The high energy cosmic-radiation detection(HERD)facility is planned to launch in 2027 and scheduled to be installed on the China Space Station.It serves as a dark matter particle detector,a cosmic ray instrument,and a...The high energy cosmic-radiation detection(HERD)facility is planned to launch in 2027 and scheduled to be installed on the China Space Station.It serves as a dark matter particle detector,a cosmic ray instrument,and an observatory for high-energy gamma rays.A transition radiation detector placed on one of its lateral sides serves dual purpose,(ⅰ)calibrating HERD's electromagnetic calorimeter in the TeV energy range,and(ⅱ)serving as an independent detector for high-energy gamma rays.In this paper,the prototype readout electronics design of the transition radiation detector is demonstrated,which aims to accurately measure the charge of the anodes using the SAMPA application specific integrated circuit chip.The electronic performance of the prototype system is evaluated in terms of noise,linearity,and resolution.Through the presented design,each electronic channel can achieve a dynamic range of 0–100 fC,the RMS noise level not exceeding 0.15 fC,and the integral nonlinearity was<0.2%.To further verify the readout electronic performance,a joint test with the detector was carried out,and the results show that the prototype system can satisfy the requirements of the detector's scientific goals.展开更多
This article describes the data processing and acquisition system for the HT-7 mul-tipulse Thomson scattering diagnostic. An eight-pulse laser is used in the Thomson scattering system to obtain electron temperature pr...This article describes the data processing and acquisition system for the HT-7 mul-tipulse Thomson scattering diagnostic. An eight-pulse laser is used in the Thomson scattering system to obtain electron temperature profiles at eight different times throughout an entire plasma discharge. The major components of the diagnostic system consist of a multipulse Nd-glass laser, a photodetector's subsystem, a calibration set and a CAMAC data processing and acquisition system. The data processing software along with LeCroy 2250L will perform the data acquisition. In order to simplify the operation and extend the capability of its compatibility with other math softwares, the processing software has been improved by the authors. The new software based on the VC++ easily utilizes some math softwares to calculate the electron temperature. The new software is simpler and more operational than the old one.展开更多
Testing of a triple gas electron multiplier (GEM) with pixel-pads is described. Images by scanning and suspending radioactive sources were obtained by using 96 channels digital data acquisition (DAQ) system which ...Testing of a triple gas electron multiplier (GEM) with pixel-pads is described. Images by scanning and suspending radioactive sources were obtained by using 96 channels digital data acquisition (DAQ) system which was composed of 96 8×8 mm2 pads and associated electronics channels.展开更多
基金supported by the National Natural Science Foundation of China(Nos.12375193,11975292,11875304)the CAS“Light of West China”Program+1 种基金the Scientific Instrument Developing Project of the Chinese Academy of Sciences(No.GJJSTD20210009)the CAS Pioneer Hundred Talent Program。
文摘The high energy cosmic-radiation detection(HERD)facility is planned to launch in 2027 and scheduled to be installed on the China Space Station.It serves as a dark matter particle detector,a cosmic ray instrument,and an observatory for high-energy gamma rays.A transition radiation detector placed on one of its lateral sides serves dual purpose,(ⅰ)calibrating HERD's electromagnetic calorimeter in the TeV energy range,and(ⅱ)serving as an independent detector for high-energy gamma rays.In this paper,the prototype readout electronics design of the transition radiation detector is demonstrated,which aims to accurately measure the charge of the anodes using the SAMPA application specific integrated circuit chip.The electronic performance of the prototype system is evaluated in terms of noise,linearity,and resolution.Through the presented design,each electronic channel can achieve a dynamic range of 0–100 fC,the RMS noise level not exceeding 0.15 fC,and the integral nonlinearity was<0.2%.To further verify the readout electronic performance,a joint test with the detector was carried out,and the results show that the prototype system can satisfy the requirements of the detector's scientific goals.
基金The project supported by the National Science Foundation of China(No.10075049 and No.10275068)
文摘This article describes the data processing and acquisition system for the HT-7 mul-tipulse Thomson scattering diagnostic. An eight-pulse laser is used in the Thomson scattering system to obtain electron temperature profiles at eight different times throughout an entire plasma discharge. The major components of the diagnostic system consist of a multipulse Nd-glass laser, a photodetector's subsystem, a calibration set and a CAMAC data processing and acquisition system. The data processing software along with LeCroy 2250L will perform the data acquisition. In order to simplify the operation and extend the capability of its compatibility with other math softwares, the processing software has been improved by the authors. The new software based on the VC++ easily utilizes some math softwares to calculate the electron temperature. The new software is simpler and more operational than the old one.
文摘Testing of a triple gas electron multiplier (GEM) with pixel-pads is described. Images by scanning and suspending radioactive sources were obtained by using 96 channels digital data acquisition (DAQ) system which was composed of 96 8×8 mm2 pads and associated electronics channels.