期刊文献+
共找到43,614篇文章
< 1 2 250 >
每页显示 20 50 100
Factors influencing discharge readiness among patients with mild-to-moderate ischemic stroke:a cross-sectional study
1
作者 Li-Fei Wang Niphawan Samartkit Khemaradee Masingboon 《Frontiers of Nursing》 2024年第1期57-66,共10页
Objective:To describe discharge readiness and determine whether self-efficacy,social support,and the quality of discharge teaching can predict discharge readiness among patients with mild-to-moderate ischemic stroke.M... Objective:To describe discharge readiness and determine whether self-efficacy,social support,and the quality of discharge teaching can predict discharge readiness among patients with mild-to-moderate ischemic stroke.Methods:A total of 120 patients with mild-to-moderate ischemic stroke were recruited using simple random sampling.Five instruments,namely,the Demographic Data Questionnaire,the Chinese version of the Readiness for Hospital Discharge Scale(RHDS_C),the SelfEfficacy for Managing Chronic Disease 6-Item Scale(SES6),the Perceived Social Support Scale(PSSS),and the Quality of Discharge Teaching Scale(QDTS),were used for data collection.Descriptive statistics and standard multiple linear regression were used for data analysis.Results:The mean score of discharge readiness among patients with mild-to-moderate ischemic stroke was at a moderate level(M=7.6,SD=0.92),and 75.8%of the participants felt ready for discharge.Standard multiple linear regression revealed that selfefficacy(β=0.62,P<0.001)and the quality of discharge teaching(β=0.28,P<0.001)were the influencing factors.However,social support could not predict discharge readiness significantly.All the factors combined explained 64.9%of the variance in discharge readiness.Conclusions:Intervention programs aimed at improving self-efficacy and the quality of discharge teaching may be helpful in promoting discharge readiness in patients with mild-to-moderate ischemic stroke,especially in coping ability. 展开更多
关键词 discharge readiness ischemic stroke quality of discharge teaching SELF-EFFICACY social support
下载PDF
Factors Influencing Patients to Decide to Discharge Themselves against Medical Advice at Tertiary Hospitals: A Cross-Sectional Study
2
作者 Malak Alsharif Aeshah Alatawi +2 位作者 Abdulhadi M. Alqahtani Mohammed Alufi Faisal Alghamdi 《International Journal of Clinical Medicine》 CAS 2023年第3期163-174,共12页
Background: Discharged against medical advice (DAMA) is defined as any instance when a patient wants to leave the hospital against the managing physician’s decision. This study aimed to identify factors that influenc... Background: Discharged against medical advice (DAMA) is defined as any instance when a patient wants to leave the hospital against the managing physician’s decision. This study aimed to identify factors that influence patients to decide to be DAMA. Methods: A descriptive, cross-sectional study. The study was conducted in the emergency department (ED) of King Fahad Medical City (KFMC)-Saudi Arabia-Riyadh city. A questionnaire in both Arabic and English was distributed to all participants to fill in either English or Arabic. Results: Between 1 March and 30 April 2021, 510 responses were collected. Most of the study participants (31.4%) were over the age of 54. Our findings showed that 12.5% of our participants had taken discharge against medical advice in the past. Results Regarding Factors That Influence Patients to Decide on DAMA Showed: Regarding Inappropriate behavior and disrespect of the physician or staff to the patient and his relatives, 262 (51.4%) participants, 85 (16.7%) participants, and 163 (32%) participants agreed, neutral, and disagreed, respectively. Regarding the Lack of physicians’ and nurses’ attention to the patient and his relatives (emotionally), our result showed that 278 (54.5%) participants, 95 (18.6%) participants, and 137 (26.9%) participants agreed, neutral, and disagree, respectively. Regarding failure to inform the patient or his relatives of his condition, it showed that 257 (50.4%) participants, 95 (18.6%) participants, and 158 (31%) participants agreed, neutral, and disagreed, respectively. Regarding feeling better from DAMA, our result showed 226 (44.3%) participants, 119 (23.3%) participants, and 165 (32.4%) participants agreed, neutral, and disagreed, respectively. Regarding patients’ or their relative’s tiredness of hospital stay, the result showed that 166 (32.5%) participants, 104 (20.4%) participants, and 240 (47.1%) participants agreed, neutral, and disagreed, respectively. Conclusion: The long wait time to be seen by a physician was the major factor that forced patients to leave the emergency department against medical advice. 展开更多
关键词 Against Medical Advice DAMA discharge FACTOR Saudi Arabia
下载PDF
Rationale of Cross-Sectional Descriptive Study on Clinical Effectiveness of Oral Combination Therapy Based on Secnidazole, Azithromycin and Fluconazole in Syndromic Treatment of Abnormal Vaginal Discharge in Kinshasa/DR Congo
3
作者 Muela Andy Mbangama Feruzi Michel Mangala +8 位作者 Di-Mosi-Nkoyi Roger Wumba Ambis Joelle Lumaya Nkongolo Freddy Muamba Mubalamata Eugene-Patrick Lukusa Nkashama Bienvenu Kazadi Ndombasi Nelda Lemba Banza Jésual Lotoy Oteme Christian Ndesanzim Mwimba Roger Mbungu 《Open Journal of Obstetrics and Gynecology》 2023年第11期1807-1815,共9页
Background: Vaginal discharge is one of the most common troubles faced by childbearing age women. About 20% - 25% of women who visit service of gynecology complain of vaginal discharge and leucorrhoea. Management of v... Background: Vaginal discharge is one of the most common troubles faced by childbearing age women. About 20% - 25% of women who visit service of gynecology complain of vaginal discharge and leucorrhoea. Management of vaginal discharge in low-income countries generally depends on syndromic approach, which limits the understanding of specific responsible agents. Thus targeted management is based on the identification of causal organism and targeting of therapy against it, while syndromic management is based on presence of high risk factors. Thus the oral combination kit (Azimyn FS Kit®) offers convenience of a one-day treatment compared to other multidose treatments, which will also ensure high patient adherence to treatment, thus increasing chances of desired results. Due to its widespread use, it is proposed to evaluate the effectiveness of this oral association kit therapy in management of vaginal discharge in the population of our milieu in the Democratic Republic of Congo (DRC) particularly those received in outpatient consultation in some medical facilities in city of Kinshasa. Expensive laboratory tests and the associated waiting period for result mean that patient remains without treatment while waiting for test results. Therefore, by adopting a syndromic management approach, patient’s eligibility for treatment will be decided based on abnormal vaginal discharge, their characteristics, severity and other presentations symptomatic. This approach will also avoid losing sight of patients during follow-up and will help to reduce financial burden for patients. Objectives: To determine the efficacy and safety of oral combination kit therapy containing secnidazole, azithromycin and fluconazole (Azimyn FS Kit®) in syndromic treatment of abnormal vaginal discharge in patients received in outpatient consultation in some medical facilities in the city of Kinshasa;to measure rate of recurrence of abnormal vaginal discharge in these patients. And to identify the adverse effects observed in these patients who received treatment with the combined oral kit containing secnidazole, azithromycin and fluconazole (Azimyn FS Kit®) in outpatient consultation in some medical facilities in the city of Kinshasa. Methods: It will be a cross-sectional descriptive study. Sample size will be 319 women of childbearing age who consult the gynecology department with complaint of abnormal vaginal discharge and suspicion of vaginal infection, who agree to abstain from sex during treatment and who have given their written consent to use their personal and/or health data in the study. Conclusion: A study on clinical efficacy of oral combination therapy based on secnidazole, azithromycin and fluconazole is beneficial. 展开更多
关键词 Combination Therapy Syndromic Treatment Abnormal Vaginal discharge
下载PDF
Optimization Design of the Multi-Layer Cross-Sectional Layout of An Umbilical Based on the GA-GLM 被引量:1
4
作者 YANG Zhi-xun YIN Xu +5 位作者 FAN Zhi-rui YAN Jun LU Yu-cheng SU Qi MAO Yandong WANG Hua-lin 《China Ocean Engineering》 SCIE EI CSCD 2024年第2期247-254,共8页
Marine umbilical is one of the key equipment for subsea oil and gas exploitation,which is usually integrated by a great number of different functional components with multi-layers.The layout of these components direct... Marine umbilical is one of the key equipment for subsea oil and gas exploitation,which is usually integrated by a great number of different functional components with multi-layers.The layout of these components directly affects manufacturing,operation and storage performances of the umbilical.For the multi-layer cross-sectional layout design of the umbilical,a quantifiable multi-objective optimization model is established according to the operation and storage requirements.Considering the manufacturing factors,the multi-layering strategy based on contact point identification is introduced for a great number of functional components.Then,the GA-GLM global optimization algorithm is proposed combining the genetic algorithm and the generalized multiplier method,and the selection operator of the genetic algorithm is improved based on the steepest descent method.Genetic algorithm is used to find the optimal solution in the global space,which can converge from any initial layout to the feasible layout solution.The feasible layout solution is taken as the initial value of the generalized multiplier method for fast and accurate solution.Finally,taking umbilicals with a great number of components as examples,the results show that the cross-sectional performance of the umbilical obtained by optimization algorithm is better and the solution efficiency is higher.Meanwhile,the multi-layering strategy is effective and feasible.The design method proposed in this paper can quickly obtain the optimal multi-layer cross-sectional layout,which replaces the manual design,and provides useful reference and guidance for the umbilical industry. 展开更多
关键词 UMBILICAL cross-sectional layout MULTI-LAYERS GA-GLM optimization
下载PDF
Association between triglyceride-glucose index and colorectal polyps:A retrospective cross-sectional study 被引量:1
5
作者 Ya-Jie Teng Ying-Xue Yang +5 位作者 Jing-Jing Yang Qiu-Yan Lu Jia-Yi Shi Jian-Hao Xu Jie Bao Qing-Hua Wang 《World Journal of Gastrointestinal Endoscopy》 2024年第2期55-63,共9页
BACKGROUND Colorectal polyps(CPs)are frequently occurring abnormal growths in the colorectum,and are a primary precursor of colorectal cancer(CRC).The triglyceride-glucose(TyG)index is a novel marker that assesses met... BACKGROUND Colorectal polyps(CPs)are frequently occurring abnormal growths in the colorectum,and are a primary precursor of colorectal cancer(CRC).The triglyceride-glucose(TyG)index is a novel marker that assesses metabolic health and insulin resistance,and has been linked to gastrointestinal cancers.AIM To investigate the potential association between the TyG index and CPs,as the relation between them has not been documented.METHODS A total of 2537 persons undergoing a routine health physical examination and colonoscopy at The First People's Hospital of Kunshan,Jiangsu Province,China,between January 2020 and December 2022 were included in this retrospective cross-sectional study.After excluding individuals who did not meet the eligibility criteria,descriptive statistics were used to compare characteristics between patients with and without CPs.Logistic regression analyses were conducted to determine the associations between the TyG index and the prevalence of CPs.The TyG index was calculated using the following formula:Ln[triglyceride(mg/dL)×glucose(mg/dL)/2].The presence and types of CPs was determined based on data from colonoscopy reports and pathology reports.RESULTS A nonlinear relation between the TyG index and the prevalence of CPs was identified,and exhibited a curvilinear pattern with a cut-off point of 2.31.A significant association was observed before the turning point,with an odds ratio(95% confidence interval)of 1.70(1.40,2.06),P<0.0001.However,the association between the TyG index and CPs was not significant after the cut-off point,with an odds ratio(95% confidence interval)of 0.57(0.27,1.23),P=0.1521.CONCLUSION Our study revealed a curvilinear association between the TyG index and CPs in Chinese individuals,suggesting its potential utility in developing colonoscopy screening strategies for preventing CRC. 展开更多
关键词 Triglyceride-glucose index Colorectal polyps Colorectal cancer Insulin resistance cross-sectional study
下载PDF
Study of three-dimensional spatial diffuse discharge in contact electrode structure applied to air purification
6
作者 Shuai XU Wenzheng LIU +3 位作者 Jiaying QIN Yiwei SUN Xitao JIANG Qi QI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第10期73-81,共9页
In this work,based on the role of pre-ionization of the non-uniform electric field and its effect of reducing the collisional ionization coefficient,a diffuse dielectric barrier discharge plasma is formed in the open ... In this work,based on the role of pre-ionization of the non-uniform electric field and its effect of reducing the collisional ionization coefficient,a diffuse dielectric barrier discharge plasma is formed in the open space outside the electrode structure at a lower voltage by constructing a three-dimensional non-uniform spatial electric field using a contact electrode structure.The air purification study is also carried out.Firstly,a contact electrode structure is constructed using a three-dimensional wire electrode.The distribution characteristics of the spatial electric field formed by this electrode structure are analyzed,and the effects of the non-uniform electric field and the different angles of the vertical wire on the generation of three-dimensional spatial diffuse discharge are investigated.Secondly,the copper foam contact electrode structure is constructed using copper foam material,and the effects of different mesh sizes on the electric field distribution are analyzed.The results show that as the mesh size of the copper foam becomes larger,a strong electric field region exists not only on the surface of the insulating layer,but also on the surface of the vertical wires inside the copper foam,i.e.,the strong electric field region shows a three-dimensional distribution.Besides,as the mesh size increases,the area of the vertical strong electric field also increases.However,the electric field strength on the surface of the insulating layer gradually decreases.Therefore,the appropriate mesh size can effectively increase the discharge area,which is conducive to improving the air purification efficiency.Finally,a highly permeable stacked electrode structure of multilayer wire-copper foam is designed.In combination with an ozone treatment catalyst,an air purification device is fabricated,and the air purification experiment is carried out. 展开更多
关键词 dielectric barrier discharge three-dimensional spatial discharge atmospheric pressure air diffusion discharge air purification
下载PDF
Comparative analysis of single-crater parameters in ultrasonic-assisted and unassisted micro-EDM of Ti6Al4V using discharge plasma imaging
7
作者 Sohaib Raza Chandrakant Nirala 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2024年第2期11-24,共14页
Ultrasonic-assisted micro-electro-discharge machining(EDM)has the potential to enhance processing responses such as material removal rate(MRR)and surface finish.To understand the reasons for this enhancement,the physi... Ultrasonic-assisted micro-electro-discharge machining(EDM)has the potential to enhance processing responses such as material removal rate(MRR)and surface finish.To understand the reasons for this enhancement,the physical mechanisms responsible for the individual discharges and the craters that they form need to be explored.This work examines features of craters formed by single discharges at various parameter values in both conventional and ultrasonic-assistedEDM of Ti6Al4V.High-speed imaging of the plasma channel is performed,and data on the individual discharges are captured in real-time.A 2D axisymmetric model using finite element software is established to model crater formation.On the basis of simulation and experimental results,a comparative study is then carried out to examine the effects of ultrasonic vibrational assistance on crater geometry.For every set ofEDM parameters,the crater diameter and depth from a single discharge are found to be higher in ultrasonic-assistedEDM than in conventionalEDM.The improved crater geometry and the reduced bulge formation at the crater edges are attributed to the increased melt pool velocity and temperature predicted by the model. 展开更多
关键词 Ultrasonic vibration discharge crater Plasma diameter Single discharge
下载PDF
Effect of dielectric material on the uniformity of nanosecond pulsed dielectric barrier discharge
8
作者 Wenhao ZHOU Dongxuan ZHANG +3 位作者 Xiaohui DUAN Xi ZHU Feng LIU Zhi FANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期79-87,共9页
Dielectric barrier discharge(DBD)is considered as a promising technique to produce large volume uniform plasma at atmospheric pressure,and the dielectric barrier layer between the electrodes plays a key role in the DB... Dielectric barrier discharge(DBD)is considered as a promising technique to produce large volume uniform plasma at atmospheric pressure,and the dielectric barrier layer between the electrodes plays a key role in the DBD processes and enhancing discharge uniformity.In this work,the uniformity and discharge characteristics of the nanosecond(ns)pulsed DBD with dielectric barrier layers made of alumina,quartz glass,polycarbonate(PC),and polypropylene(PP)are investigated via discharge image observation,voltage-current waveform measurement and optical emission spectral diagnosis.Through analyzing discharge image by gray value standard deviation method,the discharge uniformity is quantitatively calculated.The effects of the space electric field intensity,the electron density(Ne),and the space reactive species on the uniformity are studied with quantifying the gap voltage Ug and the discharge current Ig,analyzing the recorded optical emission spectra,and simulating the temporal distribution of Ne with a one-dimensional fluid model.It is found that as the relative permittivity of the dielectric materials increases,the space electric field intensity is enhanced,which results in a higher Ne and electron temperature(Te).Therefore,an appropriate value of space electric field intensity can promote electron avalanches,resulting in uniform and stable plasma by the merging of electron avalanches.However,an excessive value of space electric field intensity leads to the aggregation of space charges and the distortion of the space electric field,which reduce the discharge uniformity.The surface roughness and the surface charge decay are measured to explain the influences of the surface properties and the second electron emission on the discharge uniformity.The results in this work give a comprehensive understanding of the effect of the dielectric materials on the DBD uniformity,and contribute to the selection of dielectric materials for DBD reactor and the realization of atmospheric pressure uniform,stable,and reactive plasma sources. 展开更多
关键词 dielectric barrier discharge dielectric material UNIFORMITY discharge characteristics
下载PDF
On the evolution and formation of discharge morphology in pulsed dielectric barrier discharge
9
作者 陈星宇 李孟琦 +3 位作者 王威逸 张权治 彭涛 熊紫兰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期101-113,共13页
The discharge morphology of pulsed dielectric barrier discharge(PDBD) plays important roles in its applications. Here, we systematically investigated the effects of the voltage amplitude,discharge gap, and O_(2)conten... The discharge morphology of pulsed dielectric barrier discharge(PDBD) plays important roles in its applications. Here, we systematically investigated the effects of the voltage amplitude,discharge gap, and O_(2)content on the PDBD morphology, and revealed the possible underlying mechanism of the U-shaped formation. First, the morphological evolution under different conditions was recorded. A unique U-shaped region appears in the middle edge region when the gap is larger than 2 mm, while the entire discharge region remains columnar under a 2 mm gap in He PDBD. The width of the discharge and the U-shaped region increase with the increase in voltage, and decrease with the increase of the gap and O_(2)content. To explain this phenomenon,a two-dimensional symmetric model was developed to simulate the spatiotemporal evolution of different species and calculate the electric thrust. The discharge morphology evolution directly corresponds to the excited-state atomic reduction process. The electric thrust on the charged particles mainly determines the reaction region and strongly influences the U-shaped formation.When the gap is less than 2 mm, the electric thrust is homogeneous throughout the entire region,resulting in a columnar shape. However, when the gap is larger than 2 mm or O_(2)is added, the electric thrust in the edge region becomes greater than that in the middle, leading to the U-shaped formation. Furthermore, in He PDBD, the charged particles generating electric thrust are mainly electrons and helium ions, while in He/O_(2)PDBD those that generate electric thrust at the outer edge of the electrode surface are mainly various oxygen-containing ions. 展开更多
关键词 low-temperature plasma dielectric barrier discharge discharge morphology particle distribution electric thrust
下载PDF
Predictors of Abnormal Vaginal Discharge among Women of Reproductive Age in Southeast Nigeria
10
作者 Jideuma Egwim Victor Dike +5 位作者 Hope Igbonagwam Nkechinyere Oke Uzoma Amajo Akuchi Okafor Angela Izegbune Ijedimma Okafor 《International Journal of Clinical Medicine》 CAS 2024年第7期240-256,共17页
Background: An abnormal vaginal discharge is a common complaint among women of reproductive age, and it can indicate serious conditions like pelvic inflammatory disease and cervical cancer. This study aimed to assess ... Background: An abnormal vaginal discharge is a common complaint among women of reproductive age, and it can indicate serious conditions like pelvic inflammatory disease and cervical cancer. This study aimed to assess the predictors of abnormal vaginal discharge in women of reproductive age group in Imo State, Southeast Nigeria. Methods: A cross-sectional study was conducted among 368 women of reproductive age group attending the clinic at Federal University Teaching Hospital Owerri, in Imo State, Nigeria. Respondents were recruited using a systematic sampling technique. Data were collected using a pre-tested interviewer-administered questionnaire. Multivariable analysis was performed to determine predictors of abnormal vaginal discharge. Statistical significance was set at p Results: The mean age of the respondents was 30 ±  4.5 years. Predictors of abnormal vaginal discharge were: age 36 - 45 years (OR: 4.5;95% C.I: 1.023 - 8.967, p = 0.041), being a student (OR: 2.4: 95% C.I: 1.496 - 7.336, p = 0.003), use of oral contraceptives (OR: 3.4;95% C.I: 1.068 - 6.932, p = 0.010), use of water cistern (OR: 4.7;C.I: 1.654 - 5.210, p = 0.028) anal hygiene practices (OR: 2.7;95% C.I: 1.142 - 4.809, p Conclusion: These findings suggest that targeted sexual and reproductive health interventions should be provided to reduce the risk of abnormal vaginal discharge in women of reproductive age group. 展开更多
关键词 PREDICTORS ABNORMAL VAGINAL discharge
下载PDF
Discharge and mass transfer characteristics of atmospheric pressure gas-solid two-phase gliding arc
11
作者 Min ZHU Yuchen PING +2 位作者 Yinghao ZHANG Chaohai ZHANG Shuqun WU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第9期88-96,共9页
In this work,a gas-solid two-phase gliding arc discharge(GS-GAD)reactor was built.Gliding arc was formed in the gap between the blade electrodes,and solid powder was deposited on the sieve plate positioned beneath the... In this work,a gas-solid two-phase gliding arc discharge(GS-GAD)reactor was built.Gliding arc was formed in the gap between the blade electrodes,and solid powder was deposited on the sieve plate positioned beneath the blade electrodes.A range of experimental parameters,including the inter-electrode spacing,gas flow rate,applied voltage,and the type of the powder,were systematically varied to elucidate the influence of solid powder matter on the dynamics of gliding arc discharge(GAD).The discharge images were captured by ICCD and digital camera to investigate the mass transfer characteristics of GS-GAD,and the electrical parameters,such as the effective values of voltage,current,and discharge power were record to reveal the discharge characteristics of GS-GAD.The results demonstrate that powder undergoes spontaneous movement towards the upper region of the gliding arc due to the influence of electric field force.Increasing the discharge voltage,decreasing relative dielectric constant of the powder and reducing the electrode-to-sieve-plate distance all contribute to a greater involvement of powder in the GAD process,subsequently resulting in an enhanced powder concentration within the GAD region.Additionally,powder located beneath the gliding arc experiences downward resistance caused by the opposing gas flow and arc.Excessive gas flow rate notably hampers the powder concentration within the discharge region,and the velocity of powder motion in the upper part of the GAD region is reduced.Under the condition of electrode-to-sieve-plate distance of 30 mm,gas flow rate of 1.5 L/min,and peak-to-peak voltage of 31 kV,the best combination of arc gliding and powder spark discharge phenomena can be achieved with the addition of Al_(2)O_(3) powder. 展开更多
关键词 gliding arc discharge atmospheric pressure plasma multiphase discharge mass transfer
下载PDF
Experimental study on the effect of H_(2)O and O_(2) on the degradation of SF_(6) by pulsed dielectric barrier discharge
12
作者 李亚龙 万昆 +5 位作者 王宇非 张晓星 杨照迪 傅明利 卓然 王邸博 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期125-131,共7页
SF_(6) has excellent insulation performance and arc extinguishing ability,and is widely used in the power industry.However,its global warming potential is about 23,500 times that of C0_(2),it can exist stably in the a... SF_(6) has excellent insulation performance and arc extinguishing ability,and is widely used in the power industry.However,its global warming potential is about 23,500 times that of C0_(2),it can exist stably in the atmosphere,it is not easily degradable and is of great potential harm to the environment.Based on pulsed dielectric barrier discharge plasma technology,the effects of H_(2)O and 0_(2) on the degradation of SF_(6) were studied.Studies have shown that H_(2)O can effectively promote the decomposition of SF_(6) and improve its degradation rate and energy efficiency of degradation.Under the action of a pulse input voltage and input frequency of 15 kV and 15 kHz,respectively,when H_(2)O is added alone the effect of 1% H_(2)O is the best,and the rate and energy efficiency of degradation of SF_(6) reach their maximum values,which are 91.9% and 8.25 g kWh^(-1),respectively.The synergistic effect of H_(2)O and O_(2) on the degradation of SF_(6) was similar to that of H_(2)O.When the concentration of H_(2)O and O_(2) was 1%,the system obtained the best rate and energy efficiency of degradation,namely 89.7% and 8.05 g kWh~(-1),respectively.At the same time,different external gases exhibit different capabilities to regulate decomposition products.The addition of H_(2)O can effectively improve the selectivity of S0_(2).Under the synergistic effect of H_(2)O and O_(2),with increase in O_(2) concentration the degradation products gradually transformed into SO_(2)F_(2).From the perspective of harmless treatment of the degradation products of SF_(6),the addition of O_(2) during the SF_(6) degradation process should be avoided. 展开更多
关键词 SF_(6) pulsed dielectric barrier discharge DEGRADATION discharge gas
下载PDF
Novel method for identifying the stages of discharge underwater based on impedance change characteristic
13
作者 高崇 康忠健 +3 位作者 龚大建 张扬 王玉芳 孙一鸣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期133-145,共13页
It is difficult to determine the discharge stages in a fixed time of repetitive discharge underwater due to the arc formation process being susceptible to external environmental influences. This paper proposes a novel... It is difficult to determine the discharge stages in a fixed time of repetitive discharge underwater due to the arc formation process being susceptible to external environmental influences. This paper proposes a novel underwater discharge stage identification method based on the Strong Tracking Filter(STF) and impedance change characteristics. The time-varying equivalent circuit model of the discharge underwater is established based on the plasma theory analysis of the impedance change characteristics and mechanism of the discharge process. The STF is used to reduce the randomness of the impedance of repeated discharges underwater, and then the universal identification resistance data is obtained. Based on the resistance variation characteristics of the discriminating resistance of the pre-breakdown, main, and oscillatory discharge stages, the threshold values for determining the discharge stage are obtained. These include the threshold values for the resistance variation rate(K) and the moment(t).Experimental and error analysis results demonstrate the efficacy of this innovative method in discharge stage determination, with a maximum mean square deviation of Scrless than 1.761. 展开更多
关键词 discharge underwater discharge stage identification impedance characteristics strong tracking filter
下载PDF
Integrated design and performance optimization of three-electrode sliding discharge plasma power supply
14
作者 Borui ZHENG Linwu WANG +4 位作者 Jianbo ZHANG Shaojie QI Yuhong CHEN Haodong LIU Dongliang BIAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第11期152-161,共10页
The three-electrode sliding dielectric barrier discharge(TES-DBD) plasma actuator significantly enhances the ionization rate and momentum exchange between charged particles and neutral particles by incorporating a par... The three-electrode sliding dielectric barrier discharge(TES-DBD) plasma actuator significantly enhances the ionization rate and momentum exchange between charged particles and neutral particles by incorporating a parallel DC electrode into the standard DBD design. This design improves the body force and induced jet velocity while allowing flexible control of the induced jet angle, overcoming the limitations of discharge extension and uncontrollable direction in traditional DBD plasma actuators. An integrated plasma power supply has been designed specifically for TES-DBD plasma actuators, streamlining the power supply management. The methodology involves designing the circuit topology for the TES-DBD power supply, followed by simulating and validating its operating principles using Multisim software. The operational performance of the power supply is evaluated through a comprehensive analysis of its electrical,thermal, and aerodynamic properties specific to TES-DBD plasma actuation. 展开更多
关键词 plasma flow control dielectric barrier discharge three-electrode sliding discharge plasma power supply
下载PDF
Analyses of nonequilibrium transport in atmospheric-pressure direct-current argon discharge under different modes
15
作者 Ziming ZHANG Chuan FANG +2 位作者 Yaoting WANG Lanyue LUO Heping LI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第11期107-126,共20页
The key plasma parameters under different discharge modes, such as heavy-particle and electron temperatures, electron number density, and nonequilibrium volume of plasmas, play important roles in various applications ... The key plasma parameters under different discharge modes, such as heavy-particle and electron temperatures, electron number density, and nonequilibrium volume of plasmas, play important roles in various applications of gas discharge plasmas. In this study, a self-consistent two-dimensional nonequilibrium fluid model coupled with an external circuit model is established to reveal the mechanisms related to the discharge modes, including the normal glow, abnormal glow,arc, and glow-to-arc transition modes, with an atmospheric-pressure direct-current(DC) argon discharge as a model plasma system. The modeling results show that, under different discharge modes, the most significant difference between the preceding four discharge modes lies in the current and energy transfer processes on the cathode side. On one hand, the current to the cathode surface is mainly delivered by the ions coming from the plasma column under the glow discharge mode due to the low temperature of the solid cathode, whereas the thermionic and secondary electrons emitted from the hot cathode surface play a very important role under the arc mode with a higher cathode surface temperature and higher ion flux toward the cathode. On the other hand, the energy transfer channel on the cathode side changes from mainly heating the solid cathode under the glow mode to simultaneously heating both the solid cathode and plasma column under the arc mode with an increase in the discharge current. Consequently, the power density in the cathode sheath(P_c) was used as a key parameter for judging different discharge modes, and the range of(0.28–1.2) × 10^(12) W m^(-3) was determined as a critical window of P_c corresponding to the glow-to-arc-mode transition for the atmospheric-pressure DC argon discharge, which was also verified by comparison with the experimental results in this study and the data in the previous literature. 展开更多
关键词 atmospheric-pressure plasma direct-current gas discharge discharge mode mode transition power density in cathode sheath
下载PDF
Experimental study of the effect of gas discharge on ionic liquid electrospray
16
作者 石文 杨鹏飞 +1 位作者 宋培义 吴健 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期37-43,共7页
Ionic liquid electrospray(ILE) in an atmospheric environment is often accompanied by the gas discharge phenomenon. It interferes with the normal operation of the electrospray and the measurement of experimental parame... Ionic liquid electrospray(ILE) in an atmospheric environment is often accompanied by the gas discharge phenomenon. It interferes with the normal operation of the electrospray and the measurement of experimental parameters. In this study, electrospray experiments were conducted on the ionic liquid EMI-BF4. The observations revealed that the operating modes of the ionic liquid depend on the voltage polarity at high voltages. Additionally, a correspondence between the operating mode of ILE and the current signal in the circuit was established. The shape of the liquid cone formed at the needle tip bore a striking resemblance to the plume of corona discharge, suggesting that the motion trajectory of electrons influenced the curvature of the liquid cone. Steamer theory provided a clear explanation for the change in curvature as the voltage increased. 展开更多
关键词 ionic liquid ELECTROSPRAY Taylor cone jet corona discharge
下载PDF
Degradation of ciprofloxacin hydrochloride in a multiphase mixed system by subaquatic gas-liquid discharge plasma
17
作者 Mengyu WANG Jianping LIANG +5 位作者 Ke LU Zikai ZHOU Qinghua LIU Hao YUAN Wenchun WANG Dezheng YANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第11期144-151,共8页
In recent years, antibiotic pollution has become a serious threat to human health. In this study, a gas-liquid discharge plasma is developed to degrade ciprofloxacin hydrochloride in a multiphase mixed system containi... In recent years, antibiotic pollution has become a serious threat to human health. In this study, a gas-liquid discharge plasma is developed to degrade ciprofloxacin hydrochloride in a multiphase mixed system containing inorganic and organic impurities. The discharge characteristics are analyzed by diagnosing the applied voltage and discharge current waveforms, as well as the optical emission spectra. The work investigates how degradation efficiency is affected by applied voltage, gas flow rate, treatment time, initial concentration as well as the addition of γ-Al_(2)O_(3) pellets and peanut straw. After 70 min, the degradation efficiency of ciprofloxacin hydrochloride in the multiphase mixed system reached 99.6%. Its removal efficiency increases as the initial concentration decreases and the applied voltage increases. Besides, there is still a good degradation efficiency of ciprofloxacin hydrochloride with the addition of peanut straw.The degradation mechanism of ciprofloxacin hydrochloride is investigated through the analysis of degraded intermediates and reactive species. 展开更多
关键词 antibiotic gas-liquid discharge multiphase mixed system ciprofloxacin hydrochloride degradation
下载PDF
Role of micro-Ca/In alloying in tailoring the microstructural characteristics and discharge performance of dilute Mg-Bi-Sn-based alloys as anodes for Mg-air batteries
18
作者 Fei-er Shangguan Wei-li Cheng +6 位作者 Yu-hang Chen Ze-qin Cui Hui Yu Hong-xia Wang Li-fei Wang Hang Li Hua Hou 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期251-266,共16页
The influence of micro-Ca/In alloying on the microstructural charac teristics,electrochemical behaviors and discharge properties of extruded dilute Mg-0.5Bi-0.5Sn-based(wt.%)alloys as anodes for Mg-air batteries are e... The influence of micro-Ca/In alloying on the microstructural charac teristics,electrochemical behaviors and discharge properties of extruded dilute Mg-0.5Bi-0.5Sn-based(wt.%)alloys as anodes for Mg-air batteries are evaluated.The grain size and texture intensity of the Mg-Bi-Sn-based alloys are significantly decreased after the Ca/In alloying,particularly for the In-containing alloy.Note that,in addition to nanoscale Mg_(3)Bi_(2)phase,a new microscale Mg_(2)Bi_(2)Ca phase forms in the Ca-containing alloy.The electrochemical test results demonstrate that Ca/In micro-alloying can enhance the electrochemical activity.Using In to alloy the Mg-Bi-Sn-based alloy is effective in restricting the cathodic hydrogen evolution(CHE)kinetics,leading to a low self-corrosion rate,while severe CHE occurred after Ca alloying.The micro-alloying of Ca/In to Mg-Bi-Sn-based alloy strongly deteriorates the compactness of discharge products film and mitigates the"chunk effect"(CE),hence the cell voltage,anodic efficiency as well as discharge capacity are greatly improved.The In-containing alloy exhibits outstanding discharge performance under the combined effect of the modified microstructure and discharge products,thus making it a potential anode material for primary Mg-air battery. 展开更多
关键词 Mg-air batteries Mg-Bi-Sn based alloys Electrochemical behaviors discharge properties
下载PDF
Discharge evolution law of debris flow based on a sharp bend physical modeling test
19
作者 LU Ming SUN Hao +3 位作者 LIU Jinfeng Abrar HUSSAIN SHANG Yuqi FU Hang 《Journal of Mountain Science》 SCIE CSCD 2024年第6期1904-1915,共12页
For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,th... For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,this study aims to analyze the shear force of debris flows within the bend channel.We established the relationship between the shear force and bend curvature through laboratory experiments.Under the long-term erosion by debris flows,the curvature radius of bends gradually increases,however,when this increasing trend reaches an equilibrium state with the intensity of debris flow discharge,there will be no significant change in curvature radius.In general,the activity pattern and discharges of debris flows would remain relatively stable.Hence,we can infer the magnitude of debris flow discharges from the terrain parameters of the bend channel. 展开更多
关键词 Debris flow discharge Erosion effect Bend channel Curvature radius
下载PDF
Study on plasma expansion model of primary discharge on spacecraft solar array
20
作者 Dejie WEI Jianwen WU Liying ZHU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第11期87-95,共9页
In the space plasma environment, primary discharge may occur on the solar array and evolve into a destructive sustained arc, which threatens the safe operation of the spacecraft. Based on the plasma expansion fluid th... In the space plasma environment, primary discharge may occur on the solar array and evolve into a destructive sustained arc, which threatens the safe operation of the spacecraft. Based on the plasma expansion fluid theory, a new multicomponent plasma expansion model is proposed in this study, which takes into account the effects of ion species, ion number, initial discharge current, and Low Earth Orbit(LEO) plasma environment. The expansion simulation of single-component and multicomponent ions is carried out respectively, and the variations of plasma number density, expansion distance, and speed during the expansion process are obtained.Compared with the experimental results, the evolution of propagation distance and speed is closed and the error is within a reasonable range, which verifies the validity and rationality of the model. The propagation characteristics of the primary discharge on the solar array surface and the influence of the initial value on the maximum propagation distance and the propagation current peaks are investigated. This study can provide important theoretical support for the propagation and evolution of the primary discharge and the key behavior of the transition to secondary discharge on spacecraft solar array. 展开更多
关键词 primary discharge plasma expansion propagation characteristics spacecraft solar array
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部