geometry and the deep learning based prediction of FFR were developed to assess the ischemic risk of the stenotic coronary arteries.Diagnostic performance of the DEEPVESSEL-FFR was assessed by using wire-based FFR as reference standard.The primary evaluation factor was defined by using the area under receiver-operation characteristics curve(AUC)analysis.Results For per-patient level,taking the cut-off value<0.8 referring to the FFR measurement,DEEPVESSEL-FFR presented higher diagnostic performance in determining ischemia-related lesions with area under the curve of 0.928 compare to CTA stenotic severity 0.664.DEEPVESSEL-FFR correlated with FFR(R=0.686,P<0.001),with a mean di&ference of-0.006士0.0091(P=0.619).The secondary evaluation factors,indicating per vessel accuracy,sensitivity,specificity,positive predictive value,and negative predictive value were 87.3%,97.14%,75%,82.93%,and 95.45%,respectively.Conclusion DEEPVESSEL-FFR is a novel method that allows efficient assessment of the functional significance of coronary stenosis.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.
文摘Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.
基金Supported by The Kaohsiung Veterans General Hospital,Grant No. VGHKS100-032 (in part)
文摘Radiocontrast-induced nephropathy(RCIN) is an acute and severe complication after coronary angiography,particularly for patients with pre-existing chronic kidney disease(CKD).It has been associated with both short-and long-term adverse outcomes,including the need for renal replacement therapy,increased length of hospital stay,major cardiac adverse events,and mortality.RCIN is generally defined as an increase in serum creatinine concentration of 0.5 mg/dL or 25%above baseline within 48 h after contrast administration.There is no effective therapy once injury has occurred,therefore,prevention is the cornerstone for all patients at risk for acute kidney injury(AKI).There is a small but growing body of evidence that prevention of AKI is associated with a reduction in later adverse outcomes.The optimal strategy for preventing RCIN has not yet been established.This review discusses the principal risk factors for RCIN,evaluates and summarizes the evidence for RCIN prophylaxis,and proposes recommendations for preventing RCIN in CKD patients undergoing coronary angiography.
文摘AIM To investigate the impact of coronary artery disease in a cohort of patients resuscitated from cardiac arrest with non-diagnostic electrocardiogram.METHODS From March 2004 to February 2016, 203 consecutive patients resuscitated from in or out-of-hospital sudden cardiac arrest and non-diagnostic post-resuscitation electrocardiogram(defined as ST segment elevation or pre-sumably new left bundle branch block) whounderwent invasive coronary angiogram during hospitalization were included. For purpose of analysis and comparison, patients were classified in two groups: Initial shockable rhythm(ventricular tachycardia or ventricular fibrillation; n = 148, 72.9%) and initial non-shockable rhythm(n = 55, 27.1%). Baseline characteristics, coronary angiogram findings including Syntax Score and long-term survival rates were compared. RESULTS Sudden cardiac arrest was witnessed in 95.2% of cases, 66.7% were out-of-hospital patients and 72.4% were male. There were no significant differences in baseline characteristics between groups except for higher mean age(68.1 years vs 61 years, P = 0.001) in the nonshockable rhythm group. Overall 5-year mortality of the resuscitated patients was 37.4%. Patients with non-shockable rhythms had higher mortality(60% vs 29.1%, P < 0.001) and a worst neurological status at hospital discharge based on cerebral performance category score(CPC 1-2: 32.7% vs 53.4%, P = 0.02). Although there were no significant differences in global burden of coronary artery disease defined by Syntax Score(mean Syntax Score: 10.2 vs 10.3, P = 0.96) there was a trend towards a higher incidence of acute coronary lesions in patients with shockable rhythm(29.7% vs 16.4%, P = 0.054). There was also a higher need for ad-hoc percutaneous coronary intervention in this group(21.9% vs 9.1%, P = 0.03). CONCLUSION Initial shockable group of patients had a trend towards higher incidence of acute coronary lesions and higher need of ad-hoc percutaneous intervention vs nonshockable group.
基金Supported by An unrestricted grant from GE Healthcare
文摘AIM: To assess the attenuation of non-calcified atherosclerotic coronary artery plaques with computed tomography coronary angiography (CTCA). METHODS: Four hundred consecutive patients underwent CTCA (Group 1: 200 patients, Sensation 64 Cardiac, Siemens; Group 2: 200 patients, VCT GE Healthcare, with either Iomeprol 400 or Iodixanol 320, respectively) for suspected coronary artery disease (CAD). CTCA was performed using standard protocols. Image quality (score 0-3), plaque (within the accessible non-calcified component of each non-calcified/mixed plaque) and coronary lumen attenuation were measured. Data were compared on a per-segment/per-plaque basis. Plaques were classified as fibrous vs lipid rich based on different attenuation thresholds. A P < 0.05 was considered significant. RESULTS: In 468 atherosclerotic plaques in Group 1 and 644 in Group 2, average image quality was 2.96 ± 0.19 in Group 1 and 2.93 ± 0.25 in Group 2 (P ≥ 0.05). Coronary lumen attenuation was 367 ± 85 Hounsfield units (HU) in Group 1 and 327 ± 73 HU in Group 2 (P < 0.05); non-calcified plaque attenuation was 48 ± 23 HU in Group 1 and 39 ± 21 HU in Group 2 (P < 0.05). Overall signal to noise ratio was 15.6 ± 4.7 in Group 1 and 21.2 ± 7.7 in Group 2 (P < 0.01). CONCLUSION: Higher intra-vascular attenuation modifies significantly the attenuation of non-calcified coronary plaques. This results in a more difficult characterization between lipid rich vs fibrous type.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.
文摘Coronary computed tomography(CT)angiography has been recognized as the most rapidly developed imaging technique in the diagnosis of coronary artery disease due to the emergence and technological advances in multislice CT scanners.Coronary CT angiography has been confirmed to demonstrate high diagnostic and predictive value in coronary artery disease when compared to invasive coronary angiography.However,it suffers from high radiation dose which raises concerns in the medical field.Various dose-reduction strategies have been proposed with effective outcomes having been achieved to reduce radiation exposure to patients.This article provides an introduction and overview of the series of articles that will focus on each particular topic related to coronary CT angiography.
文摘Coronary computed tomography(CT)angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography.Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320-slice CT scanners.Despite the promising diagnostic value,coronary CT angiography is still limited in some areas,such as inferior temporal resolution,motion-related artifacts and high false positive results due to severe calcification.The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners.Prognostic value of coronary CT angiography in coronary artery disease is also discussed,while limitations and challenges of coronary CT angiography are highlighted.