A versatile current-mode biquadratic filter using three operational amplifiers and nine passive elements is proposed. By suitably choosing the output branch, lowpass, bandpass, highpass, bandstop and allpass transfer ...A versatile current-mode biquadratic filter using three operational amplifiers and nine passive elements is proposed. By suitably choosing the output branch, lowpass, bandpass, highpass, bandstop and allpass transfer functions are realized simultaneously without changing the circuit configuration and elements. Two circuits, one is for low frequency application and the other for high frequency, are proposed. The center frequency, quality factor and gain constants of the circuit can be tuned independently. Simulated results show that the circuits work successfully.展开更多
The design method for a low-cost toroidal inductor is proposed as an alternative to power-quality evaluation. The method is based on well-known tools by the engineers in which is presented the relationships that exist...The design method for a low-cost toroidal inductor is proposed as an alternative to power-quality evaluation. The method is based on well-known tools by the engineers in which is presented the relationships that exist between equivalent circuit and transfer function of a toroidal inductor. The proposed design method has been explained with normalized functions based on physical parameters of a toroidal inductor. This work presents the main arguments of the suggested methodology and as demonstration of the design method as function of normalized parameters, is developed a current-signal sensor which has been validated in the laboratory by the EN-50160-2-2 standard to evaluate the power quality in home use loads.展开更多
For the last several years, the linear array x-ray detector for x-ray imaging with gallium arsenide direct conversion sensitive elements has been developed and tested at the In-stitute for High Energy Physics. The arr...For the last several years, the linear array x-ray detector for x-ray imaging with gallium arsenide direct conversion sensitive elements has been developed and tested at the In-stitute for High Energy Physics. The array consists of 16 sensitive modules. Each module has 128 gallium arsenide (GaAs) sensitive elements with 200 μm pitch. Current article describes two key program procedures of initial dark current compensation of each sensitive element in the linear array, and sensitivity adjustment for alignment of strip pattern in the raw image data. As a part of evaluation process a modular transfer function (MTF) was measured with the slanted sharp-edge object under RQA5 technique as it described in the International Electrotechnical Commission 62220-1 standard (high voltage 70 kVp, additional aluminium filter 21 mm) for images with compensated dark currents and adjusted sensitivity of detector elements. The 10% level of the calculated MTF function has spatial resolution within 2 - 3 pair of lines per mm for both vertical and horizontal orientation.展开更多
建立反射式光纤电流互感器R-FOCT(Reflecting Fiber-optic Current Transducer)的数学模型,得到描写模型的差分方程,推导出与之对应的传递函数,仿真系统的频率特性。根据电流传感器的工作特点,提出应用锁定放大器SR830测试R-FOCT频率特...建立反射式光纤电流互感器R-FOCT(Reflecting Fiber-optic Current Transducer)的数学模型,得到描写模型的差分方程,推导出与之对应的传递函数,仿真系统的频率特性。根据电流传感器的工作特点,提出应用锁定放大器SR830测试R-FOCT频率特性的方法。比较测试数据和仿真结果,结果表明,系统的带宽计算和测量方法是可信的,得到了系统带宽大于6kHz的结论。展开更多
文摘A versatile current-mode biquadratic filter using three operational amplifiers and nine passive elements is proposed. By suitably choosing the output branch, lowpass, bandpass, highpass, bandstop and allpass transfer functions are realized simultaneously without changing the circuit configuration and elements. Two circuits, one is for low frequency application and the other for high frequency, are proposed. The center frequency, quality factor and gain constants of the circuit can be tuned independently. Simulated results show that the circuits work successfully.
文摘The design method for a low-cost toroidal inductor is proposed as an alternative to power-quality evaluation. The method is based on well-known tools by the engineers in which is presented the relationships that exist between equivalent circuit and transfer function of a toroidal inductor. The proposed design method has been explained with normalized functions based on physical parameters of a toroidal inductor. This work presents the main arguments of the suggested methodology and as demonstration of the design method as function of normalized parameters, is developed a current-signal sensor which has been validated in the laboratory by the EN-50160-2-2 standard to evaluate the power quality in home use loads.
文摘For the last several years, the linear array x-ray detector for x-ray imaging with gallium arsenide direct conversion sensitive elements has been developed and tested at the In-stitute for High Energy Physics. The array consists of 16 sensitive modules. Each module has 128 gallium arsenide (GaAs) sensitive elements with 200 μm pitch. Current article describes two key program procedures of initial dark current compensation of each sensitive element in the linear array, and sensitivity adjustment for alignment of strip pattern in the raw image data. As a part of evaluation process a modular transfer function (MTF) was measured with the slanted sharp-edge object under RQA5 technique as it described in the International Electrotechnical Commission 62220-1 standard (high voltage 70 kVp, additional aluminium filter 21 mm) for images with compensated dark currents and adjusted sensitivity of detector elements. The 10% level of the calculated MTF function has spatial resolution within 2 - 3 pair of lines per mm for both vertical and horizontal orientation.
文摘建立反射式光纤电流互感器R-FOCT(Reflecting Fiber-optic Current Transducer)的数学模型,得到描写模型的差分方程,推导出与之对应的传递函数,仿真系统的频率特性。根据电流传感器的工作特点,提出应用锁定放大器SR830测试R-FOCT频率特性的方法。比较测试数据和仿真结果,结果表明,系统的带宽计算和测量方法是可信的,得到了系统带宽大于6kHz的结论。