期刊文献+
共找到9,596篇文章
< 1 2 250 >
每页显示 20 50 100
Development of a Drilling and Coring Test-bed for Lunar Subsurface Exploration and Preliminary Experiments 被引量:11
1
作者 SHI Xiaomeng DENG Zongquan +3 位作者 QUAN Qiquan TANG Dewei HOU Xuyan JIANG Shengyuan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第4期673-682,共10页
Drill sampling has been widely employed as an effective way to acquire deep samples in extraterrestrial exploration. A novel sampling method, namely, flexible-tube coring, was adopted for the Chang'e mission to acqui... Drill sampling has been widely employed as an effective way to acquire deep samples in extraterrestrial exploration. A novel sampling method, namely, flexible-tube coring, was adopted for the Chang'e mission to acquire drilling cores without damaging stratification information. Since the extraterrestrial environment is uncertain and different from the terrestrial environment, automated drill sampling missions are at risk of failure. The principles of drilling and coring for the lunar subsurface should be fully tested and verified on earth before launch. This paper proposes a test-bed for conducting the aforementioned experiments on earth. The test-bed comprises a rotary-percussive drilling mechanism, penetrating mechanism, drilling medium container, and signal acquisition and control system. For granular soil, coring experiments indicate that the sampling method has a high coring rate greater than 80%. For hard rock, drilling experiments indicate that the percussive frequency greatly affects the drilling efficiency. A multi-layered simulant composed of granular soil and hard rock is built to test the adaptability of drilling and coring. To tackle complex drilling media, an intelligent drilling strategy based on online recognition is proposed to improve the adaptability of the sampling drill. The primary features of this research are the proposal of a scheme for drilling and coring a test-bed for validation on earth and the execution of drilling experiments in complex media. 展开更多
关键词 drilling and coring device test-bed lunar soil sampling
下载PDF
Design and Test of the Semi-Automatic Test-Bed with Inclined Belt of Garlic Transplanting Machine 被引量:2
2
作者 Zhaolei Zhang Aijun Geng +2 位作者 Jianning Yang Ruxin Li Jialin Hou 《American Journal of Plant Sciences》 2015年第19期3298-3305,共8页
In order to verify the feasibility of semi-automatic garlic planter with inclined belt program and determine its reasonable operating parameters, the semi-automatic test-bed with inclined belt of garlic transplanting ... In order to verify the feasibility of semi-automatic garlic planter with inclined belt program and determine its reasonable operating parameters, the semi-automatic test-bed with inclined belt of garlic transplanting machine was designed, and the garlic box experiments were conducted. The angle of inclined belt on the test-bed and its running speed were adjustable. Single factor test results showed that the program of the semi-automatic garlic planter with inclined belt was feasible, and the angle of inclined belt and the test bed running speed affected the indicators. Orthogonal experiment results showed that the angle of inclined belt was the main factor affecting the test indicators. It is also found that the best angle was 30 degrees, while the most reasonable running speed was 0.75 Km/h. 展开更多
关键词 GARLIC PLANTER Inclined BELT test-bed
下载PDF
Simplified Removable Ground Test-Bed for Testing Turbofan Engine
3
作者 李文峰 王永生 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2003年第3期138-141,共4页
A new simplified removable ground test-bed was designed for testing a certainturbofan engine. The facilities are 5.5 m long, 1.5 m wide, 2.2 m high and not more than 4. 5 t ofits empty weight. There are four rubber wh... A new simplified removable ground test-bed was designed for testing a certainturbofan engine. The facilities are 5.5 m long, 1.5 m wide, 2.2 m high and not more than 4. 5 t ofits empty weight. There are four rubber wheels that could be towed. There is an independentelectrical measurement and control system to test the rotational speed of rotors, the gas pressureof the compressor, the exhaust gas temperature, etc. Cooperated with the oil truck and the electricpower supply truck, the turbofan engine could be preserved on the ground and started to the idlingregime. While running, the parameter of the engine could be recorded, disposed and displayed. Inaddition, the facilities were successfully applied to the plateau experiment in order to researchhow the atmosphere pressure affects the start of engines. Some data are given in the paper. 展开更多
关键词 turbofan engine simplified type REMOVABLE test-bed ground test facilities
下载PDF
基于Damper的方向盘抖动问题优化设计
4
作者 葛峰 高中扩 +1 位作者 钱勇 王小飞 《汽车维修技师》 2024年第18期115-115,共1页
方向盘是顾客使用频次较高的零部件,受发动机等振源影响,在某些工况下方向盘会出现抖动等让顾客感到不适的问题,本文浅析了某车型方向盘高速抖动的原因,在现有方向盘结构上优化设计,增加Damper吸振器,有效解决了方向盘抖动问题,提升了... 方向盘是顾客使用频次较高的零部件,受发动机等振源影响,在某些工况下方向盘会出现抖动等让顾客感到不适的问题,本文浅析了某车型方向盘高速抖动的原因,在现有方向盘结构上优化设计,增加Damper吸振器,有效解决了方向盘抖动问题,提升了顾客舒适性。 展开更多
关键词 方向盘 抖动 damper吸振器 舒适性
下载PDF
Seismic control of multi-degrees-of-freedom structures by vertical mass isolation method using MR dampers
5
作者 Mohamad Shahrokh Abdi Masoud Nekooei Mohammad-Ali Jafari 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期503-510,共8页
Vertical mass isolation(VMI)is one of the novel methods for the seismic control of structures.In this method,the entire structure is assumed to consist of two mass and stiffness subsystems,and an isolated layer is loc... Vertical mass isolation(VMI)is one of the novel methods for the seismic control of structures.In this method,the entire structure is assumed to consist of two mass and stiffness subsystems,and an isolated layer is located among them.In this study,the magnetorheological damper in three modes:passive-off,passive-on,and semi-active mode with variable voltage between zero and 9 volts was used as an isolated layer between two subsystems.Multi-degrees-of-freedom structures with 5,10,and 15 floors in two dimensions were examined under 11 pairs of near field earthquakes.On each level,the displacement of MR dampers was taken into account.The responses of maximum displacement,maximum inter-story drift,and maximum base shear in controlled and uncontrolled buildings were compared to assess the suggested approach for seismic control of the structures.According to the results,the semi-active control method can reduce the response by more than 12%compared to the uncontrolled mode in terms of maximum displacement of the mass subsystem of the structures.This method can reduce more than 16%and 20%of the responses compared to the uncontrolled mode in terms of maximum inter-story drift and base shear of the structure,respectively. 展开更多
关键词 seismic control vertical mass isolation base shear magnetorheological damper semi-active control
下载PDF
Theoretical and Experimental Study on the Performance of Hermetic Diaphragm Squeeze Film Dampers for Gas-Lubricated Bearings
6
作者 Jianwei Wang Haoxi Zhang +3 位作者 Shaocun Han Hang Li Peng Wang Kai Feng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2024年第3期151-169,共19页
Low damping characteristics have always been a key sticking points in the development of gas bearings.The application of squeeze film dampers can significantly improve the damping performance of gas lubricated bearing... Low damping characteristics have always been a key sticking points in the development of gas bearings.The application of squeeze film dampers can significantly improve the damping performance of gas lubricated bearings.This paper proposed a novel hermetic diaphragm squeeze film damper(HDSFD)for oil-free turbomachinery supported by gas lubricated bearings.Several types of HDSFDs with symmetrical structure were proposed for good damping performance.By considering the compressibility of the damper fluid,based on hydraulic fluid mechanics theory,a dynamic model of HDSFDs under medium is proposed,which successfully reflects the frequency dependence of force coefficients.Based on the dynamic model,the effects of damper fluid viscosity,bulk modulus of damper fluid,thickness of damper fluid film and plunger thickness on the dynamic stiffness and damping of HDSFDs were analyzed.An experimental test rig was assembled and series of experimental studies on HDSFDs were conducted.The damper fluid transverse flow is added to the existing HDSFD concept,which aims to make the dynamic force coefficients independent of frequency.Although the force coefficient is still frequency dependent,the damping coefficient at high frequency excitation with damper fluid supply twice as that without damper fluid supply.The results serve as a benchmark for the calibration of analytical tools under development. 展开更多
关键词 Hermetic diaphragm squeeze film damper COMPRESSIBILITY Dynamic model Experimental studies
下载PDF
Vibration attenuation performance of wind turbine tower using a prestressed tuned mass damper under seismic excitation
7
作者 Lei Zhenbo Liu Gang +1 位作者 Wang Hui Hui Yi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期511-524,共14页
With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cau... With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cause excessive vibration of the WTT.To investigate the vibration attenuation performance of the WTT under seismic excitations,a novel passive vibration control device,called a prestressed tuned mass damper(PS-TMD),is presented in this study.First,a mathematical model is established based on structural dynamics under seismic excitation.Then,the mathematical analytical expression of the dynamic coefficient is deduced,and the parameter design method is obtained by system tuning optimization.Next,based on a theoretical analysis and parameter design,the numerical results showed that the PS-TMD was able to effectively mitigate the resonance under the harmonic basal acceleration.Finally,the time-history analysis method is used to verify the effectiveness of the traditional pendulum tuned mass damper(PTMD)and the novel PS-TMD device,and the results indicate that the vibration attenuation performance of the PS-TMD is better than the PTMD.In addition,the PS-TMD avoids the nonlinear effect due to the large oscillation angle,and has the potential to dissipate hysteretic energy under seismic excitation. 展开更多
关键词 wind turbine tower prestressed tuned mass damper vibration control seismic excitation numerical simulation
下载PDF
Development and Application of a Power Law Constitutive Model for Eddy Current Dampers
8
作者 Longteng Liang Zhouquan Feng +2 位作者 Hongyi Zhang Zhengqing Chen Changzhao Qian 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2403-2419,共17页
Eddy current dampers (ECDs) have emerged as highly desirable solutions for vibration control due to theirexceptional damping performance and durability. However, the existing constitutive models present challenges tot... Eddy current dampers (ECDs) have emerged as highly desirable solutions for vibration control due to theirexceptional damping performance and durability. However, the existing constitutive models present challenges tothe widespread implementation of ECD technology, and there is limited availability of finite element analysis (FEA)software capable of accurately modeling the behavior of ECDs. This study addresses these issues by developing anewconstitutivemodel that is both easily understandable and user-friendly for FEAsoftware. By utilizing numericalresults obtained from electromagnetic FEA, a novel power law constitutive model is proposed to capture thenonlinear behavior of ECDs. The effectiveness of the power law constitutive model is validated throughmechanicalproperty tests and numerical seismic analysis. Furthermore, a detailed description of the application process ofthe power law constitutive model in ANSYS FEA software is provided. To facilitate the preliminary design ofECDs, an analytical derivation of energy dissipation and parameter optimization for ECDs under harmonicmotionis performed. The results demonstrate that the power law constitutive model serves as a viable alternative forconducting dynamic analysis using FEA and optimizing parameters for ECDs. 展开更多
关键词 Eddy current damper constitutive model finite element analysis vibration control power law constitutive model
下载PDF
Parameters Optimization and Performance Evaluation of the Tuned Inerter Damper for the Seismic Protection of Adjacent Building Structures
9
作者 Xiaofang Kang Jian Wu +1 位作者 Xinqi Wang Shancheng Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期551-593,共43页
In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in ... In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in serial or in parallel.The dynamic equations of TID adjacent building damping systems were derived,and the H2 norm criterion was used to optimize and adjust them,so that the system had the optimum damping performance under white noise random excitation.Taking TID frequency ratio and damping ratio as optimization parameters,the optimum analytical solutions of the displacement frequency response of the undamped structure under white noise excitation were obtained.The results showed that compared with the classic TMD,TID could obtain a better damping effect in the adjacent buildings.Comparing the TIDs composed of serial or parallel,it was found that the parallel TIDs had more significant advantages in controlling the peak displacement frequency response,while the H2 norm of the displacement frequency response of the damping system under the coupling of serial TID was smaller.Taking the adjacent building composed of two ten-story frame structures as an example,the displacement and energy collection time history analysis of the adjacent building coupled with the optimum design parameter TIDs were carried out.It was found that TID had a better damping effect in the full-time range compared with the classic TMD.This paper also studied the potential power of TID in adjacent buildings,which can be converted into available power resources during earthquakes. 展开更多
关键词 Adjacent buildings tuned inerter damper(TID) H2 norm optimization vibration control energy harvesting
下载PDF
Parameter Optimization of Tuned Mass Damper Inerter via Adaptive Harmony Search
10
作者 Yaren Aydın Gebrail Bekdas +1 位作者 Sinan Melih Nigdeli Zong Woo Geem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第12期2471-2499,共29页
Dynamic impacts such as wind and earthquakes cause loss of life and economic damage.To ensure safety against these effects,various measures have been taken from past to present and solutions have been developed using ... Dynamic impacts such as wind and earthquakes cause loss of life and economic damage.To ensure safety against these effects,various measures have been taken from past to present and solutions have been developed using different technologies.Tall buildings are more susceptible to vibrations such as wind and earthquakes.Therefore,vibration control has become an important issue in civil engineering.This study optimizes tuned mass damper inerter(TMDI)using far-fault ground motion records.This study derives the optimum parameters of TMDI using the Adaptive Harmony Search algorithm.Structure displacement and total acceleration against earthquake load are analyzed to assess the performance of the TMDI system.The effect of the inerter when connected to different floors is observed,and the results are compared to the conventional tuned mass damper(TMD).It is indicated that the case of connecting the inerter force to the 5th floor gives better results.As a result,TMD and TMDI systems reduce the displacement by 21.87%and 25.45%,respectively,and the total acceleration by 25.45%and 19.59%,respectively.These percentage reductions indicated that the structure resilience against dynamic loads can be increased using control systems. 展开更多
关键词 Passive control optimum design parameter optimization tuned mass damper inerter time domain adaptive harmony search algorithm
下载PDF
Seismic Resilience Analysis of a Concrete-Framed Hospital Building with Viscous Dampers
11
作者 Yinghui Li Dongya An 《Journal of Architectural Research and Development》 2024年第6期58-62,共5页
To study the seismic resilience of a concrete-framed hospital building with viscous dampers,the elastoplastic time history analysis of a three-story concrete-framed hospital building under moderate and rare earthquake... To study the seismic resilience of a concrete-framed hospital building with viscous dampers,the elastoplastic time history analysis of a three-story concrete-framed hospital building under moderate and rare earthquakes was carried out by finite element analysis software.The structure’s overall response was studied,meanwhile,the seismic resilience of the building was evaluated from three aspects:repair cost,repair time,and casualties.The results show that viscous dampers can effectively reduce the repair cost,repair time,and casualties under earthquakes.Compared with the structure without dampers,the repair cost and repair time of the structure with dampers have been reduced by 67%and 69%respectively under moderate earthquakes,42%and 39%respectively under rare earthquakes,and the seismic resilience grade has been increased from zero to one star. 展开更多
关键词 Medical buildings Viscous dampers Seismic resilience Repair cost Repair time
下载PDF
Seismic Behavior Research of SRC Frame Special⁃shaped Columns with Viscous Damper
12
作者 ZANG Baijie JIN Xiangying +1 位作者 LI Xiang XIE Peng 《International Journal of Plant Engineering and Management》 2024年第4期193-212,共20页
Based on the non⁃linear finite element analysis software ETABS,a 3⁃spans of 1/2.5⁃scale of two⁃bay and three⁃story frame composed of steel reinforced concrete(SRC)special⁃shaped columns with energy dissipation devices... Based on the non⁃linear finite element analysis software ETABS,a 3⁃spans of 1/2.5⁃scale of two⁃bay and three⁃story frame composed of steel reinforced concrete(SRC)special⁃shaped columns with energy dissipation devices,and time⁃history analysis were employed to research the seismic response of the models.The results show that the seismic performance of SRC frame special⁃shaped columns with fluid viscous dampers was superior to those structures without the devices;most of the energy of the structure imposed by earthquake was dissipated by the viscous dampers.By means of analysis result,the damping parameters of the viscous dampers are optimized;the results show that the vibration damping effect of viscous dampers was sensitive to the spectral characteristics of seismic wave.These results can serve for the structure design,retrofitted design and parameter analysis of the SRC frame with special⁃shaped columns with viscous dampers. 展开更多
关键词 steel reinforced concrete(SRC) viscous damper seismic performance
下载PDF
NEURAL NETWORK REALIZATION OF STRUCTURAL VIBRATION CONTROL USING MR DAMPER
13
作者 周丽 张志成 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2001年第2期144-150,共7页
Magnetorheological (MR) dampers are one of the most promising new devices for civil infrastructural vibration control applications. However, due to their highly nonlinear dynamic behavior, it is very difficult to obta... Magnetorheological (MR) dampers are one of the most promising new devices for civil infrastructural vibration control applications. However, due to their highly nonlinear dynamic behavior, it is very difficult to obtain of a mathematical model of inverse MR damper that has an explicit relationship between the desired damper force and the command signal (voltage). This force voltage relationship is especially required for the structural vibration control design and simulation using MR dampers. This paper focuses on using a neural network (NN) technique to emulate the inverse MR damper model. The output of the neural network can be used to command the MR damper for generating desired forces. Numerical simulations are also presented to illustrate the effectiveness of this inverse model in semi active vibration control using MR dampers. 展开更多
关键词 magnetorhelogical damper neural networks optimal control inverse dynamics
下载PDF
Semi-active control for vibration attenuation of vehicle suspension with symmetric MR damper
14
作者 王恩荣 马晓青 《Journal of Southeast University(English Edition)》 EI CAS 2003年第3期264-269,共6页
A semi-active force tracking PI controller is formulated and analyzed for a magnetorheological (MR) fluid-based damper in conjunction with a quarter-vehicle model. Two different models of the MR-damper are integrated ... A semi-active force tracking PI controller is formulated and analyzed for a magnetorheological (MR) fluid-based damper in conjunction with a quarter-vehicle model. Two different models of the MR-damper are integrated into the closed-loop system model, which includes: a model based upon the mean force-velocity (f-v) behaviour; and a model synthesis comprising inherent nonsmooth hysteretic force and the force limiting properties of the MR damper. The vehicle models are analyzed to study the vibration attenuation performance of the MR-damper using the semi-active force tracking PI control algorithm. The simulation results are also presented to demonstrate the influence of the damper nonlinearity, specifically the hysteresis, on the suspension performance. The results show that the proposed control strategy can yield superior vibration attenuation performance of the vehicle suspension actuated by the controllable MR-damper not only in the sprung mass resonance and the ride zones, but also in the vicinity of the wheel-hop. The results further show that the presence of damper hystersis deteriorates the suspension performance. 展开更多
关键词 magneto-rheological damper vehicle suspension hysteresis model semi-active control
下载PDF
Novel magneto-rheological fluid damper for passive force/torque feedback 被引量:10
15
作者 戴金桥 宋爱国 王爱民 《Journal of Southeast University(English Edition)》 EI CAS 2007年第1期70-74,共5页
The damper is capable of providing a continuously variable dampering force/torque in response to a magnetic field. It consists of an upside cap and an underside cap with a rotor located between them, the magneto-rheol... The damper is capable of providing a continuously variable dampering force/torque in response to a magnetic field. It consists of an upside cap and an underside cap with a rotor located between them, the magneto-rheological (MR) fluid is filled into the gaps between the rotor and the caps. When the viscosity of the MR fluid increases under the influence of the magnetic field, the movement of the rotor will be resisted. The output torque is made up of the torque caused by the magnetic field, the torque caused by the plastic viscosity of the MR fluid, and the torque caused by the coulomb friction. The viscous torque can be calculated by a simple method and the frictional torque can be obtained by experiments. The torque dependent on the magnetic field is obtained by electromagnetic finite dement analysis. Experiments are done on the damper prototype and the validity of the design is verified. 展开更多
关键词 force/torque feedback magneto-rheological fluid damper electromagnetic finite element analysis
下载PDF
DYNAMIC ANALYSIS OF DAMPER CONNECTED ADJACENT BUILDINGS UNDER EARTHQUAKE 被引量:1
16
作者 何琦 徐幼麟 《Transactions of Tianjin University》 EI CAS 1998年第2期20-25,共6页
A formulation of the multi degree of freedom equations of motion for damper connected adjacent multi story buildings under earthquake excitation is presented.The ground acceleration due to e... A formulation of the multi degree of freedom equations of motion for damper connected adjacent multi story buildings under earthquake excitation is presented.The ground acceleration due to earthquake is regarded as a stochastic process,and a pseudo excitation algorithm in frequency domain is implemented in a computer program to handle the non orthogonal damping properties of the system.The effectiveness of joint dampers is then investigated in terms of the reduction of displacement,acceleration and shear force responses of adjacent buildings. 展开更多
关键词 adjacent buildings damper connection EARTHQUAKE pseudo excitation algorithm
下载PDF
Efficiency of the motion amplification device with viscous dampers and its application in high-rise buildings 被引量:30
17
作者 Henry C.Huang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2009年第4期521-536,共16页
After nearly a decade of application and investigation, a motion amplification device with viscous dampers for energy dissipation has been recognized as an effective solution to mitigate wind or seismic excitation, es... After nearly a decade of application and investigation, a motion amplification device with viscous dampers for energy dissipation has been recognized as an effective solution to mitigate wind or seismic excitation, especially for stiff structural systems. As a result of compensation of amplified motion, it has been proved that the efficiency of viscous damper largely depends on the motion amplification device configuration, particularly for device stiflhess. In this paper, a "scissor-jack" type of motion amplification device, called a "toggle brace damper" system, is studied. It is demonstrated that the efficiency of such a device reflected by its amplification factor is not merely a function of its geometric configuration, but is highly dependent on the support elements' stiffness as well, similar to the mechanism of a leverage arm. Accordingly, a mathematical model in terms of complex modulus of the viscous damper with consideration of the support brace's stiffness is established. The results indicate that the efficiency of the motion amplification device with viscous dampers significantly depends on the stiffness of the support elements. Other parameters, such as toggle brace configuration and damping values of the viscous damper, are studied and compared. As an application example, numerical analyses are conducted to study the dynamic performance of a 39-story office tower installed with toggle brace dampers constructed on soft soil in a reclaimed area, under a combined effect of the vortex shedding of an adjacent existing 52-story building and earthquakes. The results show that viscous dampers with a motion amplification system using a properly designed toggle brace device proved to be an effective solution to alleviate the external excitations. 展开更多
关键词 motion amplification device vibration mitigation viscous damper energy dissipation toggle brace damper
下载PDF
Performance evaluation of a novel rotational damper for structural reinforcement steel frames subjected to lateral excitations 被引量:7
18
作者 M.Sanati S.E.Khadem +2 位作者 S.Mirzabagheri H.Sanati M.Y.Khosravieh 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第1期75-84,共10页
In this study,a novel rotational damper called a Rotational Friction Viscoelastic Damper(RFVD) is introduced.Some viscoelastic pads are added to the Rotational Friction Damper(RFD) in addition to the friction discs us... In this study,a novel rotational damper called a Rotational Friction Viscoelastic Damper(RFVD) is introduced.Some viscoelastic pads are added to the Rotational Friction Damper(RFD) in addition to the friction discs used in this conventional device.Consequently,the amount of energy dissipated by the damper increases in low excitation frequencies.In fact,the input energy to the structure is simultaneously dissipated in the form of friction and heat by frictional discs and viscoelastic pads.In order to compare the performance of this novel damper with the earlier types,a set of experiments were carried out.According to the test results,the RFVD showed a better performance in dissipating input energy to the structure when compared to the RFD.The seismic behavior of steel frames equipped with these dampers was also numerically evaluated based on a nonlinear time history analysis.The numerical results verifi ed the performance of the dampers in increasing the energy dissipation and decreasing the energy input to the structural elements.In order to achieve the maximum dissipated energy,the dampers need to be installed in certain places called critical points in the structure.An appropriate approach is presented to properly fi nd these points.Finally,the performance of the RFVDs installed at these critical points was investigated in comparison to some other confi gurations and the validity of the suggested method in increasing the energy dissipation was confi rmed. 展开更多
关键词 seismic excitations rotational friction-viscoelastic damper rotational damper friction pad viscoelastic material energy dissipation
下载PDF
Seismic analysis of structures with a fractional derivative model of viscoelastic dampers 被引量:14
19
作者 Tsu-sheng Chang Mahendra P.Singh 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2002年第2期251-260,共10页
Viscoelastic dampers are now among some of the preferred energy dissipation devices used for passive seismic response control.To evaluate the performance of structures installed with viscoelastic dampers,different ana... Viscoelastic dampers are now among some of the preferred energy dissipation devices used for passive seismic response control.To evaluate the performance of structures installed with viscoelastic dampers,different analytical models have been used to characterize their dynamic force deformation characteristics.The fractional derivative models have received favorable attention as they can capture the frequency dependence of the material stiffness and damping properties observed in the tests very well.However,accurate analytical procedures are needed to calculate the response of structures with such damper models.This paper presents a modal analysis approach,similar to that used for the analysis of linear systems,for solving the equations of inotion with fractional derivative terms for arbitrary forcing functions such as those caused by earthquake induced ground motions.The uncoupled modal equations still have fractional derivatives,but can be solved by numerical or analytical procedures.Both numerical and analytical procedures are formulated.These procedures are then used to calculate the dynamic response of a multi-degree of fleedom shear beam structure excited by ground motions. Numerical results demonstrating the response reducing effect of viscoelastic dampers are also presented. 展开更多
关键词 viscoelastic damper fractioal derivative seismic response
下载PDF
Skyhook-based Semi-active Control of Full-vehicle Suspension with Magneto-rheological Dampers 被引量:11
20
作者 ZHANG Hailong WANG Enrong +2 位作者 MIN Fuhong SUBASH Rakheja SU Chunyi 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第3期498-505,共8页
The control study of vehicle semi-active suspension with magneto-rheological (MR) dampers has been attracted much attention internationally. However, a simple, real time and easy implementing semi-active controller ha... The control study of vehicle semi-active suspension with magneto-rheological (MR) dampers has been attracted much attention internationally. However, a simple, real time and easy implementing semi-active controller has not been proposed for the MR full-vehicle suspension system, and a systematic analysis method has not been established for evaluating the multi-objective suspension performances of MR full-vehicle vertical, pitch and roll motions. For this purpose, according to the 7-degree of freedom (DOF) fullvehicle dynamic system, a generalized 7-DOF MR and passive full-vehicle dynamic model is set up by employing the modified Boucwen hysteretic force-velocity (F-v) model of the MR damper. A semi-active controller is synthesized to realize independent control of the four MR quarter-vehicle sub-suspension systems in the full-vehicle, which is on the basis of the proposed modified skyhook damping scheme of MR quarter-vehicle sub-suspension system. The proposed controller can greatly simplify the controller design complexity of MR full-vehicle suspension and has merits of easy implementation in real application, wherein only absolute velocities of sprung and unsprung masses with reference to the road surface are required to measure in real time when the vehicle is moving. Furthermore, a systematic analysis method is established for evaluating the vertical, pitch and roll motion properties of both MR and passive full-vehicle suspensions in a more realistic road excitation manner, in which the harmonic, rounded pulse and real road measured random signals with delay time are employed as different road excitations inserted on the front and rear two wheels, by considering the distance between front and rear wheels in full-vehicle. The above excitations with different amplitudes are further employed as the road excitations inserted on left and right two wheels for evaluating the roll motion property. The multi-objective suspension performances of ride comfort and handling safety of the proposed MR full-vehicle suspension are thus thoroughly evaluated by comparing with those of the passive full-vehicle suspension. The results show that the proposed controller can ideally improve multiobjective suspension performances of the ride comfort and handling safety. The proposed harmonic, rounded pulse and real road measured random signals with delay time and asymmetric amplitudes are suitable for accurately analyzing the vertical, pitch and roll motion properties of MR full-vehicle suspension system in a more realistic road excitation manner. This research has important theoretical significance for improving application study on the intelligent MR semi-active suspension. 展开更多
关键词 magneto-rheological damper skyhook policy semi-active control multi-objective performances full-vehicle suspension
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部