期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Chord length sampling correction analysis for dispersion fuel in Monte Carlo simulation
1
作者 Zhao-Yu Liang Ding She +1 位作者 Yu-Tong Wen Lei Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期57-64,共8页
Dispersion fuels,knowned for their excellent safety performance,are widely used in advanced reactors,such as hightemperature gas-cooled reactors.Compared with deterministic methods,the Monte Carlo method has more adva... Dispersion fuels,knowned for their excellent safety performance,are widely used in advanced reactors,such as hightemperature gas-cooled reactors.Compared with deterministic methods,the Monte Carlo method has more advantages in the geometric modeling of stochastic media.The explicit modeling method has high computational accuracy and high computational cost.The chord length sampling(CLS)method can improve computational efficiency by sampling the chord length during neutron transport using the matrix chord length?s probability density function.This study shows that the excluded-volume effect in realistic stochastic media can introduce certain deviations into the CLS.A chord length correction approach is proposed to obtain the chord length correction factor by developing the Particle code based on equivalent transmission probability.Through numerical analysis against reference solutions from explicit modeling in the RMC code,it was demonstrated that CLS with the proposed correction method provides good accuracy for addressing the excludedvolume effect in realistic infinite stochastic media. 展开更多
关键词 Stochastic media Monte Carlo Chord length sampling Excluded-volume effect Chord length correction
下载PDF
An optical sensor for hydrogen sulfide detection in open path using WMS-2f/1f technique 被引量:1
2
作者 宋丽梅 刘力文 +2 位作者 杨燕罡 郭庆华 习江涛 《Optoelectronics Letters》 EI 2016年第6期465-468,共4页
An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) la... An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) laser emitting at 1.578 μm and a homemade gas cell with 1-m-long optical path length. The novel sensor is constructed by an electrical cabinet and an optical reflecting and receiving end. The DFB laser is employed for targeting a strong H_2S line at 6 336.62 cm^(-1) in the fundamental absorption band of H_2S. The sensor performance, including the minimum detection limit and the stability, can be improved by reducing the laser intensity drift and common mode noise by means of the WMS-2f/1f technique. The experimental results indicate that the linearity and response time of the sensor are 0.999 26 and 6 s(in concentration range of 15.2—45.6 mg/m^3), respectively. The maximum relative deviation for continuous detection(60 min) of 30.4 mg/m^3 H_2S is 0.48% and the minimum detection limit obtained by Allan variance is 79 μg/m^3 with optimal integration time of 32 s. The optical H_2S sensor can be applied to environmental monitoring and industrial production, and it has significance for real-time online detection in many fields. 展开更多
关键词 corrected sulfide deviation Allan reflecting harmonic targeting drift linearity length
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部