期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Improved Control in Single Phase Inverter Grid-Tied PV System Using Modified PQ Theory
1
作者 Nur Fairuz Mohamed Yusof Dahaman Ishak +3 位作者 Muhammad Ammirrul Atiqi Mohd Zainuri Muhammad Najwan Hamidi Zuhair Muhammed Alaas Mohamed Mostafa Ramadan Ahmed 《Intelligent Automation & Soft Computing》 SCIE 2023年第8期2441-2457,共17页
Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast d... Grid-connected reactive-load compensation and harmonic control are becoming a central topic as photovoltaic(PV)grid-connected systems diversified.This research aims to produce a high-performance inverter with a fast dynamic response for accurate reference tracking and a low total har-monic distortion(THD)even under nonlinear load applications by improving its control scheme.The proposed system is expected to operate in both stand-alone mode and grid-connected mode.In stand-alone mode,the proposed controller supplies power to critical loads,alternatively during grid-connected mode provide excess energy to the utility.A modified variable step incremental conductance(VS-InCond)algorithm is designed to extract maximum power from PV.Whereas the proposed inverter controller is achieved by using a modified PQ theory with double-band hysteresis current controller(PQ-DBHCC)to produce a reference current based on a decomposition of a single-phase load current.The nonlinear rectifier loads often create significant distortion in the output voltage of single-phase inverters,due to excessive current harmonics in the grid.Therefore,the proposed method generates a close-loop reference current for the switching scheme,hence,minimizing the inverter voltage distortion caused by the excessive grid current harmonics.The simulation findings suggest the proposed control technique can effectively yield more than 97%of power conversion efficiency while suppressing the grid current THD by less than 2%and maintaining the unity power factor at the grid side.The efficacy of the proposed controller is simulated using MATLAB/Simulink. 展开更多
关键词 hysteresis current controller incremental conductance nonlinear load PQ theory single-phase inverter
下载PDF
Optimized Power Factor Correction for High Speed Switched Reluctance Motor
2
作者 R.S.Preethishri J.Anitha Roseline +1 位作者 K.Murugesan M.Senthil Kumaran 《Intelligent Automation & Soft Computing》 SCIE 2023年第1期997-1014,共18页
The Power Factor Correction(PFC)in Switched Reluctance(SR)motor is discussed in this article.The SR motors are applicable for multiple applications like electric vehicles,wind mills,machineries etc.The doubly salient ... The Power Factor Correction(PFC)in Switched Reluctance(SR)motor is discussed in this article.The SR motors are applicable for multiple applications like electric vehicles,wind mills,machineries etc.The doubly salient structure of SR motor causes the occurrence of torque ripples,which affects the power factor of the motor.To improve the power quality,the power factor has to be corrected and the ripples have to be minimized.In order to achieve these objectives,a novel power factor correction(PFC)method is proposed in this work.Here,the conventional Diode Bridge Rectifier(DBR)is replaced by a Bridgeless Hybrid Resonant(HR)converter,which assists in improvising the output in a wider range.The converter is chosen because of having variety of beneficial measures including high gain.The converter’s output is fed to the SR motor by means of an asymmetric Bridge Resonant(BR)converter.The proposed converter operates in continuous mode of conduction with the switching frequency of 10 KHz.A hysteresis current controller and Proportional Integral(PI)controller are utilized for reducing the harmonics in the source current along with the regulation of output voltage.In addition,the speed control of SR motor is accomplished by means of the Whale Optimization Algorithm(WOA)assisted PI controller.The proposed methodology is effective for the control of unity power factor,torque and current ripples.The Total Harmonic Distortion(THD)of the source current is also minimized,which suits the standard of International Electrotechnical Comission IEC 61000-3-2.By this methodology,the power factor of 0.99 is achieved with 97%efficiency and 3.92%THD.The proposed methodology is validated in simulation by MATLAB and in hardware by FPGA Spartan 6E. 展开更多
关键词 Bridgeless hybrid resonant converter switched reluctance motor BR converter hysteresis current controller PI controller WOA
下载PDF
An Improvement in Power Quality and By-Product of the Run-Off River Micro Hydro Power Plant
3
作者 Ignatius Riyadi Mardiyanto Jangkung Raharjo +2 位作者 Sri Utami Wahyu Budi Mursanto Agoeng Hardjatmo Rahardjo 《Energy Engineering》 EI 2023年第6期1295-1305,共11页
Utilization of Micro Hydro Power Plant at the Gunung Halu case study type run-off the river is a household use only in the afternoon,around 5 pm until bedtime at about 10 pm.Therefore,more than 75%of the energy is los... Utilization of Micro Hydro Power Plant at the Gunung Halu case study type run-off the river is a household use only in the afternoon,around 5 pm until bedtime at about 10 pm.Therefore,more than 75%of the energy is lost.This case study lost power which can be used as a by-product,such as for drying coffee beans.In this case study,a design was carried out to obtain by-products and improve power quality in the electrical system.In addition,they complain about the poor quality of power controlled by frequency using Triac-Based Electronic Dummy Load Control.The heat from the dummy load in the case study is used as a by-product.MHP with a minimum power of 20 kW,and the usage time of customer service is about 6 h.The energy for the by-products is about 360 kWh/day,and the power quality improved by using Triac-Based Electronic Load Control and Hysteresis Current Control for the active filter.As a result,the power factor is close to one,the generator current harmonics is less than 2%,and the voltage harmonics is less than 5%. 展开更多
关键词 Electronics load controller triac-based hysteresis current control power quality micro-hydro power
下载PDF
Digital fixed-frequency hysteresis current control of a BLDC motor applied for aerospace electrically powered actuators 被引量:3
4
作者 Jian FU Yongling FU +3 位作者 Liming YU Jianwen GUO Rongrong YANG Mingkang WANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2018年第6期1287-1297,共11页
In the conventional cascade control structure of aerospace electrically powered actuators, the current(or electromagnetic torque) loop plays a critical role in realizing a rapid response for a digitally controlled B... In the conventional cascade control structure of aerospace electrically powered actuators, the current(or electromagnetic torque) loop plays a critical role in realizing a rapid response for a digitally controlled Brush Less Direct Current(BLDC) motor. Hysteresis Current Control(HCC) is an effective method in improving the performance of current control for a BLDC motor.Nevertheless, the varying modulating frequency in the traditional HCC causes severe problems on the safety of power devices and the electromagnetic compatibility design. A triangular carrier-based fixed-frequency HCC strategy is expanded by relaxing the constraints on the rising and descending rates of the winding current to advance the capability of HCC to realize fixed-frequency modulation in the steady state. Based on that, a new flexible-bound-size quasi-fixed-frequency HCC is proposed, and the range feasible to realize fixed-frequency modulation control can cover the entire running process in the steady state. Meanwhile, a corresponding digital control strategy is designed,and four digitalization rules are proposed to extend the capacity to achieve fixed-frequency modulation control to the unsteady working state, that is, a novel fixed-frequency modulation is realized.Simulation and experimental results prove the effectiveness of this improved fixed-frequency HCC strategy. 展开更多
关键词 BLDC motor current control Fixed-frequency modulation Flexible bound size hysteresis current control PWM Triangular carrier
原文传递
Design of DSTATCOM Controller for Compensating Unbalances 被引量:1
5
作者 Murugesan Kullan Ranganath Muthu +1 位作者 Jebamalai Benny Mervin Vijayenthiran Subramanian 《Circuits and Systems》 2016年第9期2362-2372,共11页
In a three phase power system, the voltages at the generation side are in sinusoidal and equal in magnitude with 120? phase difference between the phases. However, at the load side voltages may become unbalanced due t... In a three phase power system, the voltages at the generation side are in sinusoidal and equal in magnitude with 120? phase difference between the phases. However, at the load side voltages may become unbalanced due to unequal voltage magnitudes at the fundamental frequency, phase angle deviations or unequal distribution of single phase loads. The voltage unbalance is a major power quality issue, because a small unbalance in the phase voltages can cause a larger unbalance in the phase currents. A completely balanced three-phase three wire system contains only positive sequence components of voltage, current and impedance, whereas unbalanced system contains both positive and negative sequence components of voltages and currents. The negative sequence component of current in the unbalanced system increases the temperature and losses in the equipments. Hence, it is necessary to mitigate this problem by supplying the negative sequence current to the load at the load side and keep the source side balanced. This paper proposes the shunt connected, current injecting Distribution Static Synchronous Compensator (DSTATCOM) with appropriate controller to mitigate the unbalanced load current. The symmetrical components based Hysteresis Current Controller (HCC) is designed for DSTATCOM to diminish the unbalances in a three-phase three-wire system. The performance of the controller is studied by simulating the entire system in the MATLAB/Simulink environment. The DSTATCOM with HCC is found to be better than other controllers because it is suitable for compensating both balanced and unbalanced loads. 展开更多
关键词 COMPENSATION DSTATCOM hysteresis current Controller Symmetrical Components Unbalanced Systems Negative Sequence current
下载PDF
Effect of Ball Scribing on Power Loss Separation of Fe-3%Si Grain-oriented Silicon Steel
6
作者 王浩 李长生 +4 位作者 ZHAN Jianbo YU Zhenhua JI Yafeng WANG Guanglei PERIN Deniz 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2016年第2期435-439,共5页
Power loss of Fe-3%Sigrain-oriented silicon steelwas measured after ballscribing with different spacing using a self-designed tool.Three different sections of power loss,including hysteresis loss,abnormalloss,and eddy... Power loss of Fe-3%Sigrain-oriented silicon steelwas measured after ballscribing with different spacing using a self-designed tool.Three different sections of power loss,including hysteresis loss,abnormalloss,and eddy current loss,were measured and calculated,respectively.The loss variation and ratio were analyzed based on the experimentaldata.At 1.0 T,hysteresis loss of tested steelwith scribing spacing of 8 mm descends by 8.2% compared to samples without scribing,which is similar to the totalloss variation,and abnormalloss descends by 16.8%.At 1.0 T,hysteresis loss ratio of the steelwith scribing spacing of 16 mm ascends from 55.7% to 57.9%,and eddy current loss increases from 17.4% to 24.1%,while abnormalloss descends from 26.9% to 23.7%.The experimentalresults show that the reduction of power loss after scribing is mainly due to decreasing of hysteresis loss and abnormalloss. 展开更多
关键词 Fe-3%Si grain-oriented silicon steel ball scribing hysteresis loss eddy current loss abnormal loss
下载PDF
An Efficient Particle Swarm Optimization Technique for 4-Leg Shunt Active Power Filter
7
作者 V. Parimala S. Chenthur Pandian D. Ganeshkumar 《Circuits and Systems》 2016年第8期1546-1559,共14页
This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Opt... This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment. 展开更多
关键词 hysteresis current Controller Particle Swarm Optimization Shunt Active Power Filter SRF Method
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部