This study was designed to evaluate efficacy and stability of corneal collagen crosslinking(CXL) in halting the progression of post-laser in situ keratomileusis(LASIK) ectasia and provide long-term follow-up results w...This study was designed to evaluate efficacy and stability of corneal collagen crosslinking(CXL) in halting the progression of post-laser in situ keratomileusis(LASIK) ectasia and provide long-term follow-up results with an average of 80 mo. Patients with post-LASIK ectasia were treated with CXL between December 2007 and January 2012. Main outcome measures were uncorrected distance visual acuities(UDVA) and corrected distance visual acuities(CDVA), minimum and maximum keratometry(K) values, spherical and cylindrical refraction, and corneal thickness. The study evaluated 17 eyes for 13 patients(8 men, 5 women) with mean age of 31y(range 23 to 39) and mean follow-up of 80.7±15(range 57 to 102)mo. UDVA and CDVA improved from logMAR 0.53±0.36(20/63) to 0.49±0.4(20/50)(P=0.43) and from 0.18±0.17(20/28) to 0.16±0.16(20/27)(P=0.55) respectively. In 15 eyes UDVA and in 13 eyes CDVA either remained stable or improved ≥1 Snellen lines(88.2%) and(76.5%) respectively. Although statistically insignificant, spherical and cylindrical refraction decreased post-CXL from-1.26±2.87 to-0.38±2.32 diopters(D)(P=0.054) and from-3.80±2.47 to-3.04±2.18 D(P=0.13) respectively. Kmax significantly decreased from 44.23±3.76 to 42.85±3.08 D(P=0.013) and Kmin decreased from 41.07±3.61 to 40.00±2.65 D(P=0.057). Corneal thickness decreased from 470±42 to 460±41 μm, but was statistically non-significant(P=0.063). Therefore, CXL is effective in halting and partially reversing the progression of postLASIK ectasia on the long-term(mean follow-up of more than 80mo), thus highlighting the stability and maintained effect of CXL for such cases.展开更多
The plastic post-buckling of a simply supported column with a solid rectangularcross-section is analysed by a new approach. High order terms in the asymptotic post-buckling expansions are carried out. In some aspect...The plastic post-buckling of a simply supported column with a solid rectangularcross-section is analysed by a new approach. High order terms in the asymptotic post-buckling expansions are carried out. In some aspects, the method proposed in thispaper is similar io Hutchinson's. However, the computation is simple since theintroduction is avoided of stretched coordinates. The method can be used to analyseinitial post-bifurcation of plates and shells in the plastic range.展开更多
The algorithm of Binary Image Cross-Correlation (BICC) was developed to measure the unsteady flow field. A vortex flow field was used to test the algorithm by numerical simulation. The results show that BICC is an e...The algorithm of Binary Image Cross-Correlation (BICC) was developed to measure the unsteady flow field. A vortex flow field was used to test the algorithm by numerical simulation. The results show that BICC is an effective algorithm for particle identification from consecutive images, the accurate velocity vector field can be obtained. The real velocity field in a valve chamber was measured by BICC in this study. From the full-field velocity information, the pressure and vorticity fields were also extracted by post-processing. (Edited author abstract) 6 Refs.展开更多
文摘This study was designed to evaluate efficacy and stability of corneal collagen crosslinking(CXL) in halting the progression of post-laser in situ keratomileusis(LASIK) ectasia and provide long-term follow-up results with an average of 80 mo. Patients with post-LASIK ectasia were treated with CXL between December 2007 and January 2012. Main outcome measures were uncorrected distance visual acuities(UDVA) and corrected distance visual acuities(CDVA), minimum and maximum keratometry(K) values, spherical and cylindrical refraction, and corneal thickness. The study evaluated 17 eyes for 13 patients(8 men, 5 women) with mean age of 31y(range 23 to 39) and mean follow-up of 80.7±15(range 57 to 102)mo. UDVA and CDVA improved from logMAR 0.53±0.36(20/63) to 0.49±0.4(20/50)(P=0.43) and from 0.18±0.17(20/28) to 0.16±0.16(20/27)(P=0.55) respectively. In 15 eyes UDVA and in 13 eyes CDVA either remained stable or improved ≥1 Snellen lines(88.2%) and(76.5%) respectively. Although statistically insignificant, spherical and cylindrical refraction decreased post-CXL from-1.26±2.87 to-0.38±2.32 diopters(D)(P=0.054) and from-3.80±2.47 to-3.04±2.18 D(P=0.13) respectively. Kmax significantly decreased from 44.23±3.76 to 42.85±3.08 D(P=0.013) and Kmin decreased from 41.07±3.61 to 40.00±2.65 D(P=0.057). Corneal thickness decreased from 470±42 to 460±41 μm, but was statistically non-significant(P=0.063). Therefore, CXL is effective in halting and partially reversing the progression of postLASIK ectasia on the long-term(mean follow-up of more than 80mo), thus highlighting the stability and maintained effect of CXL for such cases.
文摘The plastic post-buckling of a simply supported column with a solid rectangularcross-section is analysed by a new approach. High order terms in the asymptotic post-buckling expansions are carried out. In some aspects, the method proposed in thispaper is similar io Hutchinson's. However, the computation is simple since theintroduction is avoided of stretched coordinates. The method can be used to analyseinitial post-bifurcation of plates and shells in the plastic range.
基金The project supported by the National Natural Science Foundation of China
文摘The algorithm of Binary Image Cross-Correlation (BICC) was developed to measure the unsteady flow field. A vortex flow field was used to test the algorithm by numerical simulation. The results show that BICC is an effective algorithm for particle identification from consecutive images, the accurate velocity vector field can be obtained. The real velocity field in a valve chamber was measured by BICC in this study. From the full-field velocity information, the pressure and vorticity fields were also extracted by post-processing. (Edited author abstract) 6 Refs.