The Application of the Fault Current Limiters in Power Distribution System
1
作者 T. Madiba W. Siti A.A. Jimoh 《Journal of Energy and Power Engineering》 2011年第12期1205-1212,共8页
In this paper, an application of fault current limiter-thyristor controller series reactor (FCL-TCSR) in the distribution network is presented in order to minimize the peak value of current during the fault conditio... In this paper, an application of fault current limiter-thyristor controller series reactor (FCL-TCSR) in the distribution network is presented in order to minimize the peak value of current during the fault condition. This application considers a single fault current limiting action but can also be applied for a three phase system. The maximum contribution of FCL-TCSR quickly clears the abnormal current in the power distribution system when a fault condition occurs. Using a mathematical model of FCL-TCSR, the impact of series impedance used to adjust the amplitude of the fault current action is demonstrated. The performance of the load with the impedance and load in series is also analyzed. 展开更多
关键词 FCL-TCSR distribution network limhing action mathematical model amplitude of the abnormal current.
下载PDF
Pilot Protection Based on Amplitude Comparison for Renewable Power Teed Lines 被引量:1
2
作者 Ke Jia Zhe Yang +4 位作者 Yu Fang Zhengxuan Zhu Liming Zheng Tianshu Bi Ali Hooshyar 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第6期1519-1529,共11页
Fault behaviors of inverter-interfaced renewable energy generators(IIREGs)are quite diverse from those of synchronous generators(SGs).They show the variable system impedance,the limited current and low inertia,so the ... Fault behaviors of inverter-interfaced renewable energy generators(IIREGs)are quite diverse from those of synchronous generators(SGs).They show the variable system impedance,the limited current and low inertia,so the proportional brake differential protection installed on the transmission line has a high risk of failure for phase-phase failures.To cope with this adaptive problem,a new pilot protection is proposed considering the huge differences in both current amplitudes.Also,an improved criterion is presented for a scenario with a teed line.The existing protection principles focus excessively on the fault current characteristics of IIREGs,so they cannot operate correctly once IIREGs do not output their fault current.This happens when IIREGs produce no power or the circuit breakers exactly reclose on permanent failures.However,the proposed method has good performance for the above cases.The proposed method only requires current amplitude information,and in this case the strict synchronizing measurement is not necessary.Case studies are performed under different fault conditions,and they confirm the proposed method has good performance under different fault conditions.Furthermore,it is also verified using field-testing data. 展开更多
关键词 current amplitude inverter-interfaced renewable energy generators pilot protection teed line