Objective This study attempted to seek a new Doppler-derived index for estimating ventricularsystolic function. Methods With custom - made software the aortic and pulmonic flow profiles were digitized andconverted to ...Objective This study attempted to seek a new Doppler-derived index for estimating ventricularsystolic function. Methods With custom - made software the aortic and pulmonic flow profiles were digitized andconverted to their 4V2 curves, their maximum value of the first derivative, max (dk/dt) were obtained separately in23 and 25patients with congenital heart disease (mean age 4.5 years). Aortic max(dk/dt) and pulmonic max(dk/dt)measured by Doppler were compared with left ventricular max(dp/dt) and right ventricular max(dp/dt) measuredby cardiac catheterization. Results Aortic max(dk/dt) correlated well with LV max(dp/dt) (r=0.817, P<0.001).An excellent correlation of pulmonic max(dk/dt) with RV max(dp/dt) was established (r=0.926, P<0.0001). Therewas a significant correlation between RVSP and RV max(dp/dt) (r= 0.839, P<0.0001). Conclusion Doppler - derived aortic max(dk/dt) and pulmonic max(dk/dt) could be reliable index of left ventricular contractility and rightventricular contractility respectively. When max(dp/dt) is used for assessing RV systolic function, the impact ofRVSP on that should be taken into consideration.展开更多
文摘Objective This study attempted to seek a new Doppler-derived index for estimating ventricularsystolic function. Methods With custom - made software the aortic and pulmonic flow profiles were digitized andconverted to their 4V2 curves, their maximum value of the first derivative, max (dk/dt) were obtained separately in23 and 25patients with congenital heart disease (mean age 4.5 years). Aortic max(dk/dt) and pulmonic max(dk/dt)measured by Doppler were compared with left ventricular max(dp/dt) and right ventricular max(dp/dt) measuredby cardiac catheterization. Results Aortic max(dk/dt) correlated well with LV max(dp/dt) (r=0.817, P<0.001).An excellent correlation of pulmonic max(dk/dt) with RV max(dp/dt) was established (r=0.926, P<0.0001). Therewas a significant correlation between RVSP and RV max(dp/dt) (r= 0.839, P<0.0001). Conclusion Doppler - derived aortic max(dk/dt) and pulmonic max(dk/dt) could be reliable index of left ventricular contractility and rightventricular contractility respectively. When max(dp/dt) is used for assessing RV systolic function, the impact ofRVSP on that should be taken into consideration.