A novel structure for a charge pump circuit is proposed, in which the charge-pump (CP) current can adaptively regulated according to phase-locked loops (PLL) frequency synthesis demand. The current follow technolo...A novel structure for a charge pump circuit is proposed, in which the charge-pump (CP) current can adaptively regulated according to phase-locked loops (PLL) frequency synthesis demand. The current follow technology is used to make perfect current matching characteristics, and the two differential inverters are implanted to increase the speed of charge pump and decrease output spur due to theory of low voltage difference signal. Simulation results, with 1st silicon 0. 25μm 2. 5 V complementary metal-oxide-semiconductor (CMOS) mixed-signal process, show the good current matching characteristics regardless of the charge pump output voltages.展开更多
A new bipolar temperature-compensated current reference is proposed. The first-order temperature compensation is achieved by the idea of self temperature-compensation configuration exploiting the temperature coefficie...A new bipolar temperature-compensated current reference is proposed. The first-order temperature compensation is achieved by the idea of self temperature-compensation configuration exploiting the temperature coefficient of a combined resistor. The second-order compensation employs a VBE-tracking thermal-startup technique to obtain improved temperature performance. The proposed circuit can operate down to a 1-V supply. A temperature coefficient of 46.6×10?6/℃ [0, 100℃] at a 1-V supply and a supply regulation of 0.036%/V at 25℃ are achieved. Compared with present works, the proposed circuit shows better results of the temperature coefficient and supply regulation. The current matching issue frequently encountered in current references is also discussed in detail.展开更多
Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occu...Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occurred. Based on dictionary of Gabor atoms and matching pursuit algorithm, the method extracts the atomic components iteratively from the feature signals and translated them to damped sinusoidal components. Then we can obtain the parametrical and analytical representation of atomic components. The termination condition of decomposing iteration is determined by the threshold of the initial residual energy with the purpose of extract the features more effectively. Accordingly, the proposed method can extract the starting and ending moment of disturbances precisely as well as their magnitudes, frequencies and other features. The numerical examples demonstrate its effectiveness.展开更多
文摘A novel structure for a charge pump circuit is proposed, in which the charge-pump (CP) current can adaptively regulated according to phase-locked loops (PLL) frequency synthesis demand. The current follow technology is used to make perfect current matching characteristics, and the two differential inverters are implanted to increase the speed of charge pump and decrease output spur due to theory of low voltage difference signal. Simulation results, with 1st silicon 0. 25μm 2. 5 V complementary metal-oxide-semiconductor (CMOS) mixed-signal process, show the good current matching characteristics regardless of the charge pump output voltages.
文摘A new bipolar temperature-compensated current reference is proposed. The first-order temperature compensation is achieved by the idea of self temperature-compensation configuration exploiting the temperature coefficient of a combined resistor. The second-order compensation employs a VBE-tracking thermal-startup technique to obtain improved temperature performance. The proposed circuit can operate down to a 1-V supply. A temperature coefficient of 46.6×10?6/℃ [0, 100℃] at a 1-V supply and a supply regulation of 0.036%/V at 25℃ are achieved. Compared with present works, the proposed circuit shows better results of the temperature coefficient and supply regulation. The current matching issue frequently encountered in current references is also discussed in detail.
文摘Applying the atomic sparse decomposition in the distribution network with harmonics and small current grounding to decompose the transient zero sequence current that appears after the single phase to ground fault occurred. Based on dictionary of Gabor atoms and matching pursuit algorithm, the method extracts the atomic components iteratively from the feature signals and translated them to damped sinusoidal components. Then we can obtain the parametrical and analytical representation of atomic components. The termination condition of decomposing iteration is determined by the threshold of the initial residual energy with the purpose of extract the features more effectively. Accordingly, the proposed method can extract the starting and ending moment of disturbances precisely as well as their magnitudes, frequencies and other features. The numerical examples demonstrate its effectiveness.