期刊文献+
共找到664篇文章
< 1 2 34 >
每页显示 20 50 100
A NEW ELECTROMAGNETIC IMAGING SCHEME
1
作者 Zhang, RF He, JS 《中国有色金属学会会刊:英文版》 CSCD 1997年第2期2-4,共3页
ANEWELECTROMAGNETICIMAGINGSCHEME①ZhangRongfeng,HeJishanColegeofResource,EnvironmentandCivilEnginering,Centra... ANEWELECTROMAGNETICIMAGINGSCHEME①ZhangRongfeng,HeJishanColegeofResource,EnvironmentandCivilEnginering,CentralSouthUniversityo... 展开更多
关键词 electromagnetic imaging BORN APPROXIMATION INVERSION
下载PDF
A study on the discrete image method for calculation of transient electromagnetic fields in geological media 被引量:1
2
作者 孟庆鑫 潘和平 骆淼 《Applied Geophysics》 SCIE CSCD 2015年第4期493-502,626,627,共12页
We conducted a study on the numerical calculation and response analysis of a transient electromagnetic field generated by a ground source in geological media. One solution method, the traditional discrete image method... We conducted a study on the numerical calculation and response analysis of a transient electromagnetic field generated by a ground source in geological media. One solution method, the traditional discrete image method, involves complex operation, and its digital filtering algorithm requires a large number of calculations. To solve these problems, we proposed an improved discrete image method, where the following are realized: the real number of the electromagnetic field solution based on the Gaver-Stehfest algorithm for approximate inversion, the exponential approximation of the objective kernel function using the Prony method, the transient electromagnetic field according to discrete image theory, and closed-form solution of the approximate coefficients. To verify the method, we tentatively calculated the transient electromagnetic field in a homogeneous model and compared it with the results obtained from the Hankel transform digital filtering method. The results show that the method has considerable accuracy and good applicability. We then used this method to calculate the transient electromagnetic field generated by a ground magnetic dipole source in a typical geoelectric model and analyzed the horizontal component response of the induced magnetic field obtained from the "ground excitation-stratum measurement method. We reached the conclusion that the horizontal component response of a transient field is related to the geoelectric structure, observation time, spatial location, and others. The horizontal component response of the induced magnetic field reflects the eddy current field distribution and its vertical gradient variation. During the detection of abnormal objects, positions with a zero or comparatively large offset were selected for the drill- hole measurements or a comparatively long observation delay was adopted to reduce the influence of the ambient field on the survey results. The discrete image method and forward calculation results in this paper can be used as references for relevant research. 展开更多
关键词 Discrete image method Transient electromagnetic fields Borehole transientelectromagnetic method Horizontal component response
下载PDF
Flow pattern identification in oil wells by electromagnetic image logging 被引量:3
3
作者 Liu Zaibin Wu Xiling 《Petroleum Science》 SCIE CAS CSCD 2012年第3期303-309,共7页
Petroleum production logging needs to determine the interpretation models first and flow pattern identification is the foundation, but traditional flow pattern identification methods have some limitations. In this pap... Petroleum production logging needs to determine the interpretation models first and flow pattern identification is the foundation, but traditional flow pattern identification methods have some limitations. In this paper, a new method of flow pattern identification in oil wells by electromagnetic image logging is proposed. First, the characteristics of gas-water and oil-water flow patterns in horizontal and vertical wellbores are picked up. Then, the continuous variation of the two phase flow pattern in the vertical and horizontal pipe space is discretized into continuous fluid distribution models in the pipeline section. Second, the electromagnetic flow image measurement responses of all the eight fluid distribution models are simulated and the characteristic vector of each response is analyzed in order to distinguish the fluid distribution models. Third, the time domain changes of the fluid distribution models in the pipeline section are used to identify the flow pattern. Finally, flow simulation experiments using electromagnetic flow image logging are operated and the experimental and simulated data are compared. The results show that the method can be used for flow pattern identification of actual electromagnetic image logging data. 展开更多
关键词 electromagnetic image logging two phase flow flow pattern identification fluid distribution model
下载PDF
Image information transfer via electromagnetically induced transparency-based slow light
4
作者 王潇潇 孙家翔 +7 位作者 孙远航 李爱军 陈怡 张晓军 康智慧 王磊 王海华 高锦岳 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期252-255,共4页
In this work, we experimentally demonstrate an image information transfer between two channels by using slow light based on electromagnetically induced transparency(EIT) in a solid. The probe optical image is slowed... In this work, we experimentally demonstrate an image information transfer between two channels by using slow light based on electromagnetically induced transparency(EIT) in a solid. The probe optical image is slowed due to steep dispersion induced by EIT. By applying an additional control field to an EIT-driven medium, the slowed image is transferred into two information channels. Image intensities between two information channels can be controlled by adjusting the intensities of the control fields. The similarity of output images is further analyzed. This image information transfer allows for manipulating images in a controlled fashion, and will be important in further information processing. 展开更多
关键词 electromagnetically induced transparency slow light four-wave mixing image transfer
下载PDF
Numerical analysis of multicomponent responses of surface-hole transient electromagnetic method 被引量:3
5
作者 孟庆鑫 胡祥云 +1 位作者 潘和平 周峰 《Applied Geophysics》 SCIE CSCD 2017年第1期175-186,192,共13页
We calculate the multicomponent responses of surface-hole transient electromagnetic method. The methods and models are unsuitable as geoelectric models of conductive surrounding rocks because they are based on regular... We calculate the multicomponent responses of surface-hole transient electromagnetic method. The methods and models are unsuitable as geoelectric models of conductive surrounding rocks because they are based on regular local targets. We also propose a calculation and analysis scheme based on numerical simulations of the subsurface transient electromagnetic fields. In the modeling of the electromagnetic fields, the forward modeling simulations are performed by using the finite-difference time-domain method and the discrete image method, which combines the Gaver–Stehfest inverse Laplace transform with the Prony method to solve the initial electromagnetic fields. The precision in the iterative computations is ensured by using the transmission boundary conditions. For the response analysis, we customize geoelectric models consisting of near-borehole targets and conductive wall rocks and implement forward modeling simulations. The observed electric fields are converted into induced electromotive force responses using multicomponent observation devices. By comparing the transient electric fields and multicomponent responses under different conditions, we suggest that the multicomponent-induced electromotive force responses are related to the horizontal and vertical gradient variations of the transient electric field at different times. The characteristics of the response are determined by the varying the subsurface transient electromagnetic fields, i.e., diffusion, attenuation and distortion, under different conditions as well as the electromagnetic fields at the observation positions. The calculation and analysis scheme of the response consider the surrounding rocks and the anomalous field of the local targets. It therefore can account for the geological data better than conventional transient field response analysis of local targets. 展开更多
关键词 Surface-hole transient electromagnetic method multicomponent response analysis transient electric field three-dimensional finite-difference time-domain method discrete image method
下载PDF
Electromagnetic holographic sensitivity field of two-phase flow in horizontal wells 被引量:2
6
作者 张阔 吴锡令 +1 位作者 闫景富 蔡家铁 《Applied Geophysics》 SCIE CSCD 2017年第1期40-48,189,共10页
Electromagnetic holographic data are characterized by two modes, suggesting that image reconstruction requires a dual-mode sensitivity field as well. We analyze an electromagnetic holographic field based on tomography... Electromagnetic holographic data are characterized by two modes, suggesting that image reconstruction requires a dual-mode sensitivity field as well. We analyze an electromagnetic holographic field based on tomography theory and Radon inverse transform to derive the expression of the electromagnetic holographic sensitivity field (EMHSF). Then, we apply the EMHSF calculated by using finite-element methods to flow simulations and holographic imaging. The results suggest that the EMHSF based on the partial derivative of radius of the complex electric potential φ is closely linked to the Radon inverse transform and encompasses the sensitivities of the amplitude and phase data. The flow images obtained with inversion using EMHSF better agree with the actual flow patterns. The EMHSF overcomes the limitations of traditional single-mode sensitivity fields. 展开更多
关键词 electromagnetic holographic sensitivity field (EMHSF) holographic physical detection field finite-element method holographic imaging
下载PDF
Role of Electromagnetic Stimulation in the Treatment of Osteonecrosis of the Femoral Head in Early Stages 被引量:9
7
作者 Juan L. Cebrián Guillermo L. Milano +3 位作者 Alberto Francés Yaiza Lopiz Fernando Marco Luis López-Durán 《Journal of Biomedical Science and Engineering》 2014年第5期252-257,共6页
Osteonecrosis of the femoral head is a disorder that leads to collapse and osteoarthritis in young patients. This study examines the effectiveness of pulsed electromagnetic fields [PEMF] in the treatment of osteonecro... Osteonecrosis of the femoral head is a disorder that leads to collapse and osteoarthritis in young patients. This study examines the effectiveness of pulsed electromagnetic fields [PEMF] in the treatment of osteonecrosis of the head in precollapse bone stages. A retrospective evaluation was done of 51 patients including 70 hips with symptomatic osteonecrosis of the hip treated with pulsed electromagnetic fields. Criteria for inclusion in the study group were evidence of osteonecrosis and absence of collapse of the femoral head. The average follow-up was 26 months (range, 18 - 90). Etiologies included idiopathic (40 cases), steroid use (26) and alcohol (4). To demonstrate the existence of osteonecrosis and its evolution, magnetic resonance imaging [MRI] and plain radiography techniques were used. Results: Procedures were radiological success in 80% of cases, and no progression to collapse in 88.57% of hips. Eight of the 70 hips had radiographic progression to collapse. This study suggests that selected PEMF reduce the incidence of progression of osteonecrosis of femoral head in early stage. 展开更多
关键词 OSTEONECROSIS COLLAPSE PULSED electromagnetic FIELDS Magnetic RESONANCE imaging
下载PDF
Biomedical microwave-induced thermoacoustic imaging 被引量:4
8
作者 Qiang Liu Xiao Liang +3 位作者 Weizhi Qi Yubin Gong Huabei Jiang Lei Xi 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2022年第4期13-48,共36页
Microwave induced thermoacoustic imaging(MTAI)has emerged as a potential biomedical imaging modality with over 20-year growth.MTAI typically employs pulsed microwave as the pumping source,and detects the microwave-ind... Microwave induced thermoacoustic imaging(MTAI)has emerged as a potential biomedical imaging modality with over 20-year growth.MTAI typically employs pulsed microwave as the pumping source,and detects the microwave-induced ultrasound wave via acoustic transducers.Therefore,it features high acoustic resolution,rich elect romagnetic contrast,and large imaging depth.Benefiting from these unique advantages,MTAI has been extensively applied to various fields including pathology,biology,material and medicine.Till now,MTAI has been deployed for a wide range of biomedical applications,including cancer diagnosis,joint evaluation,brain in-vestigation and endoscopy.This paper provides a comprehensive review on(1)essential physics(endogenous/exogenous contrast mechanisms,penetration depth and resolution),(2)hardware configurations and software implementations(excit ation source,antenna,ultrasound detector and image recovery algorithm),(3)animal studies and clinical applications,and(4)future directions. 展开更多
关键词 Thermoacoustic imaging biomedical imaging electromagnetic radiation acoustic waves biomedical image processing
下载PDF
Imaging technologies in oilfield applications 被引量:2
9
作者 XIE C.G. NORTH R. +3 位作者 WILT M. ZHANG P. DENACLARA H. LEVESQUE C. 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第12期1394-1400,共7页
In this paper, we describe some recent imaging technologies developed by Schlumberger for oilfield downhole mul- tiphase flow production logging (PL) and cross-well electromagnetic (EM) survey applications. FloScan Im... In this paper, we describe some recent imaging technologies developed by Schlumberger for oilfield downhole mul- tiphase flow production logging (PL) and cross-well electromagnetic (EM) survey applications. FloScan Imager (FSITM) has been introduced as a 3-phase oil/gas/water flow PL tool for deviated and horizontal wells. FSI sensors can map fluid velocity and holdup profiles along a vertical diameter of the wellbore at every survey depth, enabling a robust estimate of the individual phase flow rates in complex flow regimes. The cross-well EM survey is based on cross-borehole induction logging technique and provides resistivity distribution at a reservoir scale. It is a useful tool for reservoir management and is most effective in dynamic fields where fluid saturations are variable in time and space. The tool can be used to identify (water or steam) flooded and bypassed regions. By monitoring changes in the resistivity spatial distribution with time, cross-well EM survey is very effective at mapping inter-well temperature and structure. Some field examples are shown for both FloScan Imager PL tool and cross-well resistivity imaging survey. 展开更多
关键词 OILFIELD Production logging (PL) Multiphase flow imaging TOMOGRAPHY cross-well resistivity
下载PDF
Electromagnetic Tomography System for Defect Detection of High-Speed Rail Wheel 被引量:1
10
作者 Yu Miao Xianglong Liu +4 位作者 Ze Liu Yuanli Yue Jianli Wu Jiwei Huo Yong Li 《Journal of Beijing Institute of Technology》 EI CAS 2020年第4期474-483,共10页
A novel electromagnetic tomography(EMT)system for defect detection of high-speed rail wheel is proposed,which differs from traditional electromagnetic tomography systems in its spatial arrangements of coils.A U-shaped... A novel electromagnetic tomography(EMT)system for defect detection of high-speed rail wheel is proposed,which differs from traditional electromagnetic tomography systems in its spatial arrangements of coils.A U-shaped sensor array was designed,and then a simulation model was built with the low frequency electromagnetic simulation software.Three different algorithms were applied to perform image reconstruction,therefore the defects can be detected from the reconstructed images.Based on the simulation results,an experimental system was built and image reconstruction were performed with the measured data.The reconstructed images obtained both from numerical simulation and experimental system indicated the locations of the defects of the wheel,which verified the feasibility of the EMT system and revealed its good application prospect in the future. 展开更多
关键词 electromagnetic tomography(EMT) high-speed rail wheel defect detection image reconstruction
下载PDF
Electromagnetic Expansion and Fragmentation of Hollow Aluminium 5052 Tube
11
作者 Hitesh Choudhary Chiradeep Gupta +3 位作者 Nirupama Tiwari Tanmay Kolge Rajeev Kapoor Archana Sharma 《Journal of Minerals and Materials Characterization and Engineering》 2020年第6期421-439,共19页
Electromagnetic forming is a high-speed forming technology by which hollow profiles can be compressed or expanded. It is done with a pulsed magnetic field to apply Lorentz’ forces at electrically conductive material.... Electromagnetic forming is a high-speed forming technology by which hollow profiles can be compressed or expanded. It is done with a pulsed magnetic field to apply Lorentz’ forces at electrically conductive material. Electromagnetic hollow tube expansion is limited by the fragmentation tendency. This work attempts to use a combination of analytical and computational approach to compute the net tangential stress during tube expansion. A simplified analytical framework to estimate the temporal evolution of plastic stresses present in aluminium alloy AA5052 at low and high applied magnetic pressures is developed based upon dynamic imaging. The time resolved images captured using current synchronised high speed camera record the overall dimensional changes of the tube that is validated by multi-physics simulation of expansion process. Imaging of hollow tube expansions at two selected peak currents has been carried out at various current levels in the range 76 - 160 kA. The direct visualisation of the increase in the tube diameter at two current levels provided a comparison of the developing net tangential stresses in the hollow tube during the undamaged and fragmented expansion. Imaging of tube expansion also facilitates the estimation of the strain rate experienced by the tube and was in the range of ~1700 s<sup>-1</sup> to ~1200 s<sup>-1</sup>. The propensity of fragmentation was found to be due to the level and duration of generated tangential stresses above the yield stress during expansion of the aluminium tubes. Presented study provides a mean of exploiting the enhanced formability of aluminium alloys using electromagnetic forming. 展开更多
关键词 electromagnetic Forming Aluminium Alloys High-Speed imaging
下载PDF
Intraoperative magnetic resonance imaging in neurosurgery and anesthetic considerations
12
作者 Nidhi Gupta Girija Prasad Rath 《World Journal of Anesthesiology》 2014年第2期174-180,共7页
Currently, magnetic resonance imaging(MRI) is the only imaging modality available which is capable of acquiring intra-operative images frequently with acceptable spatial and contrast resolution. However, the incorpora... Currently, magnetic resonance imaging(MRI) is the only imaging modality available which is capable of acquiring intra-operative images frequently with acceptable spatial and contrast resolution. However, the incorporation of MRI technology into the operating room requires special anesthetic considerations. It may include various aspects such as transport, remote location anesthesia, strong electromagnetic field, use of approved items, equipment counts, possible emergencies, and surgery in awake patients. The patient safety may be compromised by health-related, equipment-related, and procedure-related risks. Direct patient observation may be compromised by acoustic noise, darkened environment, obstructed line of sight, and distractions along with difficult access to the patient for airway management. Most often, the patient's head will be 180° away from the anesthesiologist during the procedure. Several monitors exist that are designed for conditional use in a MR environment. The general design criterion in these monitors is to eliminate conductors that carry electrical signals for monitoring physiologic parameters of the patient. General anesthesia requires an extended anesthetic circuit for ventilation maintenance and drug administration because the patient is located farther from the anesthesia machine than in traditional operating room settings. Dead space creates a time delay before the volatile anesthetic and drugs are administered and when expected effects can be observed. Therefore, the attending anaesthesiologists must understand the above aspects for safe conduct of neurosurgical procedures by minimizing MRI associated accidents while assuring optimal patient vigilance. 展开更多
关键词 INTRAOPERATIVE magnetic RESONANCE imaging electromagnetic field Safety ANESTHESIA NEUROSURGERY
下载PDF
Pixel for Passive Terahertz Imaging System (PTIS) at the Base of Josephson Junction in Self-Pumping Regime
13
作者 Alexander Denisov Sergey Denisov Qiu Jing Hui 《Journal of Physical Science and Application》 2013年第4期262-268,共7页
The use of Josephson junctions (JJ) in self-pumping mode as one of the heterodyne detection method can stay the new trend for design modern passive terahertz imaging system (PT1S). Combination superconductive and ... The use of Josephson junctions (JJ) in self-pumping mode as one of the heterodyne detection method can stay the new trend for design modern passive terahertz imaging system (PT1S). Combination superconductive and semiconductor technologies on the one substrate in any case will born principal trend of the critical electronic technologies, including the realization superconductive JJ near the gate of a semiconductor transistor. Further development will allow to realize the PTIS system with electronic tuning of the receiving frequency. At the same time there exists yet additional new possibility to measure the frequency of the receiving signals (very briefly) on JJ. 展开更多
关键词 Josephson junction image electromagnetic radiation terahertz band low noise receiver frequency.
下载PDF
Research on Influence of Electromagnetic Interference on X-Ray Digital Detection
14
作者 Guo Taotao Wang Dada +1 位作者 Guo Tieqiao Yu Hong 《Electricity》 2012年第5期38-43,共6页
X-ray digital imaging technology has found wide application owing to its advantages of real-time, visualization and rapid imaging. In substations the substantial electromagnetic interference has some influence on the ... X-ray digital imaging technology has found wide application owing to its advantages of real-time, visualization and rapid imaging. In substations the substantial electromagnetic interference has some influence on the live detection by the X-ray digital imaging technology, hindering the promotion of the technology in the detection of electric equipment. Based on a large number of field tests, the author carded out a series of researches on electromagnetic interference protection measures, image de-noising, and image enhancement algorithms. 展开更多
关键词 SUBSTATION live detection X-RAY digital imaging electromagnetic interference image de-noising image enhancement
下载PDF
微波视觉与SAR图像智能解译 被引量:2
15
作者 徐丰 金亚秋 《雷达学报(中英文)》 EI CSCD 北大核心 2024年第2期285-306,共22页
高分辨率雷达成像技术和人工智能、大数据技术的快速发展,有力促进了雷达图像智能解译技术的进步。由于雷达传感器本身的特殊性和电磁散射成像物理的复杂性,雷达图像的解译缺乏光学图像的直观性,准确迅速识别分类的需求对雷达图像解译... 高分辨率雷达成像技术和人工智能、大数据技术的快速发展,有力促进了雷达图像智能解译技术的进步。由于雷达传感器本身的特殊性和电磁散射成像物理的复杂性,雷达图像的解译缺乏光学图像的直观性,准确迅速识别分类的需求对雷达图像解译提出了迫切的挑战。在借鉴人脑光视觉感知机理和计算机视觉图像处理相关技术基础上,进一步融合电磁散射物理规律及其雷达成像机理,我们提出发展微波域雷达图像解译的“微波视觉”的新交叉领域研究。该文介绍微波视觉的概念与内涵,提出微波视觉认知模型,阐述其基础理论问题与技术路线,最后介绍了作者团队在相关问题上的初步研究进展。 展开更多
关键词 合成孔径雷达(SAR) 雷达成像 电磁散射 目标识别 微波视觉 语义电磁散射建模 物理智能 逆问题 视觉感知
下载PDF
3D影像配准联合AI电磁导航技术对前列腺穿刺活检的临床效果观察
16
作者 陈江川 张翾 +1 位作者 李昌龙 张家模 《重庆医科大学学报》 CAS CSCD 北大核心 2024年第6期694-700,共7页
目的:观察经会阴3D影像配准联合AI电磁导航下的mpMRI-TRUS影像融合活检在临床中的效果。方法:回顾性地分析选取2022年1月至2024年2月于重庆医科大学附属永川医院接受前列腺穿刺活检的患者178例作为研究对象,根据穿刺方法的不同分为经直... 目的:观察经会阴3D影像配准联合AI电磁导航下的mpMRI-TRUS影像融合活检在临床中的效果。方法:回顾性地分析选取2022年1月至2024年2月于重庆医科大学附属永川医院接受前列腺穿刺活检的患者178例作为研究对象,根据穿刺方法的不同分为经直肠认知组及经会阴AI组,比较2种穿刺方式对有临床意义的前列腺癌(clinically significant prostate cancer,csPCa)检出率和并发症的差异,使用多变量Cox分析确定csPCa检出率的影响因素。结果:94例患者和84例患者分别接受了经会阴AI融合和经直肠认知融合活检。在csPCa检测方面,经会阴AI融合活检优于经直肠认知融合活检(67.0%vs.53.5%,P=0.048)。在多变量回归分析中,年龄、PI-RADS评分>3和经会阴穿刺途径是csPCa的显著预测因素。经会阴活检的尿潴留率高于经直肠活检(18.5%vs.4.7%,P=0.009)。结论:AI导航融合活检的csPCa检出率比经直肠认知融合活检更优。此外,经会阴活检发生感染并发症的风险较小。 展开更多
关键词 前列腺穿刺 电磁导航 影像配准 mpMRI-TRUS
下载PDF
电磁超表面全息成像技术研究进展
17
作者 杨欢欢 张芷昀 +2 位作者 李桐 田江浩 曹祥玉 《空军工程大学学报》 CSCD 北大核心 2024年第2期1-13,共13页
超表面全息术的出现极大地促进了全息成像技术的发展,同时也拓展了电磁超表面的应用范围。为进一步梳理超表面全息成像的发展脉络,以技术发展的时间轴为主线,系统地回顾了超表面技术的发展历程,以及受益于超表面技术的全息成像模式的进... 超表面全息术的出现极大地促进了全息成像技术的发展,同时也拓展了电磁超表面的应用范围。为进一步梳理超表面全息成像的发展脉络,以技术发展的时间轴为主线,系统地回顾了超表面技术的发展历程,以及受益于超表面技术的全息成像模式的进步。随着技术的进步,超表面全息术逐渐从可见光频段向微波频段发展,从静态重现向动态全息演变,因此,着重介绍了超表面全息术的未来方向——可重构超表面及其动态全息技术,并且从超表面单元高性能创新技术、超表面阵列全息模式以及超表面全息系统研究3个方面对可重构超表面全息术的发展做了展望。 展开更多
关键词 电磁超表面 超材料 可重构技术 全息成像技术 振幅相位
下载PDF
基于扫描旋转同步运动的三维成像方法
18
作者 赵京城 娄长玉 +1 位作者 苗俊刚 轩师扬 《北京航空航天大学学报》 EI CAS CSCD 北大核心 2024年第3期796-802,共7页
为满足在役战机隐身性能的快速检测需求,提出了一种基于垂直扫描、方位旋转同步运动的三维成像方法。成像系统主要由射频收发设备、收发天线对、竖直方向导轨、转台和数据处理终端构成。天线发射频率步进信号时,对转台上的被测目标进行... 为满足在役战机隐身性能的快速检测需求,提出了一种基于垂直扫描、方位旋转同步运动的三维成像方法。成像系统主要由射频收发设备、收发天线对、竖直方向导轨、转台和数据处理终端构成。天线发射频率步进信号时,对转台上的被测目标进行水平旋转,同时,收发天线对在垂直方向上扫描被测目标。以点目标组合为例,通过理论分析和仿真计算,确定该成像系统的参数配置,比较不同参数配置下系统的三维成像性能。仿真结果表明:采用垂直扫描、方位旋转同步运动方法能够实现三维成像,该方法与经典圆柱面扫描方法相比,扫描时间可缩短92%,同时保持11 dB峰值旁瓣比率。所提方法具有测试效率高、系统搭建简单、易于调节的特点,为服役阶段的隐身飞机散射源诊断提供了一种有效的测量方法选择。 展开更多
关键词 隐身飞机 电磁散射测量 垂直扫描 方位旋转 三维成像
下载PDF
基于环形阵列的油管损伤三维成像检测方法研究
19
作者 罗有刚 桂捷 +3 位作者 富锐萍 胡相君 黄周启 王策 《现代电子技术》 北大核心 2024年第2期155-159,共5页
传统的瞬变电磁套管损伤检测技术是通过采集数据来反映套管损伤情况的二次场信息,反演套管二维壁厚曲线,为套管损伤提供解释依据。为了使套管损伤解释得更加高效、直观、精准,满足井口油管三维成像的需求,建立一种基于环形阵列式的井口... 传统的瞬变电磁套管损伤检测技术是通过采集数据来反映套管损伤情况的二次场信息,反演套管二维壁厚曲线,为套管损伤提供解释依据。为了使套管损伤解释得更加高效、直观、精准,满足井口油管三维成像的需求,建立一种基于环形阵列式的井口油管三维成像检测系统,利用探测仪器中环形阵列分布的TMR传感器,对井口油管各个方位的信息进行采集,使得采集到的数据能够描述不同深度、不同角度的损伤情况。结合套管半径、涡流扩散时间以及径向探测角度之间的关系,通过对井口三维数据的处理,实现套管内外壁三维成像,进而实现井口油管的非对称损伤解释。通过与传统的电磁探伤曲线的对比,验证了所提井口油管三维成像检测方法的有效性,为现场套管损伤解释工作提供重要依据。 展开更多
关键词 油管损伤 环形阵列 三维成像 瞬变电磁 TMR传感器 空间坐标转换
下载PDF
5.0T MRI临床应用价值与研究进展
20
作者 洪楠 《中国医学影像技术》 CSCD 北大核心 2024年第5期641-642,共2页
5.0T MR成像平台通过创新性设计解决了传统超高场强设备存在的图像信号不均匀、全身成像难等技术问题,使图像质量得以显著提高。目前5.0T MRI已在神经系统、心血管系统、骨骼肌肉系统及腹部成像中展现出巨大潜力,并已衍生出多种相关创... 5.0T MR成像平台通过创新性设计解决了传统超高场强设备存在的图像信号不均匀、全身成像难等技术问题,使图像质量得以显著提高。目前5.0T MRI已在神经系统、心血管系统、骨骼肌肉系统及腹部成像中展现出巨大潜力,并已衍生出多种相关创新性技术。本文就5.0T MRI的临床应用价值及其研究进展进行述评。 展开更多
关键词 电磁场 磁共振成像
下载PDF
上一页 1 2 34 下一页 到第
使用帮助 返回顶部