This study was performed in order to determine visitation at remote areas that would be unaffordable due to logistic reasons. Four TrafxTM vehicle counters, each programmed with different settings, were placed along t...This study was performed in order to determine visitation at remote areas that would be unaffordable due to logistic reasons. Four TrafxTM vehicle counters, each programmed with different settings, were placed along the lone access road to remotely sense the daily use activities and count accuracy at the New Underwood Lake Public Water Access Area. Use was corroborated during daylight hours with game cameras. Data was stratified between weekdays/weekends due to differences between the two periods. Two counter settings, threshold and delay, were best when set at a value of 8, but a value of 16 for delay provided almost equal results. Overall, there were 38 counts of use per day for a total of 2318 over the 61 day period. This study demonstrated how vehicle counters, in combination with game cameras for verification, can aid managers for determining use in remote access areas. Future work may lead to identifying details for producing a surrogate to traditional angler use surveys.展开更多
AIM: To evaluate the accuracy of automated blood cell counters for ascitic polymorphonuclear (PMN) determination for: (1) diagnosis, (2) efficacy of the ongoing antibiotic therapy, and (3) resolution of spon...AIM: To evaluate the accuracy of automated blood cell counters for ascitic polymorphonuclear (PMN) determination for: (1) diagnosis, (2) efficacy of the ongoing antibiotic therapy, and (3) resolution of spontaneous bacterial peritonitis (SBP). METHODS: One hundred and twelve ascitic fluid samples were collected from 52 consecutive cirrhotic patients, 16 of them with SBP. The agreement between the manual and the automated method for PMN count was assessed. The sensitivity/specificity and the positive/negative predictive value of the automated blood cell counter were also calculated by considering the manual method as the "gold standard" RESULTS: The mean + SD of the difference between manual and automated measurements was 7.8 4- 58 cells/ram3, while the limits of agreement were +124 cells/mm3 [95% confidence interval (CI): +145 to +103] and -108 cells/mm3 (95% CI: -87 to -129). The automated cell counter had a sensitivity of 100% and a specificity of 97.7% in diagnosing SBP, and a sensitivity of 91% and a specificity of 100% for the efficacy of the ongoing antibiotic therapy. The two methods showed a complete agreement for the resolution of infection. CONCLUSION: Automated cell counters not only have a good diagnostic accuracy, but are also very effectivein monitoring the antibiotic treatment in patients with SBP. Because of their quicker performance, they should replace the manual counting for PMN determination in the ascitic fluid of patients with SBP.展开更多
In vivo measurement of radioactivity based on various body counters is arguably the leading measure used to determine the distribution and activity of radionuclides in human subjects,such as I-131 in the thyroid,Am-24...In vivo measurement of radioactivity based on various body counters is arguably the leading measure used to determine the distribution and activity of radionuclides in human subjects,such as I-131 in the thyroid,Am-241 in the lungs,and Pb-210 in the skull.Throughout the measurements,the radiation background is the key factor that determines the sensitivity of the counter.Therefore,to facilitate in vivo measurements,a well-designed shielding room is required to create a low-background environment.However,because the compositions of the radiation background are quite complicated,the respective contributions from each source remain obscure,which places a considerable burden on seeking an optimized design of shielding rooms that strikes the optimum balance between the construction cost and background suppression effect.In this study,we conducted a systematic experimental investigation on the radiation background outside and inside four representative body counters with assorted designs using a variety of radiation detectors,including high-purity germanium detectors,CdZnTe detector,radon emanometer,and gamma-ray dosimeter.By carefully controlling the experimental conditions and synergetic analysis of the measurement results,in conjunction with previous studies,we separated and determined the relative contributions induced by environmental radiation(4%),airborne radon and its daughters(2%),the normal radioactivity of human subjects arising from K-40(58%),cosmic rays(12%),and radioactivity in shielding materials and measuring instruments(24%).Furthermore,based on these results,we discuss practical guidelines to design a shielding room for body counters.展开更多
The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol partic...The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol particles. The study focused on how commercial instruments perform during routine measurements respect to OPC scientific understanding, because it is important for users of such instruments to be aware of their limitations. Measurements were performed using aerosol generated by a Monodisperse Aerosol Generator (MAGE), which produced carnauba wax particles of diameter (1.00 ± 0.08) μm and (1.40 ± 0.15) μm, and monodisperse Polystyrene Latex (PSL) aerosol with nominal diameter of 1.0mm. The results show comparable total particle number concentrations for all the counters, when the count of the first size channel (0.3 - 0.4 μm) for the 1.108 Grimm counter was left out. In the said channel the Grimm counter 1.108 always showed much higher particle counts than those inferred from the tested aerosols. The overcount was proved by the fact that the aerosol sampled in each test on a Nuclepore filter showed no particles in the 0.3 - 0.4 μm range when examined under Scanning Electronic Microscope (SEM). The presence of an artefact produced by the counter was assumed as a likely explanation. For all the counters, the Count Median Diameters (CMDs) of aerosol size distributions, were far below the expected value for the aerosol used. The nearest CMD values to the expected ones were shown by the Grimm 1.107 counter.展开更多
A simple method employing a pair of pancake-style Geiger-Mueller (GM) counters for quantitative measurement of radon activity concentration (activity per unit volume) is described and demonstrated. The use of two GM c...A simple method employing a pair of pancake-style Geiger-Mueller (GM) counters for quantitative measurement of radon activity concentration (activity per unit volume) is described and demonstrated. The use of two GM counters, together with the basic theory derived in this paper, permit the detection of alpha particles from decay of and progeny ( <sup>218</sup>Po, <sup>214</sup>Po) and the conversion of the alpha count rate into a radon concentration. A unique feature of this method, in comparison with standard methodologies to measure radon concentration, is the absence of a fixed control volume. Advantages afforded by the reported GM method include: 1) it provides a direct in-situ value of radon level, thereby eliminating the need to send samples to an external testing laboratory;2) it can be applied to monitoring radon levels exhibiting wide short-term variability;3) it can yield short-term measurements of comparable accuracy and equivalent or higher precision than a commercial radon monitor sampling by passive diffusion;4) it yields long-term measurements statistically equivalent to commercial radon monitors;5) it uses the most commonly employed, overall least expensive, and most easily operated type of nuclear instrumentation. As such, the method is par-ticularly suitable for use by researchers, public health personnel, and home dwellers who prefer to monitor indoor radon levels themselves. The results of a consecutive 30-day sequence of 24 hour mean radon measurements by the proposed GM method and a commercial state-of-the-art radon monitor certified for radon testing are compared.展开更多
Different fuzzy reasoning methods were gave by choosing different fuzzy counters.This article generally introduced the basic structure of fuzzy controller,and compared and analysised the reasoning effect of fuzzy reas...Different fuzzy reasoning methods were gave by choosing different fuzzy counters.This article generally introduced the basic structure of fuzzy controller,and compared and analysised the reasoning effect of fuzzy reasoning methods and the effect of computer simulating control basicly on different fuzzy counters.展开更多
Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate ...Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.展开更多
HANDS-ON LAB You can use positive and negative counters to model the addition of integers.The counter + represents 1,and the counter - represents-1.Remember that addition means combining two sets.ACTIVITY Work with a ...HANDS-ON LAB You can use positive and negative counters to model the addition of integers.The counter + represents 1,and the counter - represents-1.Remember that addition means combining two sets.ACTIVITY Work with a partner.展开更多
The optical particle counter (OPC) is widely used in the measurement of aerosol. The calculation results of response curves for several commercial counters indicate that these curves are quite sensitive to the refract...The optical particle counter (OPC) is widely used in the measurement of aerosol. The calculation results of response curves for several commercial counters indicate that these curves are quite sensitive to the refractive index, especially to its imaginary part. If the particle sizes were determined with the cali-展开更多
Workload characterization is critical for resource management and scheduling.Recently,with the fast development of container technique,more and more cloud service providers like Google and Alibaba adopt containers to ...Workload characterization is critical for resource management and scheduling.Recently,with the fast development of container technique,more and more cloud service providers like Google and Alibaba adopt containers to provide cloud services,due to the low overheads.However,the characteristics of co-located diverse services(e.g.,interactive on-line services,off-line computing services)running in containers are still not clear.In this paper,we present a comprehensive analysis of the characteristics of co-located workloads running in containers on the same server from the perspective of hardware events.Our study quantifies and reveals the system behavior from the micro-architecture level when workloads are running in different co-location patterns.Through the analysis of typical hardware events,we provide recommended/unrecommended co-location workload patterns which provide valuable deployment suggestions for datacenter administrators.展开更多
To enhance the accuracy of 2πα and 2πβ particle surface emission rate measurements and address the identification issues of nuclides in conventional methods, this study introduces two artificial neural network(ANN...To enhance the accuracy of 2πα and 2πβ particle surface emission rate measurements and address the identification issues of nuclides in conventional methods, this study introduces two artificial neural network(ANN) algorithms: back-propagation(BP) and genetic algorithm-based back-propagation(GA-BP). These algorithms classify pulse signals from distinct α and β particles. Their discrimination efficacy is assessed by simulating standard pulse signals and those produced by contaminated sources, mixing α and β particles within the detector. This study initially showcases energy spectrum measurement outcomes, subsequently tests the ANNs on the measurement and validation datasets, and contrasts the pulse shape discrimination efficacy of both algorithms. Experimental findings reveal that the proportional counter's energy resolution is not ideal, thus rendering energy analysis insufficient for distinguishing between 2πα and 2πβ particles. The BP neural network realizes approximately 99% accuracy for 2πα particles and approximately 95% for 2πβ particles, thus surpassing the GA-BP's performance. Additionally, the results suggest enhancing β particle discrimination accuracy by increasing the digital acquisition card's threshold lower limit. This study offers an advanced solution for the 2πα and 2πβ surface emission rate measurement method, presenting superior adaptability and scalability over conventional techniques.展开更多
Introduction: Maternal death or maternal mortality is “the death of a woman occurring during pregnancy or within 42 days of termination, regardless of duration or location, for any specific cause or aggravated b...Introduction: Maternal death or maternal mortality is “the death of a woman occurring during pregnancy or within 42 days of termination, regardless of duration or location, for any specific cause or aggravated by pregnancy or its management, but neither accidental nor fortuitous. Methods: This was a descriptive and analytical cross-sectional study carried out from January 1<sup>st</sup>, 2021 to April 30<sup>th</sup>, 2022 at the Obstetrics Gynecology Clinic of the Sylvanus Olympio University Hospital Center (SOUHC). Results: we noted 86 cases of maternal deaths after referral/evacuation i.e. a maternal mortality rate hospital of 555 maternal deaths per 100,000 LB. The average age of the patients was 31.1 ± 6.3 years with extremes of 15 and 45 years. In 33.7% of cases our patients were resellers. Multiparas represented 33.7% of the sample, they had performed less than three antenatal consultations. Postpartum hemorrhage was the reference reason in 33.7%. In 74.4% of cases, the patients referred had arrived by taxi. In 87.9% of cases, the patients had died of direct obstetric causes. Immediate postpartum hemorrhage accounted for 44.6% of cases and anemia, 36.4%. There is a statistically significant association between the availability of blood product and the avoidability of maternal death after obstetrical referral and/or evacuation (p value = 0.0188 0.05). Conclusion: Determining responsibility for maternal death is not always easy. There is an urgent need to strengthen the policy of reducing maternal mortality in Togo. This remains possible by developing communication strategies and a solid referral/counter-referral system.展开更多
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ...In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.展开更多
Maximum frequent pattern generation from a large database of transactions and items for association rule mining is an important research topic in data mining. Association rule mining aims to discover interesting corre...Maximum frequent pattern generation from a large database of transactions and items for association rule mining is an important research topic in data mining. Association rule mining aims to discover interesting correlations, frequent patterns, associations, or causal structures between items hidden in a large database. By exploiting quantum computing, we propose an efficient quantum search algorithm design to discover the maximum frequent patterns. We modified Grover’s search algorithm so that a subspace of arbitrary symmetric states is used instead of the whole search space. We presented a novel quantum oracle design that employs a quantum counter to count the maximum frequent items and a quantum comparator to check with a minimum support threshold. The proposed derived algorithm increases the rate of the correct solutions since the search is only in a subspace. Furthermore, our algorithm significantly scales and optimizes the required number of qubits in design, which directly reflected positively on the performance. Our proposed design can accommodate more transactions and items and still have a good performance with a small number of qubits.展开更多
Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by us...Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by using the partition splicing grid technology.Used the Reynolds⁃averaged of N⁃S equation,the Reynolds stress term uses the RNG turbulence model;and based on the slip grid method,numerical calculation of the flow field with different Mach numbers,front and rear blade angles and engine state were carried out;and the change law of propeller fan characteristics and the influence of slip flow on the inlet flow field were analyzed.The blade angle was the key parameter of the propeller fan characteristic conditions.When the blade angle increases from 41°to 50°,the thrust coefficient increases by 31.2%,and the power coefficient increases by 33.4%;in the climbing state of the propeller fan,the maximum total pressure distortion at the inlet port of 6.8%;the cross section is less affected by the slip flow of the propfan;and the pressure distribution is relatively uniform,but the area of the flow channel is small.The research results can provide a solution for the matching of the counter⁃rotating propeller fan and the engine and the arrangement of the air inlet measuring rake.展开更多
文摘This study was performed in order to determine visitation at remote areas that would be unaffordable due to logistic reasons. Four TrafxTM vehicle counters, each programmed with different settings, were placed along the lone access road to remotely sense the daily use activities and count accuracy at the New Underwood Lake Public Water Access Area. Use was corroborated during daylight hours with game cameras. Data was stratified between weekdays/weekends due to differences between the two periods. Two counter settings, threshold and delay, were best when set at a value of 8, but a value of 16 for delay provided almost equal results. Overall, there were 38 counts of use per day for a total of 2318 over the 61 day period. This study demonstrated how vehicle counters, in combination with game cameras for verification, can aid managers for determining use in remote access areas. Future work may lead to identifying details for producing a surrogate to traditional angler use surveys.
文摘AIM: To evaluate the accuracy of automated blood cell counters for ascitic polymorphonuclear (PMN) determination for: (1) diagnosis, (2) efficacy of the ongoing antibiotic therapy, and (3) resolution of spontaneous bacterial peritonitis (SBP). METHODS: One hundred and twelve ascitic fluid samples were collected from 52 consecutive cirrhotic patients, 16 of them with SBP. The agreement between the manual and the automated method for PMN count was assessed. The sensitivity/specificity and the positive/negative predictive value of the automated blood cell counter were also calculated by considering the manual method as the "gold standard" RESULTS: The mean + SD of the difference between manual and automated measurements was 7.8 4- 58 cells/ram3, while the limits of agreement were +124 cells/mm3 [95% confidence interval (CI): +145 to +103] and -108 cells/mm3 (95% CI: -87 to -129). The automated cell counter had a sensitivity of 100% and a specificity of 97.7% in diagnosing SBP, and a sensitivity of 91% and a specificity of 100% for the efficacy of the ongoing antibiotic therapy. The two methods showed a complete agreement for the resolution of infection. CONCLUSION: Automated cell counters not only have a good diagnostic accuracy, but are also very effectivein monitoring the antibiotic treatment in patients with SBP. Because of their quicker performance, they should replace the manual counting for PMN determination in the ascitic fluid of patients with SBP.
基金supported by the Central University Basic Scientific Research Business Expenses Special Funds under the project name Research on Applied Physics under Low 385 Radiation Background(No. 2018NTST07)2021 Nuclear and Radiation Safety Technic Evaluation Project,Ministry of Ecology and Environment (No.NSCCG2021-052)
文摘In vivo measurement of radioactivity based on various body counters is arguably the leading measure used to determine the distribution and activity of radionuclides in human subjects,such as I-131 in the thyroid,Am-241 in the lungs,and Pb-210 in the skull.Throughout the measurements,the radiation background is the key factor that determines the sensitivity of the counter.Therefore,to facilitate in vivo measurements,a well-designed shielding room is required to create a low-background environment.However,because the compositions of the radiation background are quite complicated,the respective contributions from each source remain obscure,which places a considerable burden on seeking an optimized design of shielding rooms that strikes the optimum balance between the construction cost and background suppression effect.In this study,we conducted a systematic experimental investigation on the radiation background outside and inside four representative body counters with assorted designs using a variety of radiation detectors,including high-purity germanium detectors,CdZnTe detector,radon emanometer,and gamma-ray dosimeter.By carefully controlling the experimental conditions and synergetic analysis of the measurement results,in conjunction with previous studies,we separated and determined the relative contributions induced by environmental radiation(4%),airborne radon and its daughters(2%),the normal radioactivity of human subjects arising from K-40(58%),cosmic rays(12%),and radioactivity in shielding materials and measuring instruments(24%).Furthermore,based on these results,we discuss practical guidelines to design a shielding room for body counters.
文摘The performances of four optical particles counters, Aerosol Spectrometer (Grimm 1.108), Enviro Check (Grimm 1.107), DustMonit and ParticleScan, were evaluated in laboratory tests employing monodisperse aerosol particles. The study focused on how commercial instruments perform during routine measurements respect to OPC scientific understanding, because it is important for users of such instruments to be aware of their limitations. Measurements were performed using aerosol generated by a Monodisperse Aerosol Generator (MAGE), which produced carnauba wax particles of diameter (1.00 ± 0.08) μm and (1.40 ± 0.15) μm, and monodisperse Polystyrene Latex (PSL) aerosol with nominal diameter of 1.0mm. The results show comparable total particle number concentrations for all the counters, when the count of the first size channel (0.3 - 0.4 μm) for the 1.108 Grimm counter was left out. In the said channel the Grimm counter 1.108 always showed much higher particle counts than those inferred from the tested aerosols. The overcount was proved by the fact that the aerosol sampled in each test on a Nuclepore filter showed no particles in the 0.3 - 0.4 μm range when examined under Scanning Electronic Microscope (SEM). The presence of an artefact produced by the counter was assumed as a likely explanation. For all the counters, the Count Median Diameters (CMDs) of aerosol size distributions, were far below the expected value for the aerosol used. The nearest CMD values to the expected ones were shown by the Grimm 1.107 counter.
文摘A simple method employing a pair of pancake-style Geiger-Mueller (GM) counters for quantitative measurement of radon activity concentration (activity per unit volume) is described and demonstrated. The use of two GM counters, together with the basic theory derived in this paper, permit the detection of alpha particles from decay of and progeny ( <sup>218</sup>Po, <sup>214</sup>Po) and the conversion of the alpha count rate into a radon concentration. A unique feature of this method, in comparison with standard methodologies to measure radon concentration, is the absence of a fixed control volume. Advantages afforded by the reported GM method include: 1) it provides a direct in-situ value of radon level, thereby eliminating the need to send samples to an external testing laboratory;2) it can be applied to monitoring radon levels exhibiting wide short-term variability;3) it can yield short-term measurements of comparable accuracy and equivalent or higher precision than a commercial radon monitor sampling by passive diffusion;4) it yields long-term measurements statistically equivalent to commercial radon monitors;5) it uses the most commonly employed, overall least expensive, and most easily operated type of nuclear instrumentation. As such, the method is par-ticularly suitable for use by researchers, public health personnel, and home dwellers who prefer to monitor indoor radon levels themselves. The results of a consecutive 30-day sequence of 24 hour mean radon measurements by the proposed GM method and a commercial state-of-the-art radon monitor certified for radon testing are compared.
文摘Different fuzzy reasoning methods were gave by choosing different fuzzy counters.This article generally introduced the basic structure of fuzzy controller,and compared and analysised the reasoning effect of fuzzy reasoning methods and the effect of computer simulating control basicly on different fuzzy counters.
文摘Developing a novel drop counter by introducing the Internet of Things concept has been vigorously conducted in recent years. Understanding the newly introduced drop counter’s flow rate control accuracy and flow rate count feature is essential for improving safety in infusion management. This study aimed to verify if the new drop counters could secure accurate flow rate and drip count by conducting actual flow rate measurements using gravimetry and functional evaluation. A drop counter was attached to each drip chamber of the infusion set, and an IV drip was conducted at the 100 ml/h flow rate. The weight of discharged physiological saline was measured to plot trumpet curves. Next, three different types of drop counters were evaluated to determine if they maintained drip count accuracy according to the changes in their position angles. The flow rate errors in all conditions indicated trumpet-like curves, exhibiting an overall error range within ±10% in all observation windows. Although every drop counter successfully detected and measured dripping, it was challenging in some counters to detect dripping when the drip chamber was tilted. In comparing adult and pediatric IV sets, the adult IV set was found to be less likely to detect dripping in the angled position. No significant differences in results were confirmed between high and low flow rates, suggesting that the drop count function would not be affected by the flow rate in the ranges of typical infusion practices. Doppler sensors have a wide range of measurements and high sensitivity;the dripping was detected successfully even when the drip chamber was tilted, probably due to the advantages of these sensors. In contrast, miscounts occurred in those equipped with infrared sensors, which could not detect light intensity changes in tilted positions. Understanding the tendencies in flow rate errors in infusion can be valuable information for infusion management.
文摘HANDS-ON LAB You can use positive and negative counters to model the addition of integers.The counter + represents 1,and the counter - represents-1.Remember that addition means combining two sets.ACTIVITY Work with a partner.
基金Project supported by the National Natural Science Foundation of China
文摘The optical particle counter (OPC) is widely used in the measurement of aerosol. The calculation results of response curves for several commercial counters indicate that these curves are quite sensitive to the refractive index, especially to its imaginary part. If the particle sizes were determined with the cali-
基金This work is supported by the National Key Research and Development Program of China under Grant No.2018YFB1004804the National Natural Science Foundation of China under Grant No.61702492the Shenzhen Basic Research Program under Grant Nos.JCYJ20170818153016513 and JCYJ20170307164747920,and Alibaba Innovative Research(AIR)Project.
文摘Workload characterization is critical for resource management and scheduling.Recently,with the fast development of container technique,more and more cloud service providers like Google and Alibaba adopt containers to provide cloud services,due to the low overheads.However,the characteristics of co-located diverse services(e.g.,interactive on-line services,off-line computing services)running in containers are still not clear.In this paper,we present a comprehensive analysis of the characteristics of co-located workloads running in containers on the same server from the perspective of hardware events.Our study quantifies and reveals the system behavior from the micro-architecture level when workloads are running in different co-location patterns.Through the analysis of typical hardware events,we provide recommended/unrecommended co-location workload patterns which provide valuable deployment suggestions for datacenter administrators.
文摘To enhance the accuracy of 2πα and 2πβ particle surface emission rate measurements and address the identification issues of nuclides in conventional methods, this study introduces two artificial neural network(ANN) algorithms: back-propagation(BP) and genetic algorithm-based back-propagation(GA-BP). These algorithms classify pulse signals from distinct α and β particles. Their discrimination efficacy is assessed by simulating standard pulse signals and those produced by contaminated sources, mixing α and β particles within the detector. This study initially showcases energy spectrum measurement outcomes, subsequently tests the ANNs on the measurement and validation datasets, and contrasts the pulse shape discrimination efficacy of both algorithms. Experimental findings reveal that the proportional counter's energy resolution is not ideal, thus rendering energy analysis insufficient for distinguishing between 2πα and 2πβ particles. The BP neural network realizes approximately 99% accuracy for 2πα particles and approximately 95% for 2πβ particles, thus surpassing the GA-BP's performance. Additionally, the results suggest enhancing β particle discrimination accuracy by increasing the digital acquisition card's threshold lower limit. This study offers an advanced solution for the 2πα and 2πβ surface emission rate measurement method, presenting superior adaptability and scalability over conventional techniques.
文摘Introduction: Maternal death or maternal mortality is “the death of a woman occurring during pregnancy or within 42 days of termination, regardless of duration or location, for any specific cause or aggravated by pregnancy or its management, but neither accidental nor fortuitous. Methods: This was a descriptive and analytical cross-sectional study carried out from January 1<sup>st</sup>, 2021 to April 30<sup>th</sup>, 2022 at the Obstetrics Gynecology Clinic of the Sylvanus Olympio University Hospital Center (SOUHC). Results: we noted 86 cases of maternal deaths after referral/evacuation i.e. a maternal mortality rate hospital of 555 maternal deaths per 100,000 LB. The average age of the patients was 31.1 ± 6.3 years with extremes of 15 and 45 years. In 33.7% of cases our patients were resellers. Multiparas represented 33.7% of the sample, they had performed less than three antenatal consultations. Postpartum hemorrhage was the reference reason in 33.7%. In 74.4% of cases, the patients referred had arrived by taxi. In 87.9% of cases, the patients had died of direct obstetric causes. Immediate postpartum hemorrhage accounted for 44.6% of cases and anemia, 36.4%. There is a statistically significant association between the availability of blood product and the avoidability of maternal death after obstetrical referral and/or evacuation (p value = 0.0188 0.05). Conclusion: Determining responsibility for maternal death is not always easy. There is an urgent need to strengthen the policy of reducing maternal mortality in Togo. This remains possible by developing communication strategies and a solid referral/counter-referral system.
文摘In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.
文摘Maximum frequent pattern generation from a large database of transactions and items for association rule mining is an important research topic in data mining. Association rule mining aims to discover interesting correlations, frequent patterns, associations, or causal structures between items hidden in a large database. By exploiting quantum computing, we propose an efficient quantum search algorithm design to discover the maximum frequent patterns. We modified Grover’s search algorithm so that a subspace of arbitrary symmetric states is used instead of the whole search space. We presented a novel quantum oracle design that employs a quantum counter to count the maximum frequent items and a quantum comparator to check with a minimum support threshold. The proposed derived algorithm increases the rate of the correct solutions since the search is only in a subspace. Furthermore, our algorithm significantly scales and optimizes the required number of qubits in design, which directly reflected positively on the performance. Our proposed design can accommodate more transactions and items and still have a good performance with a small number of qubits.
文摘Taking a propfan engine as the research object,the CFD method was used for 3D modeling and unsteady slip flow for numerical calculation.The propfan rotation domain and the nacelle outside flow domain were meshed by using the partition splicing grid technology.Used the Reynolds⁃averaged of N⁃S equation,the Reynolds stress term uses the RNG turbulence model;and based on the slip grid method,numerical calculation of the flow field with different Mach numbers,front and rear blade angles and engine state were carried out;and the change law of propeller fan characteristics and the influence of slip flow on the inlet flow field were analyzed.The blade angle was the key parameter of the propeller fan characteristic conditions.When the blade angle increases from 41°to 50°,the thrust coefficient increases by 31.2%,and the power coefficient increases by 33.4%;in the climbing state of the propeller fan,the maximum total pressure distortion at the inlet port of 6.8%;the cross section is less affected by the slip flow of the propfan;and the pressure distribution is relatively uniform,but the area of the flow channel is small.The research results can provide a solution for the matching of the counter⁃rotating propeller fan and the engine and the arrangement of the air inlet measuring rake.